CAPE MAY is a 1972 freight ship. The Coast Guard has recorded 11 inspections since 2017, most recently in August 2021, along with 14 deficiencies and 3 casualty investigations between 2010 and 2021.
Records from 2010 to 2021. Most recent: inspection, 3 August 2021.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 13 February 2026 · expires 28 February 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21667 - Regulatory (Subpart C or D), Gross Ton 47674 - Convention (Subpart B), Gross Ton 12128 - Regulatory (Subpart C or D), Net Ton 38370 - Dead Weight, Ton 55660 - Displacement, Ton 15662 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 November 2020Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed at sea safely. Ships main fire pump shaft bearing failed. 74 SOLAS (14) I/11
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 November 2020
Resolved 10 November 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 November 2020Resolved
The condition of the ship and its equipment shall be maintained to ensure the ship will remain fit to proceed at sea safely. Cable transits above bridge on stbd side to antenna and below the mast to the outlet need to be renewed. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2020
Resolved 10 November 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 January 2020Resolved
Suitable arrangements shall be made for embarkation into the lifeboats and shall include means for illumination for launching and water. Vessel starboard embarkation light extinguished.
Solas 60 III Reg 19aii
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 5 February 2020
Resolution: ABS Report #4120018
In all classes of WTD indicators shall be fitted which show whether the doors are open or closed. Indicator light at operating station for open not visible.
Solas 60 II 113fv
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2020
Resolved 5 February 2020
Resolution: ABS Report #4120018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2019Resolved
Exposed parts of pipes to ballast and other tanks that extend above the freeboard deck shall be of substantial construction. Emergency generator fuel tank vent pipe corroded and cracked.
ICLL 66 Annex I/20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2019
Resolved 13 February 2019
Resolution: Received documentation for ABS Surveyor [name withheld] attesting to the clearing of the deficiency; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 January 2019Resolved
No changes shall be made in the structural arrangements, machinery equipment, and other items covered by a survey. Smoke extraction detection system shows an error and has no audible alarm.
SOLAS 60 I/11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2019
Resolved 13 February 2019
Resolution: Received documentation for ABS Surveyor [name withheld] attesting to the clearing of the deficiency; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2019Resolved
Machinery space openings shal be properly framed and efficiently enclosed by steel with opeings fitted with covers complying with regulation 12(1). Engine compartment port side stack vent plenum's weathertight closure is corroded.
ICLL 66 Annex I/17(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2019
Resolved 13 February 2019
Resolution: Received documentation for ABS Surveyor [name withheld] attesting to the clearing of the deficiency; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 23 January 2019Resolved
Suitable arrangements shall also be made for embarkation into the liferafts, which shall include sufficient ladders to facilitate embarkation into the liferafts when waterborne... The Administration may permit the replacement of some or all of such ladders by approved devices. The Port and Starboard aft liferafts do not have suitable embarkation arrangements when the liferafts are waterborne. Provide a proposal to comply with suitable arrangements for embarkation of the Port and Starboard aft liferafts to the satisfaction of Class and the attending USCG Marine Inspector.
SOLAS 60 III/19(b)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 March 2019
Resolution: Embarkation arrangements for liferafts when waterborne revised an captured in activity #6298180.
Upon activation, vessel is to provide MMCs for all crew members when vessel is fully crewed IAW COI Manning to a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 March 2019
Resolution: Inspected MMCs in accordance with COI manning requirements, including TWIC cards; all sat.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 14 November 2017Resolved
Vessel does not keep up to date charts and publications due to ROS status. Vessel must provide charts and publications to USCG Marine Inspector for inspection prior to getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2019
Resolution: Vessel provided updated charts and publications to the satisfaction of the attending Marine Inspector.
Vessel is to conduct abandon ship, fire and security drill to the satisfaction of the USCG Marine Inspector prior to getting underway.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 March 2019
Resolution: Vessel conducted satisfoactory fire, abandon ship and security drills in the pressence of the Marine Inspector.
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 14 November 2017Resolved
Provide satisfactory report of repairs to foam tank to class surveyor.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 30 November 2017
Resolution: Cleared to the satisfaction of the class surveyor, provided report.
Demonstrate proper operation of the engineer alarm panel to the satisfaction of the class surveyor.
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 30 November 2017
Resolution: Cleared to the satisfaction of the class surveyor. Provided report.
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.