Records from 1997 to 2004. Most recent: inspection, 18 November 2004.
Inspection history · 25
18 November 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2243721
17 October 2004
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2223581
5 October 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1996809
12 April 2004
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2042643
9 March 2004
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2021948
11 August 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1866300
8 July 2003
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1833075
16 March 2003
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1793975
6 February 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1739402
23 December 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1721694
27 August 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1664844
16 August 2002
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1662364
8 May 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1492267
18 December 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1477046
4 September 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1407007
26 July 2001
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1391651
5 June 2001
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1066643
17 July 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1462871
6 December 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 813335
1 October 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352932
16 September 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1365371
31 July 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1109199
3 September 1998
Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1468025
12 December 1997
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1414893
18 July 1997
Initial Construction-Excluding Oversight · Hull Examination · Inclining Experiment · Plan Review "T" Boat · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 776134
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 October 2004
Resolved
Provide a placard with the max passenger amount for second deck IWO aft ladder.
Condition: Improper/Lack of Maintenance
Due 12 October 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VSL
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 October 2004
Resolved
Prior to night time operation, repair stern light.
Condition: Improper/Lack of Maintenance
Due 5 October 2004
Resolved 5 October 2004
Lifesaving › Lifefloat › Serviceable
Issued 5 October 2004
Resolved
Replace or repair 03 L/F's as discussed.
Condition: Improper/Lack of Maintenance
Due 5 November 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VESSEL
Lifesaving › Lifefloat › Lifeline
Issued 5 October 2004
Resolved
Replace tag lines on all L/F's as needed.
Condition: Improper/Lack of Maintenance
Due 5 November 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VSL
Construction/Loadline › Penetrations › Flange Pad
Issued 5 October 2004
Resolved
Reseal cleat backing plates in store room and fuel oil room.
Condition: Improper Installation
Due 12 October 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VSL
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 October 2004
Resolved
Provide a support beam or repair 2nd deck overhead.
Condition: Improper/Lack of Maintenance
Due 12 October 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOST OF VSL.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 October 2004
Resolved
Prior to the carriage of passengers, repair water leak from STBD engine, outboard, and PORT engine inboard water cooled exhaust pipe.
Condition: Improper/Lack of Maintenance
Due 5 October 2004
Resolved 5 October 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 October 2004
Resolved
Repair and properly mount engine battery switches.
Condition: Placed in Improper Service
Due 12 October 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOST OF VSL
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 October 2004
Resolved
Provide safety shields for both PORT and STBD PTO's.
Condition: Improper/Lack of Maintenance
Due 12 October 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VSL
Electrical › Lighting (service) › Lighting Fixture
Issued 5 October 2004
Resolved
Provide a light cover for light in E/R.
Condition: Improper/Lack of Maintenance
Due 12 October 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VSL
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 October 2004
Resolved
Label life preserver location with the size and amount.
Condition: Improper/Lack of Maintenance
Due 12 October 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VSL
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 5 October 2004
Resolved
Remove all child (16total) life preservers, w/labels from vessel. Vsl COI states no children allowed. Vsl rep will remove.
Condition: Improper/Lack of Maintenance
Due 12 October 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VSL
Engineering › Bilge Water Management System › Strainer
Issued 5 October 2004
Resolved
Provide strainers for bilge pick-up lines as per 46CFR182.25.5(b).
Condition: Improper/Lack of Maintenance
Due 5 November 2004
Resolved 17 October 2004
Resolution: CLEARED DUE TO TOTAL LOSS OF VSL
Electrical › Electric Supply System (service) › Cable
Issued 5 October 2004
Resolved
Secure wires and remove dead-ended wires as needed throughout vessel.
Condition: Improper/Lack of Maintenance
Due 5 November 2004
Resolved 17 October 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 August 2003
Resolved
PROPERLY LABEL LIFEJACKET STOWAGE AREA. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 18 August 2003
Resolved 21 August 2003
Resolution: SAT
Lifesaving › Buoyant Apparatus
Issued 11 August 2003
Resolved
PROPERLY STENCIL VESSEL NAME AND PASSENGER CAPACITY ON LIFEFLOATS. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Due 18 August 2003
Resolved 21 August 2003
Resolution: SAT
Electrical › Electrical Distribution System (service)
Issued 11 August 2003
Resolved
REMOVE ALL DEAD END WIRING THROUGHOUT ENGINE ROOM. LEGACY COMPONENT DESC: Wiring
Due 11 September 2003
Resolved 21 August 2003
Resolution: SAT
Engineering › Fuel Oil Storage/Transfer System
Issued 11 August 2003
Resolved
REPLACE LIQUID LEVEL INDICATING GAUGES WITH HEAT RESISTANT MATERIAL AND INSTALL IAW 46 CFR 182.20-25 9 (a)(5). LEGACY COMPONENT DESC: Gauge
Condition: Improper Installation
Due 11 September 2003
Resolved 9 March 2004
Resolution: WITNESSED INSTALLATION.
Fire Fighting › Fixed Fire Detection System
Issued 11 August 2003
Resolved
PROVIDE 3RD PARTY INSPECTION REPORT ATTESTING TO THE PROPER OPERATION OF HEAT DETECTOR IN ENGINE ROOM. LEGACY COMPONENT DESC: Heat Detectors
Due 18 August 2003
Resolved 21 August 2003
Resolution: PHONCON W/MIKE FROM SUNCOAST FIRE.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 11 August 2003
Resolved
PROVIDE 3RD PARTY CO2 INSPECTION REPORT. LEGACY COMPONENT DESC: Inspection
Due 18 August 2003
Resolved 21 August 2003
Resolution: REPORT PROVIDED.
Lifesaving › Lifejacket/PFD (General)
Issued 27 August 2002
Resolved
Rename all life preservers to match vessel name.
Due 27 September 2002
Resolved 6 February 2003
Resolution: SAT
Fire Fighting › Fixed Fire Detection System
Issued 27 August 2002
Resolved
Demonstrate the proper operation of the fire and smoke protection system.
Due 4 September 2002
Resolved 13 February 2003
Resolution: 3RD PARTY REPORT.
Engineering
Issued 27 August 2002
Resolved
Demonstrate the proper operation of the installed bilge suction system. LEGACY COMPONENT DESC: Bilge system
Due 4 September 2002
Resolved 6 February 2003
Resolution: SAT
Engineering › Diesel Engine (propulsion-electric)
Issued 27 August 2002
Resolved
Repair exhaust and oil leak on PORT GENSET.
Due 27 September 2002
Resolved 6 February 2003
Resolution: SAT
Documentation › Certificates/Documents
Issued 27 August 2002
Resolved
Provide an FCC Safety Certificate. LEGACY COMPONENT DESC: FCC SSL
Due 27 September 2002
Resolved 6 February 2003
Resolution: SAT
Pollution Prevention/Response
Issued 27 August 2002
Resolved
Clean oil from bilge water. LEGACY COMPONENT DESC: Oil in bilge
Due 28 August 2002
Resolved 6 February 2003
Resolution: SAT
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 August 2002
Resolved
Replace first-aid kit.
Due 4 September 2002
Resolved 6 February 2003
Resolution: SAT
Lifesaving
Issued 4 September 2001
Resolved
STENCIL PADDLES FOR LIFEFLOATS WITH VESSEL NAME.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Fire Fighting
Issued 4 September 2001
Resolved
REPLACE FIRE NOZZLE.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 4 September 2001
Resolved
CHECK ALL LIFEFLOATS FOR ROTTED LINES AND REPLACE AS NEEDED.
Condition: Unknown
Due 28 September 2001
Resolved 18 December 2001
Resolution: REPAIR SATISFACTORY.
Lifesaving
Issued 4 September 2001
Resolved
CONDUCT MAN OVERBOARD, FIRE AND ABANDON SHIP DRILL.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 4 September 2001
Resolved
INSTALL PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 28 September 2001
Resolved 18 December 2001
Resolution: INSTALLED AND TESTED.
Construction/Loadline
Issued 4 September 2001
Resolved
REPLACE SUCTION ON ENGINE ROOM BILGE PUMP
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Engineering
Issued 4 September 2001
Resolved
PROPERLY STENCIL FUEL SHUT OFFS.
Condition: Unknown
Due 28 September 2001
Resolved 18 December 2001
Resolution: STENCILED.
Lifesaving
Issued 4 September 2001
Resolved
REPLACE TEATHER LINES FOR WATERLIGHTS ON LIFEFLOATS.
Condition: Unknown
Due 5 September 2001
Resolved 5 September 2001
Lifesaving
Issued 4 September 2001
Resolved
REPLACE RETROFLECTIVE MATERIAL ON LIFEFLOAT BOTTOMS.
Condition: Unknown
Due 28 September 2001
Resolved 18 December 2001
Fire Fighting
Issued 4 September 2001
Resolved
PROVIDE BRACKET FOR STOWAGE OF FIRE HOSE.
Condition: Unknown
Due 28 September 2001
Resolved 18 December 2001
Resolution: MOUNTED.
Construction/Loadline
Issued 26 July 2001
Resolved
REMOVE EXCESS WIRING ON BILGE PUMP IN FUEL COMPT.
Condition: Unknown
Due 26 August 2001
Resolved 5 September 2001
Construction/Loadline
Issued 26 July 2001
Resolved
INSTALL METALLIC THRU-HULL FITTING ON ALL OVERBOARD PIPING.
Condition: Unknown
Due 28 September 2001
Resolved 18 December 2001
Resolution: RE-EVALUATED CURRENT FITTINGS AS EXISTING AND SATISFACTORY.
Engineering
Issued 26 July 2001
Resolved
INSTALL FLAME BOWLS ON GENSET RAYCORS.
Condition: Unknown
Due 26 August 2001
Resolved 1 August 2001
Lifesaving
Issued 26 July 2001
Resolved
INSTALL DIFFUSERS ON ALL OPEN LIGHTING AS REQUIRED.
Condition: Unknown
Due 26 August 2001
Resolved 5 September 2001
Construction/Loadline
Issued 5 June 2001
Resolved
INSTALL ACCESS AND MAKE AVAILABLE FOR INSPECTION VOID SPACE IN FOREPEAK PRIOR TO COMPLETION OF NEXT DRYDOCK.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Fire Fighting
Issued 17 July 2000
Resolved
PROVIDE SATISFACTORY TEST OF FIXED CO2 SYSTEM AND DELAY.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Construction/Loadline
Issued 17 July 2000
Resolved
REPAIR THRUL HULL AT JUNCTION OF MAIN DECK IN FUEL COMPARTMENT.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Fire Fighting
Issued 17 July 2000
Resolved
PERFORM SATISFACTORY TEST OF FIRE DETECTION SYSTEM.
Condition: Unknown
Due 17 July 2000
Resolved 17 July 2000
Lifesaving
Issued 16 September 1999
Resolved
POST LIFEJACKET DONNING PROCEDURES.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 16 September 1999
Resolved
INSTALL NEW HYDROSTATIC RELEASE ON 406 MHZ EPIRB.
Condition: Unknown
Due 16 September 1999
Resolved 22 September 1999
Unknown
Issued 16 September 1999
Resolved
PROCURE COPY OF 46 CFR SUBCAPTER "T".
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Lifesaving
Issued 16 September 1999
Resolved
INSTALL LADDER TO ACCESS PRIMARY LIFESAVING EQUIPMENT ABOVE PILOTHOUSE.
Condition: Unknown
Due 16 September 1999
Resolved 16 September 1999
Documentation
Issued 31 July 1999
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION REFLECTING CORRECT ADDRESS FOR OWNER OF VESSEL.
Condition: Unknown
Due 31 July 1999
Resolved 31 July 1999
Lifesaving
Issued 3 September 1998
Resolved
INSTALL 3-6' OF LINE AND HALYARD CLIP ON RING BUOY WATERLIGT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1998
Resolved 9 November 1998
Fire Fighting
Issued 3 September 1998
Resolved
PROVIDE 1 HAND FIRE/BILGE PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1998
Resolved 9 November 1998
Construction/Loadline
Issued 3 September 1998
Resolved
CONNECT CAPTIVE LINE ON AFT DECK HATCH._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1998
Resolved 9 November 1998
Lifesaving
Issued 3 September 1998
Resolved
LABEL LIFEFLOATS 22 PERSONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1998
Resolved 9 November 1998
Lifesaving
Issued 3 September 1998
Resolved
REPAIR 1 LIFEFLOAT WATERLIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 September 1998
Resolved 9 November 1998
Construction/Loadline
Issued 18 July 1997
Resolved
PROVIDE FIXED BILGE SUCTION TO THE LAZARETTE COMPARTMENT.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997