Records from 2016 to 2025. Most recent: inspection, 27 October 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 76
27 October 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8259428
23 May 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8145067
16 May 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8172323
9 May 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8172311
2 May 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8127325
25 April 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8127314
18 April 2025
COC-CVE Annual · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8112715
18 April 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8113830
11 April 2025
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8110049
2 December 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8042821
19 October 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8020121
9 May 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7930126
6 May 2024
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7907794
2 May 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7924171
24 April 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7921804
22 April 2024
PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7898426
2 February 2024
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7874011
3 October 2023
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7802846
25 September 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7796636
13 July 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7834027
6 July 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7813039
15 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7796135
1 June 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7757482
11 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7739058
4 May 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7730157
29 April 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7730122
9 April 2023
PSC A · COC-CVE Annual · Ballast Water Examination · ISPS Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7663421
4 January 2023
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616427
30 December 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7614647
28 November 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7600902
26 October 2022
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7584393
19 October 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7580672
13 October 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7576847
5 October 2022
COC-CVE Quarterly · PSC B · ISPS Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7571613
24 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542667
9 August 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529251
21 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7483446
16 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7479727
14 June 2022
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7477641
10 April 2022
Ballast Water Examination · PSC B · COC-CVE Annual
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7426118
7 May 2021
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7195792
13 May 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6952806
23 March 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6930787
17 March 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6928030
15 March 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6928716
22 January 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6894154
13 December 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6873488
14 November 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6856042
31 October 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6846659
25 October 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6842452
2 October 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6826853
26 September 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6821988
5 September 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6804721
26 August 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6795618
7 August 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6783330
5 August 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6773687
15 July 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6752566
14 May 2019
Ballast Water Examination · COC-CVE Annual · ISPS III Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6681515
26 May 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6424316
18 May 2018
Ballast Water Examination · COC-CVE Annual · ISPS III Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6415950
29 September 2017
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6281598
7 September 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6262542
21 August 2017
MARPOL Annex IV Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6248753
19 July 2017
COC-CVE Annual · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6214233
15 May 2017
MARPOL Annex I Examination
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6146894
13 March 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6204769
5 February 2017
COC-CVE Quarterly
Type not classified · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6083286
10 September 2016
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5993884
30 July 2016
MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5958824
28 July 2016
ISPS II Exam · COC-CVE Annual · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5955764
19 July 2016
Damage Survey · Special
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5946443
1 July 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5952936
1 July 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5953699
25 June 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5918752
3 May 2016
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5869901
7 February 2016
COC-CVE Quarterly · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5810325
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 October 2025
Resolved
Passenger ships carrying more than 36 passengers shall be equipped with an automatic spriknler of an approved type complying with the requirements of the Fire Safety Systems Code in all control stations, accomodation and service spaces, including corridors and stairways. In the garbage cold room, one ampule for the high pressure water mist system was a color of a higher temperature rating than the rest of the ampules.
74 SOLAS (2020) II-2/10.6.1.1
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 October 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 October 2024
Resolved
07105-Windows facing life-saving appliances, embarkation and assembly stations, external stairs and open decks used for escape routes, and windows situated below liferaft and escape slide embarkation areas shall have fire integrity as required in table 9.1. PSCO observed numerous window seals on embarkation deck degraded not meeting fire rating standards. Windows that were observed were on the starboard side. 74 SOLAS 20-II-2/9.4.1.3.3
50a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2024
Resolved 2 December 2024
Resolution: Received class report attesting to repairs
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 October 2024
Resolved
07123-A red light shall indicate a door is fully open and a green light shall indicate a door is fully closed. PSCO observed the following FSDS: 1.5.016, 2.2.004, 2.5.046, 3.4.028, 3.4.024, 3.7.082, 3.7.057, 4.2.004, 4.3.032, 4.3.035, 4.4.076, 4.5.084, 4.7.095, 5.2,008, 5.7.086, 5.7.069, 5.7.095, 6.4.044, 6.4.050, 6.5.070, 6.5.081, 6.7.094, 7.5.053, 8.3.036, 8.6.074, 8.6.079, 9.3.018, 9.6.069, 9.7.061, 10.7.055, 11.4.085, 12.2.003, 12.2.007, 12.4.021, 12.5.051, 12.6.044, 12.7.067, 13.5.016, 14.5.006, were indicating open on the bridge, verified doors at locations as closed. 74 SOLAS 20-II-2/13.8.2 50a
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2024
Resolved 2 December 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 22 April 2024
Resolved
Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions, shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO's observed
missing insulation over scrubbers in the incinerator control
room.
74 SOLAS 04 II-2/14.2.1.1.1
40 c
Code 07123
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 May 2024
Resolution: Provided class report, showing deficiency resolution
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 April 2024
Resolved
Spaces are classified according to their fire risk as shown in categories (1) to (14). A/C machinery space AC 3-05, a category (10) space where storage of combustibles is prohibited. PSCO observed storage of cardboard boxes within the AC space.
74 SOLAS 04 II-2/9.2.2.3.2.2
Code 07101
40 c
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 May 2024
Resolution: Provided class report, showing resolution of deficiency
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 April 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCO's observed the following doors closing in less than 10s: FSD-06-05-64, FSD-06-5-073, FSD-06-4,053, FSD-06-2-012, FSD-12-06-055, FSD-11-6-041.
74 SOLAS 04 II-2/9.4.1.1.4.2
40 c
Code 07105
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 May 2024
Resolution: Provided class report, showing resolution of deficiency
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO's found incinerator's refractor wasted to the trash chute, with 12in of paint burnt off the surface indicating the firebox failing to contain the heat of the incinerator.
74 SOLAS 04 I/11(a)
10 c
Code 07199
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 22 April 2024
Resolution: Received a DNV [name withheld] indicating that repair will be completed on May 13th, 2024. See attached document. In the meantime the incinerator will not be used.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 September 2023
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. PSCOs observed fire doors FSD 12.5.036, FSD 05.7.076, and FSD 05.7.078 closing in less than 10 seconds. 74 SOLAS 20 II-2/9.4.1.1.5.2 (16ac) Code 07105.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2023
Resolved 3 October 2023
Resolution: The defective fire door closing mechanism rectified by ship staff, operation of fire
doors FSD 12.5.036, FSD 05.7.076 and FSD 05.7.078 verified and found in order. See attached survey statement.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 5 October 2022
Resolved
Table 9.1 shall apply to bulkheads not bounding either main vertical zones or horizontal zones. Table 9.2 shall apply to decks not forming steps in main vertical zones nor bounding horizontal zones. PSCOs observed missing insulation in fire station FST-11-7-42 that abutted a passenger stairtower. SOLAS 04 II-2/9.2.2.3.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2022
Resolved 19 October 2022
Resolution: Received Class Report attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2022
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCOs observed an escess of wires and extension cords underneath the gallery desk in vicinity of FSD 07-5-057. SOLAS 04 II-1/40.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 October 2022
Resolution: Received Class Report attesting to repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 5 October 2022
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All items of lifeboat equipment shall be secured within the lifeboat by lashings, storage in lockers or compartments, storage in brackets or similar mounting arrangements or other suitable means. PSCO observed water provisions throughout the lifeboats were not secured or stored as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 October 2022
Resolution: Received Class Report issuing a Condition of Class regarding lifeboat provision storage with a due date of 17JAN23.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 5 October 2022
Resolved
On-board training in the use of the ship's life-saving appliances, including survival craft equipment, and in the use of the ship's fire-extinguishing appliances shall be given as soon as possible but not later than two weeks after a crew member joins the ship. PSCOs observed crew members who were unfamiliar with the use of "new" seasickness medicine that had been onboard since March 2022.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 October 2022
Resolution: Received documentation demonstrating Class acceptance of training regarding seasickness medication.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 October 2022
Resolved
Crew members shall receive instruction on fire safety on board the ship. While PSCOs were walking around they observed evidence of crew members smoking in crew cabin 3741. Additionally, PSCOs observed a heat lamp in crew cabin 4228.
Action required: 10 - Deficiency Rectified
Resolved 9 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 May 2019
Resolved
Lifeboat #18 unable for immediate start due to clogged fuel filter. The fuel filter was replaced and lifeboat is in working order. Class onboard during exam.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 May 2019
Resolved 14 May 2019
Resolution: Replace clogged fuel filter
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 May 2019
Resolved
Class "A" door FSD 01-5-013 for passage from compartment 14 in the engine room to the incinerator room is damaged and unable to prevent passage of smoke. Class onboard during exam.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 14 May 2019
Resolved 14 May 2019
Resolution: fixed door
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 May 2019
Resolved
Public address system is unable to be heard above the ambient noise in arcade room. Class onboard during exam.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 14 May 2019
Resolved 14 May 2019
Resolution: Volume adjusted on PA system
Fire Fighting › Means of Escape › Doorways
Issued 29 July 2017
Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release and shall not be equipped with any locking device that prevents release of the latch when pressure is applied to the device. Decorative door in Cagny Dining Room, Modeno Dining Room, and sauna are fit with locks. 74 SOLAS (04) II-2/13.3.2.6.2. 16(a)(c).
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 2 August 2017
Resolution: Door locks removed and covered with plate in Cagneys, Moderno and Spa.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 29 July 2017
Resolved
Compressed gas cylinders must always be secured and when not in use stowed in a rack. Approximately 12 bottles stowed in engineering compartment 10 and 01 bottle in engineering workshop secured by synthetic rope. 46 CFR 147.60(b)(1). 16(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 31 July 2017
Resolution: Properly stowed compressed gas cylinders.
Personnel › Training › Familiarization Training
Issued 29 July 2017
Resolved
Crew shall be trained to be familiar with the operation of fire fighting systems. Crew members (cooks) in all galleys did not know location of galley ventilation shut downs. 74 SOLAS (04) II-2/15.2.2.1. 10(c).
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 29 July 2017
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 29 July 2017
Resolved
There shall be installed in accomodation spaces a fixed fire detection system to detect fire. Heat detector in men's sauna was inoperable. 74 SOLAS (04) II-1/7.5.3.1. 10(c).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 July 2017
Resolved 29 July 2017