DB II is a 1966 industrial vessel. The Coast Guard has recorded 21 inspections since 1981, most recently in December 2000, along with 16 deficiencies.

Records from 1981 to 2000. Most recent: inspection, 16 December 2000.

Built
1966
Last inspected
16 December 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-45392

Inspections, by type

…with no type recorded9
Years with a record 12 calendar years (1981–2000)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it6021 - Regulatory (Subpart C or D), Gross Ton
5259 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KMA1 Freight Barge · MISLE 21283 · 16 December 2000 · activity 17762BROWN WATER XI Towing Vessel · MISLE 188179 · 16 December 2000 · activity 17762DB-1 Freight Barge · MISLE 487978 · 16 December 2000 · activity 17762

Inspection history · 21

16 December 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 17762
7 December 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 60866
4 March 1992 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 961491
9 August 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1244522
28 February 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 902436
22 May 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909631
9 January 1990 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 918140
13 March 1989 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 895661
24 February 1989 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 887909
7 December 1988 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1340584
26 September 1988 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1351997
15 September 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350007
18 August 1988 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1345236
10 July 1988 COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1030881
12 January 1987 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1008363
20 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294476
21 December 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1284123
14 December 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1284570
21 November 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1284587
28 April 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272265
2 April 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969282

Deficiency record · 16

Engineering
Issued 24 February 1989 Resolved
DEMONSTRATE PROPER OPERATION, OR SHOW WRITTEN APPROVAL FROM [name withheld], LA TO REMOVE REACH RODS AND DISABLE SEVEN (07) BILGE VALVES FORWARD OF THE COLLISION BULKHEAD (FRAME 6). 46CFR56.50-1
Condition: Unknown
Due 24 February 1989
Resolved 24 February 1989
Electrical
Issued 10 July 1988 Resolved
ON REINSTALLATION OF SHIPS SERVICE GENERATORS CONDUCT THE FOLLOWING TESTS IN THE PRESENCE OF A USCG MARINE INSPECTOR; INDEPENDENT AND PARALLEL OPERATION, ALARM CIRCUITS TESTING, SHUTDOWNS, AND SAFETIES. TEMPORARILY INSTALLED GENERATORS TO BE MAINTAINED TILL COMPLETION OF REQUIREMENT.
Condition: Unknown
Due 10 July 1988
Resolved 10 July 1988
Lifesaving
Issued 10 July 1988 Resolved
PROVIDE A SUITABLE GAS MASK OR SELF CONTAINED BREATHING APPARATUS FOR USE BY CREW IN AREA OF VESSELS REFRIGERATION EQUIPMENT BY COMPLIANCE DATE AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 10 July 1988
Resolved 10 July 1988
Engineering
Issued 10 July 1988 Resolved
PROVIDE DOCUMENTATION THAT UMSTAMPED PRESSURE VESSELS ARE ASME CODE APPROVED OR REPLACE WITH ASME CODE APPROVED PRESSURE VESSELS. ALL PRESSURE VESSELS TO HYDROED TO 1.5X MAWP IN PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 July 1988
Resolved 10 July 1988
Electrical
Issued 10 July 1988 Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY LIGHTING CIRCUIT IN FWD HYDRAULIC ROOMAND PROPERLY LABEL ALL EMERGENCY LIGHTING CIRCUITS. REPAIRS TO BE ACCOMPLISHED TO THE SATISFACTION OF THE COGNIZANT [name withheld] DATE.
Condition: Unknown
Due 10 July 1988
Resolved 10 July 1988
Accommodation/Occupational Safety
Issued 10 July 1988 Resolved
MAKE AND MAINTAIN TEMPORARY REPAIRS TO TWO(2) POTABLE WATER STORAGE TANKS UNTIL REPLACE TANKS CAN BE INSTALLED. INSTALLATION TO BE COMPLETED BY THE COMPLIANCE DATE AND TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 10 July 1988
Resolved 10 July 1988
Navigation
Issued 10 July 1988 Resolved
MAKE PERMANENT REPAIRS TO VESSELS NAVIGATION LIGHT WIRING IN ACCORDANCE WITH 46 CFR SUBCHAPTER J(ELECTRICAL REGULATIONS) TO THE SATISFACTION OF THECOGNIZANT [name withheld] DATE.
Condition: Unknown
Due 10 July 1988
Resolved 10 July 1988
Electrical
Issued 10 July 1988 Resolved
MAKE PERMANANT REPAIRS TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR THE VARIOUS MOTOR CONTROLLER LOAD CENTERS IAW 46 CFR SUBCHAPTER JREPAIRS TO INCLUDE, BUT ARE NOT LIMITED TO, PROVIDING WIRING DIAGRAMS ON INSIDE OF HINGED COVERS, PROPER LABELING, BLANKING OFF OPENINGS.
Condition: Unknown
Due 10 July 1988
Resolved 10 July 1988
Construction/Loadline
Issued 10 July 1988 Resolved
ON REINSTALLATION OF VSL'S PERMANENT GENERATORS MAKE REPAIRS TO PENETRATIONIN MAIN DECK. DECK TO BE WELDED TO 100% PENETRATION AND SUBJECTED TO NDT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 10 July 1988
Resolved 10 July 1988
Lifesaving
Issued 20 January 1986 Resolved
PROVIDE COAST GUARD SERVICED OR SERVICE ALL RAFTS AT APPROVED FACILITIES PRIOR TO 28FEB86.
Condition: Unknown
Due 20 January 1986
Resolved 20 January 1986
Engineering
Issued 20 January 1986 Resolved
BOILER NUMBER CWI76-89 HAS BEEN DISABLED, PRIOR TO OPERATING CONDUCT TEST AND INSPECTIONS AS REQUIRED BY COGNIZANT OCMI
Condition: Unknown
Due 20 January 1986
Resolved 20 January 1986
Electrical
Issued 14 December 1984 Resolved
TEST THE REVERSE CURRENT TRIPS ON THE MAIN SERVICE GENERATORS IN THE PRESENCE OF A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 December 1984
Resolved 14 December 1984
Unknown
Issued 14 December 1984 Resolved
INSTALL STORAGE BINS IN THE DECK LOCKER UNDER THE CONTROL TOWER.
Condition: Unknown
Due 14 December 1984
Resolved 14 December 1984
Electrical
Issued 14 December 1984 Resolved
TEST THE REMOTE SHUTDOWNS FOR THE VENTILATION BLOWERS IN THE PRESENCE OF AU. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 December 1984
Resolved 14 December 1984
Electrical
Issued 14 December 1984 Resolved
TEST THE OVERSPEED TRIPS ON ALL GENERATORS IN THE PRESENCE OF A U. S. COASTGUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 December 1984
Resolved 14 December 1984
Electrical
Issued 14 December 1984 Resolved
TEST THE HIGH WATER TEMPERATURE AND LOW LUBE OIL PRESSURE ALARMS ON ALL GENERATORS IN THE PRESENCE OF A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 December 1984
Resolved 14 December 1984