MAURY USCG vessel records
← All vessels

CIFC-2

Built
1965
Last inspected
9 March 1997
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 9 March 1997
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (1985–1997)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-45116

Documentation record

Tonnage as PSIX records it9815 - Regulatory (Subpart C or D), Gross Ton
9815 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ST. CHARLES Towing Vessel · MISLE 63855 · 9 March 1997 · activity 127986NED FERRY Towing Vessel · MISLE 76011 · 9 March 1997 · activity 127986ASCENSION Towing Vessel · MISLE 56658 · 27 December 1996 · activity 168383ST CHARLES Freight Barge · MISLE 91415 · 27 December 1996 · activity 168383

Inspection history · 24

9 March 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 127986
27 December 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 168383
2 August 1993 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1154207
1 July 1993 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1373881
16 February 1993 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 840124
4 May 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 948613
14 April 1992 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1267589
6 December 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 946183
1 April 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1218393
15 March 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 996831
4 March 1991 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1220200
24 July 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1218479
20 June 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352097
23 May 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1204346
6 April 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347239
24 June 1988 Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 897185
22 June 1987 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1011818
21 November 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1019486
7 August 1986 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1000686
14 July 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1003095
27 January 1986 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 997465
3 December 1985 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1301147
9 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287626
2 July 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289081

Deficiency record · 18

Fire Fighting
Issued 16 February 1993 Resolved
Provide documentation of inspection and inspect the 2 B-II extinguishers inmachinery space.
Condition: Unknown
Due 3 March 1993
Resolved 3 March 1993
Engineering
Issued 14 April 1992 Resolved
Provide USCG approved fuel hose for diesel electric generator.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Engineering
Issued 14 April 1992 Resolved
Install racor drip shields on fuel filter for anchor windlass diesel engine.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Deck/Cargo
Issued 14 April 1992 Resolved
Clean oil under diesel engine.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Construction/Loadline
Issued 14 April 1992 Resolved
Paint in loadline
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Construction/Loadline
Issued 14 April 1992 Resolved
Paint in draft marks.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Construction/Loadline
Issued 4 March 1991 Resolved
PROVE PROPER OPERATION OF THE VESSELS'S BALLAST SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Construction/Loadline
Issued 6 April 1989 Resolved
REPAIR FRACTURES #3 CARGO HATCH COAMING.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Accommodation/Occupational Safety
Issued 6 April 1989 Resolved
REPAIR DAMAGED STEPS TO MACHINERY SPACES.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Deck/Cargo
Issued 6 April 1989 Resolved
REMOVE DECK CARGO PRIOR TO SAILING.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Electrical
Issued 6 April 1989 Resolved
INSTALL WOOD CHOCKS IN ALL BATTERY BOXES.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Engineering
Issued 6 April 1989 Resolved
RENEW CRACKED VENT HOUSING ON FWD FUEL TANK.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Electrical
Issued 6 April 1989 Resolved
INSTALL GUARD ON GENERATOR BELT DRIVE.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Construction/Loadline
Issued 6 April 1989 Resolved
INSTALL GUARD ON BALLAST PUMP DIESEL AFT BELT DRIVE.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Engineering
Issued 6 April 1989 Resolved
INSTALL APPROVED HEAT SHIELD ON GENERATOR FUEL FILTER.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Deck/Cargo
Issued 6 April 1989 Resolved
REPLACE FLAME SCREEN GANTRY DIESEL FUEL TANK.
Condition: Unknown
Due 6 April 1989
Resolved 6 April 1989
Deck/Cargo
Issued 7 August 1986 Resolved
REMOVE 5 GAL. CAN OF PAINT AND OTHER FLAMIABLE MATERIAL AND CLEAN MACH. SPACES.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Deck/Cargo
Issued 7 August 1986 Resolved
PROVE OPERATION OF RELIEF VALVE ON AIR RECEIVER PRIOR TO USING
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986