Records from 2007 to 2026. Most recent: inspection, 19 February 2026.
Inspection history · 26
19 February 2026
Annual Inspection · Administrative Inspection · MSP Additional Oversight - Risk Assessment · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8312983
13 June 2025
MTSA Verification · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8157892
22 April 2025
Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8116954
6 March 2025
Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8104964
4 January 2025
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8058961
4 January 2025
Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8059546
16 April 2024
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7896253
26 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7882913
31 August 2023
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7782318
17 May 2023
In-Service Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7691238
5 April 2023
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7658576
25 July 2022
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7516362
24 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7470074
8 March 2022
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7403664
23 March 2021
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7331612
16 March 2021
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7156927
17 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7096857
22 April 2020
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7148829
20 February 2020
Examination of Repairs · Drydock Exam · Internal Structural Exam · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6916759
19 March 2019
Administrative Inspection · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6645274
16 April 2018
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6394012
12 August 2017
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6265064
9 August 2017
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6235405
14 March 2017
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6085471
27 April 2016
Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5868158
5 April 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5848553
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 February 2026
Resolved
A carbon dioxide cylinder may be inclined not more than 30* from the vertical, unless fitted with flexible or bent siphon tubes, in which case they may be inclined not more than 80* from the vertical. Vessel has two cylinders installed with bent siphon tubes at an approximate 45* incline. The bottles are labeled in two locations, at the cylinder head and along the cylinder itself, as to which side needs to face up. It was found that the forward bottle is installed upside down (markings facing down). Ensure the system is installed as designed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2026
Resolved 5 March 2026
Resolution: Attended vessel, confirmed bottles stowed properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The child life jackets are separated from the adult life jackets; however there was adult lifejackets mixed amongst them in the locker. Ensure child size lifejackets are completely separated from adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 5 March 2026
Resolution: Attended vessel, confirmed lifejacket stowage is within compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2026
Resolved
A vessel must have one or more ring life buoys as follows: (1) be approved in accordance with §160.050 in subchapter Q of this chapter. The forward main deck lifebuoy grablines are deteriorated and the port upper deck life buoy was losing its reflective tape. Repair or replace grab line and reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 5 March 2026
Resolution: Attended vessel, confirmed both life buoys have been replaced/repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 January 2025
Resolved
All engines must be water cooled; to include the head, block, and exhaust manifold. The jacket water hose clamp became loose at the keel cooler and leaked coolant into the bilge. Repair/replace hose clamp, refill jacket water, test under load.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2025
Resolved 7 January 2025
Resolution: Observed Generator operate under load at temperature.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 26 March 2024
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. Sewage pipe connection to marine sanitation device leaking. Properly support and realign pipe so it no longer leaks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 16 April 2024
Resolution: Properly supported pipe with hanger and repaired leak.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 26 March 2024
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Untreated sewage was found covering the deck of the sanitation space. Clean and disinfect space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 16 April 2024
Resolution: Space cleaned
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2024
Resolved
Except bilge-manifold valve controlling a bilge suction from any compartment must be of the stop-check type. Stop check valve found leaking in void space forward of sanitation space. Repair valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 16 April 2024
Resolution: Valve disassembled and repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2024
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Battery terminals on starboard engine found loose. CORRECTED ON THE SPOT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 March 2024
Resolution: Corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 May 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Engine Room is equipped with only one means of exit/entry as it is NOT normally used by the crew. No markings were present indicating to keep area clear. Install markings as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: Signage installed as required
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 May 2023
Resolved
Means of escape means a continuous and unobstructed way of exit travel from any point in a vessel to an embarkation station or area of refuge. Engine room exit hatch surrounded by storage of loose gear that is a potential obstruction to exit. Remove gear from space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: Gear removed from space
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2023
Resolved
The master or person-in-charge must ensure that the CO2 lockout valve is locked open at all times, except while maintenance is being performed on the extinguishing system, when the valve must be locked in the closed position. Lockout valve is not locked into position. Provide means to lock valve as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: Lock was installed as required
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2023
Resolved
Inspections and maintenance of portable fire extinguishers must meet requirements of Chapter 4 of NFPA 10 with the frequency specified by NFPA 10. Improper install and monthly inspection missed on pilot house extinguisher. Inspect and mount as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: Fire extinguisher properly mounted and inspected as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2023
Resolved
Exhaust gas must not leak from the piping or any connections. Small exhaust leak found at port muffler in CO2 storage space. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: No leak was identified. Soot found was from previous leak that was repaired. Crew cleaned old exhaust from lagging to prevent future incident.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2023
Resolved
Each vessel must be provided with visual and audible alarm at the operating station to indicate a high water level in machinery space bilges subject to flooding. The port bilge high level under the port shaft seal was inoperable and did not alarm when tested during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 April 2023
Resolved 18 April 2023
Resolution: BIlge switch replaced as required. Operational test SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, flooding, heavy weather, or man overboard conditions. Emergency instructions were not mounted at the operating station. Mount emergency instructions at operating station.
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 18 April 2023
Resolution: Emergency instructions posted as required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2023
Resolved
A station bill must be posted by the master of the vessel of more than 65 feet having a Certificate of Inspection requiring more than four crew members at any one time, including the master. Station bill was not posted at the operating station or in a conspicuous location accessible to the crew.
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 18 April 2023
Resolution: Station bill posted in Pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2022
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter. 160.050.3 - The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. The port bridge ring life buoy grab line is wasted. Replace with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Replaced Life bouy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The folloiwng deficiencies were identified:
1) Two openings found in galley electrical panel #2
2) Two openings found in 1st deck bar electrical panel
3) Opening found in main generator breaker switch
4) Deadend wires found in engine room overhead
5) Starboard main engine battery terminal improperly attached
6) Opening found in port side generator (Missing knock-out)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2022
Resolution: All items corrected to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2022
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable.
46 CFR 111.60-13(b)No flexible cord may be used except:
(1) As allowed under Sections 400-7 and 400-8 of NFPA NEC 2002; and
(2) In accordance with Table 400-4 in NFPA NEC 2002.
NFPA NEC 2002- Unless specifically permitted in
400.10, flexible cables, flexible cord sets, and power supply
cords shall not be used for the following:
(1) As a substitute for the fixed wiring of a structure. Extention cord found left plugged in Engine Room. Remove as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Extension cord removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2022
Resolved
Exhaust gas must not leak from the piping or any connections. Exhaust leak found on starboard main engine. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Replaced gaskets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 March 2022
Resolved
Internal combustion engine exhausts must be kept clear of and suitably insulated from combustible material. Starboard generator exhaust pipe out of turbo not insulated. Remove installed cage and insulate as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Installed insulation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 March 2022
Resolved
Doors in A-Class fire control boundaries must meet the requirements of an A-15 Class bulkhead. Engine room hatch leading under stairway missing required structural fire protection. Install fire protection as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Structural fire protection installed on engine room hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 March 2022
Resolved
A vessel on a rivers route must carry: 3 hand red flare & 3 hand orange smoke distress signals or 6 hand red flare distress signals. Vessel only has 3 hand red flares on board. Provide mandatory flares as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: 03 Hand red flares added to vessel distress signal inventory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2022
Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with §164.018. Retroreflective material on 4 life jackets on 2nd deck no longer effective. Replace worn reto as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: wasted retroreflective tape replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 March 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Fasteners installed for structural fire protection protrudes through fire protection and terminates to a sharp point. Trim fasteners to prevent injury once fire blankets are installed over structural fire protection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2022
Resolved 25 July 2022
Resolution: Fasteners trimmed as required.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 March 2022
Resolved
For vessels contracted for prior to August 22, 2016, extinguishers with extinguishing capacities smaller than what is required in Table 118.500(a) of this part need not be replaced and may be continued in service so long as they are maintained in good condition to the satisfaction of the [name withheld]2 pull support in tank space missing screw. Replace fastener as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Support screw replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2021
Resolved
mendments to a Vessel Security Plan (VSP) are approved by the Marine Safety Center (MSC). Information for submitting the VSP electronically can be found at http://www.uscg.mil/HQ/MSC. Last amendments to VSP dated April 2011 have outdated information. Send correspondence to MSC for the following corrections:
1. New CSO/VSO
2. Majestic no longer part of VSP
3. Official number for DUCHESS incorrect
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2021
Resolution: Submitted required updates to VSP to MSC
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2021
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 millimeters (4 inches) square. Life jacket containers on 3rd deck are missing required markings. Apply markings as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2021
Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with §164.018. Retroreflective material on child life jackets on 3rd deck no longer effective. Replace worn reto as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2021
Resolved
Each individual bilge suction shall be fitted with a suitable bilge strainer having an open area of not less than three times at of the suction pipe. In addition a mud box or basket strainer shall be fitted in an accessible position between the bilge suction manifold and the pump. Bilge suction strainer located in void space under galley is not properly attached and of unsuitable material. Provide a permanent strainer for bilge suction.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2021
Resolved
For vessels less than 150 gross tons no bilge suction shall be less than 1 1/2 inches internal diameter and no branch piping shall be less than 1 inch nominal pipe size. Bilge suction in sewage space is pressed directly against the deck preventing its use. Raise bilge suction to allow appropriate operation as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 September 2019
Resolved
Provide and install markings, signs, and instructions for new fixed fire fighting system ay local and remote activation, audible alarm, storage, and stop valve locations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2019
Resolved 21 October 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 March 2019
Resolved
Forepeak flush deck hatch not watertight. Prove watertight in the presence of the attending CG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 March 2019
Resolved
CO2 storage cylinder for fixed fire suppression system mounted on an incline beyond 30 degrees. Cylinders do not indicate type of syphon tube or any indication of proper installation orientation. Prove proper inclined installation of CO2 storage cylinders to the satisfaction of the attending CG MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 27 September 2019
Resolution: New system installed, pie testing and operational testing of system satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 27 March 2019
Resolved
Visual Distress Signal stowage container marked with improper vessel name and "Flares". Properly mark Visual Distress Signal stowage case to the satisfaction of the attending CG MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 15 May 2019
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 April 2018
Resolved
Separate child and adult PFD's on second deck storage locker and mark location IAW regulations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 10 May 2018
Resolution: PFD's properly separated and labeled
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 April 2018
Resolved
Remove wing nuts from batteries and install permanent type fasteners.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 10 May 2018
Resolution: Wing nuts removed and permanent type fasteners installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2018
Resolved
Remove hull grounds from high water bilge alarm circuits.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2018
Resolved 10 May 2018
Resolution: High bilge alarm level switches properly wired.
Lifesaving › Lifebuoys › Serviceable
Issued 16 April 2018
Resolved
Replace deteriorated lifeline on forward lifebuoy
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 10 May 2018
Resolution: New lifeline installed.
Navigation › Piloting/Steering › Advance/Transfer
Issued 9 August 2017
Resolved
Vessel unable to maneuver as designed. Repair to original design.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2017
Resolved 11 August 2017
Resolution: Replaced missing flange bolts with new.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 14 March 2017
Resolved
Annual VGP inspection not completed in 2016.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Lifesaving › Hand Flares › Not on Board
Issued 14 March 2017
Resolved
Vessel did not have three red flares on board.
Due 14 April 2017
Resolved 12 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 14 March 2017
Resolved
Port and starboard engine dry exhaust piping missing required lagging.
Due 14 April 2017
Resolved 12 April 2017
Fire Fighting › Combustible Materials › Linings
Issued 14 March 2017
Resolved
Vessel equipped with a oil soaked rug in the engine room.
Condition: Improper Installation
Due 14 April 2017
Resolved 12 April 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 March 2017
Resolved
First aid kit missing iodine, ammonia, aspirin.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 14 March 2017
Resolved
A-0 boundary for engine room compromised due to altered hatch.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Lifesaving › Lifebuoys › Serviceable
Issued 14 March 2017
Resolved
Starboard open bridge life ring worn.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 March 2017
Resolved
Starboard open bridge life ring light line worn.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 14 March 2017
Resolved
Starboard engine oil pressure gauge on bridge OOC.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 14 March 2017
Resolved
Company has not reported positive drug test results for pre-employment, has no past record of positive drug test, cannot provide evidence of mandatory training, records conflict with consortium MIS data.
Condition: Invalid
Due 14 April 2017
Resolved 14 April 2017