Records from 1997 to 2020. Most recent: inspection, 29 April 2020.
Inspection history · 25
29 April 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6945677
5 March 2019
Internal Structural Exam · DAPI Audit · Drydock Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6637002
7 March 2018
Internal Structural Exam · Drydock Exam · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6370434
24 February 2017
Annual Inspection · DAPI Audit · Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6126525
22 February 2016
Internal Structural Exam · Drydock Exam · DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5812208
5 March 2009
Hull Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3427926
8 May 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3202001
4 April 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2904671
8 March 2006
Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2598358
11 March 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2329288
11 July 2004
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2132621
17 December 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1965455
17 November 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1948904
21 August 2003
Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1924872
4 November 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1699320
5 October 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1074508
20 October 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1366020
25 May 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 821165
13 January 2000
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 814923
21 September 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1433535
1 October 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 801758
7 August 1998
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 801760
16 February 1998
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1116622
14 January 1997
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1113402
9 January 1997
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430354
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 March 2019
Resolved
Pre-engineered fixed gas fire extinguishing systems must be installed in accordance with the manufactiurer's instructions. Captiol Duck, Lame Duck and Duck Soup did not have systems on board at time of inspection. New systems need to be examined and tested by attending marine inspector prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2019
Resolved 20 March 2019
Resolution: Received Pictures and a Fire service receipt showing the above deficiency had been corrected.
Construction/Loadline › Penetrations › Gasket
Issued 5 March 2009
Resolved
Replace all gaskets as needed for watertight compartments.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2009
Resolution: All gaskets have been replaced and/or installed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 5 March 2009
Resolved
Replace all plywood bulkheads in engine compartment with metal bulkheads.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2009
Resolution: All wood bulkheads have been replaced with thin gauge metal bulkheads.
Communications › Alarms/Indicators › Fire Alarm
Issued 8 March 2006
Resolved
Show operation of mid section vapor detector.
Due 8 March 2006
Resolved 12 March 2006
Resolution: Replaced with new.
Construction/Loadline › Penetrations › Gasket
Issued 8 March 2006
Resolved
Rplace forward restrictor plate on drive shaft.
Due 8 March 2006
Resolved 12 March 2006
Resolution: Forward restrictor plate replaced.
Engineering › Bilge Water Management System › Pump
Issued 8 March 2006
Resolved
Provide double hose clamps on Higgens pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2006
Resolved 12 March 2006
Resolution: Doubel hose clamps installed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 March 2005
Resolved
Make repairs to top step on boarding ladder.
Due 11 April 2005
Resolved 15 April 2005
Resolution: Repairs made
Lifesaving › Lifebuoys
Issued 17 December 2003
Resolved
Secure lifeline around ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2004
Resolution: Life line secure around ring buoy.
Engineering › Gasoline Engine (propulsion)
Issued 17 December 2003
Resolved
Install guards on all rotating machinery below deck.
Due 9 January 2004
Resolved 17 March 2004
Resolution: Guards installed.
Construction/Loadline › Hull
Issued 17 December 2003
Resolved
Install gasket on 12" hinged combing.
Due 9 January 2004
Resolved 17 March 2004
Resolution: Gasket installed.
Lifesaving › Embarkation Appliances/Stations
Issued 17 December 2003
Resolved
Vessel prohibited from using side curtains until proof of proper operation has been demonstrated. LEGACY COMPONENT DESC: Accessability
Action required: 705 - Other - as specified
Resolved 17 March 2004
Resolution: Proper operation of both side curtains demonstrated.
Lifesaving › Lifebuoys
Issued 17 November 2003
Resolved
Secure lifeline around body of ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2004
Resolved 19 February 2004
Resolution: listed on reinspection
Lifesaving › Embarkation Appliances/Stations
Issued 17 November 2003
Resolved
Vessel prohibitted from using side curtains until proper operation has been demonstrated. LEGACY COMPONENT DESC: Accessability
Due 9 January 2004
Resolved 19 February 2004
Engineering › Gasoline Engine (propulsion)
Issued 17 November 2003
Resolved
Install guards on all roatating machinery below deck.
Due 9 January 2004
Resolved 19 February 2004
Resolution: Captured on reinspection.
Construction/Loadline › Hull
Issued 17 November 2003
Resolved
Install gasket on 12" hinged combing.
Due 9 January 2004
Resolved 19 February 2004
Resolution: Captured on reinspection.
Documentation › Manuals/Policy Documentation
Issued 4 November 2002
Resolved
PROVIDE 46CFR PARTS 166 TO 199 FOR MASTER'S REFERENCE. LEGACY COMPONENT DESC: APPLICABLE REGULATIONS
Due 4 December 2002
Resolved 4 November 2002
Documentation › Logs/Records › Logbook (official)
Issued 4 November 2002
Resolved
Provide Traing Log for emergency drills performed.
Due 4 December 2002
Resolved 5 November 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 November 2002
Resolved
Provide 1 adult life jacket, vsl not to carry more than 27 passengers until complete.
Due 4 December 2002
Resolved 4 November 2002
Engineering › Bilge Water Management System
Issued 4 November 2002
Resolved
Prove operation of high mid bilge alarm. LEGACY COMPONENT DESC: High Water Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 November 2002
Resolved 5 November 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 4 November 2002
Resolved
Repair auto engine shut down on fixed fire system in the engine compartment. LEGACY COMPONENT DESC: Auto Shut Down
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2002
Fire Fighting
Issued 20 October 2000
Resolved
PROVIDE PROOF OF SERVICE FOR FIXED FIRE FIGHTING SYSTEM IN AFT FUEL TANK COMPARTMENT.
Condition: Unknown
Due 25 October 2000
Resolved 6 November 2000
Construction/Loadline
Issued 25 May 2000
Resolved
INSTALL SHUT OFF VALVE AT HULL PENATRATION OF KEEL COOLER AS PER 46CFR182.422.
Condition: Unknown
Due 26 June 2000
Resolved 23 August 2000
Engineering
Issued 21 September 1999
Resolved
Provide duct of rigid construction for blowers IAW 46 CFR 182.640(h).
Condition: Unknown
Due 8 October 1999
Resolved 13 October 1999
Fire Fighting
Issued 21 September 1999
Resolved
Install ventilation shutdowns for fixed fire system.
Condition: Unknown
Due 8 October 1999
Resolved 13 October 1999
Accommodation/Occupational Safety
Issued 21 September 1999
Resolved
Install rails in aft section spaced not more than 4 inches between courses.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Engineering
Issued 21 September 1999
Resolved
Hard wire fume detector to operate IAW 46 CFR 182.480 (30 seconds prior to start)
Condition: Unknown
Due 8 October 1999
Resolved 13 October 1999
Engineering
Issued 21 September 1999
Resolved
Install ventilation inter-lock for blower to run prior to engine start.
Condition: Unknown
Due 8 October 1999
Resolved 13 October 1999
Electrical
Issued 21 September 1999
Resolved
Provide proper storage for batteries.
Condition: Unknown
Due 8 October 1999
Resolved 13 October 1999
Fire Fighting
Issued 21 September 1999
Resolved
Install indicator light to show status of fixed firefighting systems.
Condition: Unknown
Due 8 October 1999
Resolved 13 October 1999
Engineering
Issued 21 September 1999
Resolved
Repair gap in exhaust piping and insulate exposed exhaust pipe.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Construction/Loadline
Issued 21 September 1999
Resolved
Label bilge level alarm lights for each compartment.
Condition: Unknown
Due 8 October 1999
Resolved 13 October 1999
Fire Fighting
Issued 1 October 1998
Resolved
Install automatic engine shutdown for fixed system.
Condition: Unknown
Due 13 October 1998
Resolved 19 October 1998
Navigation
Issued 1 October 1998
Resolved
VHF radio inoperative.
Condition: Unknown
Due 13 October 1998
Resolved 19 October 1998