Records from 1997 to 2012. Most recent: inspection, 24 July 2012.
Inspection history · 78
24 July 2012
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4391879
6 June 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4335296
19 March 2010
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3697075
10 March 2010
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ILO-147 Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3692120
4 May 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3466787
15 April 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3452747
2 March 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3426187
14 January 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3393713
12 December 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3378593
1 December 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3371591
1 December 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3371666
14 October 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3344833
30 September 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3337687
16 September 2008
ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3325782
12 September 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3332861
25 August 2008
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3308234
15 July 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3268266
15 April 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3184294
4 March 2008
PII Safety Exam · ISPS III Exam · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3157776
5 February 2008
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3141816
18 December 2007
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3117302
27 June 2007
Random ISPS/MTSA/PSC
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2975260
9 May 2007
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2927264
6 February 2007
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2868063
29 January 2007
Ballast Water Examination · Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2864273
24 January 2007
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2862003
17 October 2006
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2802677
22 August 2006
Random ISPS/MTSA/PSC
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2755491
10 January 2006
Random ISPS/MTSA/PSC
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2564555
29 November 2005
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2548489
15 November 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2534776
2 March 2005
Random ISPS/MTSA/PSC
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2305405
15 November 2004
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2240956
23 June 2004
MTSA/ISPS Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2107751
11 February 2004
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2004346
28 October 2003
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1936590
21 October 2003
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1936417
24 July 2003
In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1855475
15 May 2003
In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1797015
11 April 2003
In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1771688
20 August 2002
Annual Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1663555
27 March 2002
Ballast Water Examination · Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1597513
14 March 2002
Periodic Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1493819
9 January 2002
Administrative Inspection
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1476795
8 October 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 538069
4 October 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 536059
27 September 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 489619
24 September 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 515674
20 September 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 532249
17 September 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 459886
14 September 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 506245
31 August 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 530608
13 August 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 464251
7 August 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 293292
25 July 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 292299
22 July 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 680637
5 July 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 484482
29 May 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 290385
1 May 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 289517
13 March 2001
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 288065
13 September 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 282112
9 August 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 280283
26 April 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 277337
5 April 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 276494
17 February 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 274920
1 November 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 434541
3 October 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 433378
14 September 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 432724
10 August 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 431506
9 March 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 485260
3 March 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 426129
22 February 1999
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 425810
30 October 1998
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 803333
12 August 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 419160
8 June 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 418800
5 March 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 413057
6 July 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 405357
10 June 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404576
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 6 June 2012
No resolution recorded
Fire doors in main vertical zone bulkheads shall be of self-closing type with simple and easy means of release from the open position. Main stairwell door on boat deck cannot close from open position.
Action required: 705 - Other - as specified
Due 20 June 2012 — due date passed with no resolution recorded
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2012
No resolution recorded
GMDSS live boats radio batteries shall comply with conditions set forth by the administration ensuring it is of durable type and adequate capacity. One of the three GMDSS lifeboat radios found using a back-up battery which has been expired since March 2000.
Action required: 705 - Other - as specified
Due 20 June 2012 — due date passed with no resolution recorded
Lifesaving › Hand Flares › Approval
Issued 6 June 2012
No resolution recorded
Lifeboat equipment shall consist of 06 hand flares of an approved type. Vessels lifeboats consist of hand flares of an unapproved SOLAS type.
Action required: 705 - Other - as specified
Due 20 June 2012 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 June 2012
No resolution recorded
Piping to and from oily residue tanks shall have no direct connectiojn overboard other than the approved type. OWS system has current setup that would allow bypass of OWS system.
Due 20 June 2012 — due date passed with no resolution recorded
Lifesaving › Buoyant Smoke Signals › General
Issued 10 March 2010
Resolved
Starboard and port side lifeboats not equipped with two buoyant smoke signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2010
Resolution: Two Buoyant Smoke Signals were available on Guam. The required two more will be obtained by the vessel in Saipan.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 March 2010
Resolved
Vessel's fixed fire fighting system for CO2 found with actuator for CO2 bottle #8, compromised and disconnected.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2010
Resolution: CO2 system was corrected by contractors
Lifesaving › Launching Appliances › Davit
Issued 10 March 2010
Resolved
One ton crain on boat deck aft
Due 9 April 2010
Resolved 27 May 2010
Resolution: Provided proof from class of repair and use.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 10 March 2010
Resolved
Missing mechanical plug for each fuel oil containments on port and starboard sides of the vessel
Due 9 April 2010
Resolved 11 March 2010
Resolution: The missing mechanical plugs have been replaced on the port and starboard sides of the vessel
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 10 March 2010
Resolved
Missing mechanical plug for each fuel oil containments on port and starboard sides of the vessel.
Due 19 March 2010
Resolved 19 March 2010
Resolution: Vessel installed mechanical plugs for each containment on port and starboard sides verified to the satisfaction of the attending USCG.
Documentation › Logs/Records › Oil Record Book
Issued 16 September 2008
Resolved
Oil record book was not available for review by Coast Guard personnel.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2008
Resolved 16 September 2008
Resolution: Oil record book has been located and reviewed by Coast Guard personnel. All entries considered satisfactory by the attending Marine Inspector.
Fire Fighting › Fire Main › Condition
Issued 16 September 2008
Resolved
Fire main piping fractured and leaking forward of cargo holds.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2008
Resolved 16 September 2008
Resolution: Fractured fire main section has been repaired and is now fully functional, to the satisfaction of the attending Coast Guard marine inspector.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 September 2008
Resolved
High bilge water alarm not operable.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2008
Resolved 16 September 2008
Resolution: Conducted test on high bilge water alarm to confirm proper operation of equiptment all test sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 16 September 2008
Resolved
Portable CO2 fire extinguisher missing in control room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2008
Resolved 16 September 2008
Resolution: CO2 fire extinguisher has been replaced and is fully functional, to the satisfaction of the attending Coast Guard marine inspector.
Fire Fighting › Self-contained Breathing Apparatus › Quantity
Issued 16 September 2008
Resolved
Emergency escape breathing apparatus was missing form its storage rack.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2008
Resolved 16 September 2008
Resolution: New EEBD has been placed in proper storage area and deficiency has been cleared to the satisfaction of the attending Coast Guard marine inspector
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 16 September 2008
Resolved
Portable PKP fire extinguisher was missing from lower engine room storage bracket.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2008
Resolved 17 October 2008
Resolution: Portable PKP fire extinguisher has been properly replaced to the satisfaction of the attending Coast Guard marine inspector.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 16 September 2008
Resolved
Main switch board not accessible aft.
Action required: 705 - Other - as specified
Due 16 October 2008
Resolved 17 October 2008
Resolution: Deficiency has been rectified to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 16 September 2008
Resolved
Wirring conduit for emergency stop of cargo hold cover plates rusted port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 September 2008
Resolved 17 September 2008
Resolution: Dificiency has been rectified to the satisfation of the attending Coast Guard Marine Inspector.
Electrical › Lighting (service) › Switch
Issued 16 September 2008
Resolved
Paint locker light switch broken and missing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2008
Resolved 17 October 2008
Resolution: Paint locker light switch has been replaced and properly installed to the satisfaction of the attending Coast Guard Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 September 2008
Resolved
OWS bilge suction pipe has a hole above the check valve.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 October 2008
Resolved 17 October 2008
Resolution: OWS bilge suction line has been removed, repaired and reinstalled to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 4 March 2008
Resolved
Liferaft approved for 10 passengers. 11 crew were onboard vessel.
Due 4 March 2008
Resolved 4 March 2008
Resolution: Vessel leaving one off-going crew member prior to departure.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 February 2008
Resolved
Stern light junction box/support bracket fractured. Repair to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 March 2008
Resolved 4 March 2008
Resolution: Corrected.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 5 February 2008
Resolved
Wires exposed in emergency escape shaft light in engine room. Repair to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 March 2008
Resolved 4 March 2008
Resolution: Repaired.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 5 February 2008
Resolved
Excessive amounts of insects in food stores, accommodations, etc. Correct to the satisfaction of the Administration.
Action required: 705 - Other - as specified
Due 6 March 2008
Resolved 4 March 2008
Resolution: Corrected to the satisfaction of USCG.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 5 February 2008
Resolved
Existing non conductive mat in engine control room is deteriorated. Repair to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 March 2008
Resolved 4 March 2008
Resolution: Conductive mat replaced.
Fire Fighting › Fire Main › Condition
Issued 27 June 2007
Resolved
Discovered a 4-inch corroded crack in the fire main, on the port-bow.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 31 July 2007
Resolution: VSL provided proof that the fire main has been repaired to the satisfation of class society.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 27 June 2007
Resolved
VSL did not have a "Discharge of Oil Prohibited" posted by the OWS.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 31 July 2007
Resolution: VSL provided proof that they properly displayed an oil discharge placard near the OWS.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 27 June 2007
Resolved
VSL failed to have an identification placard on the MSD.
Action required: 705 - Other - as specified
Due 27 July 2007
Resolved 31 July 2007
Resolution: VSL provided proof that they placed an identification placard on the MSD.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 29 January 2007
Resolved
The echosounder recorder was not working properly, due to a missing stylus.
Action required: 705 - Other - as specified
Resolved 31 January 2007
Resolution: The vessel installed a new stylus.
Communications › Radio Communications › EPIRB
Issued 29 January 2007
Resolved
The foam ring around the EPIRB has deteriorated, and the EPIRB will sink when deployed. The M/V SUPER SHUTTLE will be using the EPIRB from the C/B PATRIOT to subsitute until the EPIRB that was ordered arrives.
Action required: 705 - Other - as specified
Due 12 February 2007
Resolved 23 February 2007
Resolution: Sector Guam received fax from Seabridge Inc of new EPIRB on board vessel 21FEB07. Vessel is in compliance.
Lifesaving › Inflatable Liferafts › Servicing
Issued 22 August 2006
Resolved
Inflatable liferaft is expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 August 2006
Resolved 22 August 2006
Resolution: New liferaft delivered to ship.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 15 November 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 15 - Rectify deficiencies by next port
Due 29 November 2005
Resolved 29 November 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 15 November 2005
Resolved
US COAST PILOT OUTDATED. REPLACE WITH VALID 2005 EDITION
Action required: 15 - Rectify deficiencies by next port
Due 29 November 2005
Resolved 29 November 2005
Resolution: Temporary pilot list issued by Amyth: Nate [phone withheld]
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 November 2005
Resolved
NAME OF VESSEL ON LIFEBUOYS FADED. LINE IS WORN. RESTENCIL REQUIRED INFORMATION ON ALL LIFE BUOYS AND REPLACE ALL LINE.
Action required: 15 - Rectify deficiencies by next port
Due 29 November 2005
Resolved 29 November 2005
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 October 2003
Resolved
REMOVE ALL STORAGE ITEMS IN HOSPITAL SPACE HEAD. LEGACY COMPONENT DESC: Hospital Space
Action required: 15 - Rectify deficiencies by next port
Resolved 11 February 2004
Fire Fighting › Firemans Outfit
Issued 21 October 2003
Resolved
PROVIDE FIRE PROOF TENDING LINES FOR ALL FIREMANS OUTFITS. LEGACY COMPONENT DESC: Lifeline
Due 30 January 2004
Resolved 28 October 2003
Accommodation/Occupational Safety › Potable Water System
Issued 21 October 2003
Resolved
PROVIDE HOT WATER SERVICE TO THE GALLEY FOR CLEANING/SANITIZING PURPOSES.
Due 30 January 2004
Resolved 11 February 2004
Construction/Loadline › Penetrations
Issued 21 October 2003
Resolved
MAKE PENETRATION AT DOOR AFT SUPERSTRUCTURE BULKHEAD WATERTIGHT OR PROVIDE ORIGINAL BUILDERS PLANS APPROVING THE INSTALLATION.
Due 30 January 2004
Resolved 11 February 2004
Lifesaving › Lifeboat
Issued 21 October 2003
Resolved
MODIFY THE LIFEBOAT LAUNCHING PROCEDURES TO INCLUDE A STEP WHICH SECURES LIFE BOATS ALONG SIDE THE EMBARKATION DECK TO ALLOW SAFE ENTRY FOR THE CREW. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Construction/Loadline › Structures
Issued 21 October 2003
Resolved
PERMANENTLY REPAIR ALL WATER TIGHT DOORS THROUGHOUT THE VESSEL THAT HAVE HOLES/PENETRATIONS. LEGACY COMPONENT DESC: Door
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 October 2003
Resolved
PLACE CO2 100 LB. BOTTLE IN THE CO2 ROOM ON A RAISED STRUCTURE OFF THE DECK. LEGACY COMPONENT DESC: Tanks
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 October 2003
Resolved
PROVIDE SECONDARY (MANUAL) CO2 RELEASE PROCEDURES IN CO2 ROOM. LABEL VALVES TO COINCIDE WITH PROCEDURES. LEGACY COMPONENT DESC: Operating Controls
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Lifesaving › Launching Appliances
Issued 21 October 2003
Resolved
REPLACE THE WASTED NUT & BOLT SECURING PINS ON THE AFT SUPPORTS FOR THE PORT AND STARBOARD LIFEBOATS. LEGACY COMPONENT DESC: Release Mechanism
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Deck/Cargo › Cargo Stowage
Issued 24 July 2003
Resolved
UN0012 CARGO 1.4S EXPLOSIVES REQUIRED TO BE IN TRANSPORT UNIT (CONTAINER).
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ABOVE DEFICIENCIES. LEGACY COMPONENT DESC: Transport Unit (Container)
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 28 October 2003
Documentation › Manifests/Lists
Issued 24 July 2003
Resolved
SHIPPING PAPERS NOT ONBOARD OR IMMEDIATELY AVAILABLE.
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ABOVE DEFICIENCIES. LEGACY COMPONENT DESC: Shipping Papers
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 July 2003
Documentation › Manifests/Lists
Issued 24 July 2003
Resolved
SHIPPING DESCRIPTION NOT IN ORDER AS DESCRIBED BY 49 CFR 176.30.
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ABOVE DEFICIENCIES. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 July 2003
Documentation › Manifests/Lists
Issued 24 July 2003
Resolved
STOWAGE LOCATION OF CARGO NOT ON DCM.
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ABOVE DEFICIENCIES. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 July 2003
Documentation › Manifests/Lists
Issued 24 July 2003
Resolved
MASTER/DECK OFFICER SIGNATURE NOT ON DCM.
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ABOVE DEFICIENCIES. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 July 2003
Documentation › Manifests/Lists
Issued 24 July 2003
Resolved
DATE BY PREPARER NOT ON DCM
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ABOVE DEFICIENCIES. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 July 2003
Documentation › Manifests/Lists
Issued 24 July 2003
Resolved
PACKAGING GROUP OF CARGO NOT ON DCM.
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ABOVE DEFICIENCIES. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 July 2003
Documentation › Manifests/Lists
Issued 24 July 2003
Resolved
NUMBER OF AND DESCRIPTION OF PACKAGING NOT ON DCM.
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ABOVE DEFICIENCIES. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 July 2003
Documentation › Manuals/Policy Documentation
Issued 24 July 2003
Resolved
PROVIDE PROPOSAL TO ADDRESS AND CORRECT ITEMS 1 - 8.
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 24 July 2003
Deck/Cargo
Issued 15 May 2003
Resolved
Dangerous Cargo Manifest N.O.S. entries failed to have technical name in non-adherence with 49 CFR 176.30. The lack of a cargo technical name creates increased ability to safely respond should there be cargo leakage or accident.
Due 15 May 2003
Resolved 15 May 2003
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 11 April 2003
Resolved
"N.O.S" hazardous materials described on the dangerous cargo manifest failed to have technical description in non-adherence with 49 CFR 176.30.
Due 11 April 2003
Resolved 11 April 2003
Resolution: Cargo offloaded.
Documentation › Manifests/Lists
Issued 14 March 2002
Resolved
Examination of Dangerous Cargo Manifest (DCM) revealed that Emergency Response tel #'s required by 49 CFR 176.30(a) for 12 of 13 containers holding hazardous materials werer: (1) missing, (2) incomplete, (3) not 24 hr, or (4) connected to a party w/o immediate access to response information. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Due 15 March 2002
Resolved 27 March 2002
Resolution: CLEARED BY [name withheld] GUAM.
Fire Fighting
Issued 13 March 2001
Resolved
Emergency escape fire door, located by OWS, does not close properly - SOLAS60, Regulation 13.
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Engineering
Issued 13 March 2001
Resolved
Transfer procedures do not include emergency fueling operations of GEN SET - 33 CFR 155.750.
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Engineering
Issued 13 March 2001
Resolved
Fuel Transfer hose used to fill GEN SET in emergency situations is not in compliance with safety regulations - 33 CFR 155.800.
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Unknown
Issued 13 March 2001
Resolved
Class society must approve the carriage of a GEN SET on board prior to nexttransportation of a GEN SET - SOLAS 74 I/11.
Condition: Unknown
Due 26 May 2001
Resolved 29 May 2001
Electrical
Issued 9 August 2000
Resolved
Make proper repairs to light fixtures and electrical supply cable located at the main deck level in the forward (bow) trunk. Repairs to be in accordance with SOLAS 60 CH II, REG. 27.
Condition: Unknown
Due 17 September 2000
Resolved 17 September 2000
Documentation
Issued 9 August 2000
Resolved
Provide training records for crew members considered as Hazmat workers. Training to be in accordance with 49CFR172.700-704, AND 49CFR176.13.
Condition: Unknown
Due 17 September 2000
Resolved 17 September 2000
Fire Fighting
Issued 5 April 2000
Resolved
Provide fire resistant life line for fireman suit located on the bridge._x001C_ SOLAS 60 II/63(c)
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Construction/Loadline
Issued 14 September 1999
Resolved
Engineroom escape route door on main deck (port side aft) is warped and will not fully close. ILLC I/15
Condition: Unknown
Due 3 October 1999
Resolved 3 October 1999
Engineering
Issued 10 August 1999
Resolved
Pressure test the bunker piping to at least 1.5 times maximum allowable working pressure prior to taking on bunkers in any U.S. port. 33CFR156.170.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Documentation
Issued 10 August 1999
Resolved
Provide a written waste management plan for the vessel. MARPOL 73/78 Annex V/9.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 10 August 1999
Resolved
Aft man rope on the port lifeboat davit is too short. Install the proper length man rope. SOLAS 74 III/19.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 10 August 1999
Resolved
Port lifeboat flashlight inoperative, and the spare batteries and light bulb are missing. Provide operable flashlight, spare batteries and light bulbs. SOLAS 74 III/19.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Navigation
Issued 10 August 1999
Resolved
Provide tidal current tables for the vessel's operating area. 33CFR164.33
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Navigation
Issued 10 August 1999
Resolved
Provide heaving line for the pilot station. SOLAS 74 V/17.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Documentation
Issued 10 August 1999
Resolved
Provide proof of crew vessel familiarization. STCW VI/1, A-VI/1
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Construction/Loadline
Issued 10 August 1999
Resolved
Make the watertight doors (2 each) and hatches (6 each) located on the focsle watertight. ILLC I/15
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Fire Fighting
Issued 10 August 1999
Resolved
Post operating instructions for the fixed CO 2 system, in a language of thecrew, at the remote actuation station and on the door to the CO2 room. Current instructions are in German. SOLAS 74 III/8, III/53.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 10 August 1999
Resolved
Install waterlight on the PFD in the engine control room. SOLAS 74 I/11
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Accommodation/Occupational Safety
Issued 10 August 1999
Resolved
In lieu of soft patch, make permanent repair to the four inch sewage line above the workbench in the engine control room. SOLAS 74 I/11
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Accommodation/Occupational Safety
Issued 10 August 1999
Resolved
Post sign on sewage overboard valve "Keep closed within 3 miles from shore". 33CFR159.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Accommodation/Occupational Safety
Issued 10 August 1999
Resolved
Paint sewage line hose connections black, not red, and label the sewage valves so they are not mistaken for fire hydrants. SOLAS 74 I/11.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 10 August 1999
Resolved
The person-in-charge and second-in-charge of each lifeboat shall have a crew list. SOLAS 74 III/10.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Fire Fighting
Issued 10 August 1999
Resolved
Remove rubber hose and prove operation/closure of the funnel damper in the upper stack space. SOLAS 74 I/11.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 10 August 1999
Resolved
Properly label vessel name and install retro-reflective tape on the port- stern ring buoy. SOLAS 74 III/30.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Electrical
Issued 10 August 1999
Resolved
Renew the cracked starting batteries for #1 and #2 ship service generators.SOLAS 74 I/11.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Documentation
Issued 10 August 1999
Resolved
Update all copies of the fire control plan to show the location of each firemen's suit. SOLAS 74 II-2/20
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Fire Fighting
Issued 10 August 1999
Resolved
Prove proper closure of the fire screen door to the galley entrance. SOLAS 74 I/11.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 10 August 1999
Resolved
Update all copies of the muster list to include duties for each crew memberin the event of a fire and abandon ship. SOLAS 74 III/18, III/53
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 10 August 1999
Resolved
Reinstall and prove proper operation of the port and stbd lifeboat davit limit switches. SOALS 74 III/19.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Documentation
Issued 10 August 1999
Resolved
Provide written company instructions to the master with policies and procedures for vessel crew familiarization. STCW I/14, A-I/14
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Engineering
Issued 10 August 1999
Resolved
Install insulation on the boiler exhaust piping. SOLAS 74 I/11
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 22 February 1999
Resolved
Port and Starboard Lifeboat falls adequate but deteriorating around the wire eyesplices and need to be renewed. SOLAS 74 (amended) III/19.4. Correct within 30 days to the satisfaction of Class Society surveyor.
Condition: Unknown
Due 22 March 1999
Resolved 10 August 1999
Documentation
Issued 22 February 1999
Resolved
International Shore Connection not shown on vessel's fire control plan. SOLAS 74 (amended) II-2/20.1. Correct within 30 days.
Condition: Unknown
Due 7 March 1999
Resolved 7 March 1999
Documentation
Issued 22 February 1999
Resolved
Contact phone numbers for COTP Guam missing in the vessel's SOPEP. 33 CFR 151.26. Correct and update contact phone numbers for COTP Guam within 30 days.
Condition: Unknown
Due 7 March 1999
Resolved 7 March 1999
Lifesaving
Issued 8 June 1998
Resolved
Crew not adequately trained on lifeboat sailing procedures, correct as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Deck/Cargo
Issued 8 June 1998
Resolved
Container TEXU 515855 incorrectly placarded as containing both a flammable and corrosive, correct as per 49CFR172.502(a).
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Aft ring bouy light not working, correct as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Port side aft davit span wire shackle improperly secured creating risk of loss of span wire and risk to merchant mariners, SOLAS (amended) 74 III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Port lifeboat missing mast wire stays, provide as per SOLAS 74 (amneded) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Port side engine room emergency escape used to store equipment/materials, correct as per SOLAS 74 (amended) I/11.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Center line aft deck house store room improperly used to store paint and other flammable materials, correct as per SOLAS 74 (amended) I/11.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
CO2 room improperly used to stow miscellaneous gas cylinders and other equipment, correct as per SOLAS 74 I/11.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Starboard lifeboat missing tiller-rudder connecting pin, correct as per SOLAS (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Illumination in CO2 room inoperative, correct as per SOLAS 74 (amended) I/11.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Paint thinner and paints stowed around fire station on stern, remove as perSOLAS 74 I/11.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Engineering
Issued 8 June 1998
Resolved
No containment around fueling stations and fuel tank vents, correct as per 33CFR155.320.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Fire Fighting
Issued 8 June 1998
Resolved
Insufficient evidence exists that fire extinguishing system to paint lockerin forecastle is adequate for flag state requirements, SOLAS 74 (amended) I/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Navigation
Issued 8 June 1998
Resolved
Ball dayshape deteriorated, repair as per 1973 COLREGS.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Starboard lifeboat lamp is not functional, correct as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Starboard lifeboat mast sheeves not operable, repair as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Port lifeboat rudder missing retaining pins, correct as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Fire Fighting
Issued 8 June 1998
Resolved
No fire hose, at forward port bow fire hose box, replace as per SOLAS (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Starboard lifeboat mast does not have wire stays, provide as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Starboard lifeboat compass illumination inoperable, repair as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Starboard lifeboat does not have a stern sea painter, provide as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Documentation
Issued 8 June 1998
Resolved
Captain had no proof of medical exam, provide evidence as per ILO/147.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Hydraulic oil spilled on foward deck port side, clean as per OPA 90.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Documentation
Issued 8 June 1998
Resolved
Oil transfer procedures not complete, missing: list of products_x001C_ transferred; line diagram; procedures for emptying containment; number of persons required; duties by title; for tending moorings; topping off; correct as per 33CFR155.750/155.720.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Deck/Cargo
Issued 8 June 1998
Resolved
Container APLU 962666 incorrectly placarded as a corrosive, correct as per 49 CFR 172.502(a).
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Fire Fighting
Issued 8 June 1998
Resolved
Fire hose missing from engine room, in way of engine room port side emergency escape, replace as per SOLAS 74 (amended) II-2/21.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Fire Fighting
Issued 8 June 1998
Resolved
Stern 0-1 deck, fire control plan contained in container is deteriorated, replace as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Port lifeboat missing stern sea painter, provide as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Starboard life boat missing bouyant heaving line, provide as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Port lifeboat lantern non-functional (no wick), correct as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Port lifeboat has no bouyant heaving line, provide as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Lifesaving
Issued 8 June 1998
Resolved
Port lifeboat tiller arm missing retaining pins, correct as per SOLAS 74 (amended) III/19.
Condition: Unknown
Due 16 August 1998
Resolved 16 August 1998
Navigation
Issued 10 June 1997
Resolved
HYDRAULIC FLUID LEVEL ALARM FOR STEERING PUMP WAS INOPERABLE. SOLAS 60 I/11
Condition: Unknown
Due 7 July 1997
Resolved 7 July 1997
Documentation
Issued 10 June 1997
Resolved
OIL TRANSFER PROCEDURES NOT UPDATED TO MEET 33 CFR 155.750.
Condition: Unknown
Due 7 July 1997
Resolved 7 July 1997
Navigation
Issued 10 June 1997
Resolved
MANUEVERING INFORMATION MISSING. 33 CFR 164.35(j)(1)
Condition: Unknown
Due 7 July 1997
Resolved 7 July 1997