MAURY USCG vessel records
← All vessels

CAPE MAY

CAPE MAY is a 1972 freight ship. The Coast Guard has recorded 11 inspections since 2017, most recently in August 2021, along with 14 deficiencies and 3 casualty investigations between 2010 and 2021.

Records from 2010 to 2021. Most recent: inspection, 3 August 2021.

Built
1972
Last inspected
3 August 2021
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 August 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7205958
Flag
UNITED STATES
Maury page id
psix-47051

Documentation record

Registered dimensions (L × B × D)725.0 ft × 106.0 ft × 39.0 ft
Registered tonnagegross 21,667 / net 12,128
ITC dimensions (L × B × D)824.2 ft × 105.8 ft × 53.6 ft
ITC tonnagegross 47,674 / net 15,662
BuilderGENERAL DYNAMICS QUINCY · QUINCY, MA, UNITED STATES · built 1972
Hull materialSteel
PropulsionSteam Turbine
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21667 - Regulatory (Subpart C or D), Gross Ton
47674 - Convention (Subpart B), Gross Ton
12128 - Regulatory (Subpart C or D), Net Ton
38370 - Dead Weight, Ton
55660 - Displacement, Ton
15662 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 11

3 August 2021 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7283568
5 November 2020 Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7088892
28 January 2020 ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6897613
12 September 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6810354
17 March 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6649307
13 February 2019 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6625653
23 January 2019 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6613123
30 November 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6324266
2 November 2017 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6298180
13 March 2017 ACP COI Oversight · Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6104028
25 January 2017 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6079506

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 November 2020 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed at sea safely. Ships main fire pump shaft bearing failed. 74 SOLAS (14) I/11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 10 November 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 November 2020 Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed at sea safely. Cable transits above bridge on stbd side to antenna and below the mast to the outlet need to be renewed. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 10 November 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 January 2020 Resolved
Suitable arrangements shall be made for embarkation into the lifeboats and shall include means for illumination for launching and water. Vessel starboard embarkation light extinguished. Solas 60 III Reg 19aii
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 5 February 2020
Resolution: ABS Report #4120018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 January 2020 Resolved
In all classes of WTD indicators shall be fitted which show whether the doors are open or closed. Indicator light at operating station for open not visible. Solas 60 II 113fv
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2020
Resolved 5 February 2020
Resolution: ABS Report #4120018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2019 Resolved
Exposed parts of pipes to ballast and other tanks that extend above the freeboard deck shall be of substantial construction. Emergency generator fuel tank vent pipe corroded and cracked. ICLL 66 Annex I/20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2019
Resolved 13 February 2019
Resolution: Received documentation for ABS Surveyor [name withheld] attesting to the clearing of the deficiency; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 January 2019 Resolved
No changes shall be made in the structural arrangements, machinery equipment, and other items covered by a survey. Smoke extraction detection system shows an error and has no audible alarm. SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2019
Resolved 13 February 2019
Resolution: Received documentation for ABS Surveyor [name withheld] attesting to the clearing of the deficiency; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2019 Resolved
Machinery space openings shal be properly framed and efficiently enclosed by steel with opeings fitted with covers complying with regulation 12(1). Engine compartment port side stack vent plenum's weathertight closure is corroded. ICLL 66 Annex I/17(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2019
Resolved 13 February 2019
Resolution: Received documentation for ABS Surveyor [name withheld] attesting to the clearing of the deficiency; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 23 January 2019 Resolved
Suitable arrangements shall also be made for embarkation into the liferafts, which shall include sufficient ladders to facilitate embarkation into the liferafts when waterborne... The Administration may permit the replacement of some or all of such ladders by approved devices. The Port and Starboard aft liferafts do not have suitable embarkation arrangements when the liferafts are waterborne. Provide a proposal to comply with suitable arrangements for embarkation of the Port and Starboard aft liferafts to the satisfaction of Class and the attending USCG Marine Inspector. SOLAS 60 III/19(b)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 March 2019
Resolution: Embarkation arrangements for liferafts when waterborne revised an captured in activity #6298180.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 14 November 2017 Resolved
Upon activation, vessel is to provide MMCs for all crew members when vessel is fully crewed IAW COI Manning to a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 March 2019
Resolution: Inspected MMCs in accordance with COI manning requirements, including TWIC cards; all sat.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 November 2017 Resolved
Vessel does not keep up to date charts and publications due to ROS status. Vessel must provide charts and publications to USCG Marine Inspector for inspection prior to getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2019
Resolution: Vessel provided updated charts and publications to the satisfaction of the attending Marine Inspector.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 14 November 2017 Resolved
Vessel is to conduct abandon ship, fire and security drill to the satisfaction of the USCG Marine Inspector prior to getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 March 2019
Resolution: Vessel conducted satisfoactory fire, abandon ship and security drills in the pressence of the Marine Inspector.
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 14 November 2017 Resolved
Provide satisfactory report of repairs to foam tank to class surveyor.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 30 November 2017
Resolution: Cleared to the satisfaction of the class surveyor, provided report.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 14 November 2017 Resolved
Demonstrate proper operation of the engineer alarm panel to the satisfaction of the class surveyor.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 30 November 2017
Resolution: Cleared to the satisfaction of the class surveyor. Provided report.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 14 November 2017 Resolved
Provide proposal to comply with sufficient arrangements for embarkation to liferafts to the class surveyor and attending USCG MI.
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 30 November 2017
Resolution: ABS report #3420208

Casualty record · 3

5 March 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3695006
28 August 2012Routine · role: Involved in a Marine Casualty · activity 4426348
3 August 2021Routine · role: Acknowledged Pollution Source · activity 7283568
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.