Records from 1997 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 66
28 April 2026
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8356197
19 March 2025
Examination of Repairs · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8095926
8 December 2024
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 8044620
17 August 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7770247
2 May 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7690070
14 August 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7533518
14 August 2022
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7533685
7 April 2022
Drydock Exam · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7428432
10 May 2021
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7193185
27 May 2020
Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6970432
11 April 2020
Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6938130
12 February 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6908167
23 January 2019
COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6614348
20 June 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6450064
12 April 2018
Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6402022
27 March 2017
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6111925
4 April 2016
Annual Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5847325
5 June 2012
Internal Structural Exam · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4335385
24 May 2012
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4320242
6 January 2012
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4219492
1 February 2011
Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3936941
28 January 2010
Deficiency Check · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3671091
19 March 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3436039
25 February 2009
Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3423392
23 February 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3433850
23 August 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3310911
23 June 2008
Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3245071
10 June 2008
DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3630783
28 April 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3193865
28 February 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3154964
16 December 2007
Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 3137257
2 November 2007
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3092860
3 October 2007
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3071568
11 September 2006
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2774637
13 June 2006
Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2678017
11 July 2005
Deficiency Check · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2421742
3 December 2004
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2252412
8 November 2004
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2236500
19 October 2004
Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2229743
8 June 2004
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2093098
5 November 2003
Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1947487
5 September 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1668080
19 August 2002
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1657149
29 July 2002
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1663085
9 May 2002
Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1614715
15 April 2002
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1604583
27 August 2001
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1072758
24 July 2001
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1370300
16 August 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 821155
17 July 2000
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365868
27 April 2000
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1369641
2 April 2000
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1047734
7 October 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 886452
9 September 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1121910
27 August 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 781349
3 August 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1365306
6 July 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1093111
16 June 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 107388
6 April 1999
Type not recorded
No type recorded · MARSEC · USCG Oceania District (CGD-O) · Activity 1512735
9 September 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 803351
27 August 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1459447
5 April 1998
Hull Examination · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 786843
17 November 1997
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1334930
10 September 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 213630
19 August 1997
Hull Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1368370
14 July 1997
Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1454467
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 August 2023
Resolved
46 CFR 176.500(a)(1): Annual inspection-Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel's annual inspection is overdue as of 24MAY2023. Annual must be completed after satisfactory dry dock for credit and prior to carrying passengers for hire to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
Resolution: Conducted COI renewal inspection, see act# 8095926.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 August 2022
Resolved
Vessels = 26ft in length have a visual & audible alarm at the operating station to indicate a high water level in each of the normally unmanned spaces. Prove operation of high water alarms in engine room compartment and aft steering to the satisfaction of the USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2022
Resolution: Proof of operational high water alarms sent via video showing light and sound at operating station for each location high water is installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2022
Resolved
Vessels = 26ft in length has been provided with individual bilge lines and bilge suctions for each watertight compartment with the exception of the space fwd of the collision bulkhead when the arrangement of the vessel is such that ordinary leakage maybe removed from this compartment by the use of a hand portable bilge pump or other equipment, & such equipment is provided. Prove operation of bilge pumps in engine room and aft steering to the satisfaction of the USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2022
Resolution: Proof of operational bilge pumps via video sent to USCG MI showing bilge pumps activated and water removed overboard from each space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2021
Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury. Repair port side dripless shaft seal continuously leaking to as original or replace with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2021
Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury. Replace wasted port side engine uptake butterfly valve with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2021
Resolved
46 CFR 183.200: Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. Replace battery cables with with exposed wires and corrosion in engine room with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021
Resolved
46 CFR 185.604(h): Each life jacket must be marked with Type I retro-reflective material approved in 46CFR164.018 or other standard specified by the commandant. Replace 23 x adult and 1 x child life-jackets with deteriorated retro-reflective tape with new and USCG approved. Remark vessel's name in block letters on all 32 life-jackets.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: All life jackets rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2020
Resolved
46 CFR 182.520(e): A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (5) The pump discharge line is suitably supported. Properly secure discharge line (hose) in forward compartmently to overboard valve. Discharge line is a ribbed aquatic hose and cannot be tightened with clamps.
Action required: 10 - Deficiency Rectified
Due 22 July 2020
Resolved 22 July 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2020
Resolved
46 CFR 177.500 (h) Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. A door, hatch or scuttle must open towards the expected direction of escape from the space served. Repair broken handle on emergency hatch cover in forward compartment to as original.
Action required: 10 - Deficiency Rectified
Due 22 July 2020
Resolved 22 July 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019
Resolved
46CFR183.340(b)(4): Replace unapproved plastic zip ties in center void with approved wire hangers every 24 inches for securing cable runs/electrical wires.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 January 2019
Resolved
46CFR177.500: Replace broken locking mechanism to as original on forward emergency hatch cover and mark inside of the space.
Action required: 705 - Other - as specified
Due 28 January 2019
Resolved 1 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019
Resolved
46CFR182.100: Replace unapproved plastic zip ties on clutch throttle controls with sea pin.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2019
Resolved
46CFR182100: Replace missing double clamp for exhaust on starboard side bank.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2019
Resolved
46CFR182.100: Replace clamp on dripless coupling with new on starboard side shaft.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019
Resolved
46CFR183.200: Remove or properly terminate dead end wires for pre-existing flood lamps on aft stbd overhead.
Action required: 705 - Other - as specified
Due 28 January 2019
Resolved 28 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 January 2019
Resolved
46CFR177.800(a): Replace unapproved tie back on forward cabin door to as original. Access door leads to space where PFDs for adults and children are stowed and access to forward washroom .
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 June 2018
Resolved
46CFR179.360: Replace wasted watertight gasket on forward port side engine room hatch cover with new to the satisfaction of the attending USCG.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 June 2018
Resolved
46 CFR 181.520: Replace missing fire extinguisher placards for each fire extinguisher with new.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2018
Resolved
46 CFR 183.340 (b)(4): Replace unapproved wire hangers with approved types every 24 inches in forward void, engine room and aft steering compartment.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 22 June 2018
Resolved
46 CFR 179.360 (a):Forward starboard emergency hatch cover to be repaired to as original and make watertight.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2018
Resolved
46 CFR 183.340 (b)(4): Electrical wires in bilge to be secured above and away from bilge using approved wire hangers.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 22 June 2018
Resolved
46 CFR 177.900: Replace starboard clip for rope guard with new. Replace missing rope guard at aft embarkation.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 22 June 2018
Resolved
46CFR185.602:(g)Replace missing placard for passengers count for upper deck.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 22 June 2018
Resolved
46CFR185.608: Mark or label fuel shut off valves with arrow showing direction to secure fuel supply system.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 March 2017
Resolved
46 CFR 164.018/IMO Res A.658(16) Annex 2 (3.1): Retro-reflective material is worn. Replace worn retro-reflective tape on personal floatation devices with new as required upon receipt of new and approved reflective tape.
Due 15 April 2017
Resolved 27 April 2017
Resolution: Verified this date. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2017
Resolved
46 CFR 183.340 (b)(4): All cable and wire must be installed with metal supports spaced not more than 24 inches apart.
Due 27 April 2017
Resolved 27 April 2017
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 May 2016
Resolved
Provide repair proposal and repair to agreed standards using fire-retardant resin on the port exhaust piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 27 March 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2012
Resolved
Wrong type battery in light, replace with right type battery. Vessel limited to daylight operations only with good visibility.
Action required: 705 - Other - as specified
Resolved 13 July 2012
Resolution: Right battery put in light as required.
Engineering › Bilge Water Management System › Interface Detector
Issued 24 May 2012
Resolved
Prove proper operation of aft indicator for auto bilge pump alarm.
Action required: 705 - Other - as specified
Due 31 May 2012
Resolved 13 July 2012
Resolution: Tested auto bilge pump alarm as required and it appears to work satisfactory.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 March 2011
Resolved
Correct outstanding/overdue def issued 01FEB11 to investigate (and make repairs) to possible exhaust leak in laz. While operating PME for <5 minutes, CO level in laz went from 0ppm to 7ppm. Submit proposal using industry standards for FRP exhaust repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 February 2011
Resolved
Investigate and repair if necessary possible exhaust leak in laz.
Ensure crew is aware of possible CO dangers.
13APR11: Temp repair to a ~4 crack in the PME exhaust ivo muffler using polyester resin allowed until fire retardant resin (per original) arrives on island with new vsl (ZUES). Make permanent repairs upon rcpt.
Due 9 December 2011
Resolved 6 January 2012
Resolution: Fire retardant resin was used to make repairs to exhaust crack in muffler as required.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 January 2010
Resolved
Repair port nav light. Correct prior to operations at night or limited visibility.
Due 14 February 2010
Resolved 28 January 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 January 2010
Resolved
Replace rotted waterlight lanyard on ringbuoy.
Due 14 February 2010
Resolved 28 January 2010
Navigation › Piloting/Steering › Marine Charts
Issued 28 January 2010
Resolved
Obtain Guam chart.
Due 14 February 2010
Resolved 28 January 2010
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 28 January 2010
Resolved
Mark vessel name on lifejackets as needed.
Due 14 February 2010
Resolved 28 January 2010
Engineering › Steering Gear System › Rudder Bearing
Issued 28 January 2010
Resolved
Make permanent repairs to leaking STBD rudder packing prior to completion of next dry-dock (Jul 2010). Crew must monitor daily until repaired.
Due 28 July 2010
Resolved 15 June 2010
Resolution: Repair made and little adjustment are to be made as needed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 February 2009
Resolved
Repair stern light and mast light.
Due 15 March 2009
Resolved 18 March 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 February 2009
Resolved
Replaced missing batteries storage cover.
Due 15 March 2009
Resolved 18 March 2009
Documentation › Certificates/Documents › FCC SSL
Issued 25 February 2009
Resolved
Resubmit FCC station license for commercial application (SB).
Due 18 March 2009
Resolved 18 March 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 February 2009
Resolved
Provide a proof of fix fire fighting servicing.
Due 15 March 2009
Resolved 18 March 2009
Engineering › Bilge Water Management System › Pump
Issued 25 February 2009
Resolved
Repair aft bilge pump.
Due 15 March 2009
Resolved 26 February 2009
Resolution: Completed satisfactory repair.
Engineering › Bilge Water Management System › Piping
Issued 25 February 2009
Resolved
Repalce all PCV value on bilge pump system.
Due 20 March 2009
Resolved 18 March 2009
Engineering › Steering Gear System › Rudder
Issued 25 February 2009
Resolved
Repair salt water leak on startboard steering packing gland.
Due 15 March 2009
Resolved 18 March 2009
Engineering › Bilge Water Management System › Pump
Issued 25 February 2009
Resolved
Supply portable hand water pump.
Due 15 March 2009
Resolved 26 February 2009
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 25 February 2009
Resolved
Repair bilge alarm indicator.
Due 15 March 2009
Resolved 18 March 2009
Construction/Loadline › Structures › Door
Issued 25 February 2009
Resolved
Reapir forward water tight door.
Due 15 March 2009
Resolved 18 March 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 23 June 2008
Resolved
Add protective guard to flywheel housing port diesel engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 28 July 2008
Engineering › Sea-water System (primary cooling) › Valve
Issued 23 June 2008
Resolved
Clean up both mde sea suction valves, sticky.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 28 July 2008
Construction/Loadline › Hull › Keel
Issued 23 June 2008
Resolved
Repair blisters water line and below, and keel damage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 23 July 2008
Resolution: Vessels reps had Barney repair all marked off blisters and repair/paint, all sat.
Construction/Loadline › Hull › Hull Plating
Issued 23 June 2008
Resolved
Install backing plate on transom steering bracket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 23 July 2008
Resolution: Vessel''s reps installed a frp backing plate for the steering ram with sat results.
Construction/Loadline › Penetrations › Weld
Issued 23 June 2008
Resolved
Repair stbd strut assmy o/b weld severe stray current damage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 23 July 2008
Resolution: Vessel reps had welder grind and renew all bad area''s of the strut assmy, with sat results.
Construction/Loadline › Penetrations › Weld
Issued 23 June 2008
Resolved
Add bonding wire to both strut assmy's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2008
Resolved 28 July 2008
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 June 2008
Resolved
EAP Requirements - 46 CFR 16.401
Discrepancies: Following items displayed: EAP, Policy/Statement, Hotline number, Supervisor received 1 hour EAP training
Due 10 July 2008
Resolved 4 May 2010
Resolution: 04MAY10
Cleared. See Activity # 3730390
Electrical › Lighting (service) › Lighting Fixture
Issued 2 October 2007
Resolved
Repair light fixtures. Forward main cabin and engine room.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 October 2007
Resolved
Remove or add junction box in engine room dead end wire.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Engineering › Steering Gear System › Rudder Bearing
Issued 2 October 2007
Resolved
Repair rudder packing starboard side, also adjust.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 2 October 2007
Resolved
Replaced anchor.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2007
Resolved 2 November 2007
Resolution: Installed new anchor.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 2 October 2007
Resolved
Emergency instructions placard for operating station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 2 November 2007
Resolution: Post emergency instruction placard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 October 2007
Resolved
All wire runs need metal hangers every 24 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 October 2007
Resolved
Repair light fixtures. Forward main cabin and engine room.
Condition: Unknown
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed Satisfactory repairs.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 October 2007
Resolved
Remove or add junction box in engine room dead end wire.
Condition: Improper Installation
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Engineering › Steering Gear System › Rudder Stock
Issued 2 October 2007
Resolved
Repair rudder packing starboard side.
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 2 October 2007
Resolved
Replace damaged anchor.
Condition: Damaged By Earlier Event
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 2 October 2007
Resolved
Missing emergency instructions placard for operating station.
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 October 2007
Resolved
All wires requires metal hangers.
Condition: Improper Installation
Due 2 November 2007
Resolved 2 November 2007
Resolution: Completed satisfactory repairs.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 11 September 2006
Resolved
Demonstrate proper operation of fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 September 2006
Resolved
Re-stencil ring buoy.
Due 25 September 2006
Resolved 13 September 2006
Fire Fighting › Fire Bucket › Stenciling
Issued 11 September 2006
Resolved
Re-stencil buckets.
Due 25 September 2006
Resolved 13 September 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 July 2005
Resolved
Re-stencil letters on ring buoy.
Due 28 July 2005
Resolved 29 July 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 July 2005
Resolved
Provide complete log book with drill sheets and EPIRB tests.
Due 28 July 2005
Resolved 29 July 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2005
Resolved
Provide complete first aid kit.
Due 28 July 2005
Resolved 29 July 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 July 2005
Resolved
Install visual indicator at operating station for auto bilge pump.
Due 28 July 2005
Resolved 29 July 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 19 October 2004
Resolved
Post an emergency broadcast placard.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 3 December 2004
Communications › Alarms/Indicators › Fire Alarm
Issued 19 October 2004
Resolved
Prove operation of audible alarm for fixed fire fighting system.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 October 2004
Resolved
Prove operation of visual indicator for fwd bilge pump.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 8 November 2004
Communications › Audible Communications › SPD (Other)
Issued 19 October 2004
Resolved
Install a public address system.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 8 November 2004
Lifesaving
Issued 5 November 2003
Resolved
Repair/replace EPIRB (broken antenna).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2003
Lifesaving
Issued 5 November 2003
Resolved
Prove operation of life ring light. Replace buoyant line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2003
Fire Fighting
Issued 5 November 2003
Resolved
Have all portable fire extinguishers and fixed fire fighting systems serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2003
Construction/Loadline
Issued 5 November 2003
Resolved
Prove operation of auto bilge floats/switches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2003
Lifesaving
Issued 5 November 2003
Resolved
Post in a conspicuous space the location of life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 November 2003
Accommodation/Occupational Safety
Issued 5 November 2003
Resolved
Conduct emergency drills (man overboard and fire).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2003
Lifesaving
Issued 5 November 2003
Resolved
Mark distress signal box/container.
Due 19 November 2003
Resolved 18 November 2003
Navigation
Issued 5 November 2003
Resolved
Place a navigation bell on board the vessel.
Due 19 November 2003
Resolved 18 November 2003
Operations/Management
Issued 5 November 2003
Resolved
Post a "Do not discharge within 3 miles of shore" placard in vicinity of sewage discharge valve.
Due 19 November 2003
Resolved 18 November 2003
Operations/Management
Issued 5 November 2003
Resolved
Have a DAPI audit conducted.
Due 19 November 2003
Resolved 5 November 2003
Documentation › Certificates/Documents
Issued 19 August 2002
Resolved
Provide valid Certificate of Documentation on board vessel.
Due 29 August 2002
Resolved 5 September 2002
Resolution: COMPLETED
Documentation › Certificates/Documents
Issued 19 August 2002
Resolved
Renew FCC Safety Radiotelephony Certificate.
Due 29 August 2002
Resolved 5 September 2002
Resolution: ON BOARD
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 15 April 2002
Resolved
Prove operation of vessel's port engine "Z-Drive" in presence of CG Marine Inspector prior to carrying passengers for hire.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2002
Resolution: Examined and witnessed operation of rebuilt transmission and found satisfactory.
Fire Fighting
Issued 24 July 2001
Resolved
Prove operation of fixed fire extinguishing system audible alarm at vessel operating station.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Lifesaving
Issued 24 July 2001
Resolved
Separate child and adult life jackets in same area, or shift number and identification placard to areas where subject life jackets or stored.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Construction/Loadline
Issued 24 July 2001
Resolved
Prove operation of aft engine space bilge pump float switch that is intermittent in operation.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Navigation
Issued 24 July 2001
Resolved
Correct the intermittent operation of compass light.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Navigation
Issued 24 July 2001
Resolved
Obtain tide tables for area(s) of operation.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Engineering
Issued 24 July 2001
Resolved
Replace missing bolt at starboard engine turbocharger to manifold flange.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Navigation
Issued 24 July 2001
Resolved
Obtain a copy of the nav rules for the vessel.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Lifesaving
Issued 24 July 2001
Resolved
Repair or replace weathered ring buoy.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Fire Fighting
Issued 24 July 2001
Resolved
Prove annual servicing of fixed fire extinguishing system and all portable fire extinguishers.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Lifesaving
Issued 24 July 2001
Resolved
Prove operation of emergency light in forward compartment.
Condition: Unknown
Due 24 July 2001
Resolved 24 July 2001
Lifesaving
Issued 17 July 2000
Resolved
Post Emergency Instruction list at operator station and on main deck.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Lifesaving
Issued 17 July 2000
Resolved
Add additional course of lifeline between upper and lower course on stern.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Navigation
Issued 17 July 2000
Resolved
Obtain navigational chart for Apra Harbor, include all updates in accordance with Notice to Mariners.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Engineering
Issued 17 July 2000
Resolved
Resecure loose brackets on fuel tank. Install cotter pins to prevent further loosening.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Fire Fighting
Issued 17 July 2000
Resolved
Obtain three fire buckets of proper capacity, appropriate lanyards and markings.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Fire Fighting
Issued 17 July 2000
Resolved
Prove annual servicing for all portable and fixed fire extinguishers. Present extinguishers are due servicing prior to the end of July 2000.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Lifesaving
Issued 17 July 2000
Resolved
Have vessel liferaft serviced prior to July 31, 2000. Liferaft is due servicing prior to July 31, 2000. Notify MSO Guam at 339-2001, extension 177, when liferaft is delivered to servicing facility.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Navigation
Issued 17 July 2000
Resolved
Obtain six smoke pyro devices to replace devices that will expire on July 31, 2000.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Engineering
Issued 9 September 1999
Resolved
ADEQUATELY SUPPORT AND BRACE FUEL TANK IAW 46 CFR 182.440(B)(3).
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Construction/Loadline
Issued 3 August 1999
Resolved
Install indicator lights at bilge pump operating station to indicate bilge pump(s) operation.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Lifesaving
Issued 3 August 1999
Resolved
Stow child sized life jackets seperate from adult sized life jackets, and provide proper marking in new location.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Lifesaving
Issued 3 August 1999
Resolved
Properly fill out and post vessel Emergency Broadcast Instructions.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Lifesaving
Issued 3 August 1999
Resolved
Provide vessel with two portable lights (flashlights), one for helm, one for engine space.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Construction/Loadline
Issued 3 August 1999
Resolved
Obtain portable bilge pump with sufficient length of hose to enable any space on vessel to be pumped over the side.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Construction/Loadline
Issued 3 August 1999
Resolved
Prove operation of steering compartment bilge high level alarm.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Engineering
Issued 3 August 1999
Resolved
Submit proposal for repair of fuel tank supports that have fractured.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Lifesaving
Issued 3 August 1999
Resolved
Replace hydrostatic release on EPIRB due two years usage. EPIRB hydrostaticreleases are good two years from installation in unit.
Condition: Unknown
Due 3 August 1999
Resolved 3 August 1999
Engineering
Issued 6 July 1999
Resolved
Provide acceptible repair proposal to modify fuel tank support brackets. Any modification and/or repair must be acceptable to Coast Guard Marine Inspector. Vessel operator to monitor all tank supportsuntil scheduled drydocking of vessel on 03AUG99.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Fire Fighting
Issued 27 August 1998
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Documentation
Issued 27 August 1998
Resolved
OBTAIN FCC STATION LICENSE
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Lifesaving
Issued 19 August 1997
Resolved
Attach Coast Guard approved lights to lifejackets. Until these lights areattached, vessel operational route shall be limited to not more than twenty(20) miles from a Harbor of Safe Refuge.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Accommodation/Occupational Safety
Issued 19 August 1997
Resolved
Write up and post, a Waste Management Plan, that complies with 33CFR 151.57
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Navigation
Issued 19 August 1997
Resolved
Prove operation of magnetic compass light.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Lifesaving
Issued 19 August 1997
Resolved
Post instructions for inflatable life raft in immediate area of life raft.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Fire Fighting
Issued 19 August 1997
Resolved
Refill engine space FE-241 fixed fire extinguishing system cylinder. Untilsuch time that the extinguisher is refilled, the vessel shall carry one (1)extra B-II sized portable fire extinguisher.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Engineering
Issued 19 August 1997
Resolved
Provide MSO Guam with drawing for proposed protective machinery guard to beplaced over engine to v-drive housing shaft.
Condition: Unknown
Due 19 August 1997
Resolved 19 August 1997
Navigation
Issued 14 July 1997
Resolved
POST MAGNETIC COMPASS DEVIATION TABLE AT HELM.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Documentation
Issued 14 July 1997
Resolved
PROVIDE PROOF OF COMPLIANCE WITH DRUG TESTING REQUIREMENTS AS PER 46 CFR PART 16.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Engineering
Issued 14 July 1997
Resolved
PRIOR TO VESSEL CARRYING PASSENGERS, COMPLETE AFTER INSTALLATION TEST ON FUEL TANK SYSTEM AS PER 46 CFR 182.440(c)(2).
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Documentation
Issued 14 July 1997
Resolved
PRIOR TO VESSEL OPERATING IN GUAM, ENSURE OPERATIONAL ROUTE IS ASSIGNED/APPROVED BY [name withheld].
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Navigation
Issued 14 July 1997
Resolved
PROVE PROPER OPERATION OF VESSEL'S INSTALLED DEPTH SOUNDER.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Lifesaving
Issued 14 July 1997
Resolved
PROVIDE A 406 MHZ EPIRB FOR VESSEL TO OPERATE MORE THAN 3 (THREE) MILES_x001C_ FROM SHORE WITH PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Lifesaving
Issued 14 July 1997
Resolved
PROVIDE ADEQUATE FIRST AID KIT ON VESSEL AS PER 46 CFR 184.710
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Lifesaving
Issued 14 July 1997
Resolved
LABEL NAME OF VESSEL ON ALL LIFE PRESERVERS AND LIFE RING BUOY AS PER 46 CFR 185.604(b) AND INSTALL RETRO REFLECTIVE TAPE ON LIFE RING BUOY.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Lifesaving
Issued 14 July 1997
Resolved
PROPERLY MARK CHILD SIZE LIFE PRESERVER STORAGE AREA AS PER 46 CFR 185.604 (f).
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Navigation
Issued 14 July 1997
Resolved
PROVIDE NAVIGATION CHARTS, TIDE, AND CURRENT TABLES FOR AREA OF OPERATION AS PER 46 CFR 184.420.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Unknown
Issued 14 July 1997
Resolved
POST EMERGENCY OPERATING PROCEDURES, EMERGENCY RADIO BROADCAST PLACARD, LIFEJACKET DONNING PLACARDS, MARPOL POLLUTION PLACARD AND WASTE MANAGEMENT PLAN PRIOR TO OPERATION.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Documentation
Issued 14 July 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Documentation
Issued 14 July 1997
Resolved
PROVIDE ALL FCC REQUIRED LICENSES, PERMITS, AND CERTIFICATES AS PER 47 CFR PART 80, PRIOR TO OPERATING VESSEL MORE THAN 1000 FT FROM SHORE.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Fire Fighting
Issued 14 July 1997
Resolved
PROPERLY RECONNECT MANUAL OPERATION CABLE TO THE FIXED FIRE EXTINGUISHER INENGINE ROOM AFTER DELIVERY OF VESSEL TO GUAM.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997