Records from 2016 to 2025. Most recent: inspection, 8 December 2025.
Inspection history · 48
8 December 2025
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8279375
14 December 2024
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8047091
19 December 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7840811
28 November 2023
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7830819
27 October 2023
Administrative Inspection · In-Service Inspection
Physical examination · Cruise Ship National Center of Expertise · Activity 7818531
28 July 2023
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7758571
26 May 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7695630
11 May 2023
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7690276
1 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7678724
13 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7621203
29 November 2022
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7600771
22 October 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7584312
17 October 2022
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7578628
12 August 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7531639
5 August 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7525289
5 August 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7531628
30 July 2022
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7563717
22 July 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7516766
22 July 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7516836
16 July 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7522784
17 June 2022
Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7479025
10 June 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7473580
28 May 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7466159
21 December 2021
PSC B · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7370894
5 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935563
3 February 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6901378
9 December 2019
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6870495
29 October 2019
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6841110
8 April 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6664311
4 November 2018
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6570459
11 October 2018
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6559513
1 August 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6563987
26 June 2018
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6464635
1 May 2018
Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6403347
10 November 2017
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6303157
26 September 2017
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6289042
23 August 2017
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6249619
18 August 2017
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6248924
4 August 2017
In-Service Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6230647
14 May 2017
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6146530
9 May 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam · COC-CVE Quarterly
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6131560
10 March 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6102595
6 March 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6099764
20 January 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6073831
17 November 2016
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6042797
7 August 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5965153
3 July 2016
Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5928147
17 May 2016
COC-CVE Quarterly · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5879834
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 December 2025
Resolved
Spaces are classified according to their fire risk as shown in categories (1) to (14). A/C machinery space on deck 04, MVZ 06 is a category (10) space where storage of combustibles is prohibited. PSCO observed storage of cardboard boxes and pallets within this space.
74 SOLAS (20) II-2/9.2.2.3.2.2
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 December 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 December 2025
Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed medical equipment (stretcher and wheelchair) obstructing escape route corridor within the medical center and another obstructed escape route within the Lecturer Room on deck 5.
74 SOLAS (20) II-2/13.1.2
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 December 2025
Resolved
Fire doors in main vertical zone bulkheads, galley boundarise and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degreees opposing closure. FSD 05-3-035 did not close and latch
74 SOLAS (20) II-2/9.4.1.1.5.1
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 December 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 December 2025
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries, and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. FSD 04-5-049 closed faster than 10s.
74 SOLAS 20 II-2/9.4.1.1.5.2
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 December 2025
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 November 2023
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be etablished by the company. The technical and/or operational nature of the deficiencies 02 and 03 provide objective evidence of a serious failure of the implementation of the ISM Code specific to the lifesaving appliances (lifejackets/lifebuoys). A plan for conducting an external audit report specific to lifesaving maintenance shall be submitted to the OCMI prior to clearance of this deficiency.
74 SOLAS (20) IX/3.1
ISM Code A.10.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2023
Resolved 19 December 2023
Resolution: Sector Miami received letter from Lloyds Register providing a plan to conduct the required audit. Code 17 chanded to code 50.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 November 2023
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection. PSCOs observed 03 lifebuoys on deck 13 near the running track which had frayed and excessively worn grablines as well as deteriorated retroreflective tape.
74 SOLAS 20 III/34 LSA Code 1.2.2.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2023
Resolution: Sec Miami received report from class attesting to the replacement of the lifebuoys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 November 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO’s observed approximately 30 lifejackets that were excessively worn and/or torn. PSCOs directed crew to conduct thorough examination of all lifejackets in all outside lockers and in lifeboats. Crew found/removed ~250 lifejackets in total.
74 SOLAS 20 III/20.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 November 2023
Resolution: Sec Miami received report from class stating that the vessel removed the worn lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 November 2023
Resolved
Not less than on half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights, not less than two of these shall also be provided with lifebuoy self-activating smoke signals and be capable of quick release from the navigation bridge. PSCOs observed that the port side lifebuoy on the navigation bridge lacks the ability to be quick released.
74 SOLAS 20 III/7.1.3
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2023
Resolved 19 December 2023
Resolution: Received documentation attesting to the rectification of the quick release of the lfe buoy. Please see documents tab for additional info.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 13 January 2023
Resolved
THE ADMINISTRATION OF A PARTY MAY ALLOW ANY FITTING, MATERIAL, APPLIANCE OR APPARATUS TO BE FITTED IN A SHIP OR OTHER PROCEDURES, ALTERNATIVE FUEL OILS, OR COMPLIANCE METHODS USED AS AN ALTERNATIVE TO THAT REQUIRED BY THE ANNEX IF SUCH FITTING, MATERIAL, APPLIANCE OR APPARATUS OR OTHER PROCEDURES, ALTERNATIVE FUEL OILS, OR COMPLIANCE METHODS ARE AT LEAST AS EFFECTIVE IN TERMS OF EMISSIONS REDUCTIONS AS THAT REQUIRED BY THIS ANNEX, INCLUDING ANY OF THE STANDARDS SET FORTH IN REGULATION 13 AND 14. VESSEL REPORTED INOPERABLE EXHAUST GAS CLEANING SYSTEM (EGCS) WHILE IN EMISSION CONTROL AREA FOR A PERIOD OF APPROXIMATELY TWO HOURS.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2023
Resolution: Vessel provided evidence sufficient, compliant fuel was onboard and the cause of the EGCS failure was due to operational error, not system failure.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 December 2021
Resolved
The purpose of this regulation is to suppress and swiftly extinguish a fire in the space of origin, except for the following functional requirements shall be met: fire-extinguishing appliances shall be readily available. PSCOs observed the deluge system on the aft mooring station, deck 5, had sprinkler heads which were blocked with debris in the nozzle.
SOLAS 20 II-2/10.1.1.2
Action required: 10 - Deficiency Rectified
Due 21 December 2021
Resolved 21 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 December 2021
Resolved
The construction of doors and door frames in "A" class divisions, with the means of seucring them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated, this being determined in accordance with the Fire Test Procedures Code. PSCOs observed doors "A" class divisions which do not close as designed.
SOLAS 20 II-2/9.4.1.1.2
Action required: 10 - Deficiency Rectified
Due 21 December 2021
Resolved 21 December 2021
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 29 October 2019
Resolved
04104 - Low level lighting - In addition to the emergency lighting required by regulations II-1/42 and III/11.5, the means of escape including the stairways, and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. PSCOs observed low location lighting that was blocked in a escape route by a penny meachine on deck 7, stair case 40 starboard side. 74SOLAS(2009 Cons)II-2/13.3.2.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 October 2019
Resolution: Penny machine blocking low location lighting was moved, deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 29 October 2019
Resolved
11124 - Embarkation arrnagement - Alleyways, stairways and exits giving access to the muster and embarkation station shall be lighted. Several lights indicated as emergency lights were not operational on Deck 6 in the magnums champagne and wine bar. 74 SOLAS (2014 Cons) III/11
Action required: 10 - Deficiency Rectified
Resolved 29 October 2019
Resolution: Emergency lights were replaced and PSCOs observed them to be operational, deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 October 2019
Resolved
07105 - Fire doors - Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and which are normally locked shall satisfy the following requirements: the doors shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees; PSCO witnessed the following fire doors not close appropriately; 04-7-103, 04-7-144, and 06-3-117. 74 SOLAS (2009 Cons) II-2/9
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 9 December 2019
Resolution: Received Class report verifying the repairs for the fire doors.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 October 2019
Resolved
07120 - Means of escape - The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck: escape routes shall be maintained in a safe condition and free of obstacles. PSCO observed chairs and tables blocking a primary means of escape exiting the Corona Cigar Club. 74 SOLAS (2009 Cons) II-2/13
Action required: 10 - Deficiency Rectified
Resolved 29 October 2019
Resolution: Items blocking primary means of escape were removed, deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 October 2019
Resolved
07105 - Fire doors - Fire doors in main vertical zone bulk heads, galley boundaries and stairway enclosures other than power-operated watertight doors and which are normally locked shall satisfy the following requirements: the approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of movement. PSCOs witnessed the following fire doors close in less than 10s; 04-3-044, 04-3-050, 04-7-095, 04-7-103, 04-7-144, 05-2-010, 05-2-083, 05-3-025, 05-7-069, 05-7-071, 05-7-073, 05-7-075, and 06-4-055. 74 SOLAS (2009 Cons) II-2/9
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 9 December 2019
Resolution: Received class report verifying fire doors have been repaired.
Engineering › Fuel Oil Service System › Valve
Issued 10 November 2017
Resolved
1-0750-THE TERMINATIONS OF SOUNDING PIPES SHALL BE FITTED WITH SELF CLOSING BLANKING DEVICES AND WITH A SMALL DIAMETER SELF CLOSING CONTROL COCK LOCATED BELOW THE BLANKING DEVICE FOR THE PURPOSE OF ASCERTAINING BEFORE THE BLANKING DEVICE IS OPENED THAT OIL FUEL IS NOT PRESENT. PSCO OBSERVED MAJORITY OF SMALL DIAMETER RELIEF VALVES OF SOUNDING TUBES IN MACHINERY SPACE MISSING. - SOLAS 74 II-2/4.2.2.3.5.1.3 - 50A
Action required: 705 - Other - as specified
Due 10 December 2017
Resolved 14 November 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 4 August 2017
Resolved
The transitional source of emergency electrical power required by paragraph 3.1.3 shall consist of an accumulator battery so arranged as to supply automatically in the event of failure of either the main or emergency source of electrical power at least the services specified in II-1/42.4.1. The vessel's uninterruptible power supply is inoperable.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 5 August 2017
Resolution: Class survey reports manufacturer's representative service technician attended on board to carry out repairs. Repairs is considered pemanent and in order.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 17 November 2016
Resolved
A fixed fire detection and fire alarm system shall be so installed and arranged as to provide smoke detection in service spaces, control stations and accomodation spaces. Smoke detector 05.02.06.030 was found inoperable. 74 SOLAS (14) CH. II-2/7.5.2
Action required: 705 - Other - as specified
Resolved 17 November 2016
Resolution: Smoke detector replaced during inspection and found operating.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 17 November 2016
Resolved
Fire doors in main vertical boundaries shall be self closing. Fire doors 05-7-075 and 08-5-65 did not close properly. 74 SOLAS (14) CH. II-2/9.4.1.1.5.1
Action required: 705 - Other - as specified
Resolved 17 November 2016
Resolution: Doors adjusted to properly self-close.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 May 2016
Resolved
Found receptacles (trash cans) in the prep-area for room service, recreational area outside smoking room, & crew/officer break room with receptacles missing metal lids & several plastic combustible material trash cans. Non-compliance with SOLAS.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2016
Resolved 17 May 2016
Resolution: All receptacles corrected on spot, sat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 17 May 2016
Resolved
During a walk through spaces, Card Room area two egress corner doors block by added table & chairs which were hindrance to escape in an emergency.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2016
Resolved 17 May 2016
Resolution: Hotel/housekeeping staff removed on spot, sat.; and will check again if permanently moved.
Operations/Management › Vessel Activity › Construction/Repair
Issued 17 May 2016
Resolved
During a general walk through spaces, materials in boxes for the scrubbers installation e.g. cables was observed tied down for sea in the passageway to be unloaded in Seattle. There is a possible hindrance to muster stations egress in an emergency. Informed Master of the condition. SECTOR Juneau will follow up next week's vessel port of call in Juneau.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 May 2016
Resolved 17 May 2016
Resolution: Scheduled visit on 24 may 2016 in Juneau to verify boxes unloaded.