SPIRIT OF CHARLESTON

SPIRIT OF CHARLESTON is a 1985 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in April 2026, along with 39 deficiencies — 2 with no resolution recorded — and 2 casualty investigations between 2002 and 2007.

Records from 2002 to 2026. Most recent: inspection, 7 April 2026.

Built
1985
Last inspected
7 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 April 2026
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4623
264362
Flag
UNITED STATES
Maury page id
psix-264362

Documentation record

Registered dimensions (L × B × D)102.0 ft × 30.1 ft × 5.1 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOREAUVILLE, LA, UNITED STATES · built 1985
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

23 inspections, each with its date, unit and type; 39 deficiencies with the resolution recorded against each; 2 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

7 April 2026 Special Consideration
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8358069
2 February 2026 MSP Additional Oversight - Risk Assessment · COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8303526
28 October 2025 Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8260126
3 September 2025 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8226296
10 June 2025 Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8157238
8 May 2025 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8131595
25 April 2025 Internal Structural Exam · Drydock Extension
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8119897
17 March 2025 Drydock Extension
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8095701
19 December 2024 Internal Structural Exam · Drydock Extension · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8049313
9 October 2024 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8016555
18 March 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7883470
3 May 2023 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7680223
22 November 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7598966
16 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7451697
4 February 2022 MTSA Verification · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7391079
4 June 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7225812
19 March 2020 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6928901
4 November 2019 MTSA Verification · Plan Review (Other than "T") · Internal Structural Exam · Drydock Extension · Examination of Repairs · Drydock Exam · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6848775
8 March 2019 Examination of Repairs · MTSA Verification · Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6638860
29 November 2017 COI Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6314632
6 November 2017 Hull Examination · Drydock Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6308008
28 February 2017 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6101295
3 March 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5826324

Deficiency record · 39

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 February 2026 No resolution recorded
All storage cylinders used for storing carbon dioxide must be fabricated, tested, and marked in accordance with the requirements of 147.60 and 147.65 of this chapter. Vessel has 01 cylinder needing replacement. 46 CFR 181.20-30 Old T **After reconsideration, updated def from 701 to 705 for 60 days** **Special Consideration granted for fireboy install, extension granted to December 31, 2026** Activity 8358069
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2026 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Port shut off valve was inoperable. 46CFR182.20-40
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2026
Resolved 20 March 2026
Resolution: New remote operated valve control installed. Tested satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 5 February 2026 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Unable to conduct MOB drill due to ship condition. 46 CFR 185.520
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2026
Resolved 20 March 2026
Resolution: Drills conducted satisfactory.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 5 February 2026 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Outlet box cover was missing in exhaust stack compartment. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2026
Resolved 20 March 2026
Resolution: Outlet box cover added to box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 February 2026 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Bilge pump was unable to sufficiently dewater each space. 46 CFR 182.25-5 Old T
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2026
Resolved 20 March 2026
Resolution: Bilge pump tested satisfactory after installation of new pump.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 February 2026 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Forward void space cable transit on the aft bulkhead STBD side was not assembled correctly to maintain watertight integrity of the bulkhead.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2026
Resolved 20 March 2026
Resolution: Cable transit bolcok was tightened to create a watertight seal.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 February 2026 No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Observed missing weld on cable transit in forward void space, port side of aft bulkhead. Observed cracked weld on forward bulkhead. Welds to be corrected at next drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 February 2026 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Cable penetrations in forward and aft bulkheads within the fuel tank space were not watertight.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 27 March 2026
Resolution: Verified correct installation of roxtec cable penetrations.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 February 2026 Resolved
Fire hose shall be 1 1/2" in diameter and 50 feet length....if used after January 1, 1980 each length of hose must be: be lined commerical fire hose that conforms to Underwriters' Laboratories, Inc., Standard 19 or federal Specification ZZ-H_451E. Fire Hoses on board did not conform to the above standards and were 75' long. 46 CFR 181.15-10 "Old T"
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 27 March 2026
Resolution: Verified installation of UL19 lined fire hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 May 2025 Resolved
Exhaust piping shall be gas-tight throughout its length. 46CFR182.15-20(a) Inspectors found soot on Starboard main diesel engine exhaust pipe lagging indicating an exhaust gas leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2025
Resolved 19 May 2025
Resolution: In the presence of MI's, vessel ran starboard side engine and engine exhaust did not leak.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. 46CFR183.01-15(a) Inspectors found exposed wiring IVO starboard main diesel engine jacket water heater.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2025
Resolved 19 May 2025
Resolution: Loose wiring around starboard side engine removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 December 2024 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space, including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Identified leaking temp repair on the pme exhaust ovbd and excessive pitting on pipe and flange.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 23 December 2024
Resolution: Completed visual inspection of final welds on flange and pipe, all satisfactory. CSI completed PT on welds.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 March 2024 Resolved
Valves shall be in accordance with good marine practice. The upper deck fire main valve is leaking from the stem and allowing blow-by when fully closed. Repair/service valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2024
Resolved 22 April 2024
Resolution: New fire main was installed by fire service company.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 May 2022 Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: (iv) Navigation equipment and lights. VHF did not have a secondary source of power. 46 CFR 183.310
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2022 Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations. E/R cabling not secured with metal supports. Metal supports present in adjacent spaces but exceed the 24 inch 46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 22 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2022 Resolved
Each PFD must have at least 200 sq. cm. (31 sq. in.) of retroreflective material on its front side, at least 200 sq. cm. on its back side and at least 200 sq. cm. of material on each reversible side, if any. Retroreflective tape worn and not operational on Type I lifejackets. 46 CFR 160.077-13
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 May 2022 Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States: (a) Every power-driven vessel of 20 meters or over in length while navigating. The vessel does not have a current Bridge-to-Bridge certificate. Correct radio station ship data for proper transmitting; general class is listed as please craft. 47 CFR 80.1001(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 27 May 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 16 May 2022 Resolved
Penetrations and openings in watertight bulkheads must (1) Be kept as high and as far inboard as practicable; and (2) Have means to make them watertight E/R penetration weld cracked; make repairs and conduct satisfactory non-destructive testing to the satisfaction of the attending marine inspector. 46 CFR 171.114
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 May 2023
Resolution: Suspected crack in weld was inspected during vessel's drydock and found to be an undercut. NDT was conducted and found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2021 Resolved
The owner of managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Receive approval from Marine Safety Center for electrical installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2021
Resolved 10 March 2021
Resolution: Plans are approved by MSC
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2021 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations and not used as a means of support. Properly support wiring in engine room per approved means.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 March 2021
Resolution: Wire supports were installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2021 Resolved
Working space must be provided around all main distribution panels and switchboards of at least 24 inches in front of the switchboard. Switchboard in the galley was blocked. Move galley equipment to ensure regulated access.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 March 2021
Resolution: Item were moved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2021 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either a pressure type connector on each conductor, a solder lug, a splice made with a pressure type connector to a flexible lead or conductor, or a splice that is soldered, brazed, or welded to a flexible lead or conductor. Address open ended wiring in the bridge and engine room. Replace wire nuts on the bridge with approved means.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 March 2021
Resolution: Wiring was terminated properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 February 2021 Resolved
Each penetration is accomplished using an acceptable metallic fitting, welded of otherwise attached to the bulkhead of deck by an acceptable method. Hole found in the engine room aft bulkhead. Ensure penetration is closed off by acceptable method.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 March 2021
Resolution: The penatration was sealed with watertight fire block.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 February 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Found 24 life jackets to be wasted. Replace to ensure adequate amount as required by vessel's COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 10 March 2021
Resolution: Placed new life jackets in service.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 February 2021 Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located at a conspicuous place at or near each pull box. Ensure pull stations for Halon extinguishing system is marked and operating instructions are posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 16 May 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 February 2021 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the [name withheld] extinguisher bracket not sufficient for the portable fire extinguisher in the engine room. Replace with correct bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 16 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 February 2021 Resolved
A cooking appliance must be installed to prevent movement in heavy seas. Ovens in the galley were found unsecured and easily moved. Ensure ovens are secured to prevent shifting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 16 May 2022
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 February 2021 Resolved
The intent of this part is to ensure that the scantlings, material, fastenings, workmanship, and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspections. For the safety of the crew, ensure the ladder access to the engine room is secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 16 May 2022
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 February 2021 Resolved
The official number of the vessel, preceded by the abbreviation "NO" must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural party of the hull. Repaint official number to ensure adequately marked.
Due 22 February 2021
Resolved 16 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 8 February 2021 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Provide current deviation card for magnetic compass.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 16 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 March 2019 Resolved
Verify operation of mast light and paint screen matte black.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2019
Resolved 20 March 2019
Resolution: Vessel inspected light abd painted screen matte black.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 15 March 2019 Resolved
Vessel required to be equiped with DSC. Install and renew safety radio certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 10 April 2019
Resolution: Vessel had two new radios installed and FCC safety radio certicate renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2019 Resolved
Ground indicating lights on SSWBD not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 10 April 2019
Resolution: Vessel owner has submitted plans to correct the def with the installation of new equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 March 2019 Resolved
25% of lifejackets need retro replaced due to failure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 10 April 2019
Resolution: Vessel replaced retro on required life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 March 2019 Resolved
BSSDG windings are coated with oil
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2019
Resolved 26 March 2019
Resolution: Recieved report from Reese Marine equipment & repair [phone withheld] that both SSDG windings were cleaned.
Engineering › Compressed Air System (control) › Compressor
Issued 4 December 2017 Resolved
Missing guard on air compressor. Replace/repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 9 January 2018
Resolution: A new guard was placed in service.
Engineering › Generator (propulsion-electric) › Wiring
Issued 4 December 2017 Resolved
Exposed wiring on generator. Clean and blank areas where exposed.
Condition: Improper/Lack of Maintenance
Due 31 December 2017
Resolved 9 January 2018
Resolution: Two covers were placed in service.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 December 2017 Resolved
STBD side storage hold light has exposed wiring. Repair to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 9 January 2018
Resolution: A new light fixture was placed in service.
Engineering › Steering Gear System › Bracket/Clamp
Issued 3 March 2016 Resolved
Replace broken hanger for steering gear hydraulic hose.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 3 March 2016
Resolution: A new pipe hanger was placed in service.

Casualty record · 2

25 October 2002Routine · role: Involved in a Marine Casualty · activity 1704385
22 July 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3007353
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.