Records from 1998 to 2022. Most recent: inspection, 16 September 2022.
Inspection history · 84
16 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7596947
3 August 2021
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7283568
20 March 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6929592
3 March 2020
Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6919694
1 November 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6847367
19 October 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6564528
15 June 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6445090
23 May 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6422763
10 May 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6410785
4 May 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6405739
3 May 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6410031
25 April 2018
ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6398219
25 April 2018
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6407969
16 April 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6393487
23 October 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6293374
16 September 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6267790
5 September 2017
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6259542
3 August 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6240163
1 February 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6083589
18 January 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6072440
17 January 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6071932
22 September 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6006487
21 July 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5947738
18 July 2016
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5955978
7 December 2015
Examination of Repairs · In-Service Inspection · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5825303
25 November 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5770411
25 November 2015
Administrative Inspection · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5789248
18 November 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5776551
2 November 2015
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5755348
19 August 2014
ACP Annual Oversight · MARPOL Annex I Examination · DAPI Audit · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4959586
20 March 2014
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4820187
28 December 2011
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4216921
9 September 2011
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4158979
27 August 2011
Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4158978
22 February 2011
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3954897
8 February 2011
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3965792
11 January 2011
Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3925782
3 January 2011
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3924472
7 November 2010
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 4077240
23 October 2010
ACP COI Oversight
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 3862609
25 March 2010
Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3702903
11 December 2009
Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3653366
1 March 2009
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3542226
30 January 2009
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3397375
15 April 2008
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3184294
27 February 2008
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3154333
8 November 2007
Annual Inspection · MTSA/ISPS Verification
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3094940
5 July 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2984431
3 July 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2990696
22 June 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2970291
9 March 2007
ACP Periodic Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2885082
23 February 2007
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2876560
12 October 2006
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2798896
11 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2646288
27 March 2006
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2672896
9 November 2005
ACP COI Oversight
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2415381
14 September 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2492253
16 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2392320
11 April 2005
ACP Periodic Oversight
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2330763
7 February 2005
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2301805
8 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2216509
14 September 2004
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2195226
2 July 2004
MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 2118313
24 June 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2109149
31 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1980682
19 December 2003
Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1967291
21 October 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1932718
16 October 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1929789
7 October 2003
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1923118
31 May 2003
Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1830568
11 April 2002
Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1603553
1 March 2002
In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1601405
6 September 2001
Deficiency Check
Physical examination · Activities Europe · Activity 1071788
17 August 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1071118
16 June 2001
Deficiency Check
Physical examination · Activities Europe · Activity 1379467
7 April 2001
COI Inspection
Physical examination · Activities Europe · Activity 1439173
17 July 2000
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1051614
11 May 2000
Excursion Permit
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 818053
20 April 2000
Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1423357
22 March 2000
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1047841
25 February 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1372876
22 September 1999
Reflagging & Initial Certification · Initial Certification · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1390873
10 May 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1400983
10 October 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 12657
Fire Fighting › Fire Main › Material
Issued 15 June 2018
No resolution recorded
Fire main piping in way of the port pipe tunnel found with pinhole leaks. Replace wasted sections of the fire main piping to the satisfaction of class. SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 June 2018 — due date passed with no resolution recorded
Fire Fighting › Fire Main › Condition
Issued 4 May 2018
No resolution recorded
Fire main suction piping found with temporary repair. Replace the section of the fire main piping to the satisfaction of class. SOLAS 60 I/II.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Ventilators
Issued 26 April 2018
Resolved
The stbd bow bosn store natural ventilation ducting closure does not seal. Repair the closure so that it properly seals to the satisfaction of class. ICLL 66 Reg. 20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2018
Resolution: Received documentation from the attending ABS Surveyor, [name withheld] attesting to the full rectification of the deficiency; all sat.
Construction/Loadline › Structures › Scuttle
Issued 26 April 2018
Resolved
The aft dog for the bosn store hatch located on the bow does not effectively latch down. Replace the aft dog to the satisfaction of class. ICLL 66 Reg. 16
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2018
Resolution: Received documentation from the attending ABS Surveyor, [name withheld] attesting to the full rectification of the deficiency; all sat.
Construction/Loadline › Structures › Ventilators
Issued 26 April 2018
Resolved
The portside bow thruster intake vent is wasted. Repair the intake vent to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2018
Resolution: Received documentation from the attending ABS Surveyor, [name withheld] attesting to the full rectification of the deficiency; all sat.
Lifesaving › Lifeboat › Propulsion Engine
Issued 26 April 2018
No resolution recorded
Lifeboat number 1 will not start. Prove the proper operation of the number 1 lifeboat. The vessel is not authorized to carry more than 72 total persons until the number 1 lifeboat is fully functional to the satisfaction of class. SOLAS 60 III/4 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Abandon Ship
Issued 26 April 2018
No resolution recorded
Vessel was not fully crewed during inspection. Demonstrate crew's proficiency in firefighting, abandon ship drill, vessel control systems, and engineering upon activation to the satisfaction of [name withheld] 74 (2014) III/19
Action required: 17 - Rectify deficiencies prior to departure
Personnel › Certificates/Documents/Licenses › License, Master
Issued 26 April 2018
No resolution recorded
Provide crew's licenses and documetns, updated charts, and publications upon activation to the satisfaction of CGMI upon activation. 46 CFR 15, 33 CFR 164, SOLAS 74 (201) V
Action required: 17 - Rectify deficiencies prior to departure
Deck/Cargo › Holds/Tanks › Venitlation Fans
Issued 26 April 2018
No resolution recorded
Vent motor E-24 for cargo space not running, repair to the satisfaction of class. SOLAS 60 I/11
Action required: 701 - Prior to carriage of passengers/cargo
Deck/Cargo › Cargo Stowage › General
Issued 26 April 2018
No resolution recorded
Cargo gear sercuring fittings are corroded on the open upper deck aft of the flight deck, replace prior to carrying cargo on the open upper deck or provide amplifying documentation that the entire open upper deck cargo area has been decommissioned and that the Cargo Securing Manual has been updated accordingly to the satisfaction of the attending Marine Inspector. SOLAS 60 I/11
Action required: 705 - Other - as specified
Lifesaving › Launching Appliances › Winch
Issued 26 April 2018
Resolved
Port forward life boat davit winch limit switch wire brakets are disconnected and hanging unsupported. Repair to the satisfaction of the class. SOLAS 60 I/11
Action required: 705 - Other - as specified
Due 3 May 2018
Resolved 10 May 2018
Resolution: Received documentation from the attending ABS Surveyor, [name withheld] attesting to the full rectification of the deficiency; all sat.
Construction/Loadline › Structures › Air Pipe
Issued 26 April 2018
No resolution recorded
The following fuel tank vents were found to be wasted and must be repaired to the satisfaction of class,
a. Vent near fire station 47
b. #3 DB F/O vent
c. F/O tank 4C
SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 26 April 2018
No resolution recorded
Fuel tank vent 4C containment is wasted and has a hole. Repair the containment to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Air Pipe
Issued 26 April 2018
No resolution recorded
The 4 flight deck natural ventilation goose necks have corroded flanges and hardware, and 3 are missing gaskets. Repair to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 April 2018
No resolution recorded
The E-lighting fixture for 5-52-1 stairway is missings its cover and light bulb. Repair to the satisfaction of clas SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 April 2018
No resolution recorded
Electrical junction box missing cover for supply fan S-71 near exit 1-104-2. Replace the cover to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Deck Plating
Issued 26 April 2018
No resolution recorded
Descale and provide UT shots for vent access 4-68-2, tank vent access 4-159-2, and aft mid mooring station. To the satisfaction of class. SOLAS 60 I/11
Action required: 705 - Other - as specified
Due 26 June 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Ventilators
Issued 26 April 2018
No resolution recorded
Open for inspection the following spaces, fan enclosure 1-76-2, vent access 4-84-2, to the satisfaction of the attending Marine Inspector and Class. SOLAS 60 I/11
Action required: 705 - Other - as specified
Due 26 June 2018 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 26 April 2018
No resolution recorded
Deck toilet 4-76-2 has a hole in it and needs to be replaced. Replace the toilet to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Door
Issued 26 April 2018
No resolution recorded
Emergency egress door 1-104-2 needs to be adjusted, repair as necessary to the satisfaction of class. ICLL 66 Reg. 12.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 April 2018
No resolution recorded
Railings on the port aft flight deck level are damaged from shore tie cables, repair to original to the satisfaction of class. ICLL 66 Reg 25.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 26 April 2018
No resolution recorded
Update and submit for approval PSTP for incinerator. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 26 April 2018
Resolved
Replace J/W sensor for #3 SSDG to the satisfaction of class. SOLAS 60 I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2018
Resolved 10 May 2018
Resolution: Received documentation from the attending ABS Surveyor, [name withheld] attesting to the full rectification of the deficiency; all sat.
Fire Fighting › Means of Escape › Doorways
Issued 26 April 2018
Resolved
The self-closing door that serves passageway 5-43-1 is missing its closing device. Replace the doors self-closing device to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 10 May 2018
Resolution: Received documentation from the attending ABS Surveyor, [name withheld] attesting to the full rectification of the deficiency; all sat.
Fire Fighting › Fire Main › Condition
Issued 26 April 2018
No resolution recorded
Fire station 55's fire main piping is corroded. Descalge and conduct nondestructive testing to determine the remaining thickness of the corroded fire main piping or replace the corroded section of fire main piping to the satisfaction of class. SOLAS 60 II/55
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Lifesaving › Launching Appliances › Davit
Issued 26 April 2018
No resolution recorded
The port lifeboat davit control wires are pulling out of the control box and the port lifeboat contol mounting stand is wasted at its base. Repair the port lifeboat davit control box and mounting stand to the satisfaction of class. SOLAS 60 III/36
Action required: 705 - Other - as specified
Due 3 May 2018 — due date passed with no resolution recorded
Lifesaving › Launching Appliances › Davit
Issued 26 April 2018
No resolution recorded
All lifeboat davit wire runs are severely corroded. Replace the wire runs with in kind materials to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Lifesaving › Launching Appliances › Winch Brake
Issued 26 April 2018
No resolution recorded
Several remote winch brake control sheave tabs for the port and stbd lifeboat davits are corroded. Descale and conduct nondestructive testing to determine the remaining thickness of the corroded sheave tabs or replace the sheave tabs to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Door
Issued 26 April 2018
No resolution recorded
The stern ramps stbd hydraulic cylinder's bushing sleeve is worn. Determine the maximum bushing sleeve clearance for the stern ramps stbd hydraulic cyclinder to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Fire Fighting › Means of Escape › Doorways
Issued 26 April 2018
No resolution recorded
Emergency escape door 1-65-2 and the emergency escape door at frame 140 in hold 3 deck 1 are not sealing against the door seal gaskets. Repair the emergency escape doors so that the doors seal against the gaskets to the satisfaction of class. SOLAS 60 II/38 (d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Door
Issued 26 April 2018
No resolution recorded
The port and stbd bunker station water tight door coamings are corroded. Descale and conduct nondestructive testing to determine the remaining thickness of the corroded water tight door coamings to the satisfaction of class. ICLL 66 Reg. 21
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2018 — due date passed with no resolution recorded
Construction/Loadline › Structures › Door
Issued 26 April 2018
No resolution recorded
Two stbd bunker station water tight door hydraulic cylindeer hoses are not serviceable. Replace the hoses to the satisfaction of class. SOLAS 60 I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions › Ro-ro Cargo Spaces
Issued 26 April 2018
No resolution recorded
The cable penetration seal in the muli cable transit (MCT) for frame 65 in hold 4 has been damaged by new cable being run through the penetration. Repair the MCT with USCG/SOLAS approved fire rated cable penetration sealant to the satisfaction of class. SOLAS 60 II/38
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 26 April 2018
Resolved
The bow thruster ventilation fire damper closure hardware is difficult to close. Repalce the existing hardware with larger wingnuts to the satisfaction of class. SOLAS 60 II/47
Action required: 705 - Other - as specified
Due 3 May 2018
Resolved 10 May 2018
Resolution: Received documentation from the attending ABS Surveyor, [name withheld] attesting to the full rectification of the deficiency; all sat.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 26 April 2018
No resolution recorded
The forward 6 man life raft launching instructions are damaged, there is no emergency lighting for launching instructions, and this no means of embarkation. Replace the damaged instructions and install emergency lighting for the launching instructions and install a means of embarkation to the satisfaction of class. SOLAS 74 III/9 and SOLAS 74 III/11.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018 — due date passed with no resolution recorded
Lifesaving › Lifeboat Equipment › Searchlight
Issued 26 April 2018
Resolved
Lifeboat number 2's searchlight handle is rotted and non-serviceable. Repair or replace the searchlight's rotted handle to the satisfaction of class. SOLAS 74 III/31.1.1.1 LSA code 4.4.8.29
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 10 May 2018
Resolution: Received documentation from the attending ABS Surveyor, [name withheld] attesting to the full rectification of the deficiency; all sat.
Electrical › Electric Generation Source (emergency) › Generator
Issued 26 April 2018
Resolved
The Emergency Diesel Generator did not start and connect to the emergency switchboard as required by the ABS ACP US Supplement. Demonstrate the proper operation of the Emergency Diesel Generator. ABS 4-8-2/3/11
Action required: 10 - Deficiency Rectified
Due 26 April 2018
Resolved 26 April 2018
Resolution: The attending USCG MI witnessed the proper operation of the emergency diesel generator.
Lifesaving › Lifeboat › Propulsion Engine
Issued 26 April 2018
Resolved
Lifeboat number 3's fuel filter bowl is leaking fuel excessively. Repair the fuel filter and prove the proper operation of the lifeboat. SOLAS 60 III/4 (a)
Action required: 10 - Deficiency Rectified
Due 26 April 2018
Resolved 26 April 2018
Resolution: The attending USCG Marine Inspector witnessed the proper operation of the #3 lifeboat's fuel system.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 April 2018
Resolved
The starboard life raft launching station and staboard lifeboat launching stations aft emergency lighting does not work. Repair the lighting to the satisfaction of class. SOLAS 74 III/9.2.2
Action required: 10 - Deficiency Rectified
Due 26 April 2018
Resolved 26 April 2018
Resolution: The attending USCG Marine Inspector witnessed the proper operation of the starboard life raft launching station and starboard lifeboat aft emergency lights.
Lifesaving › Lifebuoys › Serviceable
Issued 26 April 2018
Resolved
8 ring bouys have a hole in them and require repairs. SOLAS 60 I/11
Action required: 10 - Deficiency Rectified
Due 26 April 2018
Resolved 26 April 2018
Resolution: The attending USCG Marine Inspectors verifed that all 8 ring bouys had been repaired using the manufacturers approved repair procedures.
Engineering › Bilge Water Management System › Piping
Issued 16 April 2018
No resolution recorded
Bilge unable to take suction from engine room and three cargo holds due to holes in bilge piping. Repair bilge piping in kind and prove the proper operation of the vessel's bilge system to the satisfaction of the attending Classification Society prior to vessel's departure. SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2018 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Pump
Issued 16 September 2017
Resolved
Vessel's main propulsion system is not fully operational. Fuel system is not providing sufficient pressure to the engine resulting in vessel's reduced engine HP output & subsequent reduced maneuverability. Vessel is required to have standby tugs of aggregate HP no less than 5000HP to meet vessel at pilot station and escort vessel to it's birth at CSX.
Action required: 705 - Other - as specified
Due 16 September 2017
Resolved 16 September 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 17 January 2017
Resolved
CO2 agent from low-pressure fire extinguishing system is leaking due to unknown causes. Identify cause(s) of the leak and make repairs under the direction of and to satisfaction of an attending surveyor from the American Bureau of Shipping. Ensure liquid CO2 level is in accordance with SOLAS requirements, to the satisfaction of the attending ABS surveyor. (SOLAS'60 II/65). PRIOR TO SAILING
Action required: 705 - Other - as specified
Due 17 January 2017
Resolved 6 September 2017
Resolution: LPCO2 system was certified by HILLER Systems and documentation was provided to attendning USCG Marine Inspectors and ABS Class Surveyor.
Electrical › Lighting (service) › Conductor
Issued 29 March 2016
Resolved
The 440 VAC safety and security light fixture on the port side aft main deck (aft mooring equipment area) is completely broken from its mount and held up right by rope. Make permanent repairs as necessary for safety and security of crew and vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2016
Operations/Management › Vessel Activity › Construction/Repair
Issued 29 March 2016
Resolved
Of all items that will be on final Decommissioning list letter to USCG and ABS, ensure all systems are removed from vessel as feasible, cleared of all hazardous materials and oils, electrically disconnected, and marked as decommissioned.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2016
Resolution: Items corrected before sea trials.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 29 March 2016
Resolved
The proximity switch located near the MDE flywheel is unmounted. Remount switch and ensure its operational is as designed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2016
Fire Fighting › Fire Hydrants › Condition
Issued 29 March 2016
Resolved
Fire station #15 fire plug valve may be leaking as indicated by a partially charged fire hose. Ensure fire station is functioning as designed.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 21 April 2016
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 29 March 2016
Resolved
Place either breakers or breaker blanks in the open spots located within the DB-3 (light) panel iwo Hold 3 Deck 2.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 13 July 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 March 2016
Resolved
Ensure the cardiac defibrillator device in the engineering space (electrical distribution panel room) is serviceable iaw with manufacturer’s instruction. The pads expired in June 2015. Additionally, properly mount the device.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 21 April 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 29 March 2016
Resolved
Make repairs to the 110 volt outlet located directed under the 220 transformer in the Hold 3 Deck 2 escape trunk. The outlet conduit connection is not adequately mounted and presents a hazard.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 2 May 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 29 March 2016
Resolved
Make permanent repairs to damaged/bent CO2 line adjacent to purifier room.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 1 June 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 March 2016
Resolved
The electrical box located in overheard at Hold 3 Deck 3 iwo frame 130/centerline has a temporary fastening device holding the cover on. Make repairs that affect the use of the appropriate fasteners for box.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 2 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2016
Resolved
Remove dead wires iwo two locations 1) aft of bow thruster motor 2) immediately under hatch near bow thruster.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 17 June 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 29 March 2016
Resolved
Remove or make adequate repairs as necessary to the DECOM Locker communication system iwo 6-37-2 (Decom locker). The mounted speaker and push notification switch are severely corroded, falling down, and open to the elements on open deck.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 17 June 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 March 2016
Resolved
The shore tie connection junction box for the #1 life boat is severely corroded and must to be checked for electrical hazards and adequately remounted. Ensure the same repair is made for all other life boats as well which are in similar condition.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 1 June 2016
Lifesaving › Launching Appliances › Davit
Issued 29 March 2016
Resolved
The limit switch mounting foundations iwo the life boat launching arms are heavily corroded. Ensure that the limit switches are adequately mounted and will consequently work as designed in all situations including future adjustments.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 21 April 2016
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 March 2016
Resolved
Repair the HPW leak in the space above main deck restroom located at 4-76-2. The vertical piping is permeated and leaving 2”-3” of standing water on the deck at all times.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 21 April 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 29 March 2016
Resolved
Properly mount the light fixtures iwo the following locations: 1) port side life access ladder space, 2) Hold a Deck 4/MCCI Room.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 1 June 2016
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 29 March 2016
Resolved
Ensure that the advanced corrosion on sludge tank containment is not enough to jeopardize proper pollution prevention in case of an overflow. Conduct necessary testing, corrective and preventative maintenance as necessary.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 1 June 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 29 March 2016
Resolved
Remove or replace damaged/exposed overhead light in the WPNS (2-96-0) storage area iwo Hold 4 Deck 2, and 2) Hold 4 Deck 4 iwo frame 104. The frame 104 light appears to have caught fire at one point and could still be a safety/electrical hazard.
Condition: Improper/Lack of Maintenance
Due 29 April 2016
Resolved 1 June 2016
Electrical › Electric Generation Source (service) › Generator
Issued 29 February 2016
Resolved
Three SS diesel generators (of four) all have temporarily installed ventilation fans in the vicinity of the generator bearing areas. Determine reason for this fan installation with a running test and provide assessment of any repairs necessary to generator and/or proper fan installation as per plan review. If fans are needed, ensure they are appropriately wired iaw CFR/Class rules/plans
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2016
Resolved 21 April 2016
Engineering › Steam System (auxiliary) › Valve
Issued 29 February 2016
Resolved
There are two steam valves in lower engine room leaking iwo the supply and for the main engine L/O Sump Tank. Valves are currently un-insulated as well. Make permanent repairs to remove all steam leaks before any using steam valves to M/E l/o sump. Full temp test pends.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2016
Resolved 21 April 2016
Electrical › Electric Supply System (service) › Cable
Issued 29 February 2016
Resolved
There are two separate locations where the ROXTEC stuffing boxes have unauthorized (red) filler glands: 1) Exit door iwo 1-104-1 and 2) starboard main stairwell up to accommodation spaces. Make necessary replacement of authorized ROXTEC filler glands.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 June 2016
Electrical › Electric Supply System (service) › Transformer
Issued 29 February 2016
Resolved
The small steel deck table support where the VT8 transformer rests (in immediate vicinity of the VT8 -breaker panel) has severe corrosion to the outboard stanchion legs. The table dropped a ½’ to 1” when it was stepped on. Make permanent repair to the table so that it correctly supports the transformer in all sea states.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2016
Electrical › Lighting (service) › Conductor
Issued 29 February 2016
Resolved
Two deck lights iwo deck 4 (mounted on house) are jury rigged with an electrical tape repair. Make permanent repairs to conductor wire to remove jury rigging and electrical hazard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 1 June 2016
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 29 February 2016
Resolved
Remove the Red Devil blower exhauster the BOSUN Hold that is welded to the overhead and electrically hardwired. This blower is not designed (to include flexible ducting) for permanent installations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 February 2016
Resolved
The port and starboard navigational light foundations (within the screen area) are painted with gloss white and grey paint. Paint them to a finish of matt black as required to prevent proper arc of visibility. Ensure all shipboard navigational light screens are not in similar condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2016
Deck/Cargo › Cargo Stowage › General
Issued 29 February 2016
Resolved
The deck container storage stanchions, D-rings, and container locking sockets on main cargo decks are severely corroded and may not be suitable for safe container storage. Conduct risk assessment and suitable testing expected to simulate static and dynamic forces during any voyage to ensure these stanchions are ready for safe cargo securing use.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2016
Resolution: See scanned document from OIC of vesssel for non-use of these fittings.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 February 2016
Resolved
The wood blocks for the heavy cargo deck crane rests iwo of the garage top deck appear to be loose and/or broken and could cause severe injury to deck personnel if they were to fall. Ensure heavy wood blocks are fasted to the rest and will not fall and crane is adequately supported during rested position.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2016
Electrical › Electrical Distribution System (service) › Conductor
Issued 29 February 2016
Resolved
The conductor wire conduit (vertical running) for the flight deck visual landing aid lighting is falling down due to extreme wastage of the hold down fasteners. Make repairs to either install exposable wires or properly secure current cable installation with existing conduit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 1 June 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 February 2016
Resolved
The Rescue davit (on decom list) access ladder is severely wasted and unsafe for crew usage. Make repairs as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 23 December 2016
Resolution: Vsl P/E and CEng had ladder blanked off to prevent crew usage. According to P/E, ladder will be repaired when fundage is someday available. P/E also states that shore tie cables will be on the stbd side of vessel not on RB davit platform at new moorings.
Fire Fighting › Fire Main › Material
Issued 25 November 2015
Resolved
Make permanent repairs to Fire Main pump piping in way of 2.5 inch pipe in AMR and 5 inch pipe in way of fuel station. Prove proper operation of Fire Main System onboard the vessel to the satisfaction of CG Marine Inspector or ABS Class Surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2015
Resolution: Repairs completed and system tested to ABS satisfaction.
Lifesaving › Lifeboat › Markings
Issued 19 August 2014
Resolved
replace retro tape on outboard side of port side lifeboats
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2015
Resolution: Notified ABS vessel in drydock.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 19 August 2014
Resolved
Loop Seal hose on Air Box to MDE Chaffed need replacing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2015
Resolution: Notified ABS vessel in drydock.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 19 August 2014
Resolved
Found fault 3 each on Fixed detection panel
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2015
Resolution: Notified ABS vessel in drydock.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 19 August 2014
Resolved
Complete Qtr update in SOPEP
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2014
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 13 January 2011
Resolved
Received notification that while the Chief Engineer was performing maintenance on the rescue boat winch the wire got kinked and two strands broke.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 February 2011
Resolved 22 February 2011
Resolution: Replaced wire and conducted a weight test to the satisfaction of Coast Guard and the attending ABS surveyor.
Electrical › Electrical Distribution System (service) › Cable
Issued 23 October 2010
Resolved
Remove spliced cable in electrician shop
Action required: 705 - Other - as specified
Resolved 1 November 2010
Resolution: cleared by ACP ACS
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 23 October 2010
Resolved
Clean generator room bilge
Action required: 705 - Other - as specified
Resolved 1 November 2010
Resolution: cleared by ACP ACS
Stability › Watertight Integrity › General
Issued 23 October 2010
Resolved
Replace gasket on purifier room door
Action required: 705 - Other - as specified
Resolved 1 November 2010
Resolution: cleared by ACP ACS
Lifesaving › Inflatable Liferafts › Servicing
Issued 23 October 2010
Resolved
Provide ILR for total number of persons onboard. Vessel currently has all 12 ILR out for servicing.
Action required: 705 - Other - as specified
Resolved 1 November 2010
Resolution: cleared by ACP ACS
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 23 October 2010
Resolved
Repair/replace #4 SSDG reverse power relay
Action required: 705 - Other - as specified
Resolved 1 November 2010
Resolution: cleared by ACP ACS
Electrical › Electrical Distribution System (service) › Switchboard
Issued 23 October 2010
Resolved
Troubleshoot offline generator issue with light system. Control room lights are effected when vessel is on emergency power and an offline generator is started or shutdown. Vsl crew stated that the design of the system is as stated above.
Action required: 705 - Other - as specified
Resolved 1 November 2010
Resolution: Requirement was issue as a outstanding class requirement. Inputted in MISLE for documentation purposes.
Lifesaving › Line-Throwing Appliances › Lines
Issued 23 October 2010
Resolved
Provide 4 line throwing appliances with current expiration dates.
Action required: 705 - Other - as specified
Resolved 1 November 2010
Resolution: cleared by ACP ACS
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 23 October 2010
Resolved
Update FCP to include fire door symbols in legend.
Action required: 705 - Other - as specified
Resolved 7 July 2016
Resolution: Crew updated plan and ABS reviewed.
Lifesaving › Launching Appliances › Davit
Issued 30 January 2009
Resolved
Repair NO.3 L/B limiter switch to satisfaction of class or the OCMI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2009
Resolved 2 February 2009
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 27 February 2008
Resolved
Inoperable Echo Depth Sounding Device.
Action required: 705 - Other - as specified
Due 26 March 2008
Resolved 4 March 2008
Resolution: Received e-mail stating D/S was repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 3 July 2007
Resolved
Start air valve on #1 cylinder not seating. Repair or replace valve and demonstrate proper operation of the start air system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2007
Resolved 3 July 2007
Resolution: ABS report stating that the system is operation properly.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 19 December 2003
Resolved
Vessel can drop, but can not recover either anchor. Vessel got water in the forecastle, which made the anchor winches inoperative.
Action required: 705 - Other - as specified
Due 2 July 2004
Resolved 2 July 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 31 May 2003
Resolved
1. Make permanent repairs to level gauge on Low Pressure CO2 fixed fire fighting system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 May 2003
Resolution: Left issue to be corrected by Class.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 31 May 2003
Resolved
2. Obtain proper endorsement on SOLAS Safety Radio statement of Voluntary Compliance and remove the SOLAS certificate.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 31 May 2003
Resolution: Left issued to be corrected by class.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 31 May 2003
Resolved
3. Employ proper means to embark life raft located on the bow of the vessel
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 May 2003
Resolution: Left issue to be resolved by class.
Lifesaving › Lifeboat
Issued 11 April 2002
Resolved
DEMONSTRATE PROPER OPERATION OF #1 LIFEBOAT ENGINE, WILL NOT START. LEGACY COMPONENT DESC: Propulsion Starting System
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 April 2002
Navigation › Collision/Grounding Avoidance
Issued 11 April 2002
Resolved
DEMONSTRATE OPERATION OF BOTH RADARS. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 April 2002
Electrical › Electric Generation Source (emergency)
Issued 11 April 2002
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY GENERATOR AUTO BUSS TRANSFER . LEGACY COMPONENT DESC: Switch
Condition: Unknown
Due 15 April 2002
Resolved 15 April 2002
Lifesaving › Lifebuoys
Issued 11 April 2002
Resolved
RELOCATE SPEAKERS P/S SIDES TO ALLOW FOR PROPER FREE FALL DEPLOYEMENT OF BRIDGE WING LIFEBUOY WITH ATTACHED LIGHT AND SMOKE SIGNAL. LEGACY COMPONENT DESC: Stowage
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 April 2002
Resolved 16 April 2002
Resolution: Relocated speakers.
Fire Fighting › Ventilation Systems
Issued 11 April 2002
Resolved
THREE E/R VENT DAMPNERS INOPERABLE AND DO NOT CLOSE PROPERLY. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 30 April 2002
Resolved 16 April 2002
Deck/Cargo › Cargo Stowage
Issued 1 March 2002
Resolved
Containers stowed adjacent to class one explosives not in accordance with ABS approved Cargo Securing Manual.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2002
Resolution: RECIEVED APPROVAL LETTER FROM ABS FO RTHE CARGO SECURING MANUAL, CGI DRAWING NO. 2425-C-001 ALT.B
Unknown
Issued 7 April 2001
Resolved
Duct seal used as cable penetration fire stops. Restore all cable penetration fire stops as original in accordance with approved structural fire protection plan.
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Unknown
Issued 7 April 2001
Resolved
Provide adequate lighting for liferaft launching area IAW 46CFR 111.75-16, 46CFR199.110, 112.15-1(g).
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Unknown
Issued 7 April 2001
Resolved
Repair broken door for provision store room 5-46-3.
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Unknown
Issued 7 April 2001
Resolved
Identify and properly label all emergency lights. Renew burned out and nonoperational emergency lights including escape trunk 1-140-1, IAW 46CFR 97.37-25.
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Unknown
Issued 7 April 2001
Resolved
Repair water leak in room 6-62-8. Repair non operational toilet in room 5-62-9.
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Unknown
Issued 7 April 2001
Resolved
Properly repair flame screen port side fuel oil vent 0-104-2.
Condition: Unknown
Due 7 April 2001
Resolved 7 April 2001
Engineering
Issued 22 September 1999
Resolved
RETEST ALL MAIN DIESEL ENGINE ALARMS/SHUT-DOWNS UPON COMPLETION OF ENGINE OVERHAUL AND PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 22 October 1999
Resolved 18 October 1999
Fire Fighting
Issued 22 September 1999
Resolved
PROVE PROPER OPERATION OF HIGH PRESSURE CO2 SYSTEM VENT SHUT-DOWN PRESSURE SWITCH FOR BOILER/INCINERATOR ROOM; SWITCH CURRENTLY TIES INTO ENGINEROOM VENT MOTORS. THIS REQUIREMENT TO BE COMPLETED PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Documentation
Issued 22 September 1999
Resolved
NOTIFY THE VESSEL DOCUMENTATION CENTER TO HAVE THE CERTIFICATE OF DOCUMENTATION REISSUED WITH THE CORRECT VESSEL NAME PRIOR TO CARRIAGE OF CARGO.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Lifesaving
Issued 22 September 1999
Resolved
INSTALL 1 ADDITIONAL SEAT HARNESS IN LIFEBOATS NO. 1, 2, 3, AND 4; LIFEBOATS ARE RESTRICTED TO 71 PERSONS UNTIL REQUIREMENT IS MET.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Accommodation/Occupational Safety
Issued 22 September 1999
Resolved
RENEW WASTED NATURAL VENTILATION SCREENS IN WAY OF STACK AFT BULKHEAD FOR MAIN ENGINE AND SSDG CRANKCASE VENTS.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Electrical
Issued 22 September 1999
Resolved
INSTALL 1 LIGHT FIXTURE OFF THE EMERGENCY LIGHTING CIRCUIT IN THE LOWER LEVEL STARBOARD SIDE OF THE FORWARD DAMAGE CONTROL LOCKER.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Navigation
Issued 22 September 1999
Resolved
CONDUCT AN OPERATIONAL TEST OF STEERING SYSTEM UPON COMPLETION OF OVERHAUL AND PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 22 October 1999
Resolved 18 October 1999
Construction/Loadline
Issued 22 September 1999
Resolved
REPAIR SMALL WASTAGE HOLE IN THE STACK AFT BULKHEAD DECK 6 IN WAY_x001C_ OF Q.A. HATCH.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Documentation
Issued 22 September 1999
Resolved
PROVIDE AND POST A U.S. CAOST GUARD APPROVED FIRE AND SAFETY PLAN WHICH REFLECTS THE MODIFICATIONS MADE TO THE AMMO STORAGE DECK.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Lifesaving
Issued 22 September 1999
Resolved
FREE-UP FROZEN DRAIN PLUGS IN 4 LIFEBOATS.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Accommodation/Occupational Safety
Issued 22 September 1999
Resolved
REPAIR OR RENEW VENTILATION DUCTING ABOVE MSD.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Lifesaving
Issued 22 September 1999
Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO VESSEL DEPARTURE FROM PORT OF JACKSONVILLE.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Documentation
Issued 22 September 1999
Resolved
PROVIDE AN APPROVED CAPACITY PLAN FOR THE VESSEL.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 22 September 1999
Resolved
REPAIR OIL LEAKS AT THE FOLLOWING HYDRAULICALLY OPERATED WATERTIGHT DOORS:_x001C_1. DECK 2 FRAME 104 STARBOARD SIDE_x001C_ 2. DECK 2B FRAME 104 STARBOARD SIDE_x001C_ 3. DECK 1 FRAME 166 PORT SIDE
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 22 September 1999
Resolved
INSTALL FILLER PLATE AT DECK IN WAY OF INBOARD BULKHEAD DECK 3B WHERE TRANSVERSE BEAMS PENETRATE BULKHEAD.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Accommodation/Occupational Safety
Issued 22 September 1999
Resolved
REPAIR WASTAGE HOLE TO FOC'SLE STARBOARD WINCH VENT ENCLOSURE BOX AND INSTALL NEW GASKET ON DOOR COVER.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Fire Fighting
Issued 22 September 1999
Resolved
PROVIDE A MINIMUM OF 4 COMPLETE FIREMAN OUTFITS PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Deck/Cargo
Issued 22 September 1999
Resolved
PROVE PROPER OPERATION OF REMOTE VENT SHUT-DOWN FOR VENT MOTOR LOCATED ON 4TH DECK STARBOARD SIDE, 3RD FROM AFT BULKHEAD.
Condition: Unknown
Due 22 October 1999
Resolved 18 October 1999
Lifesaving
Issued 22 September 1999
Resolved
PROVE PROPER OPERATION OF LIFEBOAT SEARCHLIGHTS PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Documentation
Issued 22 September 1999
Resolved
PROVIDE AND POST AN APPROVED GENERAL ARRANGEMENTS PLAN FOR THE VESSEL.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Documentation
Issued 22 September 1999
Resolved
PROVIDE AN APPROVED TRIM AND STABILITY BOOK AND DAMAGE STABILITY BOOKLET PRIOR TO OPERATION OF THE VESSEL .
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Lifesaving
Issued 22 September 1999
Resolved
PROVIDE RAIL AROUND PORT AND STARBOARD LIFEBOAT WINCH MOTOR CONTROLLER SWITCHES OR RELOCATE BEHIND EXISTING RAIL PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Documentation
Issued 22 September 1999
Resolved
PROVIDE UPDATED COPY OF VESSEL'S CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 29 December 1999
Resolved 29 December 1999
Electrical
Issued 22 September 1999
Resolved
CONDUCT TEST ON SHORE POWER PHASE INTERLOCK SYSTEM.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Engineering
Issued 22 September 1999
Resolved
INSTALL REMOTE SHUT-OFF MECHANISMS FOR THE TWO ENGINEROOM SLUDGE TANK VALVES.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Engineering
Issued 22 September 1999
Resolved
REFIT LOWER WASTE HEAT BOILER CIRCULATING PUMP.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Documentation
Issued 22 September 1999
Resolved
PROVIDE A COPY OF VESSEL'S OIL TRANSFER PROCEDURES FOR REVIEW PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 22 September 1999
Resolved
PROVE PROPER OPERATION OF BOW THRUSTER AND 4 PIPE TUNNEL BILGE SYSTEM SUCTIONS.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 22 September 1999
Resolved
PROVIDE GASKET ON THE AFT DAMAGE CONTROL LOCKER ENTRANCE DOOR FRAME.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Documentation
Issued 22 September 1999
Resolved
PROVIDE A "STATEMENT OF FACT" FROM CLASS SOCIETY PRIOR TO OPERATION OF VESSEL.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Electrical
Issued 22 September 1999
Resolved
PROVE PROPER OPERATION OF LIGHT FIXTURE IN DECK LOCKER 9-54-4.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Lifesaving
Issued 22 September 1999
Resolved
PROVIDE OPERATING INSTRUCTIONS FOR HYDRAULIC MAST LOWERING SYSTEM.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Accommodation/Occupational Safety
Issued 22 September 1999
Resolved
REWELD BROKEN LOWER RAIL COURSE ON PORT-FORWARD CORNER OF UPPER KING POST DECK.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999
Construction/Loadline
Issued 22 September 1999
Resolved
REPAIR WASTAGE HOLES NOTED BY UPPER KING POST AREA PORT SIDE; ONE ON AFT BULKHEAD AND ONE THE HATCH COMBING.
Condition: Unknown
Due 29 September 1999
Resolved 29 September 1999