Records from 1997 to 2001. Most recent: inspection, 20 July 2001.
Inspection history · 18
20 July 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1070029
22 August 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1391365
25 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 148897
24 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1381976
9 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 89734
9 July 2000
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421898
16 February 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1468556
7 September 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1402970
7 May 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1446790
9 December 1998
MARPOL Annex V Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 809020
22 September 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 800949
4 August 1998
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1434760
5 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1122562
25 February 1998
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1437362
4 September 1997
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1388353
26 August 1997
Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1113717
27 May 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1462599
26 May 1997
Hull Examination · Plan Review "T" Boat
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1427419
Documentation
Issued 22 August 2000
Resolved
POST COI, STABILITY LETTER, EMERGENCY BROADCAST INSTRUCTIONS, AND EMERGENCYPROCEDURES IN A LOCATION AVAILABLE TO PASSENGERS.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Fire Fighting
Issued 22 August 2000
Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 September 2000
Resolved 6 September 2000
Lifesaving
Issued 22 August 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 September 2000
Resolved 6 September 2000
Lifesaving
Issued 22 August 2000
Resolved
PROVIDE BRIDGE LOG. LOG TRAINING FOR CREW IAW 46 CFR 185.420, AND RECORD LIFESAVING EQUIPMENT MAINTENANCE IAW 46 CFR 185.702.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Construction/Loadline
Issued 9 July 2000
Resolved
MAKE PERMENENT REPAIRS YO TWO 1/2INCH "BOLT HOLES" FROM PIER BERTH, PORT SIDE AFT, 18 INCHES ABOVE WATERLINE.
Condition: Unknown
Due 9 July 2000
Resolved 9 July 2000
Construction/Loadline
Issued 9 July 2000
Resolved
CROP AND RENEW DAMAGE TO SHEAR LINE IN WAY OF PORT SIDE AMIDSHIPS. REMOVE TEMP REPAIR AND SCHEDULE INSPECTION WITH NY COAST GUARD MARINE INSPECTION OFFICE FOR APPROVAL OF PERMANENT INSERT.
Condition: Unknown
Due 9 July 2000
Resolved 9 July 2000
Lifesaving
Issued 4 August 1998
Resolved
Post life jacket donning instructions
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Fire Fighting
Issued 4 August 1998
Resolved
Provide proof of annual inspection on all portable and fixed fire extinguishers.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Accommodation/Occupational Safety
Issued 4 August 1998
Resolved
Renew starboard side portlight (window)
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Construction/Loadline
Issued 4 August 1998
Resolved
Make repairs to bilge high level alarms. Both alarms in way of engine compartments.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Documentation
Issued 4 August 1998
Resolved
Provide proof of compliance with MARPOL waste management plan.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Lifesaving
Issued 4 August 1998
Resolved
Post emergency instructions for man overboard, crossing a hazardous bar, heavy weather, and fire.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Lifesaving
Issued 4 August 1998
Resolved
Add type 2 retroreflective tape to liferings_x001C_ Missing approx 8 sq. inches per lifering on back.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Deck/Cargo
Issued 4 August 1998
Resolved
Renew diamond stay wires
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Documentation
Issued 4 August 1998
Resolved
Provide proof of the following onboard, light list, tide tables, current tables, notice to mariners, coast pilot, rules of the road, and current copies of 46 & 47CFR
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Documentation
Issued 4 August 1998
Resolved
Provide proof of deck log with drills and garbage log
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Navigation
Issued 4 August 1998
Resolved
Renew Port navigation light. (broken by passenger)
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Documentation
Issued 4 August 1998
Resolved
Provide proof of compliance with drug testinmg program. Post hot line. Post company policy. Provide proof of pre employment testing, random testing, and supervisors 60min training.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Documentation
Issued 4 August 1998
Resolved
Provide original copies of Certificate of Documentation, Certificate of Inspection, FCC Station License, and FCC Operators License
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Engineering
Issued 4 August 1998
Resolved
Provide proper flame screens (30x30 mesh) in properly sized vent - miniumumoutside diameter .75 inches in schedule 20 pipe. Vessel has installed recreational vessel .375 inch (10x10) flame screens.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Documentation
Issued 4 September 1997
Resolved
MSD PLACARD NOT POSTED NEXT TO OVBD.
Condition: Unknown
Due 18 September 1997
Resolved 22 September 1997
Construction/Loadline
Issued 4 September 1997
Resolved
STBD ENGINE ROOM HAD EXCESSIVE OILY WATER IN BILGES.
Condition: Unknown
Due 18 September 1997
Resolved 22 September 1997
Engineering
Issued 4 September 1997
Resolved
EXHAUST BLOWER MISSING HOSE EXTENSION TO BILGE
Condition: Unknown
Due 18 September 1997
Resolved 22 September 1997
Engineering
Issued 4 September 1997
Resolved
PORT THROTTLE CABLE WAS INSTALLED INCORRECTLY.
Condition: Unknown
Due 18 September 1997
Resolved 22 September 1997
Documentation
Issued 4 September 1997
Resolved
O/O DID NOT HAVE A LOG STARTED FOR HIS VESSEL.
Condition: Unknown
Due 18 September 1997
Resolved 22 September 1997
Engineering
Issued 4 September 1997
Resolved
STBD MDE SHIFT LINKAGE BROKEN DUE TO MISSING COTTER PIN, MI FOUND LINKAGE WIRED TO SHIFT ASSY.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Navigation
Issued 4 September 1997
Resolved
ALL BOLTS ARE SINGLE NUTTED AND ARE NOT NYLOC TYPE NUTS, BOLTS ARE INSTALLED UPSIDE DOWN AS WELL.
Condition: Unknown
Due 18 September 1997
Resolved 22 September 1997
Lifesaving
Issued 27 May 1997
Resolved
PROVIDE SUITABLE RESCUE LADDER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Accommodation/Occupational Safety
Issued 27 May 1997
Resolved
INSTALL SAFETY NETTING ON ALL PASSENGER RAILS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Engineering
Issued 27 May 1997
Resolved
SHORTEN FUEL SUPPLY AND RETURN HOSES TO NMT 30" IN LENGTH.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Engineering
Issued 27 May 1997
Resolved
PROVIDE FUEL TANK SPECIFICATIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Construction/Loadline
Issued 27 May 1997
Resolved
SUBMIT PLANS REVISED WITH NEW SUBCHAPTER T REQUIREMENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Fire Fighting
Issued 27 May 1997
Resolved
SERVICE/RENEW PORT ENGINEROOM HALON CYLINDER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997