MAURY USCG vessel records Sign in
← All vessels

INSPIRATION

INSPIRATION is a 1997 offshore supply vessel. The Coast Guard has recorded 37 inspections since 1997, most recently in June 2019, along with 48 deficiencies and 3 casualty investigations between 2002 and 2016.

Records from 1997 to 2019. Most recent: inspection, 27 June 2019.

Built
1997
Last inspected
27 June 2019
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9132272 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCX7141
456981
Flag
UNITED STATES
368647000
Maury page id
psix-456981

Inspections, by type

…with no type recorded7
Years with a record 17 calendar years (1997–2019)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)251.0 ft × 56.0 ft × 18.8 ft
Registered tonnagegross 291 / net 198
ITC dimensions (L × B × D)251.0 ft × 56.0 ft × 18.8 ft
ITC tonnagegross 2,316 / net 1,020
BuilderNORTH AMERICAN SHIPBLDG · MOBILE, AL, UNITED STATES · built 1997
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 September 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it198 - Regulatory (Subpart C or D), Net Ton
1020 - Convention (Subpart B), Net Ton
2371 - Dead Weight, Ton
291 - Regulatory (Subpart C or D), Gross Ton
2316 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCX7141MMSI 368647000 · active · compulsorily equipped · granted 11 August 2017, expires 2 September 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STARFLEET PATRIOT Passenger (Inspected) · MISLE 511644 · 1 November 2002 · activity 1700940CHALLENGE Tank Ship · MISLE 53002 · 30 January 2002 · activity 1484107

Inspection history · 37

27 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6728038
7 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6503359
11 November 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6306437
15 June 2017 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6177478
25 April 2017 Annual Inspection · Administrative Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6132668
31 January 2017 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6080615
6 May 2016 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5909699
2 May 2016 COI Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5865807
8 April 2016 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5850160
9 May 2014 Periodic Inspection · Administrative Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4853583
5 June 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4333333
20 September 2010 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3841144
23 February 2009 Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3420349
9 July 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3262356
23 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245289
4 September 2007 Re-Inspection · MTSA Verification · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3048101
17 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2751300
21 June 2006 Drydock Extension · Hull Examination · Internal Structural Exam · Cargo Tank Internal · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2686700
17 October 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2516072
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502144
8 September 2005 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501177
15 June 2005 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2391246
21 June 2004 Cargo Tank Internal · Re-Inspection · Underwater Inspection in lieu of Drydock · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2107065
22 January 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1990903
30 November 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1712981
1 November 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1700940
10 October 2002 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1687977
12 September 2002 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1675195
10 September 2002 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1674004
13 February 2002 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1486126
30 January 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1484107
25 June 2001 Inclining Experiment · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473420
29 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446601
15 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 103781
10 November 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436003
16 October 1997 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113749
27 August 1997 Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1400629

Deficiency record · 48

10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 7 August 2018 Resolved
Vessel has failed to report via LRIT per 33 CFR 169.230.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2017 Resolved
Sternlight and anchor light found inoperable. Repair or replace inoperable navigation lights and prove operation.
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 25 April 2017
Resolution: Repaired during inspection.
Engineering › Steering Gear System › Power Unit
Issued 2 May 2016 Resolved
auxilary steering did not work.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2016
Resolved 2 May 2016
Resolution: cleared onboard by class
Electrical › Electric Generation Source (service) › Generator
Issued 2 May 2016 Resolved
centerline generator was offline and would not start or supply power to the vessel
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2016
Resolved 3 May 2016
Resolution: Class cleared item onboard
Fire Fighting › Fire Hydrants › Condition
Issued 2 May 2016 Resolved
port side 01 deck fireplug leaked by and charged the hose in it's holder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2016
Resolution: cleared onboard prior to departure of CGMI. vessel rep replaced the plug
Communications › Radio Communications › Satellite Communications Capability
Issued 2 May 2016 Resolved
vessel is certified to make sea area a3 voyaged but does not have two sufficent means of matinence. shore base maitenance was provided but vessel did not have either an additional Immarsat or SSB IAW 74SOLAS(14)IV/15.7. this requirment is subject to an ongoing appeal, and the requirments written have been stayed pending the results of the appeal
Action required: 705 - Other - as specified
Resolved 11 October 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 2 May 2016 Resolved
vessel did not have enough spare fire extinguishers onboard
Due 9 May 2016
Resolved 3 May 2016
Resolution: cleared via class society surveyor
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 2 May 2016 Resolved
cargo ship safety radio certificate did not specify a sea area. required vessel rep to provide a correct CSSR cert.
Due 2 June 2016
Resolved 13 May 2016
Resolution: vessel rep provided new CSSR cert
Communications › Radio Communications › EPIRB
Issued 9 May 2014 Resolved
EPIRB appeared to have been dropped and would not operate during test. Service or replace Epirp prior to operation of the vessel.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2014
Resolution: New EPIRB placed onboard and registered.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 9 May 2014 Resolved
Vessel only outfitted with 2 Line-throwing appliances. Vessel required 4.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2014
Resolution: 4 Line-throwing appliances placed onboard.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 20 September 2010 Resolved
FRC was not able to run during drill, prove proper operation for CG inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2010
Resolution: CGMI attended vessel and observed FRC launch, run fwd/rev and recover to vessel
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 4 September 2007 Resolved
Update all fire extinguisher IMO labels throughout vessel.
Due 4 October 2007
Resolved 7 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 September 2007 Resolved
Renew extinguisher on C14 bracket.
Due 18 September 2007
Resolved 7 September 2007
Engineering › Fuel Oil Service System › Hose
Issued 4 September 2007 Resolved
Repair leaking hose on STBD aft Inboard HHP engine.
Due 4 October 2007
Resolved 7 September 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 September 2007 Resolved
Repair light
Due 4 October 2007
Resolved 7 September 2007
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 4 September 2007 Resolved
Provide a closure device for the Poly Tank on the aft deck.
Due 4 October 2007
Resolved 7 September 2007
Fire Fighting › Fixed Deck Foam System › Monitors
Issued 4 September 2007 Resolved
Provide foam analysis for AFFF foam for both fire monitors.
Due 4 October 2007
Resolved 7 September 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 4 September 2007 Resolved
Repair eye wash station on port 01 deck.
Due 4 October 2007
Resolved 7 September 2007
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 4 September 2007 Resolved
Demonstrate proper operation of engine room watertight fire door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2007
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 4 September 2007 Resolved
Re-mark SOLAS decals properly
Due 4 October 2007
Resolved 7 September 2007
Communications › Alarms/Indicators › Fire Alarm
Issued 4 September 2007 Resolved
Renew fire alarm on bridge.
Due 18 September 2007
Resolved 7 September 2007
Lifesaving › Hand Flares › Marking
Issued 4 September 2007 Resolved
Mark distress signal box with flourescent orange.
Due 4 October 2007
Resolved 7 September 2007
Communications › Radio Communications › EPIRB
Issued 4 September 2007 Resolved
Move EPIRB from flying bridge down one level, as per IMO COMSAR Circular 32.
Due 4 October 2007
Resolved 7 September 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 September 2007 Resolved
Conduct a night time drill by October 4, 2007.
Due 4 October 2007
Resolved 7 September 2007
Deck/Cargo › Cargo Stowage › General
Issued 4 September 2007 Resolved
Maintain proper documentation for MPT's under 49 CFR 172.202
Due 4 October 2007
Resolved 7 September 2007
Communications › Alarms/Indicators › General Alarm
Issued 21 June 2006 Resolved
Demonstrate Proper operation of General Alarm upon activation of two smoke detectors in the same zone.
Action required: 705 - Other - as specified
Due 24 August 2006
Resolved 14 August 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 June 2006 Resolved
Provide Annual Automation Test Audit for automation test procedures.
Due 21 July 2006
Resolved 21 June 2006
Construction/Loadline › Penetrations › Gasket
Issued 21 June 2006 Resolved
Install missing J-bolt on Room 101 tonnage opening.
Due 14 July 2006
Resolved 21 June 2006
Fire Fighting › Emergency Fire Pumps › Capacity
Issued 21 June 2006 Resolved
demonstrate proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2006
Lifesaving › Rescue Boat › Propeller
Issued 21 June 2006 Resolved
Install propeller guard
Due 21 July 2006
Resolved 14 August 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 June 2006 Resolved
Demonstrate proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2006
Engineering › Pressure Vessel › Relief Valve
Issued 21 June 2006 Resolved
Provide documentation of proper operation of all onboard.
Due 30 June 2006
Resolved 23 June 2006
Lifesaving › Rescue Boat › Propulsion Casing/Protection
Issued 17 October 2005 Resolved
Install propeller guard on rescue boat prior to an Int'l voyage.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 July 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 October 2005 Resolved
Install spray shielding on fuel oil piping prior to Int'l voyage.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 July 2008
Lifesaving › Visual Distress Signals (General)
Issued 22 January 2004 Resolved
ARM BRIDGE WING LIFE RINGS WITH SMOKE CANISTERS. LEGACY COMPONENT DESC: Storage
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 January 2004
Engineering › Fuel Oil Service System › Filter
Issued 22 January 2004 Resolved
PROVIDE AND INSTALL METAL PLUGS IN ALL RACOR FILTERS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 22 January 2004
Communications › Visual Communication
Issued 22 January 2004 Resolved
STENCIL ENGINE ROOM EMERGENCY ESCAPE HATCH WITH "EMERGENCY EXIT KEEP CLEAR. LEGACY COMPONENT DESC: EMERGENCY ESCAPE
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 22 January 2004
Fire Fighting › Nozzles › Type
Issued 22 January 2004 Resolved
PROVIDE A FOAM VARI NOZZEL AND EDUCTOR.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 January 2004
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 22 January 2004 Resolved
DEMONSTRATE PROPER OPERATION OF REMOTE SHUT DOWN FOR FUEL OIL CENTERFUGAL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 22 January 2004
Fire Fighting › Remote Fuel Shutoff
Issued 22 January 2004 Resolved
DEMONSTRATE PROPER OPERATION OF FUEL OIL CENTRIFUGAL REMOTE STOP. LEGACY COMPONENT DESC: CENTRIFUGAL REMOTE STOP
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 22 January 2004
Lifesaving › Lifebuoys
Issued 22 January 2004 Resolved
RENEW RETRO-REFLECTIVE TAPE ON ALL LIFE RINGS. LEGACY COMPONENT DESC: RETO-REFLECTIVE TAPE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 January 2004
Construction/Loadline › Structures › Door
Issued 22 January 2004 Resolved
ADJUST DOGS ON GALLEY WATER TIGHT DOOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 January 2004
Engineering › Diesel Engine (auxiliary)
Issued 10 September 2002 Resolved
Replace or repair suction line for forward bow thruster.
Due 10 October 2002
Resolved 12 September 2002
Resolution: Repaired suction line on forward bow thruster
Construction/Loadline › Markings
Issued 10 September 2002 Resolved
Repaint loadline deck markings and stern draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 10 October 2002
Resolved 10 September 2002
Resolution: All markings have been painted.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 September 2002 Resolved
Remove and discard all outdated medical supplies and replace with current meds.
Due 10 October 2002
Resolved 10 October 2002
Resolution: Vessel has been provide with new medical kits.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 10 September 2002 Resolved
Provide this office with a copy of the third party fire fighting equipment report.
Due 1 November 2002
Resolved 10 October 2002
Resolution: Vessel annual servicing report was faxed to this office.
Navigation › Collision/Grounding Avoidance
Issued 10 September 2002 Resolved
Remove gloss black paint on running light screens and properly paint with Matte black. LEGACY COMPONENT DESC: Navigation Lights
Due 10 October 2002
Resolved 10 September 2002
Resolution: Nav light screens have been painted matte black.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 September 2002 Resolved
Provide documentation approving current fiber grating installed throughout vessel. Install steel access to fire monitor stations. LEGACY COMPONENT DESC: grating
Action required: 705 - Other - as specified
Due 10 October 2002
Resolved 5 March 2004

Casualty record · 3

30 January 2002Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 1484107
1 November 2002Routine · role: Involved in a Marine Casualty · activity 1700940
6 May 2016Routine · role: Involved in a Marine Casualty · activity 5909699
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HR HUGHES (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record