MAURY USCG vessel records
← All vessels

EMPRESS

Built
1966
Last inspected
7 July 2026
Controls
None recorded without a removal date
Also recorded as
GATEWAY PARTY LINER (2005–2007)

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 7 July 2026
…with no type recorded42
Operational controls None recorded without a removal date
Years with a record 43 calendar years (1984–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
291 - Regulatory (Subpart C or D), Gross Ton 665 - Convention (Subpart B), Gross Ton 291 - Regulatory (Subpart C or D), Net Ton 245 - Convention (Subpart B), Net Ton
Maury page id
psix-45169
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

EMPRESS II Towing Vessel · MISLE 72764 · 5 July 2021 · activity 7282434EMPRESS II Towing Vessel · MISLE 72764 · 3 May 2007 · activity 2922085EMPRESS II Towing Vessel · MISLE 72764 · 10 May 2005 · activity 2467926

Inspection history · 243

7 July 2026 MSP Additional Oversight - Risk Assessment · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8405418
28 May 2026 MSP Additional Oversight - Risk Assessment · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8378419
3 March 2026 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8319612
19 February 2026 DAPI Audit · MSP Additional Oversight - Risk Assessment · MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8312957
15 October 2025 DAPI Audit · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8234620
6 August 2025 Re-Inspection · Administrative Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8196303
15 April 2025 Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8109996
26 December 2024 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8050914
25 December 2024 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8059056
17 December 2024 MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8048039
17 September 2024 COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7997342
3 September 2024 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7995111
14 May 2024 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7908103
23 January 2024 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7848116
17 October 2023 Administrative Inspection · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7791057
20 July 2023 MTSA Verification · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7734497
2 May 2023 Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7676045
21 February 2023 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7634117
30 November 2022 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7602056
19 October 2022 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7567411
25 July 2022 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7516124
12 April 2022 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7418918
19 January 2022 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7373872
10 September 2021 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7309109
5 July 2021 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7282434
8 June 2021 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7219246
15 April 2021 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7208144
18 March 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7158836
22 October 2020 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7073955
22 July 2020 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7006263
14 January 2020 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6888968
19 September 2019 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6825641
12 August 2019 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6781405
18 April 2019 MTSA Verification · Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6665145
5 February 2019 MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6623821
5 October 2018 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6555628
17 July 2018 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6557527
1 May 2018 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6555595
27 February 2018 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6364051
11 October 2017 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6288442
15 August 2017 MTSA Verification · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6241095
17 May 2017 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6149449
23 February 2017 MTSA Verification · In-Service Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6093929
7 November 2016 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6036605
29 August 2016 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5995403
8 June 2016 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5901284
18 April 2016 Periodic Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5865439
7 April 2016 Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5968414
26 October 2015 MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5750918
13 August 2015 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5215016
16 June 2015 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5161954
2 June 2015 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5143717
8 April 2015 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5107570
25 February 2015 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5075735
6 February 2015 Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5065091
20 January 2015 Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5055752
8 January 2015 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5050532
3 December 2014 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5041967
29 October 2014 MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5014444
4 September 2014 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4974287
19 August 2014 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4960440
24 July 2014 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4933313
27 June 2014 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4908621
15 May 2014 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4860046
7 May 2014 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4852780
20 February 2014 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4802972
15 November 2013 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4753151
12 November 2013 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4734844
26 July 2013 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4665265
23 July 2013 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4662352
22 June 2013 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4633822
30 December 2012 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4509550
23 December 2012 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4507265
9 December 2012 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4504985
18 November 2012 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4488671
12 November 2012 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4484068
1 November 2012 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4476314
28 October 2012 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4475004
7 October 2012 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4459004
7 August 2012 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4402733
8 May 2012 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4305669
7 February 2012 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4239728
24 December 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4214521
8 December 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4204811
4 December 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4203818
14 November 2011 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4177237
6 November 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4194379
24 September 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4157301
11 September 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4149686
18 August 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4131793
15 August 2011 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4116086
20 June 2011 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4050837
15 November 2010 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3891825
11 August 2010 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3821081
12 May 2010 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3737896
7 May 2010 Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3734930
17 April 2010 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3736645
23 February 2010 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3684921
26 August 2009 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3577087
13 August 2009 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3581338
27 May 2009 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3487251
24 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3423067
11 December 2008 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3434197
24 November 2008 COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3368501
5 September 2008 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3318328
14 July 2008 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3267486
19 June 2008 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3241436
28 February 2008 COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3153704
28 February 2008 DAPI Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3195167
13 December 2007 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3114779
5 September 2007 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3115556
11 June 2007 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2957954
3 May 2007 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2922085
8 March 2007 COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2884095
13 February 2007 Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2871861
23 October 2006 Re-Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2806002
4 October 2006 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2793470
26 September 2006 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2787093
26 September 2006 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2787199
11 July 2006 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2716018
8 June 2006 Periodic Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2673048
28 February 2006 Hull Examination · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2593141
11 December 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2551966
8 December 2005 Re-Inspection · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2545927
13 November 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2534368
13 November 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2534433
16 October 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2547022
16 October 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2547035
8 September 2005 Periodic Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2485106
3 September 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2546971
9 June 2005 Periodic Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2384446
10 May 2005 Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2467918
10 May 2005 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2467926
29 April 2005 In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2361130
9 March 2005 MTSA Verification · COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2306487
30 November 2004 Periodic Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2249503
15 November 2004 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2241214
4 October 2004 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2225987
7 September 2004 MTSA Verification · Periodic Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2188780
9 June 2004 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2092380
2 March 2004 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2014184
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963261
9 December 2003 Quarterly Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1960307
1 October 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1937452
3 September 2003 Quarterly Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1886502
26 August 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1887393
19 August 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1992731
10 July 2003 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1841532
4 June 2003 Quarterly Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1804130
31 May 2003 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1806288
4 March 2003 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1744270
4 March 2003 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1752636
30 December 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1724310
10 December 2002 Quarterly Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1716792
22 November 2002 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1709348
10 September 2002 Quarterly Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1673720
26 June 2002 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1692460
13 June 2002 Quarterly Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1630051
5 March 2002 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1491142
4 December 2001 Quarterly Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1077047
5 September 2001 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1439254
27 July 2001 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1070230
11 June 2001 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1065160
8 June 2001 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 214662
4 June 2001 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1412302
7 March 2001 Hull Examination · COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1362012
13 December 2000 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 824695
29 September 2000 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1460465
13 July 2000 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1369762
13 June 2000 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1053266
29 March 2000 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1393385
16 December 1999 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1461227
29 September 1999 Deficiency Check · Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1457702
30 June 1999 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1464859
1 April 1999 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1438811
20 October 1998 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1466573
17 June 1998 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1433345
7 April 1998 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1449042
8 January 1998 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1438681
14 November 1997 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1121703
16 September 1997 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1411538
13 June 1997 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1383618
9 April 1997 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1447697
25 March 1997 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1104711
3 March 1997 Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1456447
29 October 1996 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1396619
29 July 1996 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 160609
17 July 1996 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1087605
19 May 1996 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 14978
18 April 1996 Hull Examination · COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1428596
16 November 1995 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 875050
18 August 1995 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1186704
2 May 1995 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1465827
17 February 1995 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1434218
1 December 1994 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1436930
6 October 1994 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 863436
18 August 1994 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 870105
1 June 1994 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1458164
18 March 1994 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1165049
17 February 1994 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1370785
22 December 1993 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1443429
30 September 1993 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1446016
29 September 1993 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1414196
25 June 1993 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1353448
23 March 1993 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1146338
10 December 1992 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1472304
8 September 1992 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1133605
9 July 1992 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1268077
7 April 1992 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1256081
10 March 1992 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1270590
19 June 1991 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 894981
5 April 1991 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1244605
11 March 1991 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 911162
21 February 1991 Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1229070
21 September 1990 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1240637
26 June 1990 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1235169
21 March 1990 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1220505
21 December 1989 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1217428
9 November 1989 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 915682
21 September 1989 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1211944
20 June 1989 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1348051
21 March 1989 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 902251
20 December 1988 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1338639
29 September 1988 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 887155
23 June 1988 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1206569
22 March 1988 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 991741
9 December 1987 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1003437
2 September 1987 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1002413
30 June 1987 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1316654
21 May 1987 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1333073
24 March 1987 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1329324
16 January 1987 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1314509
18 December 1986 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1334071
17 September 1986 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1312705
12 June 1986 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 993340
25 March 1986 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 996534
17 January 1986 Damage Survey · Credit Drydock
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1297324
7 January 1986 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 989689
20 September 1985 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 990862
12 July 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 987772
21 June 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1290741
26 March 1985 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 980096
13 December 1984 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1285415

Deficiency record · 138

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2026 Resolved
Each panelboard must have a circuit directory that has the circuit designation of each circuit. Panel "E" in the vessel's galley space was found to have two (2) circuits that were not numbered to match the circuit directory card. The vessel's crew numbered these two (2) circuits during the inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 July 2026
Resolved 7 July 2026
Resolution: Numbered during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2026 Resolved
The installation of all lifesaving appliances and arrangements must be in accordance with the requirements of subchapter W of this Chapter (46 CFR 199.211(b)). Self-igniting light attached to a lifebuoy located aft on the main deck had expired batteries. This light was replaced with a new self-igniting light with current batteries prior to the conclusion of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 February 2026
Resolved 19 February 2026
Resolution: New light was installed during the inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 August 2025 Resolved
Fire main Piping - All piping, valves, and fittings shall meet the applicable requirements of Subchapter F (Marine Engineering). Vessel's piping for the fire main system was leaking into the forwardmost void. Repair fire main system so it is leak-free.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2025
Resolved 20 August 2025
Resolution: Holed section was replaced and pressure tested.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2025 Resolved
Each outlet or junction box must have a cover. Electrical outlet in the vicinity of the life jacket storage locker on the uppermost deck was missing its cover. Replace cover on outlet.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2025
Resolved 20 August 2025
Resolution: Missing outlet cover was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 January 2024 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Electrical plug for food warmer falling out of socket, exposing male pins. Also found ground pin was broken off. Repair plug to original condition and support plug to prevent pins from being exposed.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2024
Resolved 25 January 2024
Resolution: Replaced plug with new 90 deg type. Plug properly stays in socket as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 October 2023 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Dead end wires found in machinery space. Remove wires or place dead ends in an enclosure.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 20 October 2023
Resolution: Removed all dead end wires
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 October 2023 Resolved
It shall be the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment required by the regulations in this subchapter is provided, maintained, and replaced as indicated. Monthly inspections for Fire extinguisher in machinery space not completed. Re-certify extinguisher with NFPA certified technician and complete inspections monthly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 1 December 2023
Resolution: Inspected my certified technician
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 October 2023 Resolved
Each power bilge pump must have the capacity to develop a suction velocity of not less than 400 feet per minute through the size of bilge main piping required by § 56.50–50(d)(1) of this part under ordinary conditions. Paper towels / rags found under starboard bilge pump in machinery space. Clean bilges of debris to ensure proper operation of bilge pumps in an emergency.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 20 October 2023
Resolution: Cleaned bilges
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2023 Resolved
Each lifejacket and immersion suit must be marked with the vessel's name in accordance with § 199.70 (b)(3) and (c)(3). Three life jackets found with worn name. Remark life jacket. (CORRECTED ON THE SPOT)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 November 2023
Resolved 17 October 2023
Resolution: Re-marked lifejacket as required
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2023 Resolved
Each lifejacket must be marked with Type I retro-reflective material approved under approval series 164.018. The arrangement of the retro-reflective material must meet IMO Resolution A.658(16). 17 life jackets had wasted retro-reflective material. Replace retro with new. (CORRECTED ON THE SPOT)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 October 2023
Resolved 17 October 2023
Resolution: Replaced RETRO with new
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 July 2023 Resolved
No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002 Unless specifically permitted in 400.10, flexible cables, flexible cord sets, and power supply cords shall not be used for the following: (1) As a substitute for the fixed wiring of a structure. Vessel utilizing extension cord installed behind a wall for permanently installed drink pumps. Remove extension cords and install electrical permanent fixtures or remove as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2023
Resolved 31 August 2023
Resolution: All extension cords removed. Hard wired in receptacles in space to prevent further use of permanent extension cords.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2023 Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. Grab line. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Grab line for lifebuoy wasted. Replace line with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2023
Resolved 31 August 2023
Resolution: Grab line for ring buoy replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023 Resolved
Ship's service power distribution systems design, construction, and installation, shall be in accordance with the requirements of subchapter J (Electrical Engineering) of this chapter. A receptacle outlet must not have any exposed live parts with the plug opening uncovered. Outlet on second deck in bar closet missing outlet cover. Install new outlet cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2023
Resolved 17 March 2023
Resolution: Outlet cover installed as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023 Resolved
No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002 Unless specifically permitted in 400.10, flexible cables, flexible cord sets, and power supply cords shall not be used for the following: (1) As a substitute for the fixed wiring of a structure. Vessel utilizing extension cord installed behind a wall for permanently installed drink pumps. Remove extension cords and install electrical permanent fixtures or remove as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 March 2023
Resolved 17 March 2023
Resolution: Extension cords removed and equipment hard wired in
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 October 2022 Resolved
A vessel owner or operator must ensure that the VSP consists of the individual sections listed in this paragraph (a). If the VSP does not follow the order as it appears in the list, the vessel owner or operator must ensure that the VSP contains an index identifying the location of each of the following sections: (9) Security systems and equipment maintenance. VSP did not have a section covering security systems and equipment maintenance. Add required information to VSP.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 30 November 2022
Resolution: VSP Updated with security system equipment maintenance
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2022 Resolved
All electrical engineering details and installations shall be designed and installed in accordance with subchapter J (Electrical Engineering) of this chapter. Each panelboard must meet section 17.1 of IEEE 45-2002. Distribution panels should have a degree of enclosure appropriate for the installation location. Distribution panel 2-A on second deck in bar closet has a sprung door. Repair distribution panel as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 30 November 2022
Resolution: Panel door repaired and properly closes
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2022 Resolved
A receptacle outlet must not have any exposed live parts with the plug opening uncovered. Outlet on second deck in bar closet missing outlet cover. Install new outlet cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 30 November 2022
Resolution: Outlet covers installed as required
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2022 Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. The following electrical contact hazards were found: 1) Aft bilge space j-boxes have open knockouts. Install plugs 2) Aux space inboard water pump wire cover loose. Adjust and tighten cover 3) Light fixture under on second liqueur cabinet melted. Replace or remove from service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 30 November 2022
Resolution: Electrical hazards removed
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 October 2022 Resolved
Doors, other than those which are normally locked, shall be of the self-closing type capable of closing against a 31/2 degree list, and such doors shall be numbered in accordance with § 78.47-35 of this subchapter. Port side aft door from second deck leading to third deck fails to completely close. Adjust door for full self closing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 30 November 2022
Resolution: Door adjusted and now closes properly
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 19 October 2022 Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. It is mandatory that the design, fabrication and erection of piping constructed under the regulations in this subchapter demonstrate leak tightness. Water and drains in forward void spaces leak. Repair as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 30 November 2022
Resolution: Wasted piping cropped out and replaced with new
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 October 2022 Resolved
No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002 Unless specifically permitted in 400.10, flexible cables, flexible cord sets, and power supply cords shall not be used for the following: (1) As a substitute for the fixed wiring of a structure. Vessel utilizing extension cord for permanently installed light fixtures over bars. Remove extension cords and install electrical permanent fixtures or remove as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2022
Resolved 30 November 2022
Resolution: All temp flexable cords removed as required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 January 2022 Resolved
Each child-size lifejacket and immersion suit must be appropriately marked and stowed separately from adult or extended-size devices as required in § 199.70(b)(2). Separation of adult and child sized lifejackets being stored on second deck difficult to distinguish. Re-arrange lifejackets to ensure proper separation from adult and child lifejackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 February 2022
Resolution: Moved child life jackets to a larger locker on 3rd deck so that lifejacket type can be separated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 January 2022 Resolved
Each ring buoy's body shall be finished with two coats of vinyl base paint and shall be either international orange (Color No. 12197 of Federal Standard 595) or white in color. Coating on third deck stern ring buoy is worn to base material and faded. Replace buoy with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2022
Resolution: Replaced ring buoy with new
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2022 Resolved
No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002 Unless specifically permitted in 400.10, flexible cables, flexible cord sets, and power supply cords shall not be used for the following: (1) As a substitute for the fixed wiring of a structure. Vessel utilizing extension cord for permanently installed cooler. Remove extension cord and install electrical fixture as required.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2022
Resolution: Extention cord removed and new plug hardwired in place.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2022 Resolved
Electric installations on vessels must ensure protection of passengers, crew, other persons, and the vessel from electrical hazards. Reefer electrical panel door open exposing crew to shock hazards. Secure panel as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2022
Resolution: Electrical control panel fastened closed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2021 Resolved
Markings. Each lifejacket must be marked with Type I retro-reflective material approved under approval series 164.018. The arrangement of the retro-reflective material must meet IMO Resolution A.658(16). Retro-reflective tape on multiple lifejackets wasted.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 19 October 2021
Resolution: Replaced retro-tape with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 October 2018 Resolved
Fixed electric bilge pumps not permanently wired. Permanently wire all electric bilge pumps.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2018
Resolved 14 November 2018
Resolution: Bilge Pumps wiring inspected satisfactorily
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2018 Resolved
Overhead wiring in port aft 2nd deck lifejacket locker not properly supported and dangling, causing entanglement with lifejacket deployment and distribution. Properly support electrical wiring.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2018
Resolved 14 November 2018
Resolution: Overhead wiring properly supported
Fire Fighting › Firemans Outfit › Axe
Issued 15 August 2017 Resolved
Mount Fire Axe in galley in approved bracket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 31 August 2017
Resolution: Fire axe properly mounted
Lifesaving › Lifebuoys › Stowage
Issued 15 August 2017 Resolved
Starboard Aft Ring Lifebuoy not readily deployable, remount/reposition attached line bag outside of ring lifebuoy mount
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 31 August 2017
Resolution: Line bag properly relocated to permit ready deployment of ring lifebuoy.
Lifesaving › Lifebuoys › Serviceable
Issued 7 November 2016 Resolved
Replace defective grab lines on all lifebouys
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 10 November 2016
Resolution: Replace all Lifebouys
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 June 2016 Resolved
junction box cover was missing in the port side second deck soda room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2016
Resolved 8 June 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 June 2016 Resolved
Lube /service locker slide latches to ensure ease of access.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2016
Resolved 8 June 2016
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 8 June 2016 Resolved
FCC lincence registered to the barge. Regulation requires registration to the Tug. In addition to the AIS
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 1 July 2016
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 2 June 2015 Resolved
Breather line from crankase oil pump was leaking oil. Required to replace line to prohibit leaking
Due 16 June 2015
Resolved 16 June 2015
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 2 June 2015 Resolved
Missing insulation in machinery space overhead/1st deck.
Due 16 June 2015
Resolved 16 June 2015
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 February 2015 Resolved
Provide circuit isolation device on vessel Generator distribution panel
Action required: 705 - Other - as specified
Due 25 March 2015
Resolved 8 April 2015
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 25 February 2015 Resolved
Repair/Remove ground from Engine room electrical distribution panel
Action required: 705 - Other - as specified
Due 25 March 2015
Resolved 8 April 2015
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 February 2015 Resolved
Repair outlet on 2nd deck aft stbd under cash register
Action required: 705 - Other - as specified
Due 25 March 2015
Resolved 8 April 2015
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 February 2015 Resolved
Remove excessive oil from engine room bilge
Action required: 705 - Other - as specified
Due 25 March 2015
Resolved 8 April 2015
Construction/Loadline › Structures › Deck Plating
Issued 20 January 2015 Resolved
Cut out and replace 2'x2' section of steel deck below the forward staircase on the port side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2015
Resolved 25 February 2015
Resolution: repairs satisfactory
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 November 2014 Resolved
Replace heat tape in number 4 void space.
Due 5 December 2014
Resolved 19 January 2015
Construction/Loadline › Structures › Manhole
Issued 5 November 2014 Resolved
Repair number 1 void hatch seal.
Due 5 December 2014
Resolved 19 January 2015
Construction/Loadline › Structures › Manhole
Issued 5 November 2014 Resolved
Repair gasket in number 3 void hatch cover.
Due 5 December 2014
Resolved 12 November 2014
Construction/Loadline › Hull › Bottom Plating
Issued 5 November 2014 Resolved
Make permenant repairs to hole in deck in starboard bow closet.
Due 31 January 2015
Resolved 5 November 2014
Construction/Loadline › Hull › Longitudinal Frame
Issued 5 November 2014 Resolved
Repair hole in starboard aft bulkhead.
Due 5 December 2014
Resolved 19 January 2015
Engineering › Bilge Water Management System › Valve
Issued 5 November 2014 Resolved
Ensure satisfactory operation of bilge system; service the valves.
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 18 December 2014
Resolution: Vessel granted COTP waiver to operate with alternative bilge system procedures until 2016 Dry-dock where re-design of system will take place.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 5 November 2014 Resolved
Replace expired oxygen bottle in forward bow closet.
Due 5 December 2014
Resolved 19 January 2015
Resolution: Oxygen bottle was not required by regulation and was removed from service.
Fire Fighting › Fire Hoses › Location
Issued 29 October 2014 Resolved
Re-install sign labeling third deck firestation.
Due 5 December 2014
Resolved 12 November 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 October 2014 Resolved
Affect repairs to electrical wiring in stern void.
Due 5 December 2014
Resolved 19 January 2015
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 October 2014 Resolved
Replace heat tape in stern void.
Due 5 December 2014
Resolved 19 January 2015
Lifesaving › Lifebuoys › Serviceable
Issued 20 August 2014 Resolved
Lifering on 0-3 Deck was found to be unserviceable due to aging.
Action required: 705 - Other - as specified
Due 1 September 2014
Resolved 2 September 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 20 August 2014 Resolved
Various lightbulbs on first and second deck were burned out.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2014
Resolved 2 September 2014
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 August 2014 Resolved
Uneven flooring on first deck discovered and poses a tripping hazard for passengers/crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2014
Resolved 2 September 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 15 May 2014 Resolved
Replace J hook brackets with approved marine type brackets
Due 1 January 2015
Resolved 16 January 2015
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 May 2014 Resolved
Wire pass through in deck of galley space was not stuffed with fire resistant packing.
Action required: 705 - Other - as specified
Due 15 June 2014
Resolved 27 June 2014
Resolution: Stuffing tube sealed with fire retardant material.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 May 2014 Resolved
Repair all around white light
Due 1 August 2014
Resolved 24 July 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 23 July 2013 Resolved
Protective frame was missing from glass globe.
Due 30 July 2013
Resolved 23 July 2013
Electrical › Lighting (service) › Lighting Fixture
Issued 23 July 2013 Resolved
Broken light bulb
Due 30 July 2013
Resolved 23 July 2013
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 23 July 2013 Resolved
Broken outlet box in galley overhead
Due 30 July 2013
Resolved 23 July 2013
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 23 July 2013 Resolved
Improper surge protective device UL Marine 1449
Due 30 July 2013
Resolved 26 July 2013
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 July 2013 Resolved
Install non conductive spacers between battery installations
Due 30 July 2013
Resolved 26 July 2013
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 23 July 2013 Resolved
replace flame screen on barge after fuel vent
Due 30 July 2013
Resolved 26 July 2013
Accommodation/Occupational Safety › Potable Water System › General
Issued 23 July 2013 Resolved
Small leak discovered in water piping located in the #2 void space
Due 30 July 2013
Resolved 26 July 2013
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 November 2012 Resolved
2 Child and 35 Adult lifejackets needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2012
Resolved 8 November 2012
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 August 2012 Resolved
20 Adult PFDs missing and 02 Child PFDs missing. Vessel rep attained proper quantity, but will be completing a full inventory to identify if vessel placards are incorrect and replace with proper count.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 23 August 2012
Resolution: Proper count of PFDs were onboard. Locker placards renumbered to show proper count.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 August 2012 Resolved
CO2 missing service tag on STBD side of UTV weather deck.
Action required: 705 - Other - as specified
Due 24 August 2012
Resolved 23 August 2012
Electrical › Electric Generation Source (service) › Generator
Issued 7 August 2012 Resolved
Barge Generator missing ground.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 7 August 2012
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 7 August 2012 Resolved
Locker for anchor chain did not have a properly mounted hinge assembly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2012
Resolved 7 August 2012
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 11 August 2010 Resolved
Repair/Replace A/C vent on the exterior deck port side amidships.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 September 2010
Resolved 11 August 2010
Resolution: Removed damaged portion of A/C vent.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2010 Resolved
Replace household bulbs in navigation lights with approved type bulbs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 13 September 2010
Resolution: Installed proper bulbs in navigation lights.
Accommodation/Occupational Safety › Potable Water System › General
Issued 11 August 2010 Resolved
Place pest screens over potable water vent on main deck stern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2010
Resolved 13 September 2010
Resolution: Screen placed on potable water vent on main deck stern.
Engineering › Bilge Water Management System › Valve
Issued 23 February 2010 Resolved
Bilge pump's suction valve was inoperable. The valve stem broke off from the valve and was unable to discharge the bilge water.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 2 March 2010
Resolution: Corrected.
Lifesaving › Lifebuoys › Serviceable
Issued 23 February 2010 Resolved
The two aft life buoy's on the main deck were deteriorated. The vessel is to replace with new one's.
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 2 March 2010
Resolution: Corrected.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 23 February 2010 Resolved
Vessel was missing the current edition of the Inland Navigation Rules. The vessel is to provide a current edition.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 2 March 2010
Resolution: Corrected.
Construction/Loadline › Hull › Weld
Issued 4 October 2006 Resolved
DRYDOCK VESSEL FOR REPAIRS TO FRACTURE IN A WELD IN THE #2 PORT VOID.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 5 October 2006
Resolution: REPAIRED SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 December 2005 Resolved
Either hard wire or install a receptacle in generator space to service fresh water pumps. Wiring must be supported at least every 18 inches.
Due 8 January 2006
Resolved 14 December 2005
Resolution: Wired through a junction box.
Engineering › Steering Gear System › Linkage
Issued 10 May 2005 Resolved
Prove proper operation of the steering system on the Gateway Liner.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2005
Resolved 12 May 2005
Fire Fighting › Semiportable CO2 Fire Extinguishers › Condition
Issued 29 April 2005 Resolved
Install and prove proper installation of either a fixed fire extinguishing sytem or a type B-V semi-portable extinguisher for the machinery spaces of the Gateway Liner, O.N. 273586.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 17 May 2005
Resolution: Type B-V semi-portable CO2 fire extinguisher properly installed.
Electrical › Electric Generation Source (emergency) › Generator
Issued 30 November 2004 Resolved
Correct exhaust leak in generator.
Due 5 January 2005
Resolved 9 March 2005
Resolution: Generator functioned properly during inspection.
Engineering › Bilge Water Management System › Pump
Issued 7 September 2004 Resolved
Prove proper operation of bilge system.
Due 13 September 2004
Resolved 9 September 2004
Resolution: Flapper in check valve removed and cleaned up. Operational test of system - sat.
Construction/Loadline › Structures
Issued 3 September 2003 Resolved
Make repairs to main deck house bulkhead, port side foward, at deck where wasted through to interior. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 3 October 2003
Resolved 15 September 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 3 September 2003 Resolved
Replace protective guards on incandescent lighting fixtures in forward deck stores and second deck bar room storage area.
Due 3 September 2003
Resolved 3 September 2003
Electrical › Electrical Distribution System (service) › Cable
Issued 3 September 2003 Resolved
Replace battery cable with type specified for service.
Due 3 September 2003
Resolved 3 September 2003
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 September 2003 Resolved
Properly identify circuit breakers for power panel "F" in galley area.
Due 3 September 2003
Resolved 3 September 2003
Engineering › Fuel Oil Service System › Valve
Issued 3 September 2003 Resolved
Prove proper operation of emergency fuel cut out reach rod for barge generator.
Due 3 September 2003
Resolved 3 September 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 March 2003 Resolved
Refill first aid kit and ensure all items required in 46 CFR 160.41-4 are in the kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2003
Resolved 14 March 2003
Resolution: Provided aspirin and splint.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 4 March 2003 Resolved
All trash receptacles that are not of approved incombustible material shall be removed from the vessel. LEGACY COMPONENT DESC: Furniture/Furnishings
Due 1 October 2004
Resolved 4 October 2004
Resolution: Combustible trashcans removed. Metal trashcans in use now.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 4 March 2003 Resolved
Provide mounting brackets for each portable fire extinguisher on board. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Due 4 May 2003
Resolved 20 May 2003
Resolution: Authorized to continue using brackets. Must renew brackets as the portable fire extinguishers are renewed.
Electrical › Lighting (emergency)
Issued 4 March 2003 Resolved
Renew stenciling of "E" on emergency light at top of portside stairway.
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 4 March 2003
Resolution: Corrected on scene.
Electrical › Lighting (service)
Issued 4 March 2003 Resolved
Renew globes on lighting fixtures in the 2nd deck bar portside storeroom and in the main deck forward portside locker. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 4 March 2003
Resolution: Corrected on scene.
Electrical › Electrical Distribution System (service)
Issued 4 March 2003 Resolved
Provide a covering plate for the switch/junction box where wiring is currently exposed at portside of 2nd deck bar. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 4 March 2003
Resolution: Corrected on scene
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 December 2002 Resolved
Replace two lifejackets with bad straps. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 10 December 2002
Resolution: Replaced two life jackets.
Lifesaving › Lifebuoys
Issued 10 December 2002 Resolved
Repair/replace two ring life buoys.
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 10 December 2002
Resolution: Replaced two ring life buoys.
Electrical › Electrical Distribution System (service)
Issued 10 September 2002 Resolved
Provide labels for circuits in the panelboard located behind the bar on the second deck. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 10 September 2002
Resolved 10 September 2002
Resolution: Circuits labeled.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 September 2002 Resolved
Properly mount the portable fire extinguisher located on the forward part of the second deck. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Due 10 September 2002
Resolved 10 September 2002
Resolution: Extinguisher mounted.
Engineering › Bilge Water Management System
Issued 26 June 2002 Resolved
Provide proposal to repair or replace bilge pump and or piping to ensure proper operation of the bilge pumping system. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 February 2003
Resolution: Proposal provived and approved. New bilge pump installed and satisfactory test witnessed.
Engineering › Bilge Water Management System › Pump
Issued 13 June 2002 Resolved
DEMONSTRATE PROPER OPERATION OF BILGE SYSTEM PRIOR TO CARRYING PASSENGERS.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2002
Resolved 14 June 2002
Resolution: CLEARED THIS DEF AND REISSUED FOR THE SAME PROBLEM.
Engineering › Bilge Water Management System
Issued 13 June 2002 Resolved
PROVIDE REPAIR/REPLACEMENT PROPOSAL TO THE BILGE SYSTEM, VESSEL SHALL CARRY TWO ELECTRIC SUBMERSIBLE PUMPS ONBOARD UNTIL PROPER OPERATION OF THE BILGE SYSTEM IS DEMONSTRATED. LEGACY COMPONENT DESC: Pump
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 March 2003
Resolved 17 June 2002
Resolution: Operators provided two submersible pumps that are carried onboard. The repair/replacement proposal requirement remains outstanding and will be reissued.
Lifesaving
Issued 4 June 2001 Resolved
PROVIDE CPR TRAINING.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Construction/Loadline
Issued 29 September 1999 Resolved
REPAIR/REPLACE PRIMARY BILGE PUMP. RETAIN PORTABLE BILGE PUMP ONBOARD UNTIL THIS REQUIREMENT CLEARED TO SATISFACTION OF LOCAL OCMI AND BY 29OCT99.
Condition: Unknown
Due 29 October 1999
Resolved 25 October 1999
Lifesaving
Issued 20 October 1998 Resolved
RENEW RETRO TAPE FWD PORT LIFERING.
Condition: Unknown
Due 25 November 1998
Resolved 11 December 1998
Electrical
Issued 20 October 1998 Resolved
REMOVE ELECTRICAL HEAT TAPE FROM VALVE LOCATED RAKE END STBD SIDE.
Condition: Unknown
Due 25 November 1998
Resolved 11 December 1998
Lifesaving
Issued 20 October 1998 Resolved
PROVIDE THREE ADULT PFD'S.
Condition: Unknown
Due 20 October 1998
Resolved 20 November 1998
Electrical
Issued 20 October 1998 Resolved
PROVIDE PROPER CONTAINMENT FOR EMERGENCY GENERATOR BATTERIES.
Condition: Unknown
Due 25 November 1998
Resolved 11 December 1998
Electrical
Issued 20 October 1998 Resolved
PROVIDE CIRCUIT BREAKER LIST FOR POWER PANEL "A" LOCATED IN GALLEY.
Condition: Unknown
Due 25 November 1998
Resolved 11 December 1998
Construction/Loadline
Issued 7 April 1998 Resolved
Submit a written proposal to bring vessels bilge piping system (pipe size and discharge capacity) into compliance with 46 CFR 56.50-50 (d) (3). Untilsuch time 2 portable electric bilge pumps shall be installed to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 17 July 1998
Resolved 14 July 1998
Lifesaving
Issued 16 September 1997 Resolved
REPLACE 514 ADULT, AND 38 CHILDRENS LIFEJACKETS REJECTED DURING INSPECTION.
Condition: Unknown
Due 16 September 1997
Resolved 16 September 1997
Construction/Loadline
Issued 17 July 1996 Resolved
TROUBLE SHOOT AND REPAIR BILGE PUMP/PIPING SYSTEM TO CORRECT SELF PRIMING PROBLEM.
Condition: Unknown
Due 17 July 1996
Resolved 17 July 1996
Engineering
Issued 18 August 1994 Resolved
Investigate and eliminate the cause of the diesel fumes in the #4 void.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994 Resolved
Make permanent repairs to wasted area of maindeck, port side as marked.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Electrical
Issued 18 August 1994 Resolved
Install emergency lighting in both the male and female heads.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Electrical
Issued 17 February 1994 Resolved
RENEW SHIPS SERVICE GENERATOR EXHAUST INSULATION.
Condition: Unknown
Due 17 March 1994
Resolved 21 March 1994
Electrical
Issued 17 February 1994 Resolved
REPLACE "O" RING ON SHIPS SERV. GENERATOR OIL COOLOER AND PROVE PROPER OPERATION OF THE SAME.
Condition: Unknown
Due 17 March 1994
Resolved 21 March 1994
Construction/Loadline
Issued 17 February 1994 Resolved
GAUGE AND WELD VARIOUS CRACKED WELDS ON MAIN DECK HOUSE EXTERNAL BULKHEADS ON PORT AND STBD. SIDES.
Condition: Unknown
Due 17 March 1994
Resolved 21 March 1994
Electrical
Issued 17 February 1994 Resolved
REMOVE ALL NYLON WIRE TIES THROUGHTOUT VESSEL AND REPLACE WITH METAL WIRE TIES.
Condition: Unknown
Due 17 March 1994
Resolved 21 March 1994
Electrical
Issued 17 February 1994 Resolved
REPAIR AND PROVE PROPER OPERATION OF GALLEY AND PORT BOW INTERCOM UNITS.
Condition: Unknown
Due 17 March 1994
Resolved 21 March 1994
Engineering
Issued 29 September 1993 Resolved
Prove proper operation of the emergency fuel cut-out reach rod for the emergency generator.
Condition: Unknown
Due 30 September 1993
Resolved 30 September 1993
Fire Fighting
Issued 11 March 1991 Resolved
TEST ALL FIRE HOSE TO NOT LESS THAN 100 P.S.I. AS REQUIRED BY 46 CFR 71.25-20(a)(4).
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Accommodation/Occupational Safety
Issued 21 September 1989 Resolved
MAKE ALL BULKHEADS IN STAIRWELL TO CONFORM TO 46CFR72.05-10.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Electrical
Issued 21 September 1989 Resolved
INSTALL QUICK DISCONNECT FITTINGS ON ALL UMBILICAL CORDS BETWEEN THE BARGE AND THE TOWBOAT.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Unknown
Issued 21 September 1989 Resolved
PROVIDE AN ACCEPTABLE MEANS OF COMMUNICATIONS BETWEEN DECKHANDS AND PILOTHOUSE DURING EMERGENCIES.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Accommodation/Occupational Safety
Issued 21 September 1989 Resolved
INSTALL ACCEPTABLE MEANS OF SECURING ENGINE ROOM VENTILATION DAMPNERS AND COVERS.SEAL TO PREVENT AIR FROM ENTERING WHEN CLOSED.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Fire Fighting
Issued 21 September 1989 Resolved
MAKE PERMANENT REPAIRS TO THE INSTALLED FIRE PUMP AND FIREMAIN PIPING AND SHOW PROOF OF PROPER OPERATION IAW 46CFR76.10-5
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Lifesaving
Issued 21 September 1989 Resolved
MAKE PERMANENT REPAIRS TO THE RESCUE BOAT SEAT.
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Accommodation/Occupational Safety
Issued 21 September 1989 Resolved
INSTALL SELF-CLOSING DEVICE ON STAIRWELL DOOR OF THIRD DECK IAW 46CFR72.05-50
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Accommodation/Occupational Safety
Issued 21 September 1989 Resolved
REMOVE ALL MEANS OF HOLDING STAIRWELL DOORS OPEN IAW 46CFR72.05-50(B)(9)
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Electrical
Issued 21 September 1989 Resolved
SHOW PROOF OF PROPER OPERATION OF GENERATOR OVERSPEED DEVICE IAW 46CFR111.12-1(B)
Condition: Unknown
Due 21 September 1989
Resolved 21 September 1989
Construction/Loadline
Issued 24 March 1987 Resolved
MAKE PERMANENT REPAIRS TO FORWARD BULKHD IN WAY OF STBD CLOSET ABOVE MAIN DECK.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Engineering
Issued 24 March 1987 Resolved
INSTALL REMOTE REACH ROD FOR BILGE SUCTION VALVE IN FORPEAK VOID.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Electrical
Issued 18 December 1986 Resolved
REMOVE UNSUSED WIRING ON EMERGENCY GENERATOR CHARGING SYSTEM.
Condition: Unknown
Due 18 December 1986
Resolved 18 December 1986
Accommodation/Occupational Safety
Issued 18 December 1986 Resolved
INSTALL CHECK VALVE IN OVERBOARD DISCHARGE PIPING FROM MSD.
Condition: Unknown
Due 18 December 1986
Resolved 18 December 1986
Unknown
Issued 17 January 1986 Resolved
TEST RUN BILGE PUMP PRIOR TO 15MAR86.
Condition: Unknown
Due 17 January 1986
Resolved 17 January 1986
Construction/Loadline
Issued 7 January 1986 Resolved
PRESENT FOR COAST GUARD INSPECTION THE #2 VOID, PORT SIDE NOT LATER THAN 20JAN86.
Condition: Unknown
Due 7 January 1986
Resolved 7 January 1986
Accommodation/Occupational Safety
Issued 20 September 1985 Resolved
SUBMIT PLANS FOR ELECTRICAL AND MECHANICAL SYSTEMS OF RECENT AIR CONDITION-ING PLANT INSTALLATION.
Condition: Unknown
Due 20 September 1985
Resolved 20 September 1985
Electrical
Issued 21 June 1985 Resolved
INSTALL RUBBER MATTING IN FRONT OF THE ELECTRICAL SWITCHBOARD LOCATED DOWN IN ENGINEROOM.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985
Electrical
Issued 21 June 1985 Resolved
MAKE ELECTRICAL CONNECTION LEADING INTO THE VESSEL HEADING FLASH WATER- TIGHT.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985
Electrical
Issued 21 June 1985 Resolved
MAKE PLUG AND RECEPTICLE CONNECTION WHICH IS UTILIZED TO SUPPLY POWER TO THE GOOD HUMOR MACHINE LOCATED ON THE THIRD DECK WATERTIGHT.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.