Records from 1985 to 2026. Most recent: inspection, 19 February 2026.
Inspection history · 112
19 February 2026
Annual Inspection · Administrative Inspection · MSP Additional Oversight - Risk Assessment · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8312983
13 June 2025
MTSA Verification · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8157892
22 April 2025
Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8116954
6 March 2025
Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8104964
4 January 2025
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8058961
4 January 2025
Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8059546
16 April 2024
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7896253
26 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7882913
31 August 2023
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7782318
17 May 2023
In-Service Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7691238
5 April 2023
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7658576
25 July 2022
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7516362
24 May 2022
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7470074
8 March 2022
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7403664
23 March 2021
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7331612
16 March 2021
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7156927
17 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7096857
22 April 2020
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7148829
20 February 2020
Examination of Repairs · Drydock Exam · Internal Structural Exam · Plan Review (Other than "T")
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6916759
19 March 2019
Administrative Inspection · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6645274
16 April 2018
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6394012
12 August 2017
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6265064
9 August 2017
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6235405
14 March 2017
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6085471
27 April 2016
Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5868158
5 April 2016
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5848553
20 June 2014
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4908594
7 May 2014
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4852615
14 March 2014
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4817501
3 January 2012
In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4239967
11 September 2011
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4149755
30 October 2010
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3882528
29 October 2010
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3882502
23 March 2010
Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3701080
18 March 2009
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3435700
13 March 2009
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3434157
12 March 2009
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3434078
3 November 2008
Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3357229
19 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3241440
27 March 2008
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3171637
3 May 2007
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2922085
22 March 2007
COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2891219
8 August 2006
Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2740010
11 July 2006
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2716006
10 July 2006
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2710414
21 March 2006
Inclining Experiment · Annual Inspection · Construction Oversight
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2612037
13 November 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2534408
13 November 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2534449
16 October 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2516153
16 October 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2516163
28 September 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2516064
28 September 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2546996
25 September 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2531529
25 August 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2547006
6 August 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2455490
30 July 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2447663
24 July 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2447614
21 July 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2546972
10 July 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2447549
9 July 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2447488
9 July 2005
Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2546963
25 April 2005
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2351117
30 March 2005
Periodic Inspection · MTSA Verification
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2321966
4 October 2004
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2225980
1 April 2004
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2035267
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963264
10 October 2003
Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1925384
1 October 2003
Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1937464
10 July 2003
Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1841528
20 May 2003
Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1813398
2 April 2003
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1766631
24 March 2003
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1744303
18 March 2003
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1758789
3 April 2002
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1600353
6 April 2001
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1412251
5 April 2000
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1404940
6 April 1999
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1395155
25 February 1999
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 215291
23 April 1998
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1381227
31 March 1998
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1438678
25 August 1997
Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1458453
23 August 1997
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 157349
9 April 1997
Examination of Repairs · Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1388253
25 March 1997
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1100604
11 April 1996
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1078519
11 April 1995
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 829385
10 February 1995
Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1360036
18 May 1994
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 860027
12 April 1994
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 853717
19 December 1993
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1162944
15 April 1993
COI Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 835363
15 April 1993
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1146285
15 April 1993
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1146287
31 March 1993
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1146286
26 July 1992
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 952367
16 April 1992
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1270438
12 March 1992
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 948465
10 January 1992
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 952627
17 April 1991
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1213013
7 March 1991
Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1213074
18 April 1990
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1216163
18 April 1989
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1044144
5 April 1989
Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1039043
17 March 1989
Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1210627
18 April 1988
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1032453
16 March 1988
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1299787
21 April 1987
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1325204
30 June 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1305246
23 April 1986
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1307364
8 May 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1286137
23 April 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 982544
8 April 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 979760
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 February 2026
Resolved
A carbon dioxide cylinder may be inclined not more than 30* from the vertical, unless fitted with flexible or bent siphon tubes, in which case they may be inclined not more than 80* from the vertical. Vessel has two cylinders installed with bent siphon tubes at an approximate 45* incline. The bottles are labeled in two locations, at the cylinder head and along the cylinder itself, as to which side needs to face up. It was found that the forward bottle is installed upside down (markings facing down). Ensure the system is installed as designed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2026
Resolved 5 March 2026
Resolution: Attended vessel, confirmed bottles stowed properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The child life jackets are separated from the adult life jackets; however there was adult lifejackets mixed amongst them in the locker. Ensure child size lifejackets are completely separated from adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 5 March 2026
Resolution: Attended vessel, confirmed lifejacket stowage is within compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2026
Resolved
A vessel must have one or more ring life buoys as follows: (1) be approved in accordance with §160.050 in subchapter Q of this chapter. The forward main deck lifebuoy grablines are deteriorated and the port upper deck life buoy was losing its reflective tape. Repair or replace grab line and reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2026
Resolved 5 March 2026
Resolution: Attended vessel, confirmed both life buoys have been replaced/repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 January 2025
Resolved
All engines must be water cooled; to include the head, block, and exhaust manifold. The jacket water hose clamp became loose at the keel cooler and leaked coolant into the bilge. Repair/replace hose clamp, refill jacket water, test under load.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2025
Resolved 7 January 2025
Resolution: Observed Generator operate under load at temperature.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 26 March 2024
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. Sewage pipe connection to marine sanitation device leaking. Properly support and realign pipe so it no longer leaks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 16 April 2024
Resolution: Properly supported pipe with hanger and repaired leak.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 26 March 2024
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. Untreated sewage was found covering the deck of the sanitation space. Clean and disinfect space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 16 April 2024
Resolution: Space cleaned
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 March 2024
Resolved
Except bilge-manifold valve controlling a bilge suction from any compartment must be of the stop-check type. Stop check valve found leaking in void space forward of sanitation space. Repair valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2024
Resolved 16 April 2024
Resolution: Valve disassembled and repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 March 2024
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Battery terminals on starboard engine found loose. CORRECTED ON THE SPOT.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 March 2024
Resolution: Corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 May 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Engine Room is equipped with only one means of exit/entry as it is NOT normally used by the crew. No markings were present indicating to keep area clear. Install markings as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: Signage installed as required
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 May 2023
Resolved
Means of escape means a continuous and unobstructed way of exit travel from any point in a vessel to an embarkation station or area of refuge. Engine room exit hatch surrounded by storage of loose gear that is a potential obstruction to exit. Remove gear from space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: Gear removed from space
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 May 2023
Resolved
The master or person-in-charge must ensure that the CO2 lockout valve is locked open at all times, except while maintenance is being performed on the extinguishing system, when the valve must be locked in the closed position. Lockout valve is not locked into position. Provide means to lock valve as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: Lock was installed as required
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2023
Resolved
Inspections and maintenance of portable fire extinguishers must meet requirements of Chapter 4 of NFPA 10 with the frequency specified by NFPA 10. Improper install and monthly inspection missed on pilot house extinguisher. Inspect and mount as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: Fire extinguisher properly mounted and inspected as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 May 2023
Resolved
Exhaust gas must not leak from the piping or any connections. Small exhaust leak found at port muffler in CO2 storage space. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2023
Resolved 31 August 2023
Resolution: No leak was identified. Soot found was from previous leak that was repaired. Crew cleaned old exhaust from lagging to prevent future incident.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2023
Resolved
Each vessel must be provided with visual and audible alarm at the operating station to indicate a high water level in machinery space bilges subject to flooding. The port bilge high level under the port shaft seal was inoperable and did not alarm when tested during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 April 2023
Resolved 18 April 2023
Resolution: BIlge switch replaced as required. Operational test SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, flooding, heavy weather, or man overboard conditions. Emergency instructions were not mounted at the operating station. Mount emergency instructions at operating station.
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 18 April 2023
Resolution: Emergency instructions posted as required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2023
Resolved
A station bill must be posted by the master of the vessel of more than 65 feet having a Certificate of Inspection requiring more than four crew members at any one time, including the master. Station bill was not posted at the operating station or in a conspicuous location accessible to the crew.
Action required: 10 - Deficiency Rectified
Due 26 April 2023
Resolved 18 April 2023
Resolution: Station bill posted in Pilothouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2022
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter. 160.050.3 - The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. The port bridge ring life buoy grab line is wasted. Replace with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Replaced Life bouy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The folloiwng deficiencies were identified:
1) Two openings found in galley electrical panel #2
2) Two openings found in 1st deck bar electrical panel
3) Opening found in main generator breaker switch
4) Deadend wires found in engine room overhead
5) Starboard main engine battery terminal improperly attached
6) Opening found in port side generator (Missing knock-out)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2022
Resolution: All items corrected to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 March 2022
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable.
46 CFR 111.60-13(b)No flexible cord may be used except:
(1) As allowed under Sections 400-7 and 400-8 of NFPA NEC 2002; and
(2) In accordance with Table 400-4 in NFPA NEC 2002.
NFPA NEC 2002- Unless specifically permitted in
400.10, flexible cables, flexible cord sets, and power supply
cords shall not be used for the following:
(1) As a substitute for the fixed wiring of a structure. Extention cord found left plugged in Engine Room. Remove as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Extension cord removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2022
Resolved
Exhaust gas must not leak from the piping or any connections. Exhaust leak found on starboard main engine. Repair as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Replaced gaskets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 March 2022
Resolved
Internal combustion engine exhausts must be kept clear of and suitably insulated from combustible material. Starboard generator exhaust pipe out of turbo not insulated. Remove installed cage and insulate as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Installed insulation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 March 2022
Resolved
Doors in A-Class fire control boundaries must meet the requirements of an A-15 Class bulkhead. Engine room hatch leading under stairway missing required structural fire protection. Install fire protection as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Structural fire protection installed on engine room hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 March 2022
Resolved
A vessel on a rivers route must carry: 3 hand red flare & 3 hand orange smoke distress signals or 6 hand red flare distress signals. Vessel only has 3 hand red flares on board. Provide mandatory flares as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: 03 Hand red flares added to vessel distress signal inventory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2022
Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with §164.018. Retroreflective material on 4 life jackets on 2nd deck no longer effective. Replace worn reto as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: wasted retroreflective tape replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 March 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Fasteners installed for structural fire protection protrudes through fire protection and terminates to a sharp point. Trim fasteners to prevent injury once fire blankets are installed over structural fire protection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 April 2022
Resolved 25 July 2022
Resolution: Fasteners trimmed as required.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 March 2022
Resolved
For vessels contracted for prior to August 22, 2016, extinguishers with extinguishing capacities smaller than what is required in Table 118.500(a) of this part need not be replaced and may be continued in service so long as they are maintained in good condition to the satisfaction of the [name withheld]2 pull support in tank space missing screw. Replace fastener as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 April 2022
Resolution: Support screw replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2021
Resolved
mendments to a Vessel Security Plan (VSP) are approved by the Marine Safety Center (MSC). Information for submitting the VSP electronically can be found at http://www.uscg.mil/HQ/MSC. Last amendments to VSP dated April 2011 have outdated information. Send correspondence to MSC for the following corrections:
1. New CSO/VSO
2. Majestic no longer part of VSP
3. Official number for DUCHESS incorrect
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2021
Resolution: Submitted required updates to VSP to MSC
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2021
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 millimeters (4 inches) square. Life jacket containers on 3rd deck are missing required markings. Apply markings as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2021
Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with §164.018. Retroreflective material on child life jackets on 3rd deck no longer effective. Replace worn reto as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2021
Resolved
Each individual bilge suction shall be fitted with a suitable bilge strainer having an open area of not less than three times at of the suction pipe. In addition a mud box or basket strainer shall be fitted in an accessible position between the bilge suction manifold and the pump. Bilge suction strainer located in void space under galley is not properly attached and of unsuitable material. Provide a permanent strainer for bilge suction.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2021
Resolved
For vessels less than 150 gross tons no bilge suction shall be less than 1 1/2 inches internal diameter and no branch piping shall be less than 1 inch nominal pipe size. Bilge suction in sewage space is pressed directly against the deck preventing its use. Raise bilge suction to allow appropriate operation as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 September 2019
Resolved
Provide and install markings, signs, and instructions for new fixed fire fighting system ay local and remote activation, audible alarm, storage, and stop valve locations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2019
Resolved 21 October 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 March 2019
Resolved
Forepeak flush deck hatch not watertight. Prove watertight in the presence of the attending CG MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 15 May 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 March 2019
Resolved
CO2 storage cylinder for fixed fire suppression system mounted on an incline beyond 30 degrees. Cylinders do not indicate type of syphon tube or any indication of proper installation orientation. Prove proper inclined installation of CO2 storage cylinders to the satisfaction of the attending CG MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 27 September 2019
Resolution: New system installed, pie testing and operational testing of system satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 27 March 2019
Resolved
Visual Distress Signal stowage container marked with improper vessel name and "Flares". Properly mark Visual Distress Signal stowage case to the satisfaction of the attending CG MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 15 May 2019
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 April 2018
Resolved
Separate child and adult PFD's on second deck storage locker and mark location IAW regulations.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 10 May 2018
Resolution: PFD's properly separated and labeled
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 April 2018
Resolved
Remove wing nuts from batteries and install permanent type fasteners.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 10 May 2018
Resolution: Wing nuts removed and permanent type fasteners installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2018
Resolved
Remove hull grounds from high water bilge alarm circuits.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2018
Resolved 10 May 2018
Resolution: High bilge alarm level switches properly wired.
Lifesaving › Lifebuoys › Serviceable
Issued 16 April 2018
Resolved
Replace deteriorated lifeline on forward lifebuoy
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2018
Resolved 10 May 2018
Resolution: New lifeline installed.
Navigation › Piloting/Steering › Advance/Transfer
Issued 9 August 2017
Resolved
Vessel unable to maneuver as designed. Repair to original design.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2017
Resolved 11 August 2017
Resolution: Replaced missing flange bolts with new.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 14 March 2017
Resolved
Annual VGP inspection not completed in 2016.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Lifesaving › Hand Flares › Not on Board
Issued 14 March 2017
Resolved
Vessel did not have three red flares on board.
Due 14 April 2017
Resolved 12 April 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 14 March 2017
Resolved
Port and starboard engine dry exhaust piping missing required lagging.
Due 14 April 2017
Resolved 12 April 2017
Fire Fighting › Combustible Materials › Linings
Issued 14 March 2017
Resolved
Vessel equipped with a oil soaked rug in the engine room.
Condition: Improper Installation
Due 14 April 2017
Resolved 12 April 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 March 2017
Resolved
First aid kit missing iodine, ammonia, aspirin.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 14 March 2017
Resolved
A-0 boundary for engine room compromised due to altered hatch.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Lifesaving › Lifebuoys › Serviceable
Issued 14 March 2017
Resolved
Starboard open bridge life ring worn.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 March 2017
Resolved
Starboard open bridge life ring light line worn.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 14 March 2017
Resolved
Starboard engine oil pressure gauge on bridge OOC.
Condition: Improper/Lack of Maintenance
Due 14 April 2017
Resolved 12 April 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 14 March 2017
Resolved
Company has not reported positive drug test results for pre-employment, has no past record of positive drug test, cannot provide evidence of mandatory training, records conflict with consortium MIS data.
Condition: Invalid
Due 14 April 2017
Resolved 14 April 2017
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 14 March 2014
Resolved
Provide adequate lighting for third deck aft walkway in vacinity of life jacket storage lockers.
Due 28 April 2014
Resolved 22 April 2014
Fire Fighting › Structural - A Class Divisions › Doors
Issued 14 March 2014
Resolved
Repair throw/latch on 2nd deck weatherdeck doors.
Due 28 April 2014
Resolved 22 April 2014
Engineering › Lubricating Oil Service System › Gauge
Issued 14 March 2014
Resolved
Repair lube oil guage in pilot house
Due 28 April 2014
Resolved 22 April 2014
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 14 March 2014
Resolved
Repair oil leak in generator
Due 28 April 2014
Resolved 22 April 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 14 March 2014
Resolved
Repair hydraulic oil leak in port MDE
Due 28 April 2014
Resolved 22 April 2014
Stability › Watertight Integrity › General
Issued 23 March 2010
Resolved
Vessel is to repair a broken pipe that lead overboard starboard side #4 void space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2010
Resolved 24 March 2010
Resolution: Vessel welded a plug to seal off the through hole and removed the old unused pipe to the satisfaction of the attending Coast Guard Marine Inspector.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 August 2006
Resolved
VESSELS HULL WAS EXTENDED. NEED TO CHANGE LENGTH AND TONNAGE DIMENSIONS WITH NVDC AND INSTALL A TONNAGE PLATE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2007
Resolved 27 March 2008
Resolution: CORRECTED.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 March 2005
Resolved
Remove electrical receptacle or replace with a ground fault receptacle on the first floor bar, starboard side, IWO sink.
Due 30 April 2005
Resolved 25 April 2005
Resolution: GFI receptacle installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 March 2005
Resolved
Provide proof of hydro test on fixed CO2 bottles within the past 12 years.
Due 30 April 2005
Resolved 25 April 2005
Resolution: CO2 bottles stamped w/hydro date by fire servicing company (5/05).
Engineering › Diesel Engine (propulsion-direct drive)
Issued 2 April 2003
Resolved
Repair insulation on all engine exhaust piping in engine room. LEGACY COMPONENT DESC: Exhaust Pipe Insulation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 25 April 2003
Resolution: Insulation repaired or renewed satisfactorly.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 2 April 2003
Resolved
Provide incombustable trash containers. LEGACY COMPONENT DESC: Furniture/Furnishings
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2004
Resolved 4 October 2004
Resolution: Combustible trashcans removed. Metal trashcans in use now.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 2 April 2003
Resolved
Provide marine fire ext. brackets. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2003
Resolved 20 May 2003
Resolution: Authorized to continue using brackets. Must renew brackets as the portable fire extinguishers are renewed.
Lifesaving › Lifebuoys
Issued 3 April 2002
Resolved
Grabline around starboard pilot house life-ring was wasted, and breaking when manipulated. CG-835 required replace grabline. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2002
Resolution: Ring replaced by maintenance manager.
Lifesaving › Lifebuoys
Issued 3 April 2002
Resolved
Forward maindeck life-ring had breaks in outer layer and small patches into the foam. CG-835 issued requireing replace/repair ring.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2002
Resolution: Ring repaired using manufactures patch kit to MI satisfaction.
Operations/Management › Drills/Instruction
Issued 3 April 2002
Resolved
Crew failed man-overboard. Forgot to throw life-ring. One member responded for a 2 man evalution. Improper rescue breathing demonstrated.
. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 5 April 2002
Resolved 5 April 2002
Resolution: Brief training with second try and crew conducted a satisfactory recovery
Engineering › Sea-water System (primary cooling)
Issued 3 April 2002
Resolved
Replace 6 inch rubber hose connection at keel cooler inlet/outlet. Hose was worn (spongy and cracking) and clamps were rusted.
LEGACY COMPONENT DESC: Piping
Due 5 May 2002
Resolved 18 April 2002
Resolution: Replaced worn section with similar hose material and double clamped.
Construction/Loadline
Issued 25 August 1997
Resolved
PRIOR TO VSL'S NEXT REGULARLY SCHEDULED CREDIT DRYDOCK (31MAR98) OWNER TO SUBMIT A WRITTEN PROPOSAL OF ALL WORK TO BE ACCOMPLISHED DURING DRYDOCKING.
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Construction/Loadline
Issued 9 April 1997
Resolved
DRYDOCK AND MAKE PERMANENT REPAIRS TO HOLE IN FORE PEAK. TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 April 1997
Resolved 17 April 1997
Navigation
Issued 11 April 1995
Resolved
REPAIR INOPERATIVE RADAR.
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Navigation
Issued 11 April 1995
Resolved
DOUBLE NUT ALL STEERING SYSTEM JOCKEY BAR CONNECTIONS.
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Lifesaving
Issued 11 April 1995
Resolved
MAKE LIFE JACKET LOCKER DOORS LOCATED ON 02 DECK OPEN MORE EASILY, INSTALL PULL HANDLES ON DOORS.
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Construction/Loadline
Issued 11 April 1995
Resolved
REPLACE RUBBER FLEX COUPLING IN BILGE PUMP SUCTION LINE WITH REINFORCED NONCOLLAPSIBLE TYPE.
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 11 April 1995
Resolved
REPLACE EPOXY COATED PIPE NIPPLE BETWEEN STDB SEA STRAINER AND FIRE PUMP SUCTION VALVE.
Condition: Unknown
Due 11 April 1995
Resolved 12 April 1995
Documentation
Issued 12 April 1994
Resolved
Post onboard the vessel a list of all designated senior deckhands.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Engineering
Issued 12 April 1994
Resolved
Prove proper operation of porf mde alarm light on the bridge.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Construction/Loadline
Issued 12 April 1994
Resolved
Replace wasted vent pipe for #3p void.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Electrical
Issued 23 April 1986
Resolved
LABEL CIRCUITS IN ELECTRICAL POWER PANEL ON MAIN DECK AT THE FORWARD BAR.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Electrical
Issued 23 April 1986
Resolved
INSTALL COVERS ON LIGHTING ON MAIN DECK.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Engineering
Issued 23 April 1986
Resolved
INSTALL HOLDING BRACKETS ON FUEL LINES TO STBD MAIN ENGINE.
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Engineering
Issued 23 April 1986
Resolved
MAKE PERMANENT REPAIRS TO LEAK IN FUEL LINE IN OVERHEAD TO STBD MAIN ENGINE
Condition: Unknown
Due 23 April 1986
Resolved 23 April 1986
Unknown
Issued 23 April 1985
Resolved
REMOVE PVC PIPING PENETRATING AFT ENGINEROOM BULKHEAD PORT SIDE. RESTORE WATERTIGHT INTEGRITY TO AFT ENGINEROOM BULKHEAD.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Unknown
Issued 23 April 1985
Resolved
REPAIR OR REPLACE RELIEF VALVE ON SHIPS SERVICE AIR COMPRESSOR RECEIVER LOCATED IN ENGINEROOM.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985