Records from 2008 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 17
28 April 2026
Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8356197
19 March 2025
Examination of Repairs · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8095926
8 December 2024
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 8044620
17 August 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7770247
2 May 2023
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7690070
14 August 2022
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7533518
14 August 2022
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7533685
7 April 2022
Drydock Exam · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7428432
10 May 2021
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7193185
27 May 2020
Annual Inspection · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6970432
11 April 2020
Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6938130
12 February 2020
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6908167
23 January 2019
COI Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6614348
20 June 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6450064
12 April 2018
Drydock Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6402022
27 March 2017
Annual Inspection · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6111925
4 April 2016
Annual Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5847325
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 August 2023
Resolved
46 CFR 176.500(a)(1): Annual inspection-Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel's annual inspection is overdue as of 24MAY2023. Annual must be completed after satisfactory dry dock for credit and prior to carrying passengers for hire to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2025
Resolution: Conducted COI renewal inspection, see act# 8095926.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 August 2022
Resolved
Vessels = 26ft in length have a visual & audible alarm at the operating station to indicate a high water level in each of the normally unmanned spaces. Prove operation of high water alarms in engine room compartment and aft steering to the satisfaction of the USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2022
Resolution: Proof of operational high water alarms sent via video showing light and sound at operating station for each location high water is installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 August 2022
Resolved
Vessels = 26ft in length has been provided with individual bilge lines and bilge suctions for each watertight compartment with the exception of the space fwd of the collision bulkhead when the arrangement of the vessel is such that ordinary leakage maybe removed from this compartment by the use of a hand portable bilge pump or other equipment, & such equipment is provided. Prove operation of bilge pumps in engine room and aft steering to the satisfaction of the USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2022
Resolution: Proof of operational bilge pumps via video sent to USCG MI showing bilge pumps activated and water removed overboard from each space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2021
Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury. Repair port side dripless shaft seal continuously leaking to as original or replace with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2021
Resolved
46 CFR 182.100: All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure and personnel injury. Replace wasted port side engine uptake butterfly valve with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2021
Resolved
46 CFR 183.200: Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. Replace battery cables with with exposed wires and corrosion in engine room with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021
Resolved
46 CFR 185.604(h): Each life jacket must be marked with Type I retro-reflective material approved in 46CFR164.018 or other standard specified by the commandant. Replace 23 x adult and 1 x child life-jackets with deteriorated retro-reflective tape with new and USCG approved. Remark vessel's name in block letters on all 32 life-jackets.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2021
Resolution: All life jackets rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2020
Resolved
46 CFR 182.520(e): A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (5) The pump discharge line is suitably supported. Properly secure discharge line (hose) in forward compartmently to overboard valve. Discharge line is a ribbed aquatic hose and cannot be tightened with clamps.
Action required: 10 - Deficiency Rectified
Due 22 July 2020
Resolved 22 July 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 July 2020
Resolved
46 CFR 177.500 (h) Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. A door, hatch or scuttle must open towards the expected direction of escape from the space served. Repair broken handle on emergency hatch cover in forward compartment to as original.
Action required: 10 - Deficiency Rectified
Due 22 July 2020
Resolved 22 July 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019
Resolved
46CFR183.340(b)(4): Replace unapproved plastic zip ties in center void with approved wire hangers every 24 inches for securing cable runs/electrical wires.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 January 2019
Resolved
46CFR177.500: Replace broken locking mechanism to as original on forward emergency hatch cover and mark inside of the space.
Action required: 705 - Other - as specified
Due 28 January 2019
Resolved 1 March 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019
Resolved
46CFR182.100: Replace unapproved plastic zip ties on clutch throttle controls with sea pin.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2019
Resolved
46CFR182100: Replace missing double clamp for exhaust on starboard side bank.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 January 2019
Resolved
46CFR182.100: Replace clamp on dripless coupling with new on starboard side shaft.
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019
Resolved
46CFR183.200: Remove or properly terminate dead end wires for pre-existing flood lamps on aft stbd overhead.
Action required: 705 - Other - as specified
Due 28 January 2019
Resolved 28 January 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 January 2019
Resolved
46CFR177.800(a): Replace unapproved tie back on forward cabin door to as original. Access door leads to space where PFDs for adults and children are stowed and access to forward washroom .
Action required: 10 - Deficiency Rectified
Resolved 23 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 June 2018
Resolved
46CFR179.360: Replace wasted watertight gasket on forward port side engine room hatch cover with new to the satisfaction of the attending USCG.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 June 2018
Resolved
46 CFR 181.520: Replace missing fire extinguisher placards for each fire extinguisher with new.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 June 2018
Resolved
46 CFR 183.340 (b)(4): Replace unapproved wire hangers with approved types every 24 inches in forward void, engine room and aft steering compartment.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 22 June 2018
Resolved
46 CFR 179.360 (a):Forward starboard emergency hatch cover to be repaired to as original and make watertight.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 June 2018
Resolved
46 CFR 183.340 (b)(4): Electrical wires in bilge to be secured above and away from bilge using approved wire hangers.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 22 June 2018
Resolved
46 CFR 177.900: Replace starboard clip for rope guard with new. Replace missing rope guard at aft embarkation.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 22 June 2018
Resolved
46CFR185.602:(g)Replace missing placard for passengers count for upper deck.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 22 June 2018
Resolved
46CFR185.608: Mark or label fuel shut off valves with arrow showing direction to secure fuel supply system.
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 6 July 2018
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 March 2017
Resolved
46 CFR 164.018/IMO Res A.658(16) Annex 2 (3.1): Retro-reflective material is worn. Replace worn retro-reflective tape on personal floatation devices with new as required upon receipt of new and approved reflective tape.
Due 15 April 2017
Resolved 27 April 2017
Resolution: Verified this date. All sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2017
Resolved
46 CFR 183.340 (b)(4): All cable and wire must be installed with metal supports spaced not more than 24 inches apart.
Due 27 April 2017
Resolved 27 April 2017
Construction/Loadline › Penetrations › Pipe Flange
Issued 2 May 2016
Resolved
Provide repair proposal and repair to agreed standards using fire-retardant resin on the port exhaust piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2016
Resolved 27 March 2017