Records from 1984 to 1995. Most recent: inspection, 27 November 1995.
Inspection history · 26
27 November 1995
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1185223
30 March 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 80283
3 January 1995
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 855667
11 May 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1170349
20 April 1994
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1170456
8 April 1994
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1167514
7 April 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 61802
11 March 1994
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1165538
25 January 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 853216
13 December 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849134
4 March 1993
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 832460
9 August 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 178599
15 January 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1266545
10 May 1991
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1214261
7 January 1991
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 933460
23 February 1990
Examination of Repairs · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1242185
11 January 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 930047
11 January 1988
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1324726
22 June 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013745
5 June 1987
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1004705
19 December 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1000498
12 January 1986
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 995094
11 April 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 980870
17 December 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 976617
31 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976544
27 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972407
Engineering
Issued 3 January 1995
Resolved
Repair low lube oil shutdown relay servicing main generator & demonstrate operation.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Fire Fighting
Issued 3 January 1995
Resolved
Service portable fire extinguishers.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 8 April 1994
Resolved
Make permanent repair by insert to the satisfaction of the cognizant OCMI. At 12 hour intervals sound #1 starboard ballast tank and log result until repairs commence.
Condition: Unknown
Due 8 April 1994
Resolved 8 April 1994
Construction/Loadline
Issued 13 December 1993
Resolved
Renew hatch dog padeye 4th in from port side #4 coaming.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 13 December 1993
Resolved
Renew hatch dog padeye 3rd padeye in from stb #4 coaming.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 13 December 1993
Resolved
Renew hatch dog padeye - aft #2 coaming six in from starboard.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Engineering
Issued 13 December 1993
Resolved
Free up cargo hold suction valves under generator switch board.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 13 December 1993
Resolved
Renew in kind the fore and aft hatch cover coaming brackets entirely from port to stbd at next drydock.
Condition: Unknown
Due 7 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 December 1993
Resolved
Make temporary repairs to all for and aft hatch cover brackets on the fore and aft sides of all 6 hatch coamings.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 13 December 1993
Resolved
Install 3 U bolts aft #1 cargo hold.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 13 December 1993
Resolved
Renew/repair watertight door to machinery space.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Deck/Cargo
Issued 13 December 1993
Resolved
Renew goose neck vent port side forward - just aft of cleat.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 13 December 1993
Resolved
Renew aft hatch on generator air intake trunk.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 13 December 1993
Resolved
Renew deck hatch between #1 & #2 cargo holds.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Deck/Cargo
Issued 11 January 1990
Resolved
MAKE PERMANENT REPAIRS TO ALL GOOSENECK VENTS. THIS REQUIREMENT TO BE COMPLETED NO LATER THAN 11FEB90.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Construction/Loadline
Issued 11 January 1988
Resolved
REPAIR OR REPLACE THE WATERTIGHT DOOR TO THE FORWARD MACHINERY SPACE.
Condition: Unknown
Due 11 January 1988
Resolved 11 January 1988
Deck/Cargo
Issued 5 June 1987
Resolved
PROCURE AND INSTALL TACHOMETER ON GENERATOR AND TEST OVERSPEED TRIPS.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Deck/Cargo
Issued 5 June 1987
Resolved
INSTALL MISSING JUNCTION BOX COVER ON ANCHOR WINDLESS MOTOR.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Electrical
Issued 5 June 1987
Resolved
INSTALL GLOBE COVERS AND CAGES TO PROTECT LIGHT FIXTURES IN GENERATOR ROOM.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Fire Fighting
Issued 5 June 1987
Resolved
HAVE FIRE EXTINQUISHERS SERVICED.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Accommodation/Occupational Safety
Issued 5 June 1987
Resolved
REPAIR HANDRAILS ON STARBOARD SIDE.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Deck/Cargo
Issued 19 December 1986
Resolved
REMOVE FUEL FROM DRIP PAN UNDER GENERATOR AND FIX LEAKS. BY 25DEC86.
Condition: Unknown
Due 19 December 1986
Resolved 19 December 1986
Electrical
Issued 19 December 1986
Resolved
REMOVE OLD BATTERIES FROM VESSEL. BY 25DEC87.
Condition: Unknown
Due 19 December 1986
Resolved 19 December 1986