MAURY USCG vessel records Sign in
← All vessels

DAHNTAHN DOTTIE

DAHNTAHN DOTTIE is a 1944 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1997, most recently in January 2021, along with 36 deficiencies.

Records from 1997 to 2021. Most recent: inspection, 29 January 2021.

Built
1944
Last inspected
29 January 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

458851
Flag
UNITED STATES
—
Maury page id
psix-458851

Inspections, by type

…with no type recorded5
Years with a record 22 calendar years (1997–2021)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MYRNA FAITH Passenger (Inspected) · MISLE 461003 · 17 July 2009 · activity 3542542

Inspection history · 43

29 January 2021 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7132880
17 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7096937
6 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6710837
26 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6491095
20 March 2018 Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6379341
26 April 2017 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6133548
21 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5867978
10 July 2012 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4375219
7 June 2012 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4335803
1 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4248812
2 August 2011 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4102640
4 October 2010 Plan Review "T" Boat · Simplified Stability Test
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3863592
29 March 2010 COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3704558
17 July 2009 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3542542
1 May 2009 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3465125
9 April 2009 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3452382
17 July 2008 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3271799
12 March 2008 DAPI Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3195186
7 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2955127
9 January 2007 Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2854186
30 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2663912
31 March 2006 In-Service Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2615794
28 June 2005 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2406540
8 April 2005 In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2334104
26 May 2004 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2116570
8 January 2004 Deficiency Check · Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2067469
27 August 2003 Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1886543
20 June 2003 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1840686
22 May 2003 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1798433
10 July 2002 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1648983
15 June 2001 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1393699
26 October 2000 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1055252
15 June 2000 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1437737
19 April 2000 Excursion Permit
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1369623
16 September 1999 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1121016
16 August 1999 Deficiency Check · Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1442879
14 August 1999 Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 778303
2 July 1999 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 214116
12 June 1999 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 187042
3 May 1999 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1455702
5 August 1998 Hull Examination · Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1364958
4 July 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 181123
17 June 1997 Hull Examination · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1460238

Deficiency record · 36

Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 June 2012 Resolved
Combination Port and Starboard running light on the bow is blocked by the headlights. Reinstall or replace the same to allow arc of visibility IAW the NAVRULS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2012
Resolved 10 July 2012
Resolution: Corrected.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 7 June 2012 Resolved
Provide Marine Radio Operators Permit for the Master.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 July 2012
Resolved 10 July 2012
Resolution: Requirement removed until decision made on subject permit.
Documentation › Certificates/Documents › Stability Letter
Issued 1 December 2011 Resolved
Submitted CG-835 due to the dead line for submittal of the AAWPP certification of compliance the following vessels maximum persons allowed will be reduced to comply with the new 185lb AAWPP in accordance with CG 543 Policy Letter 11-03: Max persons allowed is 26
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 March 2012
Resolved 28 March 2012
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 August 2011 Resolved
15 child and 01 adult PFD's were found to be dry rotted and were taken out of service. Company is to replace damaged PFD's by 10Aug11. An 835 was issued reducing passenger count to 15 child and 31 adults.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2011
Resolved 17 August 2011
Resolution: New jackets replace failed jackets.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 August 2011 Resolved
Install automatic engine and vent shutdowns IAW with applicable regulations on a pre-engineered fixed fire fighting system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2011
Resolved 6 September 2011
Resolution: Fireboy shutdown system installed and tested properly.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 2 August 2011 Resolved
Provide state registration numbers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2011
Resolved 27 March 2012
Documentation › Markings/Placards › Warning Signs
Issued 2 August 2011 Resolved
[name withheld] Fuel shutoffs with proper size and visibility.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2011
Resolved 27 September 2011
Resolution: Cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 May 2006 Resolved
Renew stern light and prove proper operation of navigation lights prior to operating in reduced visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 13 June 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 May 2006 Resolved
Prove proper operation of ring buoy waterlight prior to operating in reduced visibility.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 13 June 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 30 May 2006 Resolved
Mount PFD donning instructions.
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 13 June 2006
Construction/Loadline › Structures › Deck Plating
Issued 30 May 2006 Resolved
Crop and renew to good steel deck plating over the engine compartment where wasted at the sheer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 19 March 2007
Resolution: CLEARED
Fire Fighting › Fire Bucket › Availability
Issued 28 June 2005 Resolved
Provide three fire buckets, properly labeled.
Condition: Improper/Lack of Maintenance
Due 15 July 2005
Resolved 3 August 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2005 Resolved
Provide wire support for the wire harness in engine space.
Condition: Improper/Lack of Maintenance
Due 15 July 2005
Resolved 3 August 2005
Engineering › Fuel Oil Service System › Valve
Issued 28 June 2005 Resolved
Mark the location and direction of use of the fuel oil shut off valves
Condition: Improper/Lack of Maintenance
Due 15 July 2005
Resolved 3 August 2005
Lifesaving › Hand Flares › Quantity
Issued 28 June 2005 Resolved
Provide proper quantity of distress signals per 46 CFR 1850.68 ... corrected on scene.
Due 28 June 2005
Resolved 28 June 2005
Resolution: Additional distress signals placed on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 June 2005 Resolved
Prove proper operation of running lights - corrected on scene.
Due 29 June 2005
Resolved 29 June 2005
Resolution: Lights repaired on scene.
Lifesaving › Hand Flares › Quantity
Issued 8 April 2005 Resolved
Provide a total of three red hand and three orange hand flares.
Due 8 April 2005
Resolved 8 April 2005
Resolution: Additional flares placed on board.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 April 2005 Resolved
Renew waterlight battery.
Due 8 April 2005
Resolved 8 April 2005
Resolution: New battery installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 May 2004 Resolved
Place a properly operating waterlight on board prior to operating at night with passengers on board.
Due 1 June 2004
Resolved 26 May 2004
Resolution: Waterlight placed on board.
Lifesaving › Immersion Suits › Serviceable
Issued 26 May 2004 Resolved
Renew expired distress signals.
Due 26 May 2004
Resolved 26 May 2004
Resolution: Distress signals placed on board.
Construction/Loadline › Hull
Issued 27 August 2003 Resolved
Crop and renew wasted area of hull port side 2" forward of engine room bulkhead and 12" below deck level at first rubrail. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Area cropped and renewed satisfactorily.
Construction/Loadline › Hull
Issued 27 August 2003 Resolved
Crop and renew framing at wheel well bulkhead both port and starboard side. LEGACY COMPONENT DESC: Transverse Frame
Condition: Improper/Lack of Maintenance
Due 1 March 2004
Resolved 29 April 2004
Resolution: Frames and aft wells renewed - sat.
Construction/Loadline › Structures
Issued 27 August 2003 Resolved
Renew forward shaft housing hinge assembly hinge pin using split key pins inside and outside of hinge assembly.
Condition: Improper/Lack of Maintenance
Due 27 September 2003
Resolved 25 September 2003
Resolution: New pin installed - sat.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 22 May 2003 Resolved
Prove proper operation of fixed fire extinguishing system. Until corrected an extra crewman shall be carried to maintain a firewatch, examining all spaces while underway. This crewman shall be on board whenever passengers are on board and 1 less passenger than allowed on your COI shall be carried. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Due 30 May 2003
Resolved 30 May 2003
Resolution: An audible alarm was installed and the engine room blower was wired into the system. On discharge the system now produces and audible and visual alarm and shuts down the engineroom exhaust blower.
Fire Fighting › Fixed Fire Detection System
Issued 22 May 2003 Resolved
Prove proper operation of the engine compartment flammable vapor detector. LEGACY COMPONENT DESC: Detector/Call Point Grouping
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2003
Resolved 23 May 2003
Resolution: A new detector was installed and tested sat.
Operations/Management › Drills/Instruction
Issued 22 May 2003 Resolved
Conduct man overboard and fire drills in the presence of a marine inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Due 22 June 2003
Resolved 20 June 2003
Resolution: Conducted drills - sat.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 22 May 2003 Resolved
Provide the boat with a sound signalling device prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 23 May 2003
Resolution: A handheld sound signalling device was placed on board (air powered horn).
Electrical › Lighting (emergency)
Issued 10 July 2002 Resolved
PROVIDE TWO PORTABLE LIGHTS. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2002
Resolved 11 July 2002
Resolution: PROVIDED TWO PORTABLE FLASHLIGHTS.
Operations/Management › Navigation Safety
Issued 10 July 2002 Resolved
PROVIDE COPY OF RULES OF THE ROAD. 46 CFR 184.420. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2002
Resolved 15 August 2002
Resolution: PROVIDED COPY OF NAVIGATION RULES.
Lifesaving › Lifebuoys
Issued 10 July 2002 Resolved
REPAIR DIVIT IN LIFEBUOY COVERING.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 August 2002
Resolved 15 August 2002
Resolution: PROPERLY REPAIRED DIVIT.
Lifesaving › Hand Flares
Issued 10 July 2002 Resolved
MARK "DISTRESS SIGNALS" ON CONTAINER. 46 CFR 185.614 LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2002
Resolved 11 July 2002
Resolution: PROPERLY MARKED CONTAINER.
Deck/Cargo › Mooring/Anchoring
Issued 10 July 2002 Resolved
PROVIDE AT LEAST TWO MOORING LINES FOR VESSEL. 46 CFR 184.300. LEGACY COMPONENT DESC: Mooring Line/Hawser
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2002
Resolved 11 July 2002
Resolution: PROVIDED TWO LINES STORED IN FORWARD COMPARTMENT.
Lifesaving
Issued 15 June 2000 Resolved
THE VESSELS PLASTIC PASSENGER COMPARTMENT WINDOWS SHALL REMAIN ROLLED UP_x001C_ AND SECURED WHEN THE VESSEL IS OPERATING IN THE WATER. A PERMANENT RELEASE SYSTEM SHALL BE INSTALLED.
Condition: Unknown
Due 15 June 2000
Resolved 15 June 2000
Construction/Loadline
Issued 16 August 1999 Resolved
REPLACE EXISTING RULE PUMP DISCHARGE HOSE WITH GOOD QUALITY RUBBER DISCHARGE HOSE.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Construction/Loadline
Issued 16 August 1999 Resolved
REPLACE EXISTING BILGE BLOWER HOSE WITH PERMANENTLY INSTALLED SHEET METAL DUCT PIPE.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Construction/Loadline
Issued 3 May 1999 Resolved
INSTALL A REAR BILGE PUMP ASSEMBLY AS ORIGINAL.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999

Ownership record