Records from 1985 to 2018. Most recent: inspection, 21 May 2018.
Inspection history · 85
21 May 2018
Load Line/Change of Employment
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6419757
18 October 2016
Periodic Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6024964
30 September 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6007782
12 February 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5801353
22 January 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5801688
16 December 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5782936
17 September 2015
MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5738349
24 July 2014
Deficiency Check · MTSA Verification · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4932085
27 July 2012
Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4392051
27 June 2012
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4358788
14 July 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4095781
30 June 2011
Periodic Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4062739
5 August 2010
MARPOL Annex I Examination · Deficiency Check · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3813665
27 August 2009
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3578233
13 August 2009
Annual Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3579010
16 July 2009
MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3536109
7 May 2008
COI Inspection · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3201051
4 December 2007
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3109563
26 September 2007
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3072599
14 September 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3057668
24 August 2007
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3036494
24 August 2007
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3040790
19 July 2006
Deficiency Check · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2718460
5 May 2006
Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2641579
13 January 2006
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2566407
16 December 2005
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2552326
7 December 2005
MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2547728
10 May 2005
MTSA Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2354196
29 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2345909
11 November 2004
Examination of Repairs · Annual Inspection · Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2239318
11 November 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2251862
30 July 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2152005
2 June 2004
Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2086505
27 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2014473
19 February 2004
Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2009190
19 February 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2009347
10 June 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1814060
12 May 2003
COI Inspection · Damage Survey · Hull Examination · Internal Structural Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1791612
21 August 2002
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1664441
23 July 2002
Damage Survey · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1650830
21 August 2001
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1447132
8 August 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1423624
25 July 2001
Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1417332
21 June 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1050751
26 July 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1105285
1 July 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084835
23 January 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 169848
30 June 1998
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1127214
21 August 1997
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 783096
13 January 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1099028
24 October 1996
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1380679
26 August 1996
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1086396
15 August 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 674496
25 July 1996
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1424266
23 July 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 215191
20 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1089507
10 July 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875741
6 June 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 865957
25 May 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 866077
5 October 1993
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830948
5 May 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 53695
21 December 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 682631
28 November 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 90340
28 November 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 500913
15 July 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 958236
5 June 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254451
28 February 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1267460
6 February 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 119407
6 February 1992
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 955869
26 December 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955131
12 August 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245302
25 March 1991
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1213248
9 March 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911331
26 October 1990
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222924
1 June 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219379
18 May 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230333
7 October 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196875
26 May 1988
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1204335
30 September 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013770
28 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342413
14 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028949
30 May 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986996
30 May 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294290
6 September 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1300673
1 July 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 497119
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 September 2016
Resolved
Prior to carrying cargo and prior to getting underway, vessel is to receive annual COI inspection and MARPOL annual surveys once it arrives into Jacksonville, FL.
Action required: 705 - Other - as specified
Resolved 18 October 2016
Resolution: Sector Jacksonville conducted satisfactory annual inspection, IOPP & IAPP surveys
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 24 July 2014
Resolved
As per 46 CFR 42.15-7(b)/(c), install lower life line and chains around perimeter of vsl.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2014
Resolution: [name withheld] and [name withheld] witnessed satisfactory installation of life line.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 July 2014
Resolved
Repair/renew missing hardware and chains around perimeter of vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2014
Resolution: MI witnessed satisfactory installation of missing hardware and chains around perimeter.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 July 2014
Resolved
Repair/renew uppper life line on stbd amidship rail system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2014
Resolution: MI witnessed proper repair of life line.
Construction/Loadline › Structures › Deck Plating
Issued 27 June 2012
Resolved
Crop and renew wasted and holed tank top IWO center rake manhole TO GOOD STEEL. Provide UT readings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 July 2012
Resolution: By class
Construction/Loadline › Structures › Rake
Issued 27 June 2012
Resolved
Remove excess water and debris from the follwing void tanks to determine the causes of ingression: Bow rake, port and center, and #1 port and center.
Action required: 705 - Other - as specified
Resolved 4 July 2012
Resolution: Cleared by class.
Construction/Loadline › Hull › Weld
Issued 27 June 2012
Resolved
Rerair broken ladder rung in center void rake and broken weldment in the port void rake @ the bottom of ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 July 2012
Resolution: Cleared by class
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 June 2012
Resolved
Crop and renew waster underdeck longitudinal frame support member IWO manhole opening, center void rake.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 July 2012
Resolution: Cleared by class.
Construction/Loadline › Penetrations › Flange Pad
Issued 27 June 2012
Resolved
Port rake void: Crop and renew fractured/broken bottom longitudinal support frames IWO ladder, 2nd bay, cropand renew holed transverse bulkhead, 2nd bay, and crop and renew wasted transverse buck frame of the 3rd bay fwd.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 July 2012
Resolution: Cleared by class.
Construction/Loadline › Penetrations › Valve Flange
Issued 27 June 2012
Resolved
Loaded condition: sound the following tanks to assist in determining ingression: rake port and center, #1 port and center.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2012
Resolution: Cleared by class.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 5 August 2010
Resolved
Instructed POC to install 02 B-2 portable fire extinguishers, one at each auxilary machinery space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2010
Resolution: 2 B-II''s installed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 5 August 2010
Resolved
Repair #1 and 2 fractured longitudinal bottom longs IWO Port FWD rake.
Due 5 September 2010
Resolved 1 September 2010
Resolution: Fractures repaired
Construction/Loadline › Structures › Door
Issued 4 September 2009
Resolved
Renew/Repair fwd WTD. Door is currently unable to be closed due to warpage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 October 2009
Resolved 1 October 2009
Resolution: Wtd and frame renewed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 September 2009
Resolved
Properly secure/mount navigation lights. Current securing method is inadequate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 October 2009
Resolved 1 October 2009
Resolution: Nav. Lts were properly secured.
Deck/Cargo › Towing › Chocks
Issued 4 September 2009
Resolved
Inspect and verify integrity/strength of all bits and chocks during next drydock. Bitts are severely wasted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 July 2011
Resolved 3 June 2011
Resolution: Complete during this D/D period.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 4 September 2009
Resolved
Repair/Replace fwd day shape
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 October 2009
Resolved 1 October 2009
Resolution: Day shape marker was repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 September 2009
Resolved
Attach 2 courses of railing over working bits along deck. Currently, areas around bits are open with no railing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 October 2009
Resolved 1 October 2009
Resolution: Twoo courses of railing replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 July 2009
Resolved
Remove broken/inactive stern light from vessel.
Due 10 August 2009
Resolved 13 August 2009
Resolution: Stern light removed
Construction/Loadline › Structures › Manhole
Issued 16 July 2009
Resolved
Provide missing nuts on all man hole covers, including replacement of studs as required.
Due 10 August 2009
Resolved 13 August 2009
Resolution: Completed
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 July 2009
Resolved
Remove batteries and all HAZMAT from vessel.
Due 10 August 2009
Resolved 13 August 2009
Resolution: Batteries removed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 July 2009
Resolved
Repair/renew all deck rail stanchions.
Due 10 August 2009
Resolved 13 August 2009
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 16 July 2009
Resolved
Update and maintain SOPEP checklist in accordance with plan.
Due 10 August 2009
Resolved 13 August 2009
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 July 2009
Resolved
Remove all trash and debris from barge.
Action required: 705 - Other - as specified
Due 4 October 2009
Resolved 1 October 2009
Resolution: Trash and debris removed from the vessel.
Construction/Loadline › Structures › Manhole
Issued 26 September 2007
Resolved
Replace all missing studs on all man hole covers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 28 November 2007
Resolution: Missing studs replaced during inport period in Jacksonville, FL.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 August 2007
Resolved
Revoke the COI for failure to conduct the annual exam as required by 46 CFR 91.27.1. COI must be renewed prior to vessel's departure from port w/ cargo onboard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2007
Resolution: Completed a renewal COI exam and issued a temp COI.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 24 August 2007
Resolved
Re-paint port and stbd draft marking, vessels name and loadline marking on the vessel's hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 26 October 2007
Resolution: All marking completed.
Construction/Loadline › Hull › Hull Plating
Issued 24 August 2007
Resolved
Class to inspect the stbd bow rake in way of the sharp inset on the side shell to ensure structrual intergrety. Results must be provided to USCG Marine Inspector for review.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 26 September 2007
Resolution: Class inspected the rake and sent the report to USCG Jax.
Construction/Loadline › Structures › Manhole
Issued 24 August 2007
Resolved
Replace missing studs for the aft port side void cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 26 September 2007
Resolution: Studs were replaced
Construction/Loadline › Structures › Door
Issued 24 August 2007
Resolved
Properly service the weathertight door on the fwd breakshield bulkhead to ensure proper operation. Door hinge are loose and dogs not operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 27 September 2007
Resolution: The door is replaced
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 August 2007
Resolved
Remove all debris from the deck areas.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 27 September 2007
Resolution: Debris removed.
Electrical › Electric Supply System (service) › Cable
Issued 24 August 2007
Resolved
Remove all dead-ended cable from the dek area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 27 September 2007
Resolution: Cables are removed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 August 2007
Resolved
Replace/repair the fractured & fractured rails and replace safety wire as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 27 September 2007
Resolution: The rails are repaired and the wire is replaced
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 24 August 2007
Resolved
Vessel does not have a valid COFR and will be prohibit from entering US waters until documentary proof of the valid COFR is received.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 28 August 2007
Resolution: Received documentary proof.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 August 2007
Resolved
Vessel missed its window to conduct annual inspection of the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2007
Resolved 24 August 2007
Resolution: Vessel operator arranged for COI inspection in GTMO Cuba. New COI issued; expired COI removed from vessel.
Construction/Loadline › Penetrations › Weld
Issued 19 July 2006
Resolved
Repair starboard running light deflector, welds are broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 16 August 2006
Resolution: Deflector repaired.
Electrical › Lighting (service) › Switch
Issued 19 July 2006
Resolved
Repair portside running light photocell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 16 August 2006
Resolution: Light repaired and tested.
Construction/Loadline › Hull › Weld
Issued 19 July 2006
Resolved
Repair cracked welds on port upper rub rail approximately 15' forward of the pimsoil mark.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 16 August 2006
Resolution: Crack welded properly to the satisfactory of the attending Marine Inspector.
Pollution Prevention/Response › Response Equipment › Containers
Issued 19 July 2006
Resolved
Provide pillows(oil only) for the vessel's SOPEP KIT as required and properly label container.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2006
Resolved 16 August 2006
Resolution: Equipment provided.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 May 2006
Resolved
#2 starboard void, crop and renew wasted longitudinal frames between FWD bulkhead and 2nd transverse frame. 4 inboard and 2 outboard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 19 July 2006
Resolution: Verified by Class.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 May 2006
Resolved
#2 starboard void, crop and renew wasted transverse web frames (three AFT in space) in area where deck support trusses are attached.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 19 July 2006
Resolution: Verified by class.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 May 2006
Resolved
#2 port void, crop and renew the three moat inboard longitudinal bottom frames entire length of void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 19 July 2006
Resolution: Verified by class.
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 May 2006
Resolved
#4 center void, crop and renew fractured and wasted longitudinal hull plating frames #2 and #3 from the port bulkhead in way of the 4th transverse web frame from AFT bulkhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 19 July 2006
Resolution: Verified by class.
Construction/Loadline › Hull › Bracket
Issued 9 May 2006
Resolved
Crop and renew angle bracket below the hatch assess cover in port side AFT rake
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 19 July 2006
Resolution: Verified by class.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 May 2006
Resolved
Repair or Replace broken stanchion and wire rope as required thru out barge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 24 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 May 2006
Resolved
Make the following spaces ready for inspection : 2P, 2S, 3S, 3C, 4S, 4P, 4C, 5C, 5S, and stern Rake center.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2006
Resolved 24 May 2006
Construction/Loadline › Structures › Manhole
Issued 5 May 2006
Resolved
Replace #3 center void space cover and studs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 24 May 2006
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 5 May 2006
Resolved
Remove or Replace sounding tube in void spaces as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 24 May 2006
Construction/Loadline › Hull › Bracket
Issued 5 May 2006
Resolved
Crop and renew angle bracket atdeck AFT protion of #1 center void space.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2006
Construction/Loadline › Hull › Weld
Issued 5 May 2006
Resolved
Repair fractured weld #7 side shell support frame in #1 STBD void
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2006
Construction/Loadline › Hull › Bracket
Issued 5 May 2006
Resolved
Repair #5 angle bracket in #1STBD void.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 May 2006
Resolved
Repair or replace ladder in the following voids #1 port, #1 center, #4 prot, STBD stern Rake, port stern Rake.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 24 May 2006
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 December 2005
Resolved
Replace all wasted/broken studs for all hatch covers to void spaces forward and aft.
Condition: Improper/Lack of Maintenance
Due 10 January 2006
Resolved 13 January 2006
Resolution: Corrected..
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 December 2005
Resolved
Replace all wasted/broken stanchions throughout vessel and replace all stanchion wire rope.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 13 January 2006
Resolution: Stanchions were renewed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 December 2005
Resolved
Replace wated stanchion supporting stern running light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 13 January 2006
Resolution: Stanich was renewed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 December 2005
Resolved
Remove all wire nuts from the aft battery box for stern running light and repair all damaged wiring.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 13 January 2006
Resolution: Wire nuts were removed.
Stability › Weathertight Integrity › General
Issued 10 December 2005
Resolved
Make weathertight door forward operational including repair of all dogs and replacing gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 13 January 2006
Resolution: Weather tight door is operable.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 10 December 2005
Resolved
Crop and renew electrical wire tray throughout vessel.
Condition: Improper/Lack of Maintenance
Due 10 January 2006
Resolved 13 January 2006
Resolution: Wire tray renewed.
Pollution Prevention/Response › Response Equipment › Non-sparking Hand Scoops/Shovels/Buckets
Issued 10 December 2005
Resolved
Provide non-sparking shovels and scoops for SOPEP Kit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 January 2006
Resolved 13 January 2006
Resolution: Shovels and scoops were purchased.
Documentation › Certificates/Documents › IOPP Certificate
Issued 20 December 2004
Resolved
Present a Coast Guard approval letter to the attending Marine Inspector for the vessel SOPEP.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2005
Resolved 10 December 2005
Resolution: Vessel representative presented to attending Marine Inspector documentary proof of approval letter for SOPEP.
Deck/Cargo › Towing › Towline
Issued 20 December 2004
Resolved
Attach emergency tow wire to the barge using a fitting of approbiate/sufficient strength.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 December 2004
Resolved
Remove all disabled unserviceable storage batteries from the main deck.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2004
Construction/Loadline › Markings › Load Line Mark
Issued 20 December 2004
Resolved
Properly mark load line on the port side (fingers to the bow).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2005
Resolved 13 January 2006
Resolution: Loadlines were properly marked.
Navigation › Collision/Grounding Avoidance
Issued 23 May 2003
Resolved
Prove proper ops of Navigation Lights LEGACY COMPONENT DESC: Navigation Lights
Condition: Unknown
Due 11 June 2003
Resolved 11 June 2003
Resolution: FOUND TO BE PROPER.
Construction/Loadline › Hull
Issued 12 May 2003
Resolved
Crop and Replace as new a 22' x 11' section of bow plate and associated internals located on port and center bow rake, extending back into the #1 port and center voids. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 May 2003
Resolved 23 May 2003
Construction/Loadline › Hull
Issued 12 May 2003
Resolved
Crop and Replace as new marked 18" x 18" insert in bottom plate in #1 starboard void bottom plate LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 May 2003
Construction/Loadline › Penetrations
Issued 23 July 2002
Resolved
BOLT CLOSED ALL OPEN FLUSH DECK MANHOLE COVERS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2002
Construction/Loadline › Hull
Issued 23 July 2002
Resolved
DETERMINE THE SOURCE OF INFLOW TO THE #1 P AND C VOIDS. DEWATER SAME. REPAIRS TO BE DETERMINED. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2002
Resolution: IDENTIFIED NUMEROUS FRACTURES IN BOTTOM PLATTING, EFFECTED TEMPORARY REPAIRS. RENEWED SECTION OF LONG BULKHEAD TO STOP FLOW OF WATER TO #1 CENTER VOID. RENEWED ASSOCIATED DAMAGED STRUCTURAL MEMBERS. REPAIRS ARE OF A TEMP NATURE, REPLACE AT NEXT D/D.
Documentation › Certificates/Documents
Issued 23 July 2002
Resolved
COMPLETE THE REINSPECTION. LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2002
Construction/Loadline › Hull
Issued 23 July 2002
Resolved
PROVIDE REPAIR CALCULATION FOR TEMP REPAIRS OF FRACTURES IN #1 PORT VOID. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Due 28 August 2002
Resolved 27 August 2002
Resolution: RECEIVED COPY OF CALCULATIONS, FOUND SATISFACTORY.
Construction/Loadline › Hull
Issued 23 July 2002
Resolved
#1 PORT VOID, REPAIR VARIOUS FRACTURES AND CRACKS IN THE AFT BOTTOM TRANS FRAME. STOP WATER LEAKAGE INTO THIS SPACE. LEGACY COMPONENT DESC: Transverse Frame
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2002
Construction/Loadline › Hull
Issued 23 July 2002
Resolved
Make bow rake voids available for inspection of temporary repairs. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 6 September 2002
Resolved 21 August 2002
Resolution: Entered voids, no indication of leakage visible, repairs appear to be holding.
Construction/Loadline
Issued 25 July 2001
Resolved
STARBOARD BOW RAKE, CROP AND RENEW (1) TRANSVERSE OUTBOARD FRAME AS MARKED_x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 25 July 2001
Resolved
STARBOARD AFT RAKE, CROP AND RENEW #3 FRAME 18 X 18 AS MARKED AT SIDE SHELL.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 25 July 2001
Resolved
CENTER BOW RAKE, RENEW (5) BRACKETS AT AFT BULKHEAD OUTBOARD OF BOTH DEEP FRAMES.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 25 July 2001
Resolved
PORT BOW RAKE, INSERT SIDE SHELL AND BOTTOM PLATE APPROX 18 X 36 EACH AT CHINE AS MARKED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 25 July 2001
Resolved
#1 PORT VOID, CROP AND RENEW #1 AND 2 BOTTOM TRANSVERSE FRAMES INBOARD AS MARKED. CROP AND RENEW #4 SIDE LONG AND BRACKET AT AFT BULKHEAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 25 July 2001
Resolved
#1 STARBOARD VOID, CROP AND RENEW #3 SIDE LONG AND BRACKET AT AFT BULKHEAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Electrical
Issued 1 July 1999
Resolved
CHOCK FWD NAV LIGHT BATTERIES IN PLACE AND REMOVE DEAD ENDED UNUSED WIRING.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Electrical
Issued 1 July 1999
Resolved
REPAIR ELECTRICAL STUFFING TUBE TO STERN LIGHT BATTERY BOX. CHOCK BATTERY IN PLACE.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Accommodation/Occupational Safety
Issued 1 July 1999
Resolved
REMOVE OR REPAIR CRACKED LIFE LINES STANCHIONS PORTSIDE AS NECESSARY.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Construction/Loadline
Issued 1 July 1999
Resolved
REWORK DOGS ON FWD BULKHEAQD DOOR AND CHALK TEST.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999
Electrical
Issued 21 August 1997
Resolved
Remove all trash from battery boxes.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Electrical
Issued 21 August 1997
Resolved
Properly secure batteries in battery boxes.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Electrical
Issued 21 August 1997
Resolved
Stow all batteries on approved surfaces.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Construction/Loadline
Issued 21 August 1997
Resolved
Replace sprung watertight door in wave protection bulkhead on main deck.
Condition: Unknown
Due 12 September 1997
Resolved 21 August 1997
Construction/Loadline
Issued 21 August 1997
Resolved
Properly install & secure hull void covers and prove watertightness.
Condition: Unknown
Due 21 August 1997
Resolved 21 August 1997
Construction/Loadline
Issued 21 August 1997
Resolved
Renew/replace lifeline stancions as needed.
Condition: Unknown
Due 12 September 1997
Resolved 21 August 1997
Documentation
Issued 21 August 1997
Resolved
Provide copy of Stability Letter to [name withheld] and keep copy on vessel.
Condition: Unknown
Due 12 September 1997
Resolved 21 August 1997
Construction/Loadline
Issued 24 October 1996
Resolved
MAKE PERMANENT REPAIRS TO BOTTOM LONGS AND TRIPPED BRACKETS I.W.O. AFT BULKHEAD, FWD RAKE. (1 LONGITUDINAL, 4 BRACKETS IN PORT VOID, 4 BRACKETS INCENTER VOID)
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Construction/Loadline
Issued 24 October 1996
Resolved
MAKE PERMANENT REPAIRS TO SIDE LONG(1) AND TRIPPED BRACKETS(4), I.W.O. AFT BULKHEAD, 2ND LONG DOWN FROM DECK, #1 STBD VOID.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Documentation
Issued 25 July 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 August 1996
Resolved 15 August 1996
Accommodation/Occupational Safety
Issued 25 July 1996
Resolved
FIVE OF THE STANCHINS POLES WERE SEVERELY DAMAGED AND LIFELINES RUNNING THROUGH THE STANCHINS NEED TO BE REDONE.
Condition: Unknown
Due 25 July 1996
Resolved 25 July 1996
Navigation
Issued 25 May 1994
Resolved
PROVE PROPER OPERATION OF STERN LIGHT. VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS TILL THIS REQUIREMENT IS CLEARED BY A MARINE ISPECTOR OF THE COGNIZANT OCMI.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Lifesaving
Issued 6 February 1992
Resolved
REPLACE/RENEW DECK RAILS WHERE DAMAGED PORT AND STARBOARD SIDE FORWARD. REPAIRS TO BE MADE TO SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 6 February 1992
Resolved 6 February 1992
Construction/Loadline
Issued 12 August 1991
Resolved
NO.2 CENTER TANK PORT SIDE FWD BULKHEAD; WELD ACCESS COVER.
Condition: Unknown
Due 5 November 1991
Resolved 5 November 1991
Construction/Loadline
Issued 12 August 1991
Resolved
NO.1 AFT PORT TANK; C&R NO.3 TIE BRACKET & APPROXIMATELY 2 FT OF S/S LONG.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Construction/Loadline
Issued 12 August 1991
Resolved
NO.1 AFT PORT TANK; V & W CRACKED WELDS ON NO.5 SIDE SHELL VERTICAL_x001C_ STIFFENER BETWEEN NO. 2 SIDE SHELL LONG AND MAIN HORIZONTAL STIFFENER.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Construction/Loadline
Issued 12 August 1991
Resolved
NO.1 STBD TANK; C & R NO.2 & 3 HORIZONTAL TIE BRACKETS & APPROXIMATELY 2FT_x001C_OF SIDE SHELL LONG IN WAY OF AFT BULKHEAD.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Construction/Loadline
Issued 12 August 1991
Resolved
CROP AND RENEW BENT TIE BRACKET IN NUMBER 6 PORT TANK, AFT CORNER.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Construction/Loadline
Issued 12 August 1991
Resolved
NO.6 PORT TANK AFT; C&R NO.1.S/S LONG AND NO.5 VERT STIFFENER(APROX 5' FT)IN WAY OF AFT BULKHEAD.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Construction/Loadline
Issued 12 August 1991
Resolved
NO.3 STBD TANK; C&R NO.2 OUTBD VERT STIFFENER APPROX. 16 FT; NO.3,4,AND 5 _x001C_SIDE SHELL LONGS APROX. 4FT; AND 5FT X 6FT OF SIDE SHELL PLATING IN WAY OF NO.3 AND 4 SIDE SHELL LONGS.
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Construction/Loadline
Issued 12 August 1991
Resolved
NO.5 PORT TANK, NO.3 BAY; C&R 6FT OF NO. 3 VERT STIFFENER AND 6FT OF HORIZONTAL STIFFNER WHERE THEY MEET._x001C_
Condition: Unknown
Due 12 August 1991
Resolved 12 August 1991
Construction/Loadline
Issued 9 March 1991
Resolved
PROCEED FROM NEW LONDON CT TO THE PORT OF NEW YORK TO OFFLOAD CONTAINER CARGO. UPON COMPLETION OF OFFLOADING CARGO AND PRIOR TO PLACING THE VESSELBACK IN SERVICE, THE VESSEL IS TO BE DRYDOCKED FOR REPAIRS TO #5 STBD AND #5 CENTER TANKS. REPAIRS TO BE COMPLETED TO SATISFACTION OF NYCMI.
Condition: Unknown
Due 9 March 1991
Resolved 9 March 1991
Navigation
Issued 18 May 1990
Resolved
SECURE ALL BATTERIES ON VESSEL TO PREVENT MOVEMENT.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Navigation
Issued 18 May 1990
Resolved
REPAIR STERN LIGHT TO FULL OPERATIONAL STATUS.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Navigation
Issued 18 May 1990
Resolved
REPAIR/SECURE STERN LIGHT BATTERY BOX COVER.
Condition: Unknown
Due 18 May 1990
Resolved 18 May 1990
Construction/Loadline
Issued 26 May 1988
Resolved
MAKE TEMPORARY REPAIR TO 12" X 1/4" OPENING IN PORT AFT CORNER OF PORT AFT RAKE WHERE SIDE SHELL SEPARATED FROM MAIN DECK. OWNER REP STATED THAT PLATEWOULD BE INSERTED IN FUTURE.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Documentation
Issued 26 May 1988
Resolved
NO MACHINERY MAY BE CARRIED UNTIL AN UPDATED CERTIFICATE OF RESPONSIBILITY IS OBTAINED.
Condition: Unknown
Due 26 May 1988
Resolved 26 May 1988
Construction/Loadline
Issued 30 September 1987
Resolved
CROP & RENEW SHELL PLATE AND DAMAGED INTERNALS AT SET-IN LOCATED IN FORWARDPORT CORNER OF THE FORWARD RAKE'S CTR COMPARTMENT (APPROX 10'X8').
Condition: Unknown
Due 30 September 1987
Resolved 30 September 1987
Construction/Loadline
Issued 30 May 1986
Resolved
GAS FREE BARGE AND CONDUCT INTERNAL EXAMINATION OF ALL COMPARTMENTS.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Construction/Loadline
Issued 30 May 1986
Resolved
MAKE PERMANENT REPAIRS TO FORWARD RAKE BOTTOM PLATING LOCATED IN TWO AREAS:STARBOARD;A)10' BY 12' AREA 15' BELOW HEADLONG;PORT;A)WHERE BOTTOM PLATING MEETS SIDE SHELL PLATING10' BELOW HEADLONG.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986
Construction/Loadline
Issued 30 May 1986
Resolved
MAKE PERMANENT REPAIRS TO PORT SIDE SHELL PLATING (SHEER STRAKE 6'BY 12' AREA) JUST FORWARD OF LOAD LINE MARKING.
Condition: Unknown
Due 30 May 1986
Resolved 30 May 1986