Records from 2000 to 2026. Most recent: inspection, 28 May 2026.
Inspection history · 54
28 May 2026
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8377706
24 March 2025
PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8096124
20 June 2024
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7938571
10 May 2024
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7910024
5 May 2024
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7905611
1 May 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7904494
30 April 2024
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7902401
27 April 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7903098
23 April 2024
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7899937
1 August 2022
Deficiency Check · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7519617
22 November 2021
PSC A · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7353829
10 July 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7245898
19 December 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6874541
15 December 2019
ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6873307
28 July 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6493295
27 July 2018
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6489552
26 July 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6496468
29 December 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6330011
4 July 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4073814
7 February 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3941319
1 September 2010
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3839503
12 February 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3679034
28 January 2010
ISPS III Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3671364
29 May 2008
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3221551
27 February 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3154593
27 February 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3158140
29 July 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3010866
28 July 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3010366
18 July 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2999681
19 April 2007
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2910703
18 April 2007
Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2910050
17 April 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2909757
2 August 2006
ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2733875
23 January 2006
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2571597
10 July 2005
ISPS III Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2414080
25 May 2005
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2368044
22 May 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2364892
21 May 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2367061
26 June 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2111310
5 May 2004
MTSA/ISPS Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2060140
13 March 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2023813
14 September 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1904690
14 September 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1904722
15 December 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1720443
31 August 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1670189
31 August 2002
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1686031
23 August 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1665231
21 August 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1664682
20 August 2002
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1664381
30 May 2002
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1621785
22 May 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1733363
22 February 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1724620
31 May 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 290440
9 March 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 275682
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 March 2025
Resolved
07101 The construction of all doors and door frames in "A" class divisions with the means of securing them when closed, shall provide resistanceto fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. PSCO observed door was tampered with a latch as well as missing plates on top and bottom compromising A-60 boundary. PSCO also observed a hole in the door frame of the same door located in the steering gear room adjacent to electrical storage. 74SOLAS(01)II-2/30.2 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2025
Resolved 14 April 2025
Resolution: Class report attesting to repair recieved by USCG
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 23 April 2024
Resolved
Each vessel must have the following: a device that can continuously record the depth readings of the vessel's echo depth sounding device. Prior to arrival the vessel reported an inoperable echo-depth sounding device.
33CFR 164.35(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2024
Resolved 20 June 2024
Resolution: Recieved class survey statement
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 22 November 2021
Resolved
Cargo ships shall carry at least one rescue boat complying with the requirements of Section 5.1 of the code; rescue boats shall have sufficient mobility and maneuverability. PSCO observed rescue boat was unable to pass amidships when turning to starboard. Crew repaired prior to departure.
74 SOLAS (20) III/31.2
LSA Code 5.1.1.7
Action required: 10 - Deficiency Rectified
Resolved 22 November 2021
Resolution: Vessel's crew placed a bolt back to it's original position to allow the outboard motor to function properly.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 22 November 2021
Resolved
Cargo ships when engaged on international voyages shall be fitted with a VDR. PSCO observed two fault codes (174 and 022) on VDR; causing no connection DRV and a bus recover give up (cannot recover DRV and backup HDD.
74 SOLAS (20) V/20.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 November 2021
Resolved 1 August 2022
Resolution: Class report received VDR is now operational and CG examiner verified VDR was operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 November 2021
Resolved
Guard rails shall be fitted around all exposed decks. PSCO observed multiple courses missing.
ICLL (88) I/25.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2021
Resolution: Vessel crew permanently attached the 3 missing courses on the guardrails of the exposed deck.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 22 November 2021
Resolved
Each vessel required to be fitted with an ARPA under 164.38 must be fitted with a device to indicate speed. PSCO observed through review of official logbook that speed log was operating intermediately since 12 NOV 2021.
33 CFR 164.40(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 November 2021
Resolved 1 August 2022
Resolution: Sector San Diego received Class report verifying repair and technician verification.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 22 November 2021
Resolved
The master, owner, operator, agent, or PIC of any vessel equipped with ballast water tank must maintain a ballast water management plan that has been developed specifically for the vessel. PSCO observed that the plan does not state how the vessel will comply with 33 CFR 151.2025 for discharge of ballast water in inside the U.S.
33 CFR 151.2025(g)(2)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2022
Resolution: PSCE verified Ballast management plan has been updated to include discharging procedures while in US waters.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 July 2018
Resolved
Ship's three paralleled gererators were tripped offline when bow thruster neutral gear failed to engage and power to bow thruster excelled.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 December 2019
Resolution: PSC Mobile attended vessel and reviewed class/tech reports attesting to repairs made on box thruster arrangement.
Engineering › Compressed Air System (start air) › Compressor
Issued 28 July 2007
Resolved
Provide operable #1 main air compressor. Currently compressor has a broken coupling rendering it inoperable. The #2 main air compressor is supplying all main engine start air. (Code 15a)
Action required: 705 - Other - as specified
Resolved 31 July 2007
Resolution: Received satisfactory tech report that repairs have been made.
Navigation › Collision/Grounding Avoidance › Radar
Issued 31 August 2002
Resolved
Radar inoperative.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 31 August 2002
Resolution: Necessary repairs made, vsl cleared to sail.
Personnel › Training
Issued 30 May 2002
Resolved
Provide documentation of new crew familiarization training. As per STCW-95 A-VI/1. LEGACY COMPONENT DESC: Familiarization Training
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 June 2002
Resolved 20 August 2002
Resolution: Recieved proff via fax that new crew members were recieving crew familiarization training. Deficiency cleared administratively.
Navigation
Issued 9 March 2000
Resolved
VESSEL HAD NO RECORDER SET UP FOR ECHO DEPTH SOUNDER. VESSEL CORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 March 2000
Resolved 11 March 2000