Records from 2009 to 2026. Most recent: inspection, 29 April 2026.
Documentation record
Registered dimensions (L × B × D)238.7 ft × 64.5 ft × 23.5 ft
Registered tonnagegross 2,724 / net 1,403
ITC dimensions (L × B × D)Not recorded
ITC tonnagegross 2,724 / net 1,403
BuilderUS BARGE LLC · PORTLAND, OR, UNITED STATES · built 2009
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 February 2026 · expires 31 March 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2724 - Convention (Subpart B), Gross Ton
1403 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
29 April 2026
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8309561
6 May 2025
MARPOL Annex VI Survey · MARPOL Annex I Examination · Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8076468
2 May 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7895583
8 April 2024
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7892773
27 March 2024
Drydock Extension · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7884571
3 April 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7635224
1 March 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7397363
6 May 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7190972
27 May 2020
MTSA/ISPS Verification · Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6919245
28 June 2019
MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6726819
25 April 2019
Drydock Exam · Administrative Inspection · Cargo Tank Internal · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6669777
11 February 2019
Internal Structural Exam · Drydock Extension · Administrative Inspection · Annual Inspection · Cargo Tank Internal
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6611261
19 April 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6360687
29 January 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6345844
1 March 2017
COI Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6083590
12 August 2016
Deficiency Check · Periodic Inspection · MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5970545
10 June 2015
Annual Inspection · MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5113474
3 March 2014
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4809091
4 June 2013
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4579502
7 July 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4370979
27 May 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4324087
8 May 2012
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4304779
14 June 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4051305
20 December 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3913844
18 May 2010
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3858198
17 May 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3740361
4 April 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3709944
10 August 2009
In-Service Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3561477
19 May 2009
Construction Oversight · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3478825
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 May 2025
Resolved
A fixed cargo piping system shall be installed on a tank vessel carrying Grade A, B, or C cargo. The piping shall be arranged so as to avoid excessive stresses at the joints. For sizes exceeding 2 inches in diameter, flanged, welded, or other approved types of joints shall be employed. Packing material shall be suitable for the cargo carried. Connections at bulkheads shall be made so that the plating does not form part of a flanged joint. Piping may be carried through bunker spaces and deep tanks provided it is run through a pipe tunnel. The tunnel may be omitted where the pipe is extra heavy, all joints are welded, and bends are installed to provide for expansion and contraction. MI observed threads weeping cargo from the port side cargo pump piping priming line. 46 CFR 32.50-15 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2025
Resolved 7 May 2025
Resolution: Priming line fitting has been re-tightened.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 11 February 2019
Resolved
Missing non-rising stem valve indicators. Replace all non-rising stem valve indicators throught the barge.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2019
Resolution: Replaced all missing indicators.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 February 2019
Resolved
Port and Starboard nav light were obstructed by railing. Ensure port and starboard nav light are unobstructed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2019
Resolved 15 February 2019
Resolution: Moved nav light to the outside of the hand rails. Lights are unobstructed.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 12 August 2016
Resolved
Generator had excessive oil on windings. Clean oil residue off of the windings to the satisfaction of attending CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 3 October 2016
Resolution: See Narrative.
Engineering › Diesel Engine (auxiliary) › Charge Air Cooling
Issued 12 August 2016
Resolved
Remove excessive oil around radiator on both prime movers to the satisfaction of attending CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 3 October 2016
Resolution: See Narrative.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 June 2015
Resolved
Replace expired battery for lifebuoy waterlight.
Action required: 705 - Other - as specified
Resolved 10 June 2015
Resolution: corrected on the spot.
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 8 May 2012
Resolved
Provide EIAPPs on all machinery >130 kW.
Due 8 June 2012
Resolved 11 May 2012
Resolution: EIAPPs provided.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 17 May 2010
Resolved
Valve position indicators on tanks 1P, 4S, and 4P are missing/inoperable. Vsl required to replace valve position indicators IAW 46 CFR 56.20-9.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2010
Resolved 18 May 2010
Resolution: Repairs completed to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 May 2010
Resolved
Annual service not conducted for portable fire extinguishers. Vsl is required to provide annual servicing certificate for extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2010
Resolved 18 May 2010
Resolution: Sector Seattle received servicing certificate for extinguishers.