MAURY USCG vessel records Sign in
← All vessels

MYRNA FAITH

MYRNA FAITH is a 1945 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1997, most recently in January 2021, along with 49 deficiencies.

Records from 1997 to 2021. Most recent: inspection, 29 January 2021.

Built
1945
Last inspected
29 January 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

461003
Flag
UNITED STATES
—
Maury page id
psix-461003

Inspections, by type

…with no type recorded7
Years with a record 20 calendar years (1997–2021)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DAHNTAHN DOTTIE Passenger (Inspected) · MISLE 458851 · 17 July 2009 · activity 3542542

Inspection history · 47

29 January 2021 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7132890
11 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6710953
9 May 2019 Plan Review "T" Boat · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6686328
26 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6490996
23 March 2018 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6377346
20 March 2018 Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6377350
24 October 2017 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6293822
23 October 2017 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6293454
14 June 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6177529
19 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5868181
26 June 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4357025
1 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4248820
17 August 2011 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4119507
17 July 2009 Type not recorded
No type recorded · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3542542
1 May 2009 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3465100
9 April 2009 DAPI Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3452236
9 April 2009 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3452355
21 July 2008 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3274708
7 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2955136
30 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2663911
31 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2615743
28 June 2005 COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2406554
8 April 2005 In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2334092
14 December 2004 Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2293422
27 October 2004 Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2229311
6 July 2004 Annual Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2122970
25 May 2004 In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2116430
18 July 2003 Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1850021
20 June 2003 Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1825216
10 June 2003 In-Service Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1798394
9 July 2002 Re-Inspection · Administrative Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1642997
19 June 2001 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 212946
14 June 2001 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1393698
17 April 2001 Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1415577
26 October 2000 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 823479
16 October 2000 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 823987
30 August 2000 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 822378
30 June 2000 COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1444367
16 June 2000 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1436401
28 June 1999 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1464860
14 May 1999 Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1384064
24 July 1998 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1131616
22 June 1998 Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 791861
2 June 1998 Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1427520
6 February 1998 Deficiency Check · Examination of Repairs
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1466497
28 August 1997 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1468416
30 June 1997 Initial Certification · Plan Review "T" Boat · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1116030

Deficiency record · 49

Stability › Unintentional Flooding › General
Issued 10 April 2018 Resolved
Primary dewatering pump inoperative. Proove proper operation of pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2018
Resolved 13 April 2018
Resolution: Pump replaced.
Engineering › Steering Gear System › Linkage
Issued 23 October 2017 Resolved
Steering cable assy INOP. Repair as required.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2017
Resolution: Replaced a broken sheer pin in the steering column pulley assembly. Technical reps presented documentation demonstrating that the system worked as designed in the case that the rudder was jammed by a foreign object.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 June 2012 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 10 July 2012
Resolution: Corrected.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 26 June 2012 Resolved
Provide sign to remind operators to energize blower prior to starting engines.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 10 July 2012
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 June 2012 Resolved
Remove or reposition the bolts on port shelf box to avoid injury.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 10 July 2012
Resolution: Corrected.
Documentation › Certificates/Documents › Stability Letter
Issued 1 December 2011 Resolved
Submitted CG-835 due to the dead line for submittal of the AAWPP certification of compliance the following vessels maximum persons allowed will be reduced to comply with the new 185lb AAWPP in accordance with CG 543 Policy Letter 11-03: Max persons allowed 21.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2012
Resolved 15 May 2012
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 August 2011 Resolved
Install automatic engine and vent shutdowns IAW applicable regulations on a pre-engineered fixed fire fighting system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2011
Resolved 27 September 2011
Resolution: Cleared.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 17 August 2011 Resolved
Provide state registration numbers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2011
Resolved 13 May 2012
Documentation › Markings/Placards › Warning Signs
Issued 17 August 2011 Resolved
[name withheld] fuel shutoffs with proper size and visibility.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2011
Resolved 27 September 2011
Resolution: Cleared.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 August 2011 Resolved
Trouble shoot second VHF-FM radio to assure it is transmitting proper distance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2011
Resolved 20 August 2011
Resolution: O/O found a disconnected co-axil cable. It was rerouted, reconnected and the radio tested sat.
Engineering › Fuel Oil Service System › Valve
Issued 28 June 2005 Resolved
Mark location and direction of operation of fuel shut off valves.
Due 15 July 2005
Resolved 3 August 2005
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 28 June 2005 Resolved
Make permanent repairs to modified hinge pin assembly on forward drive shaft housing.
Action required: 705 - Other - as specified
Due 2 November 2005
Resolved 31 March 2006
Lifesaving › Hand Flares › Quantity
Issued 8 April 2005 Resolved
Provide a total of three red hand and three orange hand flares.
Due 8 April 2005
Resolved 8 April 2005
Resolution: Additional flares placed on board.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 April 2005 Resolved
Renew waterlight battery.
Due 8 April 2005
Resolved 8 April 2005
Resolution: New battery installed.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 6 July 2004 Resolved
Make permanent repairs to modified hinge pin assembly on forward drive shaft housing.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 25 February 2005
Resolution: Hull repairs made
Construction/Loadline › Hull › Side Shell
Issued 6 July 2004 Resolved
Make permanent repairs to wasted side shell behind enclosed rub rail on starboard side.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 25 February 2005
Resolution: Hull repairs made
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 May 2004 Resolved
Provide one (1) additional adult size PFD for a total of thirty-two (32) adult PFDs on board per the vessel COI.
Due 1 June 2004
Resolved 25 May 2004
Resolution: An additional PFD was placed on board.
Lifesaving › Hand Flares › Expired
Issued 25 May 2004 Resolved
Renew expired distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2004
Resolved 25 May 2004
Resolution: New distress signals placed on board.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 May 2004 Resolved
Renew waterlight battery.
Due 1 June 2004
Resolved 25 May 2004
Resolution: A new battery was installed.
Construction/Loadline › Penetrations
Issued 20 June 2003 Resolved
Renew hinge pin on aft hinge assembly.
Condition: Improper/Lack of Maintenance
Due 20 July 2003
Resolved 18 July 2003
Resolution: New hinge pin installed and properly cotter pinned.
Construction/Loadline › Penetrations
Issued 20 June 2003 Resolved
Renew bolts on forward hinge assembly and ensure they are cotter pinned to prevent loosening of the nuts.
Condition: Improper Installation
Due 20 July 2003
Resolved 18 July 2003
Resolution: New bolts installed. Washers used to properly align bolts. Cotter pins installed to prevent nuts from backing off.
Lifesaving › Lifebuoys
Issued 20 June 2003 Resolved
Renew floating waterlight prior to operating at night. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 20 July 2003
Resolved 23 June 2003
Resolution: A new waterlight was placed on board.
Fire Fighting › Miscellaneous Items
Issued 20 June 2003 Resolved
Provide three marked fire buckets.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2003
Resolved 20 June 2003
Resolution: Fire buckets placed on board.
Engineering › Bilge Water Management System
Issued 20 June 2003 Resolved
Ensure higgins pump bilge suction strainer is securely fastened. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Due 20 July 2003
Resolved 18 July 2003
Resolution: Strainer properly installed.
Engineering › Gasoline Engine (propulsion)
Issued 20 June 2003 Resolved
Ensure exhaust blower switches are interlocked with the starter and ignition switches so that blowers are started before the engine starter motor circuit or the engine ignition is energized. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Due 20 July 2003
Resolved 18 July 2003
Resolution: Blower and starter properly interlocked.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 23 May 2003 Resolved
Prove proper operation of fixed fire extinguishing system. Until corrected an extra crewman shall be carried to maintain a firewatch, examining all spaces whie underway. This crewman shall be on board whenever passengers are carried and 1 less passenger than allowed on your COI shall be carried.
Condition: Improper Installation
Due 30 May 2003
Resolved 30 May 2003
Resolution: An audible alarm was installed and the blowers were wired to the fixed fire system so as to shut down on activiation of the system. System tested sat in presence of the marine inspector.
Personnel › Training
Issued 9 July 2002 Resolved
Evidence of First Aid & CPR training was not available LEGACY COMPONENT DESC: First Aid/CPR
Condition: Unknown
Due 10 August 2002
Resolved 15 August 2002
Resolution: Evidence provided at main office.
Lifesaving › Visual Distress Signals (General)
Issued 9 July 2002 Resolved
Missing "DISTRESS SIGNALS" markings on box. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Due 10 August 2002
Resolved 15 August 2002
Resolution: Distress signals box was appropriately marked with black marker.
Documentation › Manuals/Policy Documentation
Issued 9 July 2002 Resolved
Missing copy of navigation rules of the road and updated river charts on board. LEGACY COMPONENT DESC: Bridge Resource Management Policy/Procedures
Condition: Improper/Lack of Maintenance
Due 10 August 2002
Resolved 15 August 2002
Resolution: Provided copy of NAV-Rules. New copies of river charts were brought on board. Additional copy of a 2002 River Guide book was provided.
Lifesaving › Lifebuoys
Issued 9 July 2002 Resolved
Life ring has 1 puncture 1" diameter. Repair required.
Condition: Improper/Lack of Maintenance
Due 10 August 2002
Resolved 15 August 2002
Resolution: Life bouy was repaired with a patching paste. No exposed or broken areas visible.
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 July 2002 Resolved
Provided kit does not meet prescribed standards. Suggested list of items was given to operator. LEGACY COMPONENT DESC: Medicine Chest
Condition: Placed in Improper Service
Due 10 August 2002
Resolved 15 August 2002
Resolution: Additions to kit were made. All suggested items and/or their equivlient were present.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 9 July 2002 Resolved
Extinguisher located starboard aft was not connected to a bracket. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Due 10 August 2002
Resolved 15 August 2002
Resolution: Fire extinguisher was mounted with marine type bracket not allowing free movement in any direction.
Engineering › Steering Gear System
Issued 9 July 2002 Resolved
Packing around rudder stock was loose causing excessive leakage. Packing was renewed at start of season as part of maintenance. Required tighten/replace as necessary. LEGACY COMPONENT DESC: Rudder Stock
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 10 July 2002
Resolution: Corrected on site. Rudder stock tightened to an appropriate drip.
Deck/Cargo › Mooring/Anchoring
Issued 9 July 2002 Resolved
Mooring lines were not on board. Required placement of mooring lines on vessel as part of god marine practices LEGACY COMPONENT DESC: Mooring Line/Hawser
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2002
Resolution: Mooring lines placed on board.
Engineering › Fuel Oil Service System
Issued 9 July 2002 Resolved
Lower clamp for rubber hose connecting fuel fill and tank was loose. Required correction. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2002
Resolution: Clamp tightened.
Engineering › Fuel Oil Storage/Transfer System
Issued 9 July 2002 Resolved
Grounding strap between tank fill and tank missing. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 10 August 2002
Resolved 15 August 2002
Resolution: Grounding strap was placed between the tanks. Strap consisted of thick wire hose clamped to metalic piping on either side of fill hose.
Fire Fighting
Issued 30 June 2000 Resolved
Seal pedal area at operating station and deck area just aft of operating station for fuller seal in conjunction with FE241 fire extinguishing systembelow deck.
Condition: Unknown
Due 30 June 2000
Resolved 30 June 2000
Lifesaving
Issued 30 June 2000 Resolved
flare expired APR00.
Condition: Unknown
Due 3 July 2000
Resolved 6 July 2000
Documentation
Issued 30 June 2000 Resolved
post emergency checkoff list.
Condition: Unknown
Due 3 July 2000
Resolved 6 July 2000
Construction/Loadline
Issued 30 June 2000 Resolved
portable bilge pump not on board.
Condition: Unknown
Due 3 July 2000
Resolved 6 July 2000
Fire Fighting
Issued 30 June 2000 Resolved
missing BII portable fire extinguisher
Condition: Unknown
Due 3 July 2000
Resolved 6 July 2000
Engineering
Issued 30 June 2000 Resolved
missing markings for emergency fuel shutoff.
Condition: Unknown
Due 3 July 2000
Resolved 6 July 2000
Electrical
Issued 2 June 1998 Resolved
INSTALL MISSING BATTERY COVER.
Condition: Unknown
Due 2 July 1998
Resolved 22 June 1998
Documentation
Issued 2 June 1998 Resolved
POST STABILITY LETTER ON VSL.
Condition: Unknown
Due 2 July 1998
Resolved 22 June 1998
Fire Fighting
Issued 28 August 1997 Resolved
Install fixed fire extinguishing and fire detection systems in engine compartment IAW 46 CFR 181.400 (a) and (b) (5).
Condition: Unknown
Due 28 August 1997
Resolved 28 August 1997
Construction/Loadline
Issued 28 August 1997 Resolved
Remove "marine tech" and doublers from hull in area of shaft tunnel.
Condition: Unknown
Due 28 August 1997
Resolved 28 August 1997
Accommodation/Occupational Safety
Issued 28 August 1997 Resolved
Install 39.5 inch deck rail IAW 46 CFR 177.900 (c) (1).
Condition: Unknown
Due 28 August 1997
Resolved 28 August 1997
Lifesaving
Issued 30 June 1997 Resolved
CONDUCT EMERGENCY DRILLS IN THE PRESENCE OF AN ATTENDING MSO PITTSBURGH INSPECTOR.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Documentation
Issued 30 June 1997 Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE CHEMICAL TESTING REGULATIONS CONTAINEDIN 46 CFR PART 16.
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.