Records from 1997 to 2024. Most recent: inspection, 17 January 2024.
Inspection history · 91
17 January 2024
Deficiency Check · PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7841755
10 April 2023
PSC A · COC-CVE Initial
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7665960
21 January 2022
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7383754
8 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6937109
2 April 2020
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6934453
30 March 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6933374
22 January 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6894113
6 December 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6868669
20 November 2019
ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6856224
8 April 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6664311
15 February 2019
COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6617401
10 February 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6630437
3 February 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6620927
7 January 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6609234
16 December 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6600310
22 August 2018
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6519813
18 July 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6505584
18 July 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6519520
16 February 2018
ISPS II Exam · COC-CVE Quarterly
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6353544
8 January 2018
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6333902
24 December 2017
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6328600
17 December 2017
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6325615
2 August 2017
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6223641
28 January 2017
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6074057
13 January 2017
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6068637
23 September 2016
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6006512
24 August 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5986198
16 August 2016
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5974009
18 July 2016
Ballast Water Examination · ISPS II Exam · COC-CVE Initial
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5945038
10 January 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4233240
30 December 2011
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4217762
24 December 2011
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4214508
26 February 2011
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3956599
2 February 2011
NPV Safety Exam · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3957801
26 December 2010
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3916207
29 November 2010
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3899450
28 September 2010
NPV Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3859990
20 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3853575
15 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3851425
10 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3847001
1 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3844247
14 March 2010
NPV Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3696088
4 January 2010
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3658434
16 December 2009
ISPS II Exam · Ballast Water Examination · COC-CVE Annual · MARPOL Annex V Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3650777
13 May 2009
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3473786
13 May 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3474096
5 January 2009
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3388627
23 December 2008
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3384454
20 November 2008
STCW 95 Exam · ISPS I Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3366997
24 February 2005
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2298644
18 February 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2295421
14 February 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2292254
14 February 2005
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2302607
12 February 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2291230
12 December 2004
ISPS II Exam · MARPOL Annex V Examination · COC-CVE Annual · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2256112
22 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2246154
20 October 2004
ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2224510
30 September 2004
ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2209650
24 September 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2219414
6 June 2004
MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex V Examination · Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2089870
30 May 2004
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2082539
4 May 2004
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2058801
23 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2029768
20 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2010055
3 February 2004
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1999364
3 December 2003
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1958038
19 September 2003
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1908492
28 May 2003
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1803873
27 May 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1804512
9 December 2002
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1716308
13 September 2002
MARPOL Annex I Examination · MARPOL Annex V Examination · Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1675053
2 July 2002
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1639884
11 June 2002
Security Inspection · Deficiency Check
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1629433
17 May 2002
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1618011
15 May 2002
Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1681947
10 May 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1615493
6 December 2001
Control Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 772705
25 April 2001
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376564
11 April 2000
Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1404949
5 April 2000
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361387
5 April 2000
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361388
21 December 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 436019
6 December 1999
MARPOL Annex I Examination · Control Verification · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436304
26 April 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1390993
20 January 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 424723
20 January 1999
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1029881
13 December 1998
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378527
24 April 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 789481
5 December 1997
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436018
10 October 1997
Type not recorded
No type recorded · Activities Europe · Activity 778921
7 April 1997
Type not recorded
No type recorded · Activities Europe · Activity 1102271
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 January 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway
enclosures shall be self-closing and shall have an
approximately uniform rate of closure of no more than 40s
and no less than 10s. PSCO observed FSD B.015, B.018,
B.616 in FWD crew accommodation stairway on B deck,
MVZ FSD A.003, A.039, A.052, A.059 on A deck, FSD 1.037
on deck 1, FSD 2.052 on deck 2, FSD 4.006 fwd on deck 4,
and FSD 6.031, 6.014, and 6.06 all closing at a rate faster
than 10s.
07105 / 74 SOLAS 97 II-2/30.4.1 / 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 January 2024
Resolution: See DNV Class Report and Master's Declaration in Documents.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 January 2024
Resolved
The marking must enable passengers to identify all the
routes of escape and readily identify escape exits. All
escape route signs and fire equipment location markings
shall be of photoluminescent material or marked by lighting.
PSCO observed that the Theater on deck 4 had inadequate
escape route signage.
07120 / 74 SOLAS 97 II-2/28.1.10 / 10c
Action required: 10 - Deficiency Rectified
Resolved 17 January 2024
Resolution: Installed adequate escape route signage in Theater.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 17 January 2024
Resolved
Muster and embarkation stations shall be adequately
illuminated by lighting supplied from the emergency source
of electrical power required by regulation II-I/42 or II-1/43.
One embarkation light was extinguished on the starboard
side in between lifeboats #11 and #13.
11124 / 74 SOLAS 97 III/11.4 / 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 January 2024
Resolution: Replaced embarkation light in between lifeboat #11 and #13.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 17 January 2024
Resolved
Before the ship leaves port and at all times during the voyage,
all life-saving appliances shall be in working order and ready
for immediate use. Lifeboat # 5 failed to start, rendering it not
ready for immediate use.
11129 / 74 SOLAS 20 III/20.2 / 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 January 2024
Resolution: Replaced battery in the #5 lifeboat and completed operational check.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 April 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in good working order and ready for immediate use. The vessel could not secure the engine on lifeboat number 4.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 April 2023
Resolution: Vessel provided satisfactory Class Report attesting to proper operation of lifeboat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 April 2023
Resolved
The Administration may require that all reasonable and practicable measures shall be taken to limit the entry and spread of water above the bulkhead deck. PSCO observed missing dogs on 02 weathertight hatches on port side mooring station deck 03.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 10 April 2023
Resolution: Vessel rectified prior to the end of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 April 2023
Resolved
Each hose specified in this chapter as "fire hoses" shall, together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections. PSCO observed spanner wrench missing at the following stations: 1.31 and 2.23.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 10 April 2023
Resolution: Vessel provided spanner wrenches before the end of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 April 2023
Resolved
The hull, superstructures, structural bulkheads, decks, and deckhouses shall be constructed of steel or equivalent material. PSCO discovered bolts missing on A Class boundary covers in following locations: outside cabin 7004 and outside cabin 6130.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 10 April 2023
Resolution: Vessel provided bolts before the end of the exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 November 2019
Resolved
The doors shall be self-closing and capable of closing... and shall have an approximately uniform rate of closure. Doors in decks 2 and 3 and spa area were closing in less than 10 seconds.
74 SOLAS (97) II-2/30.4.1; 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2019
Resolved 3 December 2019
Resolution: Ship sent in documentation on 03DEC19 of deficiencies being rectified, class report sent in on 06DEC19.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2019
Resolved
The... piping systems and fitting shall be of a construction adequate for the service for which they are intended. A/C piping on "A" deck technical locker and H/T piping in incinerator room had significant leaks.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2019
Resolved 6 December 2019
Resolution: Class submitted report that leaking pipes were cropped and renewed, submitted on 06DEC19.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 15 February 2019
Resolved
Ever crew member with assigned duties shall be familiar with these duties before the voyage begins. Multiple boat crews lacked familiarity with their assigned emergency duties during abandon ship drill. 74 SOLAS (2014) III/2.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2019
Resolved 15 February 2019
Resolution: MSD St Thomas received and reviewed class report, Vsl has been cleared to proceed with their scheduled voyage.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 February 2019
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fir to proceed to sea without danger to ship or persons onboard. Tender safety equipment certificate indicates tender boats are required to carry 105 adult lifejackets. Tender boat #9 has 88 adult lifejackets on board. 74 SOLAS (2014) I/11
Action required: 705 - Other - as specified
Due 3 March 2019
Resolved 7 March 2019
Resolution: Received Class Report from Vessel
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 15 February 2019
Resolved
The company and the ship shall comply with the requirements of the ISM Code. The company should establish procedures to ensure that ships maintain and ensure that inspections are held at appropriate levels and records are maintained. No tender boat lifejacket checklist were available for October and November 2018 as required per safety management system. Lifejacket checklist for January 2018 indicates full compliance however PSCO on tender boat #9 discovered tender is missing 17% of adult lifejackets. 74 SOLAS (2014) IX/3.1 - ISM Code Reg 10 - 16ac
Action required: 705 - Other - as specified
Due 3 March 2019
Resolved 7 March 2019
Resolution: Received Class Report from Vessel
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 August 2018
Resolved
11101- Lifeboat- At all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. While lowering & testing port side lifeboats, the #4 lifeboat would not start.
74 SOLAS (14) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 25 August 2018
Resolved 25 August 2018
Resolution: Vessel's engineering department identified and repaired issue. Lifeboat was lowered and tested.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 8 January 2018
Resolved
ANOA not 24 hours in advance.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2018
Resolved 8 January 2018
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 August 2017
Resolved
Hold back hooks not subject to central control station release are prohibited. Door leading into the security office was found held open with a block of wood.
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: Block of wood was removed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 2 August 2017
Resolved
The marking must enable passengers to identify all the routes of escape and readily indentify the escape exits. Secondary emergency escape door exit sign is blocked by a curtain.
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: Vessel's crew provided an additional sign and posted it.
Electrical › Electrical Distribution System (service) › Cable
Issued 2 August 2017
Resolved
All electrical apparatus's shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. 02 compartments have dead ended wires, electrical locker 9.05 and steward station L.
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: Vessel's crew tapped and applied heat-shrink to wires.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 August 2017
Resolved
The doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure, and shall have an approximately uniform rate of closure of no more than 45s and no less than 10s with the ship in the upright position. The following doors are not operating properly; A.035, 8.015, 2.028, 1.054, 2.029, A.073, and A.070.
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: Corrections and adjustments were made to all doors.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 August 2017
Resolved
In all ships general arrangement plans shall be permanently exhibited for the guidance of the ship's officers, showing clearly each fire extinguishing appliance. Actuator for the deep fat fryer fire suppression system on deck 04 stbd in not marked IAW the fire control plan.
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: Vessels' crew provided sign and posted.
Fire Fighting › Means of Escape › Corridors
Issued 2 August 2017
Resolved
A corridor, lobby, or part of a corridor from which there is only one route of escape shall be prohibited. Officer desk/computer were found in storage space adjoining garbage sorting room with no means to indicate emergency or escape.
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: Desk and computer were removed.
Personnel › Training › Passenger Safety
Issued 13 January 2017
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Forward passenger stairwell guides are unfamiliar with assigned duties during passenger evacuation during the abandon ship drill.
Action required: 705 - Other - as specified
Resolved 13 January 2017
Operations/Management › Drills/Instruction › Fire
Issued 13 January 2017
Resolved
Drills shall, as far as practical, be conducted as if there were an actual emergency. During fire drill initiation action regarding securing of accomodation passenger staterooms were not conducted.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2017
Resolution: Vessel submitted class report in form of Audit rectifying the deficiency.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 13 January 2017
Resolved
Except in the vicinity of the rudder and propeller, a buoyant lifeline shall be becketed around the outside of the lifeboat. On multiple lifeboats the buoyant lifeline was not becketed to the outside of teh lifeboat.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2017
Resolution: Vessel's agent submitted documentation attesting to the rectification of the deficiency.
Construction/Loadline › Structures › Door
Issued 13 January 2017
Resolved
Fire Doors in main vertical zone bulkheads and stairways shall be self closing. Fire Door 2.058 is unable to close fully.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2017
Resolution: Vessel's agent submitted documentation attesting to the rectification of the deficiency.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 13 January 2017
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire damper FX/VSOC302/1 (purifier room) is unable to operate remotely from the navigation bridge.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2017
Resolution: Vessel's agent submitted documentation attesting to the rectification of the deficiency.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 13 January 2017
Resolved
Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: The vessel failed to fully implement the requirements of the ISM code through their SMS procedures as evident by the following identified deficiencies. These deficiencies taken with the remaining material deficiencies discovered are evidence that the ship and or company......Recommend external audit
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2017
Resolution: Audit was conducted and submitted to the Coast Guard. Will be scanned into this activity.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 13 January 2017
Resolved
01) ISM Code Part A Reg 10.2.4 see narrative for description
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2017
Resolution: Vessel submitted audit report.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 13 January 2017
Resolved
02) ISM Code Part A Reg 3.3 see narrative for description
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2017
Resolution: Vessel submitted audit report.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 January 2017
Resolved
03) ISM Code Part A 2.2 see narrative for description
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 January 2017
Resolution: Vessel submitted audit report.
Fire Fighting › Means of Escape › Blocked
Issued 24 August 2016
Resolved
0960 - PSCO found a storeroom (locker 4.10) that was converted into an office space for the sous chef on the port side of the galley creating an arragement where occupants of the office space are not provided with direct means to an acceptable means of escape. 74SOLAS(97)II-2/28.1 50ac
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 23 September 2016
Resolution: Class ammended galley office on fireplan and a smoke detector and alarm inside the space werer installed affording an equivelent level of safety for escape purposes IAW MSC guidelines Procedure Number 25.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 24 August 2016
Resolved
0920 - Fire control plans shall be kept up to date, any alterations being recorded thereon as soon as practieable. Locker 4.10 in the galley is being used as an office space, but is still listed on the fire control plan as a storage locker. 74SOLAS(97)II-2/20.1 50ac
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 23 September 2016
Resolution: Class ammended galley office on fireplan and a smoke detector and alarm inside the space werer installed affording an equivelent level of safety for escape purposes IAW MSC guidelines Procedure Number 25.
Stability › Watertight Integrity › General
Issued 20 July 2016
Resolved
1284 - Cargo ports and other similar openings in the sides of ships below the freeboard deck shall be fitted with doors so designed as to ensure water tightness and structural integrity commensurate with the surrounding shell plating. The side shell doors in bunkering stations port and STBD (12 and 13) were observed leaking water. 40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 August 2016
Resolution: Vessel repaired doors to Class satisfaction.
Fire Fighting › Means of Escape › Doorways
Issued 20 July 2016
Resolved
0915 - Additional aids for escape shall be provided as necessary to ensure accessibility, clear marking and adequate design for emergency situations. Primary and secondary escape routes were not marked in the auxiliary generator room. 10c
Condition: Design Flaw
Due 20 July 2016
Resolved 20 July 2016
Resolution: Corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 20 July 2016
Resolved
0960 - Where the contents and use of a space are such that there is doubt as to the classification, it shall be treated as a space within the relevant category, having the most stringent boundary requirement. Storage locker 4.10 in the main galley is a category 12 space. PSCO observed desks and chairs and the space was being used as a workspace. 40a
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 September 2016
Resolution: Class ammended galley office on fireplan and a smoke detector and alarm inside the space werer installed affording an equivelent level of safety for escape purposes IAW MSC guidelines Procedure Number 25.
Fire Fighting › Means of Escape › Stairways
Issued 20 July 2016
Resolved
0960 - Furniture in the stairway enclosures shall be limited to fixed seating. Numerous wheelchairs were observed in multiple stairway enclosures. 40c
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 September 2016
Resolution: no wheelchairs were observed in the stairway enclosures.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 20 July 2016
Resolved
0750 - Fire doors in main vertical zone bulkheads and stairway enclosures shall be self closing and shall have an approximate uniform rate of closure of no more than 40 seconds and no less than 10 seconds. Multiple doors observed either not fully closing or closing in less than 10 seconds. 10c
Condition: Design Flaw
Due 20 July 2016
Resolved 20 July 2016
Resolution: Corrected on the spot.
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 November 2010
Resolved
Gray Water Line in Fuel Oil Purifier Room Need to be properly repaired in accordance with Reg. 22 of ICLL(2005cons.)
ICLL(2005cons.) Reg. 22 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 December 2010
Resolved 22 December 2010
Resolution: Recieved copy of Class Report for specified repairs and survey.
Lifesaving › Lifeboat › Hull
Issued 28 September 2010
Resolved
Fractures at STBD entryway at base and along inside seam.
Condition: Damaged By Earlier Event
Due 28 October 2010
Resolved 24 October 2010
Lifesaving › Lifeboat › Hull
Issued 14 March 2010
Resolved
Tender boat #10's hull integrity compromised along keel and stbd engine inop.
Action required: 705 - Other - as specified
Due 12 April 2010
Resolved 16 March 2010
Resolution: 1.repair to the hull using fiberglass and resin
2.remove debris from clogged fuel lines
Lifesaving › Lifeboat › Hull
Issued 14 March 2010
Resolved
Tender boat #7's hull integrity compromised in way of keel.
Action required: 705 - Other - as specified
Due 12 April 2010
Resolved 16 March 2010
Resolution: Repaired hull using fiberglass and resin
Fire Fighting › Means of Escape › Blocked
Issued 16 December 2009
Resolved
multiple escape routes are obstructed and blocked by misc. equipment throughout vessel; passenger and crew corridors, crew stairwells. Solas 74 (2004) II-2/Reg 13.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2009
Resolved 16 December 2009
Resolution: vessel removed misc. equipment from egress routes.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 December 2009
Resolved
vessel has updated fire control plans but does not have them posted throughout vessel.
Action required: 15 - Rectify deficiencies by next port
Resolved 4 January 2010
Resolution: Conducted thorough check throughout cruise ship, all fire control plans had been updated and posted as required.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 January 2009
Resolved
Several variances were identified during SFP plan review that need correction - Make the necessary modifications to arrive at a final solution of a revised accurate drawing which represents the shipboard situation with both (plans and ship) in compliance with SOLAS and re-submit for examination to Lloyds Register and subsequently the USCG MSC.
Action required: 705 - Other - as specified
Due 5 February 2009
Resolved 13 May 2009
Resolution: SFP plan corrected to satisfaction of the attending Coasy Guad Marine Inspector.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 December 2008
Resolved
Vessel SFP was not flag approved. Lloyds onboard to verify 8 page comment list on SFP. Verify all items identified in 8 page punch list as well as items outlined in MSC letter H2-0803755 dated 23DEC08. Submit RO approved SFP to MSC for review.
Action required: 15 - Rectify deficiencies by next port
Due 23 December 2008
Resolved 5 January 2009
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 19 November 2008
Resolved
Vsl FCP, SFP & EEP were found not to indicate the actual situation on board the vessel. Several areas of the vsl were found to have been modified since last plan review. Vsl plans were found not to reflect modifications. No evidence was produced fo Flag approval for mods. Require all plans be updated to reflect actual condition on vsl. (See attached Form B for complete deficiency narrative)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 December 2008
Resolved 23 December 2008
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 19 November 2008
Resolved
Identified deck locker deck 3, fr 268-272 (cl), to be loaded with flammables while not being in constructed as per II-2/9. Compartment lacks smoke detection required by II-2/7.5.2. Remove all stores from locker and secure space until space is made to comply with requirements of II-2/9 and II-2/7.5.2. Provide RO report on modifications of space to reflect full compliance under SOLAS.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 December 2008
Resolved 23 December 2008
Fire Fighting › Means of Escape
Issued 3 December 2003
Resolved
Photoluminescent tape is ineffective in several areas along escape routes. Renew tape according to last test report. Provide flag state report attesting to the proper repair of photoluminescent tape throughout vessel. Provide test results of new tape installed with area tested. LEGACY COMPONENT DESC: Emergency Lighting
Due 31 May 2004
Resolved 6 June 2004
Resolution: Verified as corrected this date
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 17 May 2002
Resolved
Cabinet containing fixed CO2 bottles for main propulsion motors not able to be locked as indicated by opreating instructions. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2002
Resolved 11 June 2002
Resolution: Cabinets (02) fitted with locks as per mfg specifications.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 17 May 2002
Resolved
Trash and other miscellaneous ships equipment stowed in fire lockers, technical lockers, and a/c spaces where these items should not be stowed. LEGACY COMPONENT DESC: Technical Lockers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 24 May 2002
Resolution: Verified as repaired by attending Marine Inspector.
Fire Fighting › Structural - A Class Divisions
Issued 17 May 2002
Resolved
Computer room fire door tied back and not in service. Restore to proper service. LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2002
Resolved 29 June 2002
Resolution: Fire door satisfactorily repaired.
Electrical › Electric Supply System (service)
Issued 17 May 2002
Resolved
Circuits overloaded in outlets behind main stage prep area. Remove overloads. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 24 May 2002
Resolution: Verified as repaired by attending Marine Inspector.
Operations/Management › Vessel Safety Management
Issued 17 May 2002
Resolved
Remove lint from main motors and dryers in main laundry. LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 24 May 2002
Resolution: Verified as repaired by attending Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 May 2002
Resolved
Gates missing at provisions elevator next to vegetable prep room. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 24 May 2002
Resolution: Verified as repaired by attending Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 May 2002
Resolved
Eye wash station and emergency exit in main laundry blocked, unblock them. LEGACY COMPONENT DESC: Eye Wash station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 24 May 2002
Resolution: Verified as repaired by attending Marine Inspector.
Fire Fighting
Issued 25 April 2001
Resolved
FSD #5.042 And 5.47 would not close properly, locking into place and excessive delay in closing. Crew corrected on-the-spot.
Condition: Unknown
Due 25 April 2001
Resolved 26 April 2001
Construction/Loadline
Issued 5 April 2000
Resolved
Complete temporary repairs to internal structural damage in way of starboard frames 262-276, Dolphin and Main decks, in accordance with HONMS-approved Lloyd's repair proposal prior to arrival to Los Angeles. USCG LOSMS and Lloyd's to inspect temporary repairs upon arrival. ICLL 66.
Condition: Unknown
Due 5 April 2000
Resolved 5 April 2000
Documentation
Issued 5 April 2000
Resolved
Submit to USCG HONMS, a certificate of seaworthiness from flag state (NL) prior to departing the Hawaiian Islands.
Condition: Unknown
Due 6 April 2000
Resolved 10 April 2000
Construction/Loadline
Issued 5 April 2000
Resolved
Complete permanent repairs to internal structural damage in way of starboard frames 262-276, Dolphin and Main decks, during DEC 2000 drydocking to satisfaction of USCG and Class Society. ICLL 66.
Condition: Unknown
Due 5 April 2000
Resolved 5 April 2000
Fire Fighting
Issued 26 April 1999
Resolved
Prior to next US port, make fire station door "B.06" latching mechanism operational.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Lifesaving
Issued 26 April 1999
Resolved
Prior to next US port, provide signage for child lifejacket stowage on embarkation decks.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Unknown
Issued 26 April 1999
Resolved
No later than next US port, remove combustibles from fire stations and emergency escape routes on crew decks.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Documentation
Issued 26 April 1999
Resolved
Prior to next CVQ or July 26, 1999, provide Flag State report to USCG addressing "B" class cabin doors on Navigation deck that are fitted with magnetic hold backs. SOLAS 74, II-2/31.1.2 does not permit this.
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Fire Fighting
Issued 13 December 1998
Resolved
SHIP SHALL REPAIR OR REPLACE THE IONIZATION DETECTOR LOCATED IN THE OXYGEN STORAGE ROOM OUTSIDE THE HOSPITAL
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998
Lifesaving
Issued 13 December 1998
Resolved
SHIP SHALL DEMONSTRATE THE DEPLOYMENT OF THEIR TRAINING LIFERAFT FOR THE USCG INSPECTORS IAW MOC LETTER 4-98
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998
Fire Fighting
Issued 13 December 1998
Resolved
SHIP SHALL REPAIR FSD # 7.012 BY INSTALLING A FILTER IN HYDRAULIC LINES & SHIP SHALL PROVIDE A DEDICATED OPERATOR TRAINED IN OVERRIDING THE FSD CONTROLS DURING ALL EMERGENCIES AND DRILLS UNTILL THE DOOR IS REPAIRED
Condition: Unknown
Due 13 December 1998
Resolved 13 December 1998