Inspection history · 33
4 September 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8226683
16 June 2025
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8160259
4 February 2025
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8074344
6 January 2025
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8058855
9 October 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8015616
17 June 2024
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7936875
13 October 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7809341
13 July 2022
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7505515
12 August 2021
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7285554
3 October 2016
Administration
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6027998
11 August 2016
Administration
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5987323
22 July 2016
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5949182
18 January 2013
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4522347
10 March 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3696734
20 April 2009
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3463643
30 November 2007
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3118731
15 December 2006
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2847732
26 January 2000
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1045581
14 December 1999
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 813410
23 May 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 167961
28 March 1997
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1098490
22 December 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 74238
22 December 1995
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1187856
5 January 1995
Type not recorded
No type recorded · District 5 (B) · USCG East District (CGD-E) · Activity 690881
14 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 690882
14 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 708033
14 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 708034
4 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 167948
4 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 213427
23 November 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 180967
23 November 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 187293
10 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 678085
4 May 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 110877
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 September 2025
Resolved
The owner, managing operator, master or officer in charge of a navigational watch of a towing vessel must ensure the following. (c) Emergency procedures related to the tow have been developed and appropriate training provided to the crew for carrying out their emergency duties. Provide emergency procedures for the vessel and post in pilot house.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2025
Resolved 8 December 2025
Resolution: Emergency procedures provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2025
Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location. Pressure vessel for main clutch air not working. Replace Gauge
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2025
Resolved 8 December 2025
Resolution: Gauge replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2025
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use.
(b) If a storage room is provided, it may be any room or compartment that is free of ignition sources.
(c) If a dedicated storage cabinet is provided it must be secured to the vessel so that it does not move and must be either:
(1) A flammable liquid storage cabinet that satisfies UL 1275 (incorporated by reference, see § 136.112 of this subchapter); or
(2) A flammable liquid storage cabinet that satisfies FM Approvals Standard 6050 (incorporated by reference, see § 136.112 of this subchapter); or
(3) Another suitable steel container that provides an equivalent level of protection. Consolidate all flammable liquids in on protected space.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2025
Resolved 8 December 2025
Resolution: Items placed in flame locker.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2025
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. (ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Conduct monthly inspection on portable fire extinguishers.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 3 October 2025
Resolved 3 October 2025
Resolution: Extinguishers Inspected
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 October 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Inverter control station enclosure open and missing closure mechanism. Replace closure device.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 23 December 2024
Resolution: Latches replaced
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 9 October 2024
Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. 03 exterior weather deck lights are not functioning. Replace lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2024
Resolved 6 January 2025
Resolution: 03 lights replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 October 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol. Test strips
expired. Replace strips.
Action required: 705 - Other - as specified
Due 23 October 2024
Resolved 4 February 2025
Resolution: Test strips provided onboard
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 October 2024
Resolved
Marine employers may form or otherwise use sponsoring organizations, or may use contractors, to conduct the random chemical testing programs required by this part. List of currently enrolled members in consortium agreement not on board. Provide confirmation of members
enrolled in agreement.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 23 October 2024
Resolved 23 December 2024
Resolution: Valid Consortium letter provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 October 2024
Resolved
The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. AC generator missing RPM gauge. Install gauge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 February 2025
Resolved 16 June 2025
Resolution: Operator installed required gauge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 October 2024
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10. Portable fire extinguishers not inspected monthly. Inspect and record monthly.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 9 October 2024
Resolved 9 October 2024
Resolution: Inspection report provided along with monthly inspection records
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 October 2024
Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills monthly.
Drills not completed monthly. Complete monthly drills.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 9 October 2024
Resolved 9 October 2024
Resolution: Drills performed and recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 October 2024
Resolved
The owner or managing operator must implement procedures
to identify and mitigate health and safety hazards,
including: sanitation and food handling, noise. Maggot infestation found in crew refrigerator. Noise protection
disregarded and not utilized. Implement measures to provide sanitation for crew and noise protection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 October 2024
Resolved 9 October 2024
Resolution: refrigerator cleaned, hearing protection safety discussed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 October 2023
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. Full records of inspection/testing not on board vessel. Provide records.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2023
Resolved 9 November 2023
Resolution: Fire servicing records received.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 13 October 2023
Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. All crewmembers must be familiar with their fire-fighting duties, and, specifically how to: (1) Fight a fire in the engine room and elsewhere onboard the towing vessel, including how to: (i) Operate all of the fire-extinguishing equipment onboard the towing vessel; (ii) Stop any mechanical ventilation system for the engine room and effectively seal all natural openings to the space to prevent leakage of the extinguishing agent; and
(iii) Operate the fuel shut-off(s) for the engine room.
Master and crew only conducting fire drills once per year. Crew was unfamiliar with required duties. Train crew on all duties, perform drills monthly and record details. Provide to Sector Detroit next fire drill record with required details.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2023
Resolved 9 November 2023
Resolution: Training provided and documented
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 October 2023
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10.
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Crew not performing monthly inspections. Record inspections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2023
Resolved 9 November 2023
Resolution: Monthly inspections conducted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Exhaust leak at #2 DC generator. Secure leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2024
Resolved 20 June 2024
Resolution: Leak repaired with replaced steel segement of exhaust.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2023
Resolved
Machinery and electrical systems must be designed and
maintained to provide for safe operation of the towing
vessel and safety of persons onboard. #1 generator
battery unsecured. Provide enclosure for battery.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2023
Resolved 9 November 2023
Resolution: Battery enclosure provided
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 October 2023
Resolved
All crewmembers must be provided with health and safety information and training. (1) Content and procedures of the owner or managing operator's health and safety plan; (2) Procedures for reporting unsafe conditions; (3) Proper selection and use of PPE appropriate to the vessel operation; (4) Safe use of equipment including deck machinery, rigging, welding and cutting, hand tools, ladders, and abrasive wheel machinery found onboard the vessel; (5) Hazard communication and cargo knowledge; (6) Safe use and storage of hazardous materials and chemicals; (7) Confined space entry; (8)Click to open paragraph tools Respiratory protection; and (9) Lockout/Tagout procedures. Refresher training must be repeated annually. Vessel had no record of initial or refresher training. Train personnel. Record training.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2023
Resolved 9 November 2023
Resolution: Training provided and recorded
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 October 2023
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Charts out of date nor updated. Update/provide new charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2024
Resolved 20 June 2024
Resolution: New electronic chart display installed.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 13 October 2023
Resolved
The officer in charge of a navigational watch must
conduct a navigation assessment for the intended route
and operations prior to getting underway. No assessments
conducted. Conduct assessments.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 9 November 2023
Resolution: Navigation Assessments recorded
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 October 2023
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Multiple expired first aid kits onboard. Dispose and replace of all expired components.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 13 October 2023
Resolved 13 October 2023
Resolution: MI observed crew remove expired medication/first aid items
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 13 October 2023
Resolved
Sufficient lighting suitable for the marine environment must be provided within crew working and living areas. Multiple exterior lights missing globes and guards.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2023
Resolved 9 November 2023
Resolution: Globes and guards provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 October 2023
Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. No plan onboard. Document plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 9 November 2023
Resolution: Maintenance plan created and used.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 October 2023
Resolved
Individuals, who are not crewmembers, on board a towing vessel must receive a safety orientation prior to getting underway or as soon as practicable thereafter, to include: (a) The location, operation, and use of lifesaving equipment; (b) Emergency procedures; (c) Methods to notify crewmembers in the event of an
emergency; and (d) prevention of falls onboard. Provide
orientation to non crew.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 13 October 2023
Resolved 13 October 2023
Resolution: Instructed crew on requirements; Capt. provided basic safety brief
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 October 2023
Resolved
The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine lubricating oil pressure and auxiliary generator engine RPM. #2 generator RPM gauge not functioning. Repair/replace gauge.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2024
Resolved 20 June 2024
Resolution: RPM gauge replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 October 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (1) Main engine low lubricating oil pressure; (2) Main engine high cooling water temperature; (3) Auxiliary generator engine low lubricating oil pressure; (4) Auxiliary generator engine high cooling water temperature; (5) High bilge levels; (6) Low hydraulic steering fluid levels, if applicable; and (7) Low fuel level, if fitted with a day tank. (b) Alarms must: (1) Be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location; (2) Have a means to test actuation at each operating station or have a continuous self-monitoring alarm system which actuates if an alarm point fails or becomes disabled. Operator unable to confirm engine/generator low lube oil pressure and high jacket water temperature alarms function or verify set points of each. No visible alarm, (individual or summary), installed at operating station. Provide visible alarm at operating station and verify function and set points of alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2024
Resolved 20 June 2024
Resolution: Alarm system installed and verified visuale and audible system in wheelhouse.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 July 2022
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase in period. This vessel has not scheduled an inspection or obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection immediately and the vessel may no longer be permitted to operate.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 August 2022
Resolution: COI issued
01 - Certificates & Documentation › 013 - Documents › Records of seafarers' daily hours of work or rest
Issued 13 July 2022
Resolved
THE MASTER MUST KEEP AN ACCURATE LIST OF CREWMEMBERS AND ASSIGNED POSITIONS INCLUDING THE DATE AND TIME THAT A NAVIGATION WATCHSTANDER ASSUMES A WATCH AND IS RELIEVED OF A WATCH MUST BE RECORDED IN THE TOWING VESSEL RECORD.
46 CFR 140.400(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 17 August 2022
Resolution: Reviewed log, vessel does not operate more than 12 hours, no crew changes take place. Crew complement is being logged as well as time vessel gets underway and ties up.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 July 2022
Resolved
CHARTS AND PUBLICATIONS ARE NOT CURRENT.
46 CFR 140.705
Also determined that vessel has an AIS but is not showing up in Marine Traffic. Directed vessel owner to ensure AIS information is properly loaded.
Extending deficiency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 27 October 2022
Resolution: AIS information is displaying properly
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 July 2022
Resolved
VESSEL DOES NOT HAVE THE CAPABILITY TO DISPLAY THREE ALL AROUND LIGHTS IN A VERTICAL LINE (RED, WHITE, RED)
33 CFR 83.27
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 17 August 2022
Resolution: Vessel purchased lights to display as needed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2022
Resolved
VESSEL SHALL BE OUTFITTED WITH 04 LIFEBUOYS, WITH 1 ON EACH SIDE OF THE OPERATING STATION, MINIMUM OF 24" DIAMETERS. AT LEAST 2 OF THESE SHALL HAVE AN APPROVED FLOATING ELECTRIC LIGHT WITH A 3-6' LANYARD SECURED AROUND THE BODY OF THE LIFEBUOY. AT LEAST 1 MUST HAVE A LIFELINE, SECURED AROUND THE BODY. Renew worn grab lines
46 CFR 141.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 17 August 2022
Resolution: All 4 required life buoys are in place and properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2022
Resolved
AN APPROVED LIFEJACKET MUST BE PROVIDED FOR EACH PERSON ON BOARD, PLIS 1 PER WATCHSTANDER LOCATED AT EACH WATCH STATION. LIFEJACKETS MUST BE IN SERVICABLE CONDITION WITH LIGHT AND WHISTLE STOWED IN A READILY ACCESSIBLE LOCATION THAT IS LABELED.
46 CFR 141.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 17 August 2022
Resolution: Lifejackets are labeled and stowed with light and whistle
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2022
Resolved
EACH STORAGE CONTAINER CONTAINING A WORK VEST MUST BE MARKED WORK-VEST. WHEN WORN AT NIGHT, THE WORK VEST MUST BE EQUIPPED WITH A LIGHT.
46 CFR 140.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: Stowage of work vests are seperate and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 13 July 2022
Resolved
THE STOWAGE LOCATION OF IMMERSION SUITS MUST BE MARKED WITH WORDS "IMMERSON SUITS". AND MUST HAVE A LIGHT AND WHISTLE.
46 CFR 141.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: Immersion suits are stowed, labeled, and outfitted with light and whistle.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 13 July 2022
Resolved
A SKIFF MAY BE SUBSTITUTED FOR VESSELS THAT DO NOT OPERATE MORE THAN 3 MILES FROM SHORE. THEY MUST BE CAPABLE OF BEING LAUNCHED WITHIN 5 MINUTES UNDER ALL CIRCUMSTANCES, BE OF SUITABLE SIZE, AND BE MARKED ON EACH SIDE OF THE BOW WITH VESSEL NAME AND PORT ON THE STERN, THE NUMBER OF PERSONS FOR WICH THE BOAT IS EQUIPPED, AND WITH TYPE II REFLECTIVE MATERIAL. THE STOWAGE LOCATION MUST ALSO BE MARKED.
46 CFR 199.176
46 CFR 199.78
46 CFR 141.330
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: Skiff is stowed on aft deck. Discuessed launching procudures and verified labeling.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2022
Resolved
PROVIDE AN APPROVED BRACKET FOR FIRE EXTINGUISHER ON BOTTOM DECK OF ENGINE ROOM
46 CFR 142.300
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 9 August 2022
Resolution: Proper bracket is in place.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 July 2022
Resolved
BILGES ARE TO BE KEPT FREE FROM ACCUMULATING LIQUIDS. ADDRESS AND REPAIR ANY FUEL OR LUBE OIL LEAKS.
46 CFR 142.220
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 17 August 2022
Resolution: A small amount of water is accumulated in the bilge, but oil has been recovered with sorbent pads.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 13 July 2022
Resolved
FLAMMABLE AND COMBUSTIBLE PRODUCTS MUST BE STOWED IN AN APPROVED STORAGE CABINET.
46 CFR 142.225
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 17 August 2022
Resolution: Flammable products have been removed from the vessel.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 13 July 2022
Resolved
THE FOLLOWING SYSTEMS MUST BE EQUIPPED WITH ALARMS: LOW HYDRAULIC STEERING FLUID LEVELS, LOW FUEL LEVEL, HIGH BILGE LEVEL. ALARMS MUST BE VISIBLE AND AUDIBLE AT EACH OPERATING STATION, HAVE A MEANS TO TEST AT EACH OPERATING STATION, CONTINUE UNTIL THEY ARE ACKNOWLEDGED.
46 CFR 143.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: Tested all listed alarms except fuel oil alarm, no means to test. Observed lamp test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 July 2022
Resolved
PRESSURE RELIEF VALVES MUST BE TESTED TWICE EVERY 5 YEARS. VESSEL DOES NOT HAVE INFORMATION ON PRESSURE VESSEL WORKING PRESSURE OR SAFETY VALVE SETTING. DETERMINE THIS INFORMATION AND DEMONSTRATE OPERATION.
46 CFR 143.245
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: New safety valves have been installed on air recievers. Data plates on air recievers are now legible. Verified safety valves setting is at or below MAWP of air reciever. Owner knowledgable of requirement to test twice in 5 years by pressing up tanks
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2022
Resolved
EACH REMOTE FUEL SHUT OFF VALVE MUST BE MARKED IN 1" LETTERS INDICATING PURPOSE AND WAY TO OPERATE IT.
46 CFR 143.260(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: Valves labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2022
Resolved
ELECTRICAL SYSTEMS MUST MINIMIZE FAILURES, FIRE HAZARDS, AND SHOCK HAZARDS. REMOVE ALL DEAD END WIRES, PROVIDE COVERS FOR ALL BATTERIES, ENSURE ALL EQUIPMENT IS MARKED WITH CURRENT AND VOLTAGE RATINGS INCLUDING CIRCUIT BREAKERS AND PANELS. SEE EMAIL LIST
46 CFR 143.400(a)
46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: Circuit breakers and panels are labeled
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 July 2022
Resolved
WATERTIGHT DOORS SHALL BE MARKED "WATERTIGHT DOOR-KEEP CLOSED"
46 CFR 144.160
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: WTD is labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2022
Resolved
DEMONSTRATE DRILLS AND ABILITY TO PUMP OUT BILGE SPACES EITHER BY FIXED OR PORTABLE MEANS
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 17 August 2022
Resolution: Portable pump is stored in the engine room with hoses of appropriate length to pump out each space directly overboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 July 2022
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. Installed battery operatetd detectors meeting UL 217 are accepted and must be kept operational at all times when the crew is on board.
46 CFR 142.330(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: Smoke detectors installed in each berthing space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 13 July 2022
Resolved
Closure devices must be provided for deck house penetrations. Ensure all ventilation closure devices can fully close.
46 CFR 144.320(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 5 August 2022
Resolution: Vent closure for engine room has been repaired.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 July 2022
Resolved
DRILLS MUST TAKE PLACE ON THE VESSEL WITH PARTICIPATION BY ALL CREWMEMBERS WITH ACUTAL USE OF EMERGENCY EQUIPMENT. RECORDS MUST BE KEPT IN THE TVR WITH THE DATE, DESCRIPTION OF SCENARIO, INSTRUCTION TOPICS, AND PERSONNEL INVOLVED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2022
Resolved 17 August 2022
Resolution: Observed satisfactory MOB drill, and logs with appropriate information.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 13 August 2021
Resolved
Provide proof of enrollment in a random drug testing program in accordance with 46 CFR 16.230 for all employed members prior to vessel operation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 January 2022
Resolution: Verified enrollment.