Records from 1993 to 2025. Most recent: inspection, 12 December 2025.
Documentation record
Registered dimensions (L × B × D)56.6 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYCO SHIPBUILDERS & REPA · HOUMA, LA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 November 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 35
12 December 2025
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8299436
23 September 2025
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8239796
29 July 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8197397
18 August 2020
Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7036292
15 May 2020
TPO Audit
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6968650
16 November 2015
Industry Initiated Exam · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5764686
12 August 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4953435
15 April 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4836915
5 March 2014
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4811687
3 August 2013
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4675256
15 March 2010
MTSA Verification · Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3706459
28 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2917612
28 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2925953
17 August 2006
Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2758202
14 August 2006
MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2752479
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1976160
7 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1727017
24 July 2002
Damage Survey
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1651682
24 July 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1684290
15 July 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1652883
15 July 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1726922
20 June 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1633817
2 June 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1632692
12 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771922
9 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 191202
3 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 96886
3 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 227619
21 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 113163
25 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 53388
7 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 25845
24 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 106667
7 December 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 149054
23 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 53343
26 August 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 151564
8 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 36478
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 28 September 2020
Resolved
An exposed hazard such as rotating machinery must be protected by a cover or guard. Stern exhaust Fan did not have a cover or guard. Install cover or guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2020
Resolution: Cover replaced to satisfaction of USCG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2020
Resolved
Total relieving capacity of pressure vessel relief valve must prevent pressure form exceeding the MAWP. Starboard air receiver relief valve setting exceeded the MAWP and port air receiver was missing pressure relief valve. Install proper relief valves on air receivers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2020
Resolution: Repaired to satisfaction of USCG.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 28 September 2020
Resolved
Each towing vessel main engine must be equipped with RPM gauges at the machinery location. Furthermore, each towing vessel must have a means to monitor thrust at each operating station. RPM Gauges for port main engine were not functioning in the engine room or wheelhouse. Repair RPM Gauges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2020
Resolution: Repaired to satisfaction of USCG.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 September 2020
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid into the machinery spaces. Port generator was accumulating oil on the cylinder head. Repair oil leak and remove excess oil.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2020
Resolution: Port Generator cap/seal replaced to satisfaction of USCG.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 August 2006
Resolved
Wrong port painted on the stern.
Condition: Improper/Lack of Maintenance
Due 31 August 2006
Resolved 15 March 2010
Resolution: Correct port painted on stern.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 17 August 2006
Resolved
Fire Extinguisher in engine room missing nameplate.
Condition: Improper/Lack of Maintenance
Due 20 August 2006
Resolved 15 March 2010
Resolution: Type V fire extinguisher available for engine room.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 17 August 2006
Resolved
MSD missing type sticker
Condition: Improper/Lack of Maintenance
Due 31 August 2006
Resolved 15 March 2010
Resolution: MSD has porper sticker.