Records from 2016 to 2025. Most recent: inspection, 25 June 2025.
Inspection history · 17
25 June 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8168323
28 January 2025
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8071235
22 May 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7921834
23 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694773
8 March 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7408335
3 February 2022
Hull Examination · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7386735
1 June 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7211915
16 June 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6978317
8 May 2019
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6679562
29 September 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6552801
22 March 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6376074
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360489
13 March 2017
Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6100756
20 January 2017
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6084382
12 January 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6070191
23 August 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5986811
11 April 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5851335
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 June 2025
Resolved
At each inspection for certification...the bilges and other spaces may be examined to see that there is no excessive accumulation of oil…that might create a fire hazard... Marine Inspector observed a lubricating oil leak on the starboard main diesel engine that was actively dripping down the engine block and associated components and into the bilge.
46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 6 August 2025
Resolution: O/O replaced oil sensor on main engine block.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 June 2025
Resolved
Electrical equipment on a vessel must be installed...to protect passengers, crew, other persons, and the vessel from electrical hazards...caused by or originating in electrical equipment, and electrical shock. Marine Inspector observed unprotected wiring splices (missing wire conductors) installed on the potable water transfer pump in the tank hold space.
46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 22 August 2025
Resolution: Crew replaced wiring for potable water pump.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2025
Resolved
The owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment including the following: Testing of each firehose to a test pressure equivalent to its maximum service pressure; Firehose on upper deck aft of cabin was missing estimated 2' of outer woven jacket. Firehose should be removed from service.
46 CFR 176.810(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2025
Resolved 4 August 2025
Resolution: New fire hose was installed on the top deck of vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 June 2025
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. A temporary extension cord was used as a permanent means to power the air compressor for the ship's horn. Air compressor should be hardwired for future use.
46 CFR 183.340(r)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 22 August 2025
Resolution: Crew hard-wired ship's whistle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 25 June 2025
Resolved
At each inspection for certification... the bilges and other spaces may be examined to see that there is no excessive accumulation of oil…that might create a fire hazard... Marine Inspector observed oil accumulation saturated in the overhead insulation in the vicinity of the starboard main engine. The insulation became oil soaked by an oil leak on the starboard main engine that became airborne when it made contact with the spinning flywheel. Remove the oil soaked insulation, clean the surfaces free of residual oils, and renew the insulation with new, suitable materials.
46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 21 August 2025
Resolution: Crew replaced oil soaked insulation in engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 May 2024
Resolved
46 CFR 185.702(b); The owner or managing operator shall make sure that maintenance is carried our in accordance with the instructions required. Life floats found with deteriorated exteriors requiring patching per manfacture's guidance.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 17 June 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 May 2024
Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the coginzant OCMI. Vessel installed new A/C unit on a previously listed spare curcuit. Vessel shall submit the required drawings/specifications as mandated by the MSC plan review guides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2024
Resolved 28 January 2025
Resolution: vessel has completed approved MSC plan review process for the installed AC
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2024
Resolved
46 CFR 183.220(d); All electrical equipment and circuits must be clearly marked and identified. Distribution panel had improperly labeled circuits identifying some as spare while in use. Must be updated to reflect current arrangement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 17 June 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2023
Resolved
Cable and wiring requirements.
Each connection to a conductor or terminal part of a conductor must be made within an enclosure.
Exposed connections in wiring to engine block heaters and water heater within engine room; add junction boxes/rewire as necessary to meet requirements.
46 CFR 183.340 (g)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 29 June 2023
Resolution: Received photographic evidence clearing def.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 23 May 2023
Resolved
Separation of machinery and fuel tank spaces from accommodation spaces. Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors.
Hole in overhead of engine compartment around galley deck drain compromises separation of engine room from galley/accommodation space. Properly seal/install covering around drainage pipe where it passes through overhead of engine compartment.
46 CFR 177.405 (c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 29 June 2023
Resolution: Received photographic evidence clearing def.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 June 2021
Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that loads must be arranged so that loads can be energized from two sources of electricity.
Fire pump and bilge pump currently can only be energized from one source.
CITE: 46CFR183.310(a)(1)
Note: Future permanent fire pump shall have ability to operate remotely from both operating station and local operation at pump
CITE: 46CFR181.300
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 9 July 2021
Resolution: Vessel piped PTO bilge pump to be used at the secondary fire pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2020
Resolved
Exposed wire at stbd engine batter from bus to terminal (invalid end connection). Must either remove wire or secure to terminal with valid connector.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 18 June 2020
Resolved 18 June 2020
Resolution: Provided photo of acceptable installation of wire.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 16 June 2020
Resolved
Bilge high water alarm in forward compartment was inoperable. Pump is functional, but alarm does not sound in pilot house.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 June 2020
Resolved 18 June 2020
Resolution: Master replaced sensor/switch at bilge pump and provided video evidence of functionality.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 May 2019
Resolved
Port bow damaged from sand blasting of rust, impaired seaworthiness
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2019
Resolved 19 June 2019
Resolution: Vessel was ready for inspection, damage was repaired.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 March 2018
Resolved
Alcohol testing equipment not available. Alcohol testing required within 2 hours of a serious marine incident. Provide vessel with means to conduct alcohol testing as required.
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 17 April 2018
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 March 2018
Resolved
Flammable spray foam insulation found in overhead of engine room above generator; other insulation found hanging from overhead in same space. Remove flammable spray foam insulation and attach hanging insulation throughout engine room overhead.
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 17 April 2018
Electrical › Electric Supply System (service) › Cable
Issued 22 March 2018
Resolved
Battery jumper cables found lying across engine room deck from batteries forward to the generator. Remove battery cables. If wiring is needed to maintain charge to batteries install permanent, appropriately sized wire and switches.
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 17 April 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 March 2018
Resolved
Batteries found with covers lying on deck next to installation. Batteries must be protected from falling objects. Install and maintain covers over batteries.
Due 21 April 2018
Resolved 17 April 2018
Engineering › Steering Gear System › Linkage
Issued 22 March 2018
Resolved
Pins and fasteners holding connections of steering gear found with insufficient lubrication. Maintain adequate lubrication between friction surfaces throughout steering system.
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 17 April 2018
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 March 2018
Resolved
Pipe from sewage tank is leaking creating a hazardous condition. Repair system with materials compatible with installed MSD to prevent escape of gas or liquid.
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 17 April 2018
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 March 2018
Resolved
Wooden platform in port side steering gear space under water heater prohibits crew access to maintain steel hull plating allowing for increased corrosion. Platform also prohibits inspection of space by USCG marine inspectors. Modify platform to allow access for regular inspection and maintenance of internal vessel hull.
Action required: 705 - Other - as specified
Due 21 April 2018
Resolved 17 April 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 March 2017
Resolved
Machinery space has auto-acutuation of fixed CO2 system but no time delay to allow personnel evacuation. Install time delay per guidance of NFPA 12(2015), Chapter 9.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 March 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 March 2017
Resolved
COI not posted in a conspicuous space observable to passengers.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 13 March 2017
Resolution: COI remounted in passenger-accessible area.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 March 2017
Resolved
The shore-tie connection was parting in way of the shore-side plug
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 21 March 2017
Resolution: Shore-tie shortened to remove the worn section.
Electrical › Electrical Distribution System (service) › Conductor
Issued 11 April 2016
Resolved
Replace exposed and damaged cable in machinery space. 46 CFR 183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Vessel operator replaced roughly 13' of ground wire and 2.5' of power cable. Marine inspector visually inspected.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 11 April 2016
Resolved
Seal hole in overhead above generator in engine room space (make vapor tight). 46 CFR 177.405(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2016
Resolution: Hole was sealed off and made vapor tight. Marine Inspector visually inspected.