Records from 2009 to 2026. Most recent: inspection, 1 June 2026.
Inspection history · 27
1 June 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8385600
15 January 2026
Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8297382
2 June 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8150126
9 December 2024
Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8046762
1 March 2024
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7872733
9 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7845137
13 February 2023
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7637802
10 January 2023
Examination of Repairs · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7619566
21 November 2022
COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7591445
5 April 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7425112
4 February 2022
MTSA Verification · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7391093
8 November 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7347440
8 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7173449
19 March 2020
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6928887
17 October 2019
Drydock Exam · Administrative Inspection · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6836598
26 March 2019
DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6649152
18 December 2018
Plan Review "T" Boat · Deficiency Check · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6599833
9 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6409846
9 January 2018
COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6334054
29 September 2017
Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6281277
8 August 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6234227
6 April 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6123759
15 November 2016
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6043066
10 May 2016
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5873708
6 April 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5848243
11 March 2016
Administrative Inspection · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5835350
22 January 2016
Drydock Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5801970
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2026
No resolution recorded
Exhaust piping shall be....gas-tight throughout its length.
Starboard exhaust aft of bulkhead in Lazarette has been inadequately repaired using doubler plates. Will require crop and renew.
To be completed. NLT 22APR27/Next Annual Inspect.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 June 2026
Resolved
Openings through which conductors enter shall be adequately closed.
Shore-tie cable access through aft deck is missing an adequate cable gland.
OLD 46 CFR 183.10-20(f)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 23 June 2026
Resolution: O/O provided picutre evidance of insstallation of stuffing tube.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 June 2026
Resolved
AIS Class A device. The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: A self-propelled vessel that is certificated to carry more than 150 passengers.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 14 July 2026
Resolution: Vessel representative sent in photos and documentation of work completed to install new Class A AIS.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 1 June 2026
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship....
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 2 June 2026
Resolution: Vessel representative emailed garbage management plan with all proper items listed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 June 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible.
Nautical Charts on board are out of date.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 23 June 2026
Resolution: O/O provided picture evidence showing new charts with updated dates.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 June 2026
Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection ...shall require that all observed unsafe practices and hazardous situations be corrected.Wiring within the pilot house is unsecured on the aft bulkhead along with A/C lines. In addition there is a loose antenna on top of pilot house.
OLD 46 CFR 176.25-50
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 23 June 2026
Resolution: Photo evidence provided showing repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2025
Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended.
Port side engine fuel strainer is missing a flame impingement bowl.
46 CFR 182.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 17 June 2025
Resolution: Fuel bowl replaced on starboard side fuel strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
14 lifejackets were unserviceable at the time of the inspection. Total persons on board restricted to 260 until lifejackets are replaced.
Action required: 705 - Other - as specified
Resolved 6 June 2025
Resolution: 18 new type approved lifejackets have been placed on the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 March 2024
Resolved
When a marine employer determines that a casualty or incident is, or is likely to become, a serious marine incident, the marine employer shall take all practicable steps to have each individual engaged or employed on board the vessel who is directly involved in the incident chemically tested for evidence of drug and alcohol use as required in this part.
Vessel did not have steps to conduct drug and alcohol testing if a serious marine incident were to occur.
Action required: 705 - Other - as specified
Due 13 March 2024
Resolved 7 March 2024
Resolution: Received mandatory chemical testing procedures from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2022
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level.
The high water alarm in the store room was not permanently mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 5 December 2022
Resolution: Provided images showing high water alarm permanently mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2022
Resolved
The owner, charterer, master, or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency.
The crew was unfamiliar with the bilge and fire pump operation and needed additional man overboard competency
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 13 December 2022
Resolution: Images provided for logged training and operating instructions mounted at the bilge and fire pump.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 November 2022
Resolved
Wiring, where subject to mechanical damage shall be protected.
The wiring powering Emergency lighting in the vessel's heads was disrupted by the drawer closure on bridge.
OLD T - 46 CFR 183.05-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 5 December 2022
Resolution: Provided images of emergency lighting operating as designed. Wires moved and restrained away from future mechanical damage.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2022
Resolved
Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit.
Twist type connectors were used in the steering compartment and engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 6 December 2022
Resolution: Provided images of wires terminated in heat shrink and wrapped in electrical tape.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2022
Resolved
All electrical equipment and circuits must be clearly marked and identified.
Circuits were missing a identification card.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 5 December 2022
Resolution: Provided image with panel board directory filled out.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 November 2022
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment.
The vessel did not have Fire Fighting Service Reports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 13 December 2022
Resolution: Provided digital records of fire servicing completed in December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 November 2022
Resolved
At least one ring life buoy must be fitted with a lifeline. Each ring life buoy with a floating waterlight must have a lanyard
The life line and waterlight line were in a frayed condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 2 December 2022
Resolution: Images providded of satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 November 2022
Resolved
A hatch exposed to the weather must be watertight.
Gaskets on deck hatches were wasted and need replacement.
46 CFR 116.11160
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2022
Resolved 14 December 2022
Resolution: Gaskets replacedon deck hatches.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 November 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
The vessel only has 239 Adult life jackets and 0 child life jackets.
Limited to no more than 239 Adults and 0 children IAW number of life jackets on board vessel.
Action required: 705 - Other - as specified
Due 5 December 2022
Resolved 2 December 2022
Resolution: Images provided of satisfactory equipment.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 5 April 2022
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any water tight compartments. Bilge pump cover spraying water.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 19 April 2022
Resolution: Vessel rep emailed proof of def rectified.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 April 2022
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces. Vessels high water alarm in lazaret not secured to indicate properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 19 April 2022
Resolution: Vessel rep emailed proof of def rectified.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 April 2022
Resolved
The owner or managing operator shall provide satisfactory evidence of fire extinguishers completing required servicing to the marine inspector. Vessels 40:BC and 2:A need to be serviced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 19 April 2022
Resolution: Vessel rep emailed proof of def rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 April 2022
Resolved
Each water light must be approved in accordance with 161.010 in subchapter Q. Vessels water light needs new battery service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 19 April 2022
Resolution: Vessel rep emailed proof of def rectified.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 April 2022
Resolved
Adequate emergency lighting automatically actuated upon failure of main engine lighting shall be fitted below the main deck. Vessel missing e-lighting in engine room and at ladder well at starboard aft of main deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 19 April 2022
Resolution: Vessel rep emailed proof of def rectified.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 5 April 2022
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel had no record of DAPI enrollment on board vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 8 April 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2022
Resolved
Wire sizes for power supply shall be in accordance with Table 183.05-45(a). Vessel had temporary extension chord powering AC drain pump.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 5 May 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 April 2021
Resolved
Penetrations and openings in watertight bulkheads must be kept as high and as far inboard as practicable and have means to make them watertight.
Penetrations found in engine room forward bulkhead and aft watertight compartment with inadequate watertight material.
46 CFR 171.114(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must
be repaired or replaced.
PFD retro-reflective material needs to be replaced.
46 CFR 115.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 April 2021
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
Oil diapers found in all bilges and need to be removed.
46 CFR 115.830(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 June 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 10 Lifejackets were unserviceable. passenger count reduced by 10 pob.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2019
Resolved
Each line shall be provided with a stop valve at the control point or manifold in addition shall be provided with a check valve at some accessible point.
Space below the snack bar is missing a check valve.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2019
Resolved 19 December 2019
Resolution: Verified the installation and operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2019
Resolved
T-L the two required fixed power bilge pumps shall be self priming and have a capacity of 50 gpm.
Bilge pump is currently being primed and continuously operated with sea water which is reducing the capacity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2019
Resolved 19 December 2019
Resolution: Installed new Jabsco impellor pump conducted satisfactory operational test.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 April 2019
Resolved
COD is expired
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2019
Resolved 10 April 2019
Resolution: Vessel owner provided current COD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 April 2019
Resolved
36 Lifejackets found unservicable passenger count reduced to 232
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2019
Resolution: Replaced unservicable life jackets
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 April 2019
Resolved
FCC station license expired, Passenger safety radio expires 10APR2019, and DSC is not operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 April 2019
Resolution: FCC issued new cert and enabled DSC
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2019
Resolved
Lazz SSDG belt guard is broken.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2019
Resolved 16 May 2019
Resolution: Replaced SSDG belt guard
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 9 April 2019
Resolved
Emergency Broadcast placard is missing
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2019
Resolved 22 April 2019
Resolution: Replaced emergency broadcast placard
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 9 January 2018
Resolved
Replace worn engine room WTD gasket
Due 31 January 2018
Resolved 31 January 2018
Documentation › Certificates/Documents › FCC SSL
Issued 6 April 2017
Resolved
Renew expired Radiostation license.
Due 6 May 2017
Resolved 8 August 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 April 2017
Resolved
Repair raw water cooling leak in generator hose connection.
Due 6 May 2017
Resolved 8 August 2017
Electrical › Electric Supply System (service) › Cable
Issued 6 April 2017
Resolved
Remove twist on wire connectors from high water alarm splices & repalce with proper connections IAW subchapter J.
Due 6 May 2017
Resolved 8 August 2017
Electrical › Electric Generation Source (service) › Power Requirement
Issued 15 November 2016
Resolved
Derate 40 Deg C Genset to 80% of the full load rating.
Due 15 December 2016
Resolved 8 August 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 April 2016
Resolved
Double clamp connections on generator raw water cooling hose.
Due 6 May 2016
Resolved 10 May 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 April 2016
Resolved
Replace Raw water cooling hose on genset with approved non-collapsing hose.
Due 6 May 2016
Resolved 10 May 2016
Electrical › Electric Generation Source (service) › Power Requirement
Issued 6 April 2016
Resolved
Submit rating data sheet for new genset to MI.
Due 6 May 2016
Resolved 15 November 2016
Electrical › Electric Generation Source (service) › Generator Cable
Issued 6 April 2016
Resolved
Provide proper support for genset starter cable & re-crimp negative terminal.
Due 6 May 2016
Resolved 10 May 2016