Records from 1992 to 2025. Most recent: inspection, 29 May 2025.
Inspection history · 52
29 May 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8147751
20 August 2024
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7984951
27 September 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7800119
27 June 2023
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7726421
15 September 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7559354
30 March 2022
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7421310
14 September 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7312061
29 July 2020
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7019341
3 January 2020
Administrative Inspection · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949852
25 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5840619
8 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5017682
17 July 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4925396
8 July 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4933440
17 June 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4891577
8 August 2013
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4679817
28 April 2013
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4639472
6 May 2011
Industry Initiated Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4003849
23 October 2010
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3883095
7 April 2010
Industry Initiated Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3711764
5 September 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3320043
13 February 2008
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3151907
24 July 2007
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3007061
3 January 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2559710
20 July 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2448677
14 March 2005
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2311650
28 July 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2148166
16 March 2004
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2026646
21 January 2004
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1992695
15 December 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1720443
4 October 2002
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1688011
22 June 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 731994
15 June 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 123986
24 April 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 107802
23 August 2000
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 823844
22 May 2000
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 818506
10 April 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 122824
9 April 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 221162
5 February 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 149833
30 January 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 146070
9 December 1999
Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 1496733
22 September 1998
Uninspected Towing Vessel
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 801198
22 May 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 655291
5 May 1998
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 113166
1 November 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 162961
29 September 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1446536
27 January 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 675761
11 December 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 213256
21 August 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 230170
8 August 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 675753
30 July 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 147634
13 April 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 87400
6 February 1992
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 119407
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 May 2025
Resolved
There must be an installed or portable bilge pump for emergency dewatering. MI observed vessels installed bilge system to be inoperable due to a leaking pump shaft packing, replace/repair. Vessel has portable pump, fire pump and ballast pump as alternative means of dewatering until installed bilge system is operational.
46 CFR 143.275
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2025
Resolved 25 June 2025
Resolution: Replaced pump.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 May 2025
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Vessel had 02 pennants on the life float that were deteriorated and in need of replacement.
46 CFR 141.320
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 25 June 2025
Resolution: Replaced Penants.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 May 2025
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel, and which may allow water to enter
the vessel. Vessels aft two hatches had excessive rust on the sealing(knife) edge and worn out gaskets. Replace
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 25 June 2025
Resolution: Replaced gaskets and worked knife edge.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 May 2025
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Found a dead end wire in the gyro compass room. Remove.
46 CFR 143.400 (g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 25 June 2025
Resolution: Replaced juntion box, cleaned up dead end wires.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2025
Resolved
Regardless of the option chosen to obtain a COI, upon obtaining a COI each towing vessel must then undergo a drydock and internal structural examination at the following intervals:(1) A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. Vessel is to commence dry dock, ISE Exam prior to 30JUNE2025.
46 CFR 137.300 (a)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2025
Resolved 9 July 2025
Resolution: DD completed Obj evidence submitted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2025
Resolved
Provide objective evidence of a satisfactory external management audit conducted by the cognizant third-party organization NLT 18Sept2025. Failure to complete and provide evidence of this audit will result in the vessel being reverted to the Coast Guard inspection option, suspension of vessel operations, or COI revocation, as determined by the OCMI.
46CFR 138.315
Action required: 705 - Other - as specified
Due 18 September 2025
Resolved 19 August 2025
Resolution: 19AUG25: Vessels TPO sent in the vsl/manag.audit reports for the BUCK PATE. Report was accepted and the 835 requirement for 6 month audit was cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2025
Resolved
Provide objective evidence of a satisfactory external vessel audit conducted by the cognizant third-party organization NLT 18Sept2025. Failure to complete and provide evidence of this audit will result in the vessel being reverted to the Coast Guard inspection option, suspension of vessel operations, or COI revocation, as determined by the OCMI.
46 CFR 138.315
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2025
Resolved 19 August 2025
Resolution: 19AUG25: Vessels TPO sent in the vsl/manag.audit reports for the BUCK PATE. Report was accepted and the 835 requirement for 6 month audit was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 20 September 2021
Resolved
A towing vessel must meet the applicable fucntional requirements for survival craft. Life float required by the COI was on board. The vessel must comply with several craft requirements.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 September 2021
Resolved 21 September 2021
Resolution: Life float installed with proper gear.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 September 2021
Resolved
The frame or support of any semi-portable fire extinguishers fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy seas. 160-B was secured to bulkhead with a zip tie. 160-B must be secured in a permenant manner.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 21 September 2021
Resolution: 160-B frame permenantly secured to bulk head.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2020
Resolved
All electrical wires feeding into a panel box, shall be properly connected to prevent moisture from getting into the panel and prevent chaffing. The wires feeding into the SME Alarm panel, in the engine room, did not have any connectors, thus allowing moisture to enter the panel box and permitting the wires to chaff on the sharp edge of the holes on the panel. Install wires to the SME panel box, using connectors, that will prevent moisture from entering the panel and unnecessary chaffing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2020
Resolved 29 July 2020
Resolution: The wires feeding into the starboard main engine alarm panel have been properly mounted to prevent moisture from entering the control panel.
Electrical
Issued 29 September 1997
Resolved
28SEP97 Issued COTP Order 68-97 based on report of failure of #1 SSGen. Vessel not to conduct further commercial operations until repairs completedand satisfactory to Marine Inspector.
Condition: Unknown
Due 1 October 1997
Resolved 1 October 1997