Records from 1997 to 2015. Most recent: inspection, 4 December 2015.
Inspection history · 17
4 December 2015
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5772604
11 October 2014
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4999808
5 November 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3885434
21 July 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3529058
17 June 2007
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2965688
20 April 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2911424
20 April 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2911479
13 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1991943
12 January 2004
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1981993
5 February 2003
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1740046
6 April 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1601946
6 April 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1602664
11 October 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 282697
3 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 96886
30 August 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432324
25 November 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 422926
15 May 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 403707
Documentation › Logs/Records › Oil Record Book
Issued 4 December 2015
No resolution recorded
1730-Oily Water Separator. Each operation of the OWS shall be fully recorded in the ORB, so that all entries in the book approrpriate to that operation are completed. PSCO observed the recorded operation of the OWS in the ORB ran for 4 hours and processed 29.6m3 of water on 11 SEP 15, but the IOPP states the max throughput for the OWS is 5m3 per hour, which is exceeded by 9.6m3. MARPOL ANX 1/17
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2015 — due date passed with no resolution recorded
Construction/Loadline › Markings › Summer Load Line
Issued 5 November 2010
Resolved
Vessel required to have a load line mark on both sides of hull. Vessel has two load line marks on both sides of hull, unable to identify which one is being used.
ICLL 66 Annex I/ Article 13
Action required: 15 - Rectify deficiencies by next port
Resolved 8 November 2010
Resolution: Sent Class report attesting to the deficiency.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 21 July 2009
Resolved
Vessel's fire detection system and automatic alarm are not functioning. This poses a safety risk to the ship and its crew. SOLAS 1997 CHII-2/12.1.1 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 21 July 2009
Resolution: Received class report from ABS requiring the engine room to be sufficiently manned at all times until the ACONIS system can be properly repaired and tested to the satisfaction of the attending Surveyor.
Fire Fighting
Issued 15 May 1997
Resolved
PRIOR TO DEPARTURE FROM THIS PORT, PROVIDE APPROPRIATE SECTION PLAN FOR CO2SYSTEM IN CO2 ROOM TO ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997