MAURY USCG vessel records Sign in
← All vessels

SILVER LAKE

SILVER LAKE is a 1965 passenger vessel (inspected). The Coast Guard has recorded 247 inspections since 1984, most recently in July 2026, along with 239 deficiencies and 39 casualty investigations between 2002 and 2026.

Records from 1984 to 2026. Most recent: inspection, 3 July 2026.

Built
1965
Last inspected
3 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8643236 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WV5661
Flag
UNITED STATES
366977070
Maury page id
psix-45005

Inspections, by type

…with no type recorded71
Years with a record 41 calendar years (1984–2026)
The 247 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)207.8 ft × 38.0 ft × 12.5 ft
Registered tonnagegross 688 / net 469
ITC dimensions (L × B × D)207.8 ft × 38.0 ft × 12.5 ft
ITC tonnagegross 1,132 / net 364
BuilderNEW BERN SHIPYARD INC. · NEW BERN, NC, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMANNS HARBOR, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1132 - Convention (Subpart B), Gross Ton
688 - Regulatory (Subpart C or D), Gross Ton
364 - Convention (Subpart B), Net Ton
469 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WV5661MMSI 366977070 · active · compulsorily equipped · granted 21 August 2024, expires 5 October 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA LEVEL Passenger (Inspected) · MISLE 43775 · 13 February 2017 · activity 6102743CARTERET Passenger (Inspected) · MISLE 306170 · 10 December 2002 · activity 1717165DARE Towing Vessel · MISLE 461061 · 8 July 1997 · activity 83051

Inspection history · 247

3 July 2026 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8426866
3 July 2026 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8431377
25 June 2026 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8412142
13 January 2026 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8295454
24 July 2025 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8193700
11 July 2025 Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8183074
9 July 2025 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8180694
9 July 2025 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8280108
24 April 2025 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8119900
9 April 2025 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8109552
1 April 2025 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8103486
7 March 2025 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8089845
6 March 2025 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8104057
15 January 2025 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8063774
30 November 2024 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8041381
30 November 2024 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8056731
24 October 2024 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8022028
25 July 2024 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7966072
24 April 2024 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7900528
1 February 2024 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7858722
30 December 2023 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7843620
26 December 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7842482
27 October 2023 COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7809217
23 February 2023 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7640958
13 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7557842
10 August 2022 COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7524133
4 July 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7495774
4 July 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7507501
20 May 2022 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7458198
16 May 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7452109
13 May 2022 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7450135
5 May 2022 Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7439846
1 March 2022 Deficiency Check · Special
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7404659
10 February 2022 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7392003
8 January 2022 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7377726
18 November 2021 Re-Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7352891
17 October 2021 Special · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7334875
12 August 2021 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7272624
3 August 2021 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7276327
6 May 2021 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7189932
1 March 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7148355
12 February 2021 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7139908
4 February 2021 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7136006
4 February 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7148869
8 January 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7121539
8 January 2021 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7121590
16 November 2020 Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7097534
2 November 2020 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7092268
31 October 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7101499
30 October 2020 MTSA Verification · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7087207
2 September 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7055357
27 August 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7044779
14 August 2020 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7031689
25 October 2019 Damage Survey · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6842263
25 July 2019 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6656652
19 July 2019 MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6768478
13 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6721327
7 January 2019 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6606787
19 November 2018 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6584020
15 August 2018 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6513301
8 August 2018 MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6449630
9 July 2018 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6488422
17 June 2018 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6449112
10 May 2018 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6373233
21 February 2018 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6358716
14 December 2017 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6324342
4 December 2017 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6319852
20 November 2017 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6310943
11 September 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6264608
12 July 2017 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6168143
19 April 2017 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6104369
13 February 2017 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6102743
18 January 2017 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6056921
13 October 2016 Administrative Inspection · COI Inspection · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6021597
7 July 2016 Damage Survey · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5932789
5 April 2016 Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5848430
22 March 2016 Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5838038
9 March 2016 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5810228
22 February 2016 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5824999
22 February 2016 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5843452
9 December 2015 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5756465
12 August 2015 MTSA Verification · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5214153
25 July 2012 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4390464
18 June 2012 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4348289
13 June 2012 Periodic Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4299287
5 May 2012 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4303335
1 August 2011 COI Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4101873
25 July 2011 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4093856
15 July 2011 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4082175
6 January 2011 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3922031
9 February 2010 MARPOL Annex I Examination · MTSA Verification · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3677358
24 January 2010 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3669257
12 December 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3649712
9 December 2009 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3638307
27 February 2009 Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3425033
11 January 2009 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3393331
9 January 2009 Drydock Extension
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3398147
17 December 2008 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3381823
16 December 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3380469
21 November 2008 Deficiency Check · Administrative Inspection · Inclining Experiment
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3367225
27 October 2008 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3352349
10 September 2008 COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3322011
10 June 2008 Periodic Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3224834
5 March 2008 Spot Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3159445
23 March 2007 Inclining Experiment · Examination of Repairs · COI Inspection · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2893632
7 January 2007 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2910030
23 October 2006 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2826192
6 September 2006 Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2772274
27 June 2006 Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2692985
6 May 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2644014
4 May 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2641653
3 May 2006 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2639274
1 May 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2638581
1 April 2006 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2619332
14 March 2006 MTSA Verification · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2602429
15 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2534146
4 October 2005 MTSA Verification · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2508179
19 July 2005 MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2436000
13 April 2005 COI Inspection · MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2332814
23 November 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2250239
17 May 2004 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2063973
22 April 2004 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2063946
31 March 2004 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2225274
14 December 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1999521
8 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961082
8 April 2003 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1777449
19 February 2003 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1746380
10 December 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1717165
17 October 2002 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1693954
11 October 2002 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1688333
9 October 2002 Damage Survey
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1688301
1 October 2002 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1685955
23 April 2002 Internal Structural Exam · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1608386
29 March 2002 Deadweight Survey · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1599782
3 October 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1401567
8 August 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1425177
18 April 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1063204
10 April 2001 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1410533
8 September 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1421973
28 August 2000 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1053200
26 May 2000 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1470264
28 May 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 136553
24 May 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1464845
1 April 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1397119
25 March 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1464173
17 December 1998 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1442776
10 September 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1421553
8 August 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 81739
20 June 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1126169
19 March 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1110812
25 December 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 167917
21 December 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 137064
19 December 1997 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 781175
21 November 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 774150
18 November 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 82941
2 October 1997 Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1121308
17 September 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 660722
23 August 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1121122
22 August 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 74979
18 August 1997 Re-Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 784407
15 August 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 214451
8 July 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 83051
8 July 1997 Deficiency Check · Damage Survey
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1114281
7 May 1997 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1093523
19 March 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1407850
23 January 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1374879
18 January 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 5494
15 January 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 142842
2 January 1997 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1095970
3 October 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1149549
24 July 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1392520
2 April 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1079007
5 January 1996 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1191588
25 November 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2051
31 October 1995 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 878930
13 September 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 876916
8 August 1995 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 882606
9 June 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 34165
8 June 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1185654
3 May 1995 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422507
5 January 1995 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1166567
20 October 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1171732
28 August 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 170739
27 July 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 80390
5 July 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 97782
30 June 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 13639
29 June 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1136835
23 May 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 154107
5 April 1994 COI Inspection · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1167485
5 March 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 33034
26 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1162443
12 January 1994 Examination of Repairs · Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1420826
24 December 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 157129
6 July 1993 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 846530
29 June 1993 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 846133
25 June 1993 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 844971
24 June 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 144371
14 June 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 4881
22 April 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 128411
8 April 1993 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1139833
5 April 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1153180
25 February 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 154607
27 December 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 3967
26 December 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 93957
15 December 1992 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 826032
24 November 1992 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 828077
16 October 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 158041
14 October 1992 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1249212
8 July 1992 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1256964
20 April 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 55881
16 April 1992 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1257770
16 March 1992 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1265354
8 January 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 110450
31 December 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 95327
12 December 1991 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 946377
5 November 1991 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 938797
22 October 1991 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 942692
20 September 1991 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1243704
8 May 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1231544
7 May 1991 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 921902
6 November 1990 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1228893
16 May 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 899900
15 May 1990 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1219682
8 January 1990 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 899776
28 November 1989 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 923465
11 July 1989 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1352100
12 June 1989 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 895701
6 December 1988 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1209051
8 November 1988 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1203393
18 July 1988 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1032307
21 June 1988 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 896294
7 June 1988 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1201963
13 January 1988 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1321973
2 November 1987 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1330600
8 October 1987 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1012536
27 June 1987 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1019203
8 June 1987 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1335541
14 May 1986 Credit Drydock
Administrative · THE UNKNOWN UNIT · Activity 1300157
1 April 1986 COI Inspection
Physical examination · THE UNKNOWN UNIT · Activity 1306629
9 October 1985 Re-Inspection
Physical examination · THE UNKNOWN UNIT · Activity 1300227
21 August 1985 Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 988749
16 July 1985 Re-Inspection
Physical examination · THE UNKNOWN UNIT · Activity 983273
9 May 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 979657
5 April 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 978014
5 April 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 979227
19 October 1984 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 974495
19 October 1984 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 976365

Deficiency record · 239

03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 24 July 2025 Resolved
Manholes and flush scuttles in position 1 or 2 or within superstructures other than enclosed superstructures shall be closed by substantial covers capable of being made watertight. Emergency escape scuttles in the engineroom and bow thruster room were found leaking. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2025
Resolved 22 August 2025
Resolution: Gaskets replaced with new
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 July 2025 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness. Coast Guard was notified that the SELVER LAKE found a 2 inch crack in the aft void just forward of the steering compartment. Conduct repairs and test to the satisfaction of attending CG Marine Inspector prior to carring passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2025
Resolution: Vessel attended Manns Harbor for crop and renew of plate. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 March 2025 Resolved
Searching for damage after hard grounding.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 31 March 2025
Resolved 14 March 2025
Resolution: Replaced bow thruster keel cooler, no other damage identified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 October 2024 Resolved
Bilge system must be capable of pumping from and watertight compartment. VSL bow thruster space bilge suction is inoperable. Make repairs and prove proper operation of bilge pumping capabilities.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 October 2024 Resolved
Bilge system must be capable of pumping from any watertight compartment. Fuel tank space bilge suction is operating slowly and not required gallons per min. Make repairs and prove proper operation to attending CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 November 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2024 Resolved
Complete but simple instructions for operation of the system must be located in a conspicouse place at CO2 cylinder storage room. Current instructions state 30 secound for time delay and actual time delay is 25 seconds. Change instructions to match system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2024
Resolved 25 November 2024
Resolution: Objective evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2024 Resolved
Before the vessel leaves port and at all times during the voyage, each life saving appliance must be in working order. All life jackets on 01 deck exposed to weather were found covered with black mold. 96 Adult and 56 child life jackets are unservicable condition. Clean or relace life jackets on 01 deck to the satisfaction of attending CG Marine Inspector. passenger count reduced to 204 adult and 20 children until cleared.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 December 2023 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. Vessel stated they experienced a bump and go at 1815 on 29DEC23 IVO 10A in big foot slough. Crew discovered during morning checks that port rudder stock was raised 2-3". Captain is requesting to deadhead to Cedar Island for divers inspection of running gear. Vessel is approved for one time dead head to Cedar Island. Provide proof to the attending MI that repairs have been completed.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2023
Resolution: NCDOT had divers inspect the hull. No damages to note at this time. Captain provided attestation letter. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 December 2023 Resolved
The vessel's main steering gear and rudder stock must be of adequate strength and capable of steering the vessel at maximum ahead service speed. The SILVER LAKE is unable to adequately maneuverer. Ensure rudder is capable of moving from 35 degrees on one side to 30 degrees on the opposite side (at max service speed) within 28 seconds.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 December 2023
Resolved 8 January 2024
Resolution: Valve on hydraulic pump set in correct position.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 27 October 2023 Resolved
Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering compartment. Rudder angle indicator is off by 7 degrees in the pilothouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 1 February 2024
Resolution: Conducted steering test and verified all Rudder Angle Indicators properly working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 October 2023 Resolved
Vital systems that are automatically or remotely controlled must me provided with - (1) An effective primary control system... Port and Stbd mde throttle controls are extremely mismatched; port engine at wot is 100 rmp below stbd.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2023
Resolved 1 February 2024
Resolution: Port and Stbd rpm indiccators properly synched up.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 September 2022 Resolved
PASSENGER VESSELS OVER 500GT MUST CARRY ON EACH SIDE OF THE VESSEL AT LEAST ONE RESCUE BOAT. VSL HAS ONLY ONE RESCUE BOAT INSTALLED. VSL MUST PROVIDE SECOND RESUCE BOAT OR AN APPROVED EXEMPTION LETTER FROM THE OCMI. 46 CFR 199.202
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2022
Resolved 4 October 2022
Resolution: Received approval letter from PDH approving single rescue boat arrangement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 July 2022 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of a vessel or the efficiency or completeness of its life-saving appliances, fire-fighting, or other equipment. Master reported they dropped a valve on the starboard engine's #8 cylinder. Make permanent repairs to starboard engine. Provide technicians/mechanics report of findings and repair. Prove proper operation of starboard engine to the satisfaction of the attending USCG Marine Inspector. Vessel is authorized one-time transit without passengers from Ocracoke, NC to Cedar Island, NC to effect repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 July 2022
Resolved 4 July 2022
Resolution: Received email from technician stating the rocker arm on top of the exhaust valves for the #1 cylinder were found damaged and replaced. Technician adjusted all valves to specifications and master provided attestation after satisfactory sea trails.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2022 Resolved
A survey shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. Maintenance crew reported to the USCG that approximately 1" of standing water was found in the steering compartment during daily crew checks. Sea trials were conducted and excessively water leaking was verified coming from the top of the port rudder tube. Determine cause of leak and make effective repairs to the attending Marine Inspector prior carrying passengers/cargo.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2022
Resolution: USCG Marine Inspector attended vessel and witnessed install of new bushing, sea trials conducted sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2022 Resolved
A survey shall be made every time a defect is discovered which affects the safety of the vessel. During re-inspection C/E reported port rudder post leaking. MI's verified port rudder excessively leaking during steering test at hard starboard. Make effective repairs prior to carriage of passengers/cargo.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2022
Resolution: New rudder bearing installed, bearing retainer ring properly installed operational testing SAT not water ingress at time of inspection at full thrust full port or stbd.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 5 May 2022 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed dangerous places such as gears, machinery, etc. MI discovered port and starboard alley spaces with no guards.
Action required: 10 - Deficiency Rectified
Resolved 5 May 2022
Resolution: NCDOT maintenance installed rails and chains to prevent entanglement. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 March 2022 Resolved
Cooling water expansion joint on Port Side MDE has pin hole leak, replace and test to the satisfaction of the attending Marine Inspector iaw 46 CFR 46 CFR 58.05-1.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2022
Resolution: MI's verified repairs were conducted IAW 835. All SAT
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 10 February 2022 Resolved
Vessel must comply to requirements issued by the FCC. Prove the DSC function of the radio is operational with vessels MMSI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 18 February 2022
Resolution: Vessel completed MMSI test of the radio. All SAT
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 10 February 2022 Resolved
An EAP training program must be conducted for employers supervisors. Captain has not conducted training.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 18 February 2022
Resolution: Captain provided proof of training. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 10 February 2022 Resolved
The damper shall be made accessible for periodic inspection by means of a hinged or bolted plate in the duct. Two dampers had bolts missing and/or loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 18 February 2022
Resolution: NCDOT maintenace installed two new bolts; all SAT
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 February 2022 Resolved
Cylinders shall be securely fastened and supported to protect against injury. NO. 9 F/F extinguisher bracket is deteriorated/corroded. Replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 18 February 2022
Resolution: NCDOT maintenance replaced with in kind bracket.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 January 2022 Resolved
All emergency equipment shall be maintained in an operative condition. Received a call from NCDOT stating block heater was leaking on emergency gen from tale/tale nipple fitting. NCDOT will replace fitting in kind and provide CG with documentation that repairs were made prior carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2022
Resolved 8 January 2022
Resolution: NCDOT replaced fitting in kind. Captain provided before and after photos of part and provided CG with attestation letter for files. See documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2021 Resolved
Fire extinguishers must be classified. M/I discovered extinguishers #8, 11, and 15 are not IAW requirement per Certificate of Inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 1 December 2021
Resolution: Replaced fire extinguisher with the correct type iaw certificate of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 18 November 2021 Resolved
A survey, either general according to the circumstances, shall be made every time an accident occurs or a defect is discovered. During op test of the rescue boat, the aft lower prop guard made contact and damaged the guard. Additionally, upon further evaluation the cradle pins need to be modified, as well as the bumpers need to be modified to prevent aft rescue boat from hanging up.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 1 December 2021
Resolution: The rescue boats cradle bumper was properly adjusted. Additionally, a retainer was added on the foot catch to prevent premature release, and the worn straps were replaced in kind.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2021 Resolved
Circumstances, shall be made every time an accident occurs or a defect is discovered. MI discovered (04) four portable fire extinguishers hose were missing static testing labels.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 1 December 2021
Resolution: Vessel crew replaced the non-compliant extinguishers and tested/tagged the horns for conductivity.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2021 Resolved
A survey, either general shall be made every time an accident occurs or a defect is discovered or import repairs are made. MI noted an inset approx. six foot ivo port bow bulwark. One stanchion is tripped, the damaged area was not reported. Provide repair plan to satisfaction of Coast Guard. See AN 7352891 and special note for details.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 3 October 2023
Resolution: Completed repairs during shipyard period, cropped and renewed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 18 November 2021 Resolved
Where fitted, the complete loud speaker system shall be tested during spot test of speaker system. The mic was not working as designed.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 18 November 2021
Resolved 18 November 2021
Resolution: Crew replaced microphone and tested to the satisfaction of the attending inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 October 2021 Resolved
Vessel has approx. 1/4 inch hole on bow thruster. Ensure proper repairs are performed prior to carrying passengers. Prior to movement to NCDOT Shipyard captain must establish periodic checks of space at intervals sufficient to ensure safety of the vessel crew. Repair in accordance with 46 CFR 72.01-15.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2021
Resolution: Repairs complete and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 August 2021 Resolved
The sprinkler system shall be so designed and arranged that the overhead is effectively sprayed and all portions of the deck are covered. During test MI witnessed two nozzles on the starboard side forward inoperable. Renew nozzles and prove proper operation. Replace other nozzles as needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2021
Resolved 13 August 2021
Resolution: The 06 sprinkler heads in question were renewed and all other were inspected. System was tested by the maintenance supervisor and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 August 2021 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with mat black inboard screens and meet the requirements of 33 CFR 84.15. Port and Starboard running lights were not properly installed with mat black screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2021
Resolved 26 August 2021
Resolution: Screens were properly painted with matte black.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 August 2021 Resolved
The installation of all systems of a marine engineering nature together with the details off design, construction and installation shall be in accordance with the requirements of subchapter F. Pressure fuel piping not properly secured on the portside generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 August 2021
Resolution: Piping was renewed and properly secured to eliminate vibrating and chafing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 August 2021 Resolved
Bow thruster is inoperable
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2021
Resolution: Air was bled from the fuel lines and the fuel injector was replaced. MIs received a tech report from NCDOT attesting to the proper operation of the vessel's bow thruster.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2021 Resolved
Port and starboard aft outboard fire dampeners are not closing as designed.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2021
Resolution: Fire dampeners were adjusted and are now closing as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021 Resolved
The emergency generator starter wire was loose.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 May 2021
Resolution: Wire was tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2021 Resolved
The #2 main Diesel engine over speed air dampener was inoperative after testing.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 6 May 2021
Resolution: Proved proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 May 2021 Resolved
Emergency generator battery charger panel cover is not secure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 May 2021
Resolution: Panel cover was properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
Properly secure electrical terminal underneath bridge console, starboard access panel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 14 May 2021
Resolution: Terminal was properly mounted underneath the console.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2021 Resolved
The engine room life jackets were stowed in the wrong location.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 May 2021
Resolution: Lifejackets properly stowed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2021 Resolved
The #2 main Diesel engine has an exhaust leak at the turbo bowel.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2021
Resolution: Engine exhaust was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2021 Resolved
The engine room CO2 hose reel has a broken fitting rendering it inoperative as designed, in the event of fire.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 6 May 2021
Resolution: CO2 hose reel fitting was properly repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 May 2021 Resolved
The main deck life jacket stowage sliding door is not operating properly. Conduct maintenance and prove proper operation is as designed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2021
Resolution: Lifejacket stowage compartment sliding door is now fully functional.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2021 Resolved
The engine room crew were not familiar with the fixed CO2 system. Crew training was conducted to the satisfaction of the attending inspector.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 May 2021
Resolution: Conducted training.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 6 May 2021 Resolved
The engine room bulkhead aft port side has 2” hole, provide repair plan.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2021
Resolution: Provided accepted plan for making temporary repairs on the bulkhead.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2021 Resolved
The handle on exterior of embarkation for rescue boat is loose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2021
Resolution: Handle was properly tightened.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 February 2021 Resolved
Rescue boat remote lowering cable handle fell off while lowering. Make proper repairs and prove proper operations.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 February 2021
Resolution: Handle was reinstalled and tighted and tested SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 February 2021 Resolved
Permantly secure drinking machines in passengers compartment with additional brackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2021
Resolution: New brackets installed on top and bottom of machines.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 February 2021 Resolved
WTD #3 loose doggs, adjust for proper operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 February 2021
Resolution: The door dogs were adjusted and tested.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 February 2021 Resolved
WTD to engine room loose doggs adjust.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 February 2021
Resolution: Adjusted and tested SAT.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 February 2021 Resolved
EDG breaker doesn't match indicator (labels)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2021
Resolution: Properly marked and confirmed labels.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 February 2021 Resolved
Both SSDG J/W elbows missing lagging
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2021
Resolution: Received, reviewed, and accepted e-mail with photos as objective evidence satisfying the outstanding requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 February 2021 Resolved
STBD MDE R/G air control has damged hose/cracked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2021
Resolution: Received, reviewed, and accepted e-mail with photos as objective evidence satisfying the outstanding requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 February 2021 Resolved
Port SSDG f/o line missing hold down bracket.
Action required: 10 - Deficiency Rectified
Resolved 17 February 2021
Resolution: nuts and bolts added to bracket and tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 February 2021 Resolved
Port MDE overspeed indicator light no operational.
Action required: 10 - Deficiency Rectified
Resolved 17 February 2021
Resolution: Switch was shorted. Rewired and tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 February 2021 Resolved
Bow thruster port side actuator valve packing leaking when operated. Remove water from bilge and log in engieering log until fixed.
Action required: 705 - Other - as specified
Due 20 February 2021
Resolved 18 November 2021
Resolution: Crew replaced actuator and removed water from bilge. MI inspected actuator while operating bow thruster under normal conditions during a Re-Inspection (AN: 7352891). All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 17 February 2021 Resolved
Passenger compartment. Remove tiles, grind unused broken bolts and renew tiles on deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2021
Resolution: Removed tripping HAZ and installed new tiles
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 February 2021 Resolved
Throuble shoot and make permanent to the steering system following loss of steering while caring passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2021
Resolution: Contactor replaced all TEST SAT. Objective evidence collected from vsl CAPT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 January 2021 Resolved
Master reported, the vessel experienced a failure of the starboard vulkan coupling. While underway from Ocracoke to Cedar Island during operations with passengers and vehicles this date. Determine the cause of failure and make proper repairs to the satisfaction of the Coast Guard. Prior to the carriage of passengers or cargo. The vessel was authorized one time transit to from Ocracoke to Cedar Island for repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2021
Resolved 9 January 2021
Resolution: New coupling installed and tested during underway sea trails.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2020 Resolved
Provide additional life jacket donning placard for upper deck.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 17 November 2020
Resolution: Provided additional donning placard
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2020 Resolved
Repair hinges on all life jacket benches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 18 November 2020
Resolution: All hinges were properly repaired and inspected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 November 2020 Resolved
Replace forward and aft cargo nets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 23 November 2020
Resolution: Cargo nets were replaced with new ones.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 November 2020 Resolved
Verify and place markings on all emergency hatches.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2020
Resolved 17 November 2020
Resolution: Markings are on all applicable emergency hatches.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 13 November 2020 Resolved
Port and starboard seachest had pin holes and was leaking. Make effective repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: Leaks were properly repaired. Sections of the piping were replaced on port and starboard seachest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2020 Resolved
Bilge system overboard discharge leaking. Make effective repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: The leaking pipe on bilge overboard was properly repaired. Section of pipe was replaced with new.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 November 2020 Resolved
Verify and tighten pilot valves on both CO2 systems.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2020
Resolution: Pilot valves were properly tightened.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 November 2020 Resolved
Missing medictaion in first aid kit.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 13 November 2020
Resolution: Placed missing items back in first aid kit.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 November 2020 Resolved
Loose bracket/nozzle on CO2 piping IVO aft port engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2020
Resolved 17 November 2020
Resolution: Bracket was properly tightened.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 November 2020 Resolved
Bow thruster and EDG CO2 pilot valves were loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 November 2020
Resolution: Pilot valve was properly tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 November 2020 Resolved
Bow thruster clutch oil pressure switch is leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: Pressure switch was replaced and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2020 Resolved
MSD space hot water heater and hydro tank are damaged. Renew
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2020
Resolved 10 December 2020
Resolution: Water heater and hydro tank was replaced and properly installed.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 November 2020 Resolved
MSD discharge pipe to skin valve is loose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2020
Resolution: The discharge piping clamp was tightened up.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 November 2020 Resolved
MSD pump is leaking at discharge flange.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: The pump flange was tightened and visually inspected to ensure the leak has stopped.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 November 2020 Resolved
MSD room hull anode piping on portside is damaged. Cap is required or replace in kind.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 13 November 2020
Resolution: The piping was properly capped.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 November 2020 Resolved
CO2 MSD room watertight door had hold back
Action required: 10 - Deficiency Rectified
Resolved 13 November 2020
Resolution: Hold back was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 November 2020 Resolved
Inspect and renew the tiller arm clamp with flanges. Found crack. Test shall made to prove repairs to the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: The tiller clamp was properly repaired, installed and tested during sea trial.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 13 November 2020 Resolved
Submit repair plan for tripping hazard IVO passenger lounge
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2020
Resolution: Tripping hazard was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2020 Resolved
Replace man overboard cleats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2020
Resolved 11 December 2020
Resolution: Cleats were replaced with metal ones.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 August 2020 Resolved
Remote propulsion control for port MDE is inoperable; overspeed shutdown not tripping intake air flap. Identify cause and make repairs iaw 46 CFR 62.35-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2020
Resolution: Worn bushing found in air flap assemble. Assembly replace; op test sat.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 14 August 2020 Resolved
All shaft tachometers are inoperable or a reversed, make repairs to all iaw 46 CFR 113.37-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2020
Resolution: Magnetic pickups adjusted and the tachs are now functioning properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 August 2020 Resolved
Provide evidence of testing and/or renewal of fixed CO2 hoses iaw 46 CFR 78.17-18 and 46 CFR 76.05-20.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2020
Resolution: NCDOT QA provided proof of testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2020 Resolved
Multiple exhaust leaks throughout the engine space, mitigate to prevent iaw 46 CFR 58.05-1.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2020
Resolution: Satisfactorily resolved and witnessed corrected during attendance.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 August 2020 Resolved
Public address system is inoperable on starboard astern and forward, repair iaw 46 CFR 113.50-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2020
Resolution: Satisfactorily resolved and witnessed corrected during attendance.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 14 August 2020 Resolved
Watertight door indicator for door #2 is inoperable. Make repairs iaw 46 CFR 170.270.
Action required: 705 - Other - as specified
Due 11 September 2020
Resolved 9 September 2020
Resolution: The watertight indicator was replaced with new.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 August 2020 Resolved
Multiple lights on the vessel that are used for emergency are not marked, provide markings iaw 46 CFR 78.47-33.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2020
Resolution: Satisfactorily resolved and witnessed corrected during attendance.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 14 August 2020 Resolved
Window in aft steering compartment is cracked, replace with new iaw 46 CFR 72.05-30.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2020
Resolution: Satisfactorily resolved and witnessed corrected during attendance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 August 2020 Resolved
Replace cracked instake air filter elbows on the port and starboard MDE iaw 46 CFR 58.05-1.
Action required: 705 - Other - as specified
Due 11 September 2020
Resolved 9 September 2020
Resolution: The intake filter elbows were replaced with new.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 14 August 2020 Resolved
Bow thruster and MDE control indicator light in pilot house is inoperable or too dim to see, replace/repair iaw 46 CFR 113.37-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 August 2020
Resolution: Satisfactorily resolved and witnessed corrected during attendance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 July 2019 Resolved
The EDG racor had a major fuel oil leak when tested.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2019
Resolved 25 July 2019
Resolution: Maintenance personnel made repairs and tested to the satisfaction of the attending M/I.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2019 Resolved
Both port & starboard SSDG's & MDE's fuel oil supply hoses are cracked and damaged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: New hose installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2019 Resolved
The aft portable CO2 extinguisher was damaged.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2019
Resolved 25 July 2019
Resolution: Maintenance personnel replaced with new extinguisher to the satisfaction of the attending M/I.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2019 Resolved
The port aft embarkation light on vehicle deck was missing.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: Light is operational
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 July 2019 Resolved
The aft goose necks for void spaces are wasted on the starboard side. To be repaired at next drydock (Sept 2019)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 August 2020
Resolution: Goosenecks have been replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 July 2019 Resolved
The bow thruster accuator has missing dust cover.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: Cover installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 July 2019 Resolved
The starboard resilant mounts for gauges are damaged.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: New mounts installed
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 July 2019 Resolved
The galley self closing door is not operating properly.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: Door test SAT
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 25 July 2019 Resolved
The crew berthing and passenger lounge has loose and damaged tiles, creating slips and trips hazards.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: Gear stowed and new tile floor replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2019 Resolved
The port and starboard propellers have reported damage and caused excessive vibration to vessel during operation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 31 July 2019
Resolution: The OCMI provided consideration to allow the vessel to operate until its dry dock (Sept19).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 January 2019 Resolved
Renew wasted EDG fuel piping & attached hoses at the next DD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 10 August 2020
Resolution: Fuel lines have been renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2019 Resolved
Correct vibration issue IWO propulsion shafting which occurs during light deck loads & shallow water. Provide dive report & report of tailshaft alignment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 May 2019
Resolved 15 August 2020
Resolution: Extensive repairs were made to vessel during credit dd 2020. Propulsion shaft run-out reading look good and sea trials conducted satifactory.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 October 2018 Resolved
#4 Life raft (IBA) hydro is not marked on expiration.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2018
Resolved 9 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 24 October 2018 Resolved
Rescue boat ladder was found damaged during COI.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2018
Resolved 9 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2018 Resolved
Bow thrusters emergency stop button was inoperative when tested during COI.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 November 2018
Resolved 26 October 2018
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 24 October 2018 Resolved
Several tiles in the (02) passenger lounge are damaged, creating slips, tripping, and falling hazards.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2018
Resolved 9 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 24 October 2018 Resolved
The vessels aft fire pump and sprinkler system could not provide pressure as designed during COI when tested.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2018
Resolved 26 October 2018
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 17 June 2018 Resolved
Volton frive coupling in stbd clutch failure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2018
Resolution: Replaced drive coupling in stbd clutch all sat as per written statement from [name withheld].
Communications › Public Address System › Loudspeaker
Issued 10 May 2018 Resolved
Engine control room speaker missing horn and electrical wires exposed.
Action required: 705 - Other - as specified
Due 9 June 2018
Resolved 9 July 2018
Resolution: Speaker replaced 5/10/2018
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 10 May 2018 Resolved
STBD fwd outboard sprinker clogged.
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 10 May 2018
Resolution: Removed head and clean out rust. advised NCDOT to use clean out to flush system.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2018 Resolved
Ammonia packets expired. The box had one date of 02/2017 and a sticker was palced over it with a dat of 2022.
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 10 May 2018
Resolution: Provided new ammonia packets.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 14 December 2017 Resolved
#1 air receiver had corrosion and was need of clean out for further inspection this date. Company to provide documentation of U1A for max allowable corrosion limits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2018
Resolved 9 May 2019
Construction/Loadline › Structures › Door
Issued 14 December 2017 Resolved
Make repairs to self closing door to galley and passenger lounge.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2018
Resolved 24 January 2018
Resolution: M/I verified new self closing devices were installed and tested this date satisfactory.
Electrical › Lighting (emergency) › Switch
Issued 14 December 2017 Resolved
The emergency lighting at #3 life raft embarkation station was tripping the breaker.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2018
Resolved 24 January 2018
Resolution: Maintenance trouble shot and replaced the breaker. Attending M/I tested and found light in satisfactory operation post replacement.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 December 2017 Resolved
Bow Thruster rooom emergency light was found inoperative this date.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 24 January 2018
Resolution: Maintenance replaced bulb and verified by the attending inspector.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 14 December 2017 Resolved
Missing lagging on the exhuast of the bow thruster.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 24 January 2018
Resolution: New lagging was installed and verified by the attending M/I.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 14 December 2017 Resolved
The rescue boat motor stalled out and was not operating properly, during man overboard drill this date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2018
Resolved 24 January 2018
Resolution: Maintenace replaced rescue boat motor and was verified properly working by the attending M/I.
Construction/Loadline › Penetrations › Gasket
Issued 14 December 2017 Resolved
A/C line is ran through fire tight bhd.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 9 May 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 14 December 2017 Resolved
CO2 nozzle has a hole due to wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 9 May 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 14 December 2017 Resolved
Stbd reduction gear filter was leaking during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 9 May 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 14 December 2017 Resolved
The guard for the audible siren (alarm) was not connected properly and missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 24 January 2018
Resolution: Maintenance properly reinstalled the hardware, so siren is properly working as designed.
Construction/Loadline › Penetrations › Weld
Issued 14 December 2017 Resolved
The port engine room intake plenum is wasted and corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 16 February 2018
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 20 November 2017 Resolved
Vessel main sea chest has pin hole leak (located just aft of main sea chest valve). In addition, vessels MSD piping also has small leak.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2017
Resolved 7 December 2017
Resolution: Witnessed hydro and installation of new piping.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 20 November 2017 Resolved
Vessel has vibration in area of the port reduction gear.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2017
Resolved 7 December 2017
Resolution: Found loose fit to taper on port propeller. Witnessed blue-fit and installation of new propeller.
Construction/Loadline › Hull › Side Shell
Issued 5 April 2016 Resolved
Effect repairs IWO port main deck superstructure & associated framing between frames 38-42.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 7 October 2016
Resolution: Damage repaired during ddx.
Engineering › Thrusters › Seal
Issued 18 June 2012 Resolved
Repair shaft seal on bow thruster and demonstrate proper operation.
Due 23 July 2012
Resolved 25 July 2012
Resolution: Vessel was brought to NCDOT Shipyard for repairs.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 August 2011 Resolved
Install suitable emergency lighting IWO means of escape from bow thruster room and aux machinery space. The forward most flush deck scuttles need proper illumination.
Action required: 705 - Other - as specified
Due 22 September 2011
Resolved 27 March 2012
Resolution: Installed.
Electrical › Electric Supply System (service) › Battery Charger
Issued 9 February 2010 Resolved
Provide drip-proof covers IWO emergency generator, general alarm and bow thruster battery chargers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 9 February 2010
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 February 2010 Resolved
Provide drip-proof outlet IWO STBD engine room (just FWD of #1 Gen). The installed outlet is exposed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 6 April 2010
Engineering › Fuel Oil Service System › Filter
Issued 16 December 2008 Resolved
Install plugs vice petcocks in all "Racor Fuel Filters."
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 December 2008
Resolved 17 December 2008
Resolution: Plugs installed.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 16 December 2008 Resolved
Install "Cap" on Lube Oil tank drain pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 December 2008
Resolved 17 December 2008
Resolution: Plug installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 11 September 2008 Resolved
Secure snack machine 01 deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2008
Resolved 11 September 2008
Resolution: Snack machine was bolted to the wall using an L bracket.
Communications › Alarms/Indicators › General Alarm
Issued 11 September 2008 Resolved
Adjust general alarm main deck, fwd.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2008
Resolved 11 September 2008
Resolution: Alarm was switched with an alarm from the 02 passenger lounge. Both alarms are audible.
Fire Fighting › Means of Escape › Blocked
Issued 11 September 2008 Resolved
Maintain all escape routes clear of cars or other obstructions while underway or moored.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2008
Resolved 11 September 2008
Resolution: Vessel rep. stated vehicles will no longer be parked above escape hatches. Permanent fix (painting) to follow.
Stability › Incline Test › General
Issued 23 March 2007 Resolved
Provide updated stability letter, stability booklet or lightship change determination including changes to hydrostatics prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2007
Resolved 12 June 2009
Resolution: Issued by MSC.
Engineering › Steering Gear System › Valve
Issued 23 March 2007 Resolved
Provide accurate steering gear block diagram depicting proper valve alignment for all modes of operation.
Action required: 705 - Other - as specified
Due 3 October 2007
Resolved 9 June 2009
Resolution: Provided.
Deck/Cargo › Ballast › Tank
Issued 23 October 2006 Resolved
Provide PE certified plans for ballast tanks and pumps in accordance with Coast Guard and an approved Classification Society rules. These tanks should be installed in the ballast voids and designed to ensure that when the ballast tanks are full, the vessel can maintain a proper stability and trim when in the light ship condition. Pumps and piping systems will be designed to rapidly move the balla
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 12 September 2007
Resolution: Vessel was modified in an attempt to correct vibration issues.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 September 2006 Resolved
Vee and Weld fracture in bulkhead between number 5 void and stbd ballast tank in way of frame 115 and a pinhole leak for a repaired crank in way of frame 114 in same bulkhead.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 September 2006
Resolved 7 September 2006
Resolution: Correctred testing witnessed Sherman Goodwin Lic Master
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 September 2006 Resolved
Repair/renew missing dog from escape scuttle in aux machinery space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2006
Resolved 6 September 2006
Resolution: Corrected
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 6 September 2006 Resolved
Properly secure NAB machine in passenger space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2006
Resolved 12 September 2006
Engineering › Fuel Oil Service System › Flange
Issued 6 September 2006 Resolved
Repair/renew leaking fuel oil fitting on Stbd Gen Racor Filters
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2006
Resolved 12 September 2006
Fire Fighting › Fire Main › Condition
Issued 6 September 2006 Resolved
Repair/renew leaking fire main piping in way of swing check in aft bulkhead of engine room on port side
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2006
Resolved 12 September 2006
Fire Fighting › Fire Hoses
Issued 17 May 2004 Resolved
Provide 2 servicable 50' length fire hoses to replace the 2 fire hoses that burst. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2004
Resolved 17 May 2004
Resolution: Fire hoses provided prior to conclusion of COI inspection to the staisfaction of attending Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 22 April 2004 Resolved
Cut and replace approximately a 56" X 28" section of the bulkhead in the Bow Thruster compartment in the vicinity of the ladder on Frame 10, approximately 1ft starboard of center line and 4' 10" from baseline with 5/16" steel. Due to excessive 'pitting'.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2004
Resolved 3 May 2004
Resolution: Section of bulkhead cut out and replaced to the satisfaction of Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 22 April 2004 Resolved
Cut section of plating approximately 51" wide port side 12 feet from centerline crossing frames 104 and 105. Cut section of plating approximately 48" X 51" below the chine 8 feet off of center line also crossing frames 104 and 105. Replace with 3/8" steel due to excessive pitting.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 May 2004
Resolved 3 May 2004
Resolution: Sections of plating replaced to the satisfaction of Marine Inspector.
Construction/Loadline › Hull
Issued 9 October 2002 Resolved
Hull plating contained one small stress fracture on stbd side, between frames 83 and 84, 24 inches from the chine, near the stern. Crop and renew shell plating with suitable plating for outer bottom shell. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2002
Resolution: NC DOT Shipyard inserted a 12 inch by 35 inch hull plate to repair damaged area.
Construction/Loadline › Hull
Issued 9 October 2002 Resolved
Hull plating contained one small stress fracture on port side, between frames 81 and 83, 48 inches from the chine, near the stern. Crop and renew shell plating with suitable plating for outer bottom shell. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2002
Resolution: NC DOT Shipyard inserted a 12 inch by 35 inch hull plate to repair damaged area.
Engineering › Fuel Oil Service System
Issued 23 April 2002 Resolved
Starboard side Fuel Oil fill remote valve operating mechanism must be replaced and prove operational to the attending Marine Inspector. LEGACY COMPONENT DESC: Valve, Control
Due 29 May 2002
Resolved 10 May 2002
Resolution: Valve was reworked and inspected fo proper operation.
Communications › Internal Communications System
Issued 23 April 2002 Resolved
Two public address speaker need to be added to the vessel. One speaker by the top of the ladders in the forward section of the passenger (O1) deck and the other aft of the super structure below the aft control station.
Due 29 May 2002
Resolved 10 May 2002
Resolution: New speakers were installed and tested.
Lifesaving › Lifejacket/PFD (General)
Issued 23 April 2002 Resolved
Twelve PFD's must be added to the vessel's compliment prior to carry passengers. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2002
Resolved 10 May 2002
Resolution: The additional PFDs were added to the vessel''s compliment.
Operations/Management › Drills/Instruction
Issued 23 April 2002 Resolved
Crew proficiency drills must be conducted to the satifaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Fire/Abandon Ship
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2002
Resolved 10 May 2002
Resolution: Drills conducted
Fire Fighting
Issued 10 April 2001 Resolved
PROVIDE APPROVED PLANS FOR INSTALLED CO2 SYSTEM IN WAY OF EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 11 May 2001
Resolved 20 April 2001
Engineering
Issued 10 April 2001 Resolved
PROVE BOW THRUSTER IN WAY OF AFT STATION CONTROL PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Construction/Loadline
Issued 10 April 2001 Resolved
MAKE ADJUSTMENTS AS NEEDED AND PROVE WATERTIGHT DOOR #5
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Lifesaving
Issued 10 April 2001 Resolved
RENEW RESCUE BOAT FALLS TO PROVIDE ADEQUATE LENGTH FOR LAUNCHING IN AN UNFAVORABLE LIST CONDITION.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Electrical
Issued 10 April 2001 Resolved
LOCATE AND REMOVE HARD GROUND IN WAY OF AUXILIARY MACHINERY SPACE EXHAUST FAN CIRCUIT.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Electrical
Issued 10 April 2001 Resolved
PROVE OPENING AND CLOSURE OF EMERGENCY GENERATOR ROOM VENTILATION LOUEVERS WITH STARTING AND STOPPAGE OF E-GEN SET AND CO2 SYSTEM RELEASE.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Engineering
Issued 10 April 2001 Resolved
ADDRESS AND PROVIDE REVISED TEST PROCEDURES AS REQUIRED IN G-MSC LETTER, SERIAL # E2-0100058, DTD 08JAN01.
Condition: Unknown
Due 13 August 2001
Resolved 13 August 2001
Engineering
Issued 10 April 2001 Resolved
COMPLETE AND PROVIDE COPY OF MARINE ENGINE CONTROLS, INC. FEMA TEST FOR ALLTHROTTLE CONTROLS.
Condition: Unknown
Due 11 May 2001
Resolved 20 April 2001
Engineering
Issued 26 May 2000 Resolved
PROVIDE REMOTE SHUTDOWNS FOR MAIN PROPULSION ENGINES IN WAY OF FORWARD AND AFT PILOTHOUSE.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Engineering
Issued 26 May 2000 Resolved
PROVIDE FIXED PIPING AS REQUIRED TO INSTALLED FLEXIBLE CONNECTION (THREE) IN WAY OF KEEL COOLER PIPING.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Lifesaving
Issued 19 December 1997 Resolved
PROVIDE 12 ADDITIONAL TYPE I ADULT PFDS. PERSONS ON BOARD LIMITED TO 294 UNTIL PROVIDED.
Condition: Unknown
Due 19 January 1998
Resolved 2 January 1998
Fire Fighting
Issued 19 December 1997 Resolved
RECHARGE OR REPLACE 35LB CO2 FOR EMERENCY GENERATORSPACE. TWO BII ARE TO BEPROVIDED OUTSIDE OF SPACE UNTIL PROVIDED. SPACE IS TO BE MANNED AT ALL TIMES WHEN EMERENCY GENERATOR IS OPERATING.
Condition: Unknown
Due 21 December 1997
Resolved 22 December 1997
Engineering
Issued 21 November 1997 Resolved
MADE REPAIRS TO LOGIC MASTER SYSTEM FOR MAIN ENGINE CONTROL. VESSEL IS NOT TO OPERATE UNTIL REPAIRS COMPLETED AND INSPECTED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 21 November 1997
Resolved 26 November 1997
Electrical
Issued 2 October 1997 Resolved
MAKE REPAIRS TO EMERGENCY GENERATOR. VESSEL IS NOT TO OPERATE UNTIL REPAIRSCOMPLETED AND WITRESS BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 3 October 1997
Resolved 3 October 1997
Navigation
Issued 23 August 1997 Resolved
The stbd steering system solenoid and bridge circuit card replaced due to malfunction.
Condition: Unknown
Due 23 August 1997
Resolved 16 September 1997
Engineering
Issued 18 August 1997 Resolved
REMOVE VALVE FROM BOTH AIR RECEIVER RELIEF VALVE LINE. NO VALVES OR_x001C_ STOPPING DEVICES ARE TO BE INSTALLED IN RELIEF VALVE LINE.
Condition: Unknown
Due 18 August 1997
Resolved 22 August 1997
Engineering
Issued 18 August 1997 Resolved
PROVIDE FLAME SHIELD FOR RACOR FUEL FILTER ON BOW THUSTER.
Condition: Unknown
Due 31 August 1997
Resolved 22 August 1997
Engineering
Issued 18 August 1997 Resolved
PROVIDE OPERATIONAL TEST OF BOW THUSTER.
Condition: Unknown
Due 21 August 1997
Resolved 22 August 1997
Construction/Loadline
Issued 8 July 1997 Resolved
Make permanent repairs to 2" crack in side shell plating, frame 42, port side appox 18" from deck.
Condition: Unknown
Due 10 July 1997
Resolved 11 July 1997
Navigation
Issued 23 January 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, MAKE REPAIRS TO PORT RUDDER WHERE BENT AND DEMONSTRATE PROPER OPERATION OF STEERING SYSTEM TO THE SATISFACTION OF AN ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 2 January 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPLACE AND PROVE PROPER OPERATION OF PNEUMATIC CYLINDER CONTROL HEAD (LINKED TO HEAT SENSOR) IN WAY OF FIXED CO2SYSTEM LOCATED IN BOW THRUSTER ROOM.
Condition: Unknown
Due 14 January 1997
Resolved 2 January 1997
Documentation
Issued 2 April 1996 Resolved
PROVIDE LIFERAFT CAPACITY PLACARD CORRESPONDING TO LIFERAFT ONBOARD.
Condition: Unknown
Due 16 April 1996
Resolved 20 June 1996
Electrical
Issued 5 January 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, DEMONSTRATE PROPER OPERATION OF LOW LUBE OIL PRESSURE SHUT DOWN ON NUMBER ONE (1) GENERATOR.
Condition: Unknown
Due 5 January 1996
Resolved 16 January 1996
Lifesaving
Issued 5 January 1996 Resolved
PROVIDE AN ADDITIONAL (10) CHILD AND (8) ADULT TYPE I PFD'S.
Condition: Unknown
Due 5 January 1996
Resolved 16 January 1996
Accommodation/Occupational Safety
Issued 5 January 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPLACE FAULTY RELIEF VALVE ON NUMBER (1) AIR RECEIVER.
Condition: Unknown
Due 5 January 1996
Resolved 16 January 1996
Electrical
Issued 5 January 1995 Resolved
PROVIDE COVERS FOR (2) ELECTRICAL JUNCTION BOXES ON EMERGENCY GENERATOR.
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Lifesaving
Issued 5 January 1995 Resolved
MARK FORWARD LIFERAFT STATION IAW 46CFR78.47-63
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Electrical
Issued 5 January 1995 Resolved
PROVE OPERATION OF EMERGENCY GENERATORS HIGH TEMPERATURE ALARM IAW 46CFR112.50-1(I)
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Electrical
Issued 5 January 1995 Resolved
PROVE OPERATION OF EMERGENCY MGENERATOR LUBE OIL SHUTDOWN IAW 46CFR112.50- 1(H)
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Lifesaving
Issued 5 January 1995 Resolved
PROVIDE 41 ADULT PFD'S. VESSEL RESTRICTED TO 259 TOTAL PERSONS UNTIL THIS ITEM IS CLEARED. AS PER 46 CFR 75.40-10
Condition: Unknown
Due 5 January 1995
Resolved 5 January 1995
Navigation
Issued 29 June 1994 Resolved
REPAIR LEAKING HYDRAULIC SUPPLY VALVES IN STEERING COMPARTMENT.
Condition: Unknown
Due 29 June 1994
Resolved 29 June 1994
Engineering
Issued 5 April 1994 Resolved
MAKE #2, #3 AIR RECEIVERS AVAILABLE FOR INTERNAL EXAM.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Electrical
Issued 5 April 1994 Resolved
MAKE OPERABLE CONTROLLER INTERLOCKS FOR #1 AND #2 STEERING CONTROLLERS.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Accommodation/Occupational Safety
Issued 26 January 1994 Resolved
PROVIDE EMERGENCY LIGHTING FOR THE BOW THRUSTER ENGINE ROOM, VOID #3, AND MSD SPACE. SUBMIT ONE LINE DIAGRAM OF ELECTRICAL WIRING TO EMERGENCY BOARD.
Condition: Unknown
Due 26 January 1994
Resolved 26 January 1994
Construction/Loadline
Issued 25 June 1993 Resolved
MAKE PERMENANT REPAIRS TO THE PORT SIDE BOTTOM PLATING IN WAY OF FRAMES 70 AND 71 APPROXIMATELY ONE FOOT FROM THE CENTERLINE.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Fire Fighting
Issued 15 December 1992 Resolved
REPAIR LEAKING SHAFTS AT BOTH FIRE PUMPS.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Navigation
Issued 15 December 1992 Resolved
STOP STEERING FLUID FILTER LEAKS.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Navigation
Issued 15 December 1992 Resolved
REPAIR ENGINE ROOM CONTROL BOOTH SOUND POWERED TELEPHONE BELL AND VISUAL ALARM.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Electrical
Issued 15 December 1992 Resolved
REPAIR OVERSPEED TRIPS ON #1 MAIN GENERATOR AND EMERGENCY GENERATOR.
Condition: Unknown
Due 15 December 1992
Resolved 15 December 1992
Engineering
Issued 14 October 1992 Resolved
MAKE OPERABLE THE LOW LUBE OIL ALARM FOR #2 GENERATOR.
Condition: Unknown
Due 14 October 1992
Resolved 14 October 1992
Fire Fighting
Issued 14 October 1992 Resolved
PROVIDE TAMPER PROOF SEALS FOR ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 October 1992
Resolved 14 October 1992
Navigation
Issued 14 October 1992 Resolved
CORRECT THE FIRE HAZARD ON THE LEAKING HYDRAULIC FILTER INSTALLED ON BOTH STEERING PUMPS.
Condition: Unknown
Due 14 October 1992
Resolved 14 October 1992
Electrical
Issued 5 November 1991 Resolved
MAKE OPERABLE EMERGENCY LIGHTS IN THE FWD PASSENGER CABIN AND PILOT HOUSE.
Condition: Unknown
Due 5 November 1991
Resolved 5 November 1991
Navigation
Issued 5 November 1991 Resolved
MAKE OPERABLE NAVIGATION LIGHT INDICATOR PANEL
Condition: Unknown
Due 5 November 1991
Resolved 5 November 1991
Lifesaving
Issued 20 September 1991 Resolved
PROVIDE 21 ADULT PFD'S, TOTAL PERSONS ALLOWED LIMITED TO 279 UNTIL COMPLETE
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Lifesaving
Issued 20 September 1991 Resolved
PROVIDE SEPARATE STOWAGE FOR CHILDRENS PFD'S._x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Engineering
Issued 20 September 1991 Resolved
INSTALL PROPER FLAME SCREENS ON FUEL TANK VENTS._x001C_
Condition: Unknown
Due 20 September 1991
Resolved 20 September 1991
Construction/Loadline
Issued 7 May 1991 Resolved
REPAIR AS ORIGINAL, CRACKED SIDE SHELL PLATE IN WAY OF PORT MDE EXHAUST.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Construction/Loadline
Issued 7 May 1991 Resolved
PROVIDE GAUGING OF SIDE SHELL PLATE IN WAY OF PORT EXHUAST PIPE AND OF STARBOARD SIDE SHELL IN WAY OF EXHAUST IN PRESENTS OF A CG INSPECTOR AND RENEW PLATE AS NEEDED.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Electrical
Issued 7 May 1991 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR LOW LUE OIL SHUT DOWN.
Condition: Unknown
Due 7 May 1991
Resolved 7 May 1991
Electrical
Issued 6 November 1990 Resolved
MAKE OPERATIONAL GENERAL ALARM BELL IN THE PASSNEGER COMPT STBD SIDE.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Navigation
Issued 6 November 1990 Resolved
EXCESSIVE LEAKAGE AT PACKING GLAND AND WORN PACKING GLAND COLLAR PORT AND STBD RUDDER TO BE REPAIRED.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Navigation
Issued 6 November 1990 Resolved
MAKE OPERATIONAL THE SOUND POWERED PHONE BELL ON THE PORT BOW.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Fire Fighting
Issued 15 May 1990 Resolved
CORRECT FIXED CO2 SYSTEM TIME DELAYS IN THE BOW THRUSTER ROOM AND ENGINE ROOM TO OPERATE AT A MINIMUM OF 25 SECONDS AS STAMPED.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Fire Fighting
Issued 15 May 1990 Resolved
REPLACE NOZZEL ON FIRE STATION #2 WITH APPROVED NOZZEL WITH CORRECT THREADSTO MATCH INSTALLED FIRE HOSE.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Lifesaving
Issued 15 May 1990 Resolved
PROVIDE AN ADDITIONAL 16 CG APPROVED ADULT PFD,S TO EQUAL A TOTAL OF 300 ONBOARD.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Fire Fighting
Issued 15 May 1990 Resolved
PROVIDE PROPERLY SERVICED B-II TYPE PORTABLE FIRE EXTINGUISHER TO REPLACE UNIT ON STATION # 7.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Navigation
Issued 15 May 1990 Resolved
REPLACE MISSING STARBOARD RUDDEER AND CONDUCT SATISFACTORY OPERATIONAL TEST PRIOR TO CARRING PASSENGERS.
Condition: Unknown
Due 15 May 1990
Resolved 15 May 1990
Fire Fighting
Issued 11 July 1989 Resolved
REPLACE CO2 HOSE IN ENGINE ROOM WITH A HOSE MEETING THE SYSTEM MANUFACTURER'S SPECIFICATIONS.
Condition: Unknown
Due 11 July 1989
Resolved 11 July 1989
Navigation
Issued 12 June 1989 Resolved
CORRECT ENGINE ORDER TELEGRAPH IN THE AFT CONTROL STATION TO PROPERLY OPERATE.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Fire Fighting
Issued 12 June 1989 Resolved
REPLACE WORN HOSE ON ENGINE ROOM CO2 HOSE REEL SYSTEM.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Navigation
Issued 12 June 1989 Resolved
MAKE OPERATIONAL THE AUDIBLE ALARM FOR THE NAVIGATION LIGHT PANEL.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Engineering
Issued 12 June 1989 Resolved
OPEN AND MAKE AVAILABLE FOR INTERNAL INSPECTION ALL (4) FOUR S/S AIR RECEIVERS.
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Fire Fighting
Issued 8 November 1988 Resolved
REPLACE ALL FIREHOSE THAT HAS ALUMINUM COUPLINGS WITH APPROVED FIRE HOSE MEETING UL STANDARD 19, WITH BRASS COUPLINGS.
Condition: Unknown
Due 8 November 1988
Resolved 8 November 1988
Lifesaving
Issued 8 November 1988 Resolved
RENEW THE RING BUOY PORT SIDE BOW.
Condition: Unknown
Due 8 November 1988
Resolved 8 November 1988
Fire Fighting
Issued 21 June 1988 Resolved
REWEIGH ALL CO2 CYLINDERS IN FIXED CO2 SYSTEMS AND SUBMIT A COPY OF REPORT TO THE USCG.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Lifesaving
Issued 21 June 1988 Resolved
14 ATLANTIC PACIFIC MODEL 5 PFD DISCOVERED WITH ROTTED STRAPS, IMMEDIATELY REPLACED.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Electrical
Issued 21 June 1988 Resolved
PROVIDE BLANK FOR OPENING IN LIGHT & POWER PANEL #2.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Electrical
Issued 21 June 1988 Resolved
REPAIR AUTOMATIC BUS TRANSFER FOR EMERGENCY GENERATOR AND DEMONSTRATE EMERGENCY SYSTEMS.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Construction/Loadline
Issued 21 June 1988 Resolved
INSTALL WATERTIGHT DOOR WITH A QUICK ACTION CLOSING DEVICE OPERATIVE FROM BOTH SIDES OF THE DOOR IN THE LOWER BOW THRUSTER ROOM PER 46CFR170.270(A).
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Construction/Loadline
Issued 21 June 1988 Resolved
INSTALL INDICATOR ALARM LIGHT ON BRIDGE FOR MSD SPACE WATERTIGHT DOOR PER 46CFR170.270(D).
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Lifesaving
Issued 21 June 1988 Resolved
17 ATLANTIC PACIFIC MODEL 3 ADULT PFD DISCOVERED WITH ROTTED STRAPS, IMMEDIATELY REPLACED.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Construction/Loadline
Issued 21 June 1988 Resolved
PROVIDE DOGGING PIPE TO WATERTIGHT DOOR FOR BOW THRUSTER ROOM.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Accommodation/Occupational Safety
Issued 21 June 1988 Resolved
PAD AND/OR MARK AS A HAZARD THE DECK BEAM AT HEAD HEIGHT AT LADDER TO BOW THRUSTER SPACE.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Electrical
Issued 21 June 1988 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF OVERSPEEDS FOR GENERATORS.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Unknown
Issued 21 June 1988 Resolved
PROVIDE MARKINGS FOR VALVES IN ENGINE ROOM, ESPECIALLY UNDER DECK PLATES, AS NEEDED.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Navigation
Issued 21 June 1988 Resolved
ADJUST/RENEW PACKING FOR RUDDER CARRIERS.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Electrical
Issued 21 June 1988 Resolved
SUBMIT PLANS TO COGNIZANT OCMI FOR ELECTRIC BILGE PUMPS IN SHAFT ALLEY.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Unknown
Issued 21 June 1988 Resolved
MOUNT AND PROVIDE IDENTIFICATION MARKING SIGN FOR GENERAL ALARM IN ENGINE ROOM CONTROL ROOM.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Lifesaving
Issued 21 June 1988 Resolved
REMARK SIGNS FOR BOTH 15 PERSON INFLATABLE RAFTS.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Electrical
Issued 2 November 1987 Resolved
DEMONSTRATE PROPER OPERATION OF SHIPS SERVICE GENERATOR OVERSPEED SHUTDOWNS
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Fire Fighting
Issued 2 November 1987 Resolved
LABEL VALVES FOR FIRE FIGHTING AND BILGE SYSTEM.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Engineering
Issued 2 November 1987 Resolved
DEMONSTRATE OPERATION OF MAIN ENGINES.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Fire Fighting
Issued 2 November 1987 Resolved
DEMONSTRATE OPERATION OF FIREMAIN SYSTEM INCLUDING PUMPS,HYDRANTS, AND HOSES.
Condition: Unknown
Due 2 November 1987
Resolved 2 November 1987
Engineering
Issued 1 April 1986 Resolved
CALIBRATE PRESSURE GAUGES ON AIR RECEIVERS AND ADJUST SAFETY VALVES FOR 190 PSI LIFT.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Electrical
Issued 16 July 1985 Resolved
REPLACE BROKEN GLASS IN SHORE POWER VOLTMETER.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Navigation
Issued 16 July 1985 Resolved
MAKE STEERING MOTOR POWER FAILURE ALARMS OPERABLE.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Engineering
Issued 16 July 1985 Resolved
REPAIR OR REPLACE TWO (2) RELIEF VALVES ON AIR RECEIVERS TO RESTORE HAND RELIEF OPERATION.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Electrical
Issued 5 April 1985 Resolved
DEMONSTRATE PROPER OPERATION OF AUTOMATIC BUS TRANSFER ON EMERGENCY GENERATOR.
Condition: Unknown
Due 5 April 1985
Resolved 5 April 1985
Fire Fighting
Issued 5 April 1985 Resolved
POST WARNING: "WHEN ALARM SOUNDS-VACATE AT ONCE-CARBON DIOXIDE BEING RELEASED" IN ENGINEROOM IN PLAIN SIGHT.
Condition: Unknown
Due 5 April 1985
Resolved 5 April 1985
Construction/Loadline
Issued 19 October 1984 Resolved
DRYDOCK VESSEL FOR THE PURPOSE OF MAKING PERMANENT REPAIRS TO THE BOTTOM SHELL PLATE IN WAY OF SOUNDING TUBE OF #5 VOID SPACE.
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984
Construction/Loadline
Issued 19 October 1984 Resolved
DRYDOCK VESSEL FOR THE PURPOSE OF MAKING PERMANENT REPAIRS TO THE BOTTOM SHELL PLATE IN WAY OF SOUNDING TUBE OF #5 VOID SPACE.
Condition: Unknown
Due 19 October 1984
Resolved 19 October 1984

Casualty record · 39

10 December 2002Significant Marine Casualty · role: Involved in a Marine Casualty · activity 1717165
14 December 2003Routine · role: Involved in a Marine Casualty · activity 1999521
31 March 2004Routine · role: Involved in a Marine Casualty · activity 2225274
1 April 2006Routine · role: Involved in a Marine Casualty · activity 2619332
1 May 2006Routine · role: Involved in a Marine Casualty · activity 2638581
4 May 2006Routine · role: Involved in a Marine Casualty · activity 2641653
6 May 2006Routine · role: Involved in a Marine Casualty · activity 2644014
11 November 2006Routine · role: Involved in a Marine Casualty · activity 2826053
13 November 2006Routine · role: Involved in a Marine Casualty · activity 2823777
7 January 2007Routine · role: Involved in a Marine Casualty · activity 2910030
27 October 2008Routine · role: Involved in a Marine Casualty · activity 3352349
17 December 2008Routine · role: Involved in a Marine Casualty · activity 3381823
11 January 2009Routine · role: Involved in a Marine Casualty · activity 3393331
14 June 2009Routine · role: Involved in a Marine Casualty · activity 3504793
12 December 2009Routine · role: Involved in a Marine Casualty · activity 3649712
24 January 2010Routine · role: Involved in a Marine Casualty · activity 3669257
19 June 2010Routine · role: Involved in a Marine Casualty · activity 3772265
7 June 2011Routine · role: Involved in a Marine Casualty · activity 4038059
28 June 2011Routine · role: Involved in a Marine Casualty · activity 4061361
15 July 2011Routine · role: Involved in a Marine Casualty · activity 4082175
5 May 2012Routine · role: Involved in a Marine Casualty · activity 4303335
20 August 2012Routine · role: Involved in a Marine Casualty · activity 4432662
25 November 2012Routine · role: Involved in a Marine Casualty · activity 4495684
8 October 2013Routine · role: Involved in a Marine Casualty · activity 4734949
14 March 2015Routine · role: Involved in a Marine Casualty · activity 5086624
22 February 2016Routine · role: Involved in a Marine Casualty · activity 5843452
13 February 2017Routine · role: Involved in a Marine Casualty · activity 6102743
31 December 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6367816
9 July 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6488422
13 June 2019Routine · role: Involved in a Marine Casualty · activity 6721327
2 September 2020Routine · role: Involved in a Marine Casualty · activity 7055357
31 October 2020Routine · role: Involved in a Marine Casualty · activity 7101499
8 January 2021Routine · role: Involved in a Marine Casualty · activity 7121539
4 February 2021Routine · role: Involved in a Marine Casualty · activity 7148869
4 July 2022Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7507501
30 November 2024Routine · role: Involved in a Marine Investigation (non-casualty) · activity 8056731
6 March 2025Routine · role: Involved in a Marine Casualty · activity 8104057
9 July 2025Routine · role: Involved in a Marine Casualty · activity 8280108
3 July 2026Routine · role: Involved in a Marine Casualty · activity 8431377
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.