Records from 1997 to 2026. Most recent: inspection, 20 June 2026.
Inspection history · 174
20 June 2026
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8410339
2 May 2026
PSC B · COC-CVE Quarterly
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8358826
8 November 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8265981
8 November 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8267283
3 November 2025
PSC A · COC-CVE Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8260524
26 April 2025
COC-CVE Quarterly · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8120232
6 March 2025
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8089687
23 November 2024
COC-CVE Annual · PSC A
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8034250
20 July 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7962718
4 May 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7903163
10 October 2023
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7805820
3 March 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7646086
22 February 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7640107
26 January 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7627945
4 December 2022
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7603056
26 November 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7599702
24 September 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7565370
16 September 2022
Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7560271
10 September 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7557794
28 August 2022
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7545430
8 August 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7528344
6 August 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7529724
22 April 2022
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7436233
23 March 2022
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7420060
28 February 2022
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7402986
25 February 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7402082
28 January 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7387239
10 December 2021
PSC A · COC-CVE Annual · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7365802
7 May 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6949622
4 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6935467
2 March 2020
PSC B · COC-CVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6915586
6 September 2019
ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6804747
15 April 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6662621
20 March 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6646185
15 March 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6643004
11 March 2019
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6636353
4 March 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6635793
23 October 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6659183
15 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6563544
11 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6559514
13 September 2018
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6540520
13 June 2018
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6443532
12 June 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6442067
1 June 2018
MARPOL Annex VI Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6443579
19 March 2018
ISPS III Exam · COC-CVE Annual · Deficiency Check · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6373265
20 September 2017
COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6270718
5 June 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6166557
28 March 2017
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6113118
13 March 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6103549
13 March 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6103627
10 February 2017
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6086088
14 November 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6040412
1 November 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6033243
17 October 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6023670
30 September 2016
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6010300
9 May 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5872313
3 May 2016
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5868279
15 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5855032
8 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5849831
31 March 2016
Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5844291
8 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5829062
5 February 2016
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5812723
16 October 2015
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5744103
2 October 2015
ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5732667
2 October 2014
Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4997249
21 March 2014
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4820430
6 June 2012
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4335722
5 June 2012
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4334606
11 May 2012
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4308166
11 May 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4308381
27 February 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4252159
26 February 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4251232
18 February 2012
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4247126
18 February 2012
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4247923
11 September 2011
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4143155
13 August 2011
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4110507
28 July 2011
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4097495
28 July 2011
Spot Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4097506
4 February 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3943699
27 December 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3916380
14 October 2010
ISPS III Exam · COC-CVE Quarterly
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3868058
7 October 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3865285
23 March 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3746038
21 July 2009
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3541792
21 July 2009
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3551579
16 July 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3537581
24 April 2009
ISPS II Exam · Ballast Water Examination · COC-CVE Annual · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3459609
13 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3344192
23 June 2008
COC-CVE Annual · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3242316
29 April 2008
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 3195306
21 March 2008
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 3169041
12 January 2008
MARPOL Annex I Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3128906
29 December 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3123784
15 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3098881
15 November 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3106484
4 October 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3075763
3 October 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3073691
20 September 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3072521
17 September 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3071318
17 July 2007
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 2999114
16 July 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3001377
1 July 2007
COC-CVE Annual · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2979295
15 May 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2930975
5 April 2007
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2903033
10 January 2007
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2853741
25 August 2006
Administrative Inspection · Random ISPS/MTSA/PSC
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2759211
14 August 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2750683
31 July 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2731474
3 July 2006
COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2702089
23 May 2006
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2656939
6 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2579929
30 January 2006
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2575745
11 October 2005
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2512227
29 August 2005
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2478686
21 August 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2469542
10 August 2005
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2459585
28 July 2005
Random ISPS/MTSA/PSC
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2442770
21 July 2005
Type not recorded
No type recorded · Sector Field Office Southwest Harbor · USCG Northeast District (CGD-NE) · Activity 2434372
14 July 2005
Type not recorded
No type recorded · Sector Field Office Southwest Harbor · USCG Northeast District (CGD-NE) · Activity 2426621
1 July 2005
COC-CVE Initial · Ballast Water Examination · COC-CVE Annual · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2409954
25 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2342986
18 April 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2337088
12 April 2005
Type not recorded
No type recorded · Activities Europe · Activity 2344661
7 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2305011
17 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2243061
9 November 2004
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2237474
23 September 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2202959
26 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2177606
25 August 2004
COC-CVE Annual
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2176332
12 June 2004
MTSA/ISPS Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2095847
12 May 2004
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2064599
26 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2054885
9 April 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2040594
25 March 2004
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2056178
1 March 2004
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2015161
3 November 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1941269
15 September 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1905118
8 September 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1899611
28 August 2003
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1889963
17 July 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1849163
3 July 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1833897
11 May 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1790958
6 March 2003
Quarterly Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1753491
5 September 2002
Control Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1670005
16 June 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1631627
1 May 2002
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1611387
7 March 2002
MARPOL Annex I Examination · Quarterly Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1490730
31 January 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1482911
19 January 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1480048
6 September 2001
Control Verification · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1439269
22 July 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 103677
14 June 2001
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1420538
18 March 2001
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1362041
5 October 2000
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 65067
5 October 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405054
7 September 2000
MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1413798
15 June 2000
MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466148
12 March 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1047618
16 December 1999
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1361268
9 September 1999
MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1424805
17 June 1999
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466620
14 March 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384068
11 March 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1884
13 December 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1472012
10 September 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 420302
10 September 1998
MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1419993
14 June 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1465974
24 May 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 475399
15 March 1998
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1375302
4 January 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1457524
14 December 1997
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781983
20 September 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 519676
20 September 1997
Control Verification · MARPOL Annex I Examination · Sanitary Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1454472
27 June 1997
Type not recorded
No type recorded · Activities Europe · Activity 784200
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 November 2025
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other
equivalent material. PSCO observed fire doors 00009 and 103l had unsealed screw holes in door. Fire doors 00043 and 1031 did not latch.
74SOLAS(97) II-2/30.2; 17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2025
Resolved 3 November 2025
Resolution: FPVE witnessed doors adjusted and securely latching. hole sealed with bolts as intended.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 November 2025
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed life raft crew 17 did not adequately demonstrate releasing life raft at life raft launching station 19.
74SOLAS(20)III/19.2.1; 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2025
Resolved 3 November 2025
Resolution: FPVE witnessed drill reconducted after training provided to all required crew.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 November 2025
Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and life raft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed, other than machinery spaces. PSCO observed blocked escape route
in garbage room.
74SOLAS(97) II-2/28.1; 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 November 2025
Resolved 3 November 2025
Resolution: FPVE witnessed escape route cleared.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 November 2025
Resolved
Maintenance, testing and inspections shall be carried out in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed accommodation fire damper 56l8.4.152 did not close completely using remote operation and high fog nozzle near fire door 09002 on deck 9 windjammer lacked ampule fluid and was bent.
74SOLAS(20)II-2/14.2.2.1; 10 c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 November 2025
Resolved 3 November 2025
Resolution: FPVE witnessed damper adjusted to operate as intended and new high fog nozzle installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 November 2025
Resolved
In interior locations in passenger ships carrying more than 36 passengers fire hoses shall be connected to the hydrants at all times. PSCO observed missing firehose in locker 111.
74SOLAS(97)/II-2/4.7.1; 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 November 2025
Resolved 3 November 2025
Resolution: FPVE witnessed hose installed at location.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 26 April 2025
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Second in command for lifeboat 13 was unable to demonstrate how to release lifeboat from falls.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2025
Resolved 26 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2025
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO observed fire doors F.D.08025 and F.D.03013 would not latch closed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 April 2025
Resolved 26 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 April 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed leaking fresh water pipe at an installed patch in the STBD compressor/chiller room.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 26 April 2025
Resolved 26 April 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 April 2025
Resolved
Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed, other than machinery spaces. PSCO observed room in a room arrangement in main galley on deck 5 where communicable opening covered by paper blocking the means of immediate and clear notification of fire in the surrounding space.
Action required: 10 - Deficiency Rectified
Due 26 April 2025
Resolved 26 April 2025
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 6 March 2025
Resolved
74SOLAS(01)1/11(a)
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Vessel reported a full loss of power to the Sector Command center.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 6 March 2025
Resolved 10 March 2025
Resolution: Verified satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 November 2024
Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention within 2 min an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control stations and machinery spaces of category A. PSCO observed inoperable call point C0625, located on deck 2.
74 SOLAS (01) II-2/13.1.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 November 2024
Resolved
Fire doors in main vertical zone bulkheads and stairwa enclosures shall be self-closing and shall have an approximately uniform rate of closure of no more than 40 s and no less than 10 s. PSCO observed FSD 06019, 01083, 02015, 04034, 04033, 06010 and 07028 closing too fast. PSCO also observed FSD 07030 and 03046 failed to close all the way.
74 SOLAS (97) II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 November 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are inteded and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed the starboard engine machinery guard in lifeboat #4 was unscrewed and loose, resulting in a unsafe condition for crew.
74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 November 2024
Resolved
The arrangements for the storage, distribution and utilization of oil used shall be such as to ensure the safety of the ship and persons onboard. PSCO observed build up in fuel oil in engine compartment of Lifeboat #4.
74 SOLAS (97) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2024
Resolved
Each section of sprinklers shall be capable of being isolated by one stop valve only. The stop valve in each section shall be readily accessible and its location shall be clearly and permanently indicated. Means shall be provided to prevent the operation of the stop valves by any unauthorized person. The PSCO observed section valve unsecured and operable by unauthorized personnel.
74 SOLAS (97) II-2/12.2.2
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2024
Resolved
All waste-receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO observed combustible trash stored in a combustible can located in the crew galley.
74 SOLAS (97) II-2/18.5
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 November 2024
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. PSCO observed both port and stbd emergency exits in Viking Lounge leading to the outer decks to be locked out, closed, and unable to open.
74 SOLAS (97) II-2/28.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 November 2024
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. PSCO observed stowage of combustible materials behind an electrical panel in laundry room, and combustible trash stored in a combustible can in the crew galley.
74 SOLAS (97) II-2/26.2.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024
Resolution: Corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 4 May 2024
Resolved
Crew members shall receive instruction on fire safety on board the ship. PSCO observed lack of sufficient knowledge from crew members in galley on local activation of water mist system over deep fat fryer.
74 SOLAS 20 II-2/15.2.1.2
17ac
04117
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2024
Resolved 4 May 2024
Resolution: Crew members received appropriate training on deep fat fryer fire suppression
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed loose and inoperable emergency steering gear valve in lifeboat #5.
74 SOLAS 20 III/20.2
17ac
11129
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2024
Resolved 4 May 2024
Resolution: Emergency steering gear valve was tightened, tested, and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed inoperable emergency fuel shutoff valves in lifeboats 5, 7, 9, 15.
74 SOLAS III/20.2
17ac
11129
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2024
Resolved 4 May 2024
Resolution: Emergency fuel shutoff valves were loosened, tested, and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 May 2024
Resolved
Each survival craft shall be stowed in a state of continual readiness so that two crew can carry out preparations for the embarkation and launching in less than 5 minutes. PSCO observed port engine in #3 lifeboat inoperable.
74 SOLAS 97 III/13.1.3
17ac
11129
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2024
Resolved 4 May 2024
Resolution: Replaced the port engine battery and battery relay. Engine was started, tested, and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 May 2024
Resolved
Each crew member with emergency duties shall be familiar with these duties before the voyage begins. PSCO observed crew member on lifeboat #15 display inability to operate aft bilge pump. Commander of lifeboat #8 was not familiar with the location of engine battery switch and therefore could not start lifeboat. Second commanders in lifeboats #3 and #5were not familiar with emergency steering procedures. Commander of lifeboat #16 did not know location of emergency fuel shutoff.
74 SOLAS 20 III/9.2.1
17ac
11131
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2024
Resolved 4 May 2024
Resolution: Crew was given immediate training and were subsequently able to perform their duties satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 May 2024
Resolved
Steering gear control shall be provided for the main steering gear, both on the navigation bridge and in the steering gear compartment. PSCO observed local non-follow up control for each port and starboard steering gear pump solenoid valves inoperable due to modification of design.
74 SOLAS 81 Amendments II-1/29.7.1
17ac
02105
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2024
Resolved 4 May 2024
Resolution: Modified levers used to activate solenoid valves were re-installed securely, steering gear was tested using local NFU's and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2024
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. PSCO observed an arcade office within the deck 10 ocean adventure arcade to be without a safe escape route to a stairway, nor an acceptable means to notify crew of a fire in the surrounding space.
74 SOLAS 97 II-2/28.1.2
16ac
07120
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2024
Resolved 4 May 2024
Resolution: Office space was emptied, all office furniture and supplies were taken from the room, space categorization is being reviewed by class and administration.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures, remote-controlled sliding or power-operated doors shall be equipped with an alarm that sounds at least 5s but no more than 10s before the door begins to move and continues sounding until the door is completely closed. PSCO observed the alarm on the fire door 07031 inoperable.
74 SOLAS 97 II-2/30.4.2
10ac
07105
Action required: 10 - Deficiency Rectified
Due 4 May 2024
Resolved 4 May 2024
Resolution: Door alarm was fixed, tested, and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 May 2024
Resolved
In addition to the emergency lighting, the means of escape, including stairways and exits, shall be marked by lighting of photoluminescent strip indicators placed not more than 0.3m (300mm) above the deck at all points of the escape route including angles and intersections. The marking must enable passengers to identify all the routes of escape and readily identify exits. PSCO observed emergency exit signs in arcade on deck 10 and in casino on deck 5 pointing in the wrong direction.
74 SOLAS 97 II-2/28.1.10
10ac
07120
Action required: 10 - Deficiency Rectified
Due 4 May 2024
Resolved 4 May 2024
Resolution: Exit signs were adjusted to indicate the correct direction of escape.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 December 2022
Resolved
Where the emergency source of electrical power is a generator it shall be provided with a transitional source of emergency electrical power. A malfunction in the inverter prevented the transitional source of power from connecting to the emergency switchboard, rendering it inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 December 2022
Resolved 4 December 2022
Resolution: Damaged UPS/Inverter was replaced and the transitional source of power was load tested for 30 minutes.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 December 2022
Resolved
Any required automatic sprinkler shall be capable of immediate operation at all time. Sprinkler nozzle by FD 01L15 was blocked by a ceiling cover.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 December 2022
Resolved 4 December 2022
Resolution: Sprinkler nozzel was unistalled to allow the Ceiling pannel to be fixed. Sprinkler was re-installed and was put back in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2022
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD.
PSCO WAS INFORMED BY THE PILOT ONBOARD THAT THE VESSEL HAD SUFFERED A LOSS OF PROPULSION DUE TO AN ELECTRICAL MALFUNCTION OF THE STARBOARD SIDE ENGINE.
74SOLAS(04)I/11a
Action required: 60 - Rectify deficiencies prior to movement
Due 16 September 2022
Resolved 16 September 2022
Resolution: Received report no. 1793459-1 from DNV. It is reported that the starboard propulsion failed due to an excitation overcurrent alarm. The crew replaced a damaged capacitor on the excitation diode. Propulsion tested satisfactory in DNV surveyor presence.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 April 2022
Resolved
11199- Other 9 Life Saving)- Partially enclosed lifeboats... shall be fitted with a permanently attached foldable canopy... The canopy shall so arranged that: the occupants can escape in the event of the lifeboat capsizing. Seven lifeboats were observed to be modified whereby the canopy was secured in multiple additional locations due to damage to the attached hoop-to-frame mounting, restricting the ability to quickly open the enclosure in the event of capsizing. SOLAS 97 III/42
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 25 April 2022
Resolved 25 April 2022
Resolution: Removed lines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 April 2022
Resolved
11101- Lifeboats- A manually controlled lamp visible on a dark night with a clear atmosphere at a distance of at least 2 miles for a period of not less than 12 h shall be fitted to the top of the over or enclosure. The manually controlled lamp on lifeboats number 11 and 13 were broken free of their mounts and hanging loosely. SOLAS 97 III/41.7.10
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
Resolution: Lamp was correctly mounted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 December 2021
Resolved
02199 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present reggulations. PSCO's observed cracked and deteriorated stairs on Deck 9 Zone 5 port side and Deck 10 Zone 6 starboard side aft.
74SOLAS(20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2021
Resolved 10 December 2021
Resolution: Received Class Survey Report rectifying this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 2 March 2020
Resolved
THE NORMAL EQUIPMENT OF THE LIFEBOAT SHALL CONSIST OF A FOOD RATION TOTALLING NOT LES THAN 10,000 KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMMODATE; THESE RATIONS SHALL BE KEPT IN AIRTIGHT PACKAGING. PSCOS OBSERVED 50+ FOOD RATIONS THAT WERE NOT HERMETICALLY SEALED.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 2 March 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 March 2019
Resolved
07199 - Fire Safety - Crew members shall be trained to be familiar with the arrangements of the ship and operation of any fire fighting systems that they may be called upon to use. Galley staff members were not familiar with the operation of the fixed fire fighting systems. - 74 SOLAS 14 Con. II-2/15.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2019
Resolution: Conducted questioning of ships galley crew members. Found to be all sat with fire fighting procedures. Cleared deficency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 March 2019
Resolved
07105 - Fire Safety - Fire doors in main vertical zones bulkhead & stairway enclosures shall have an approximate rate of closure of no more than 40s and no less than 10s. The following fire doors did not meet the required rate of closure: FD01082, FD1073, FD1083, FD1098, FD02051, FD09004, FD09003, FD09001. - 74 SOLAS 97 Con. II-2/30.4.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 March 2019
Resolved
07105 - Fire Safety - Fire doors in main vertical zone bulkheads & stairway enclosures of remote-control sliding or power operated door designed to reopen upon contacting an object, shall re-open to allow clear passage of at least 0.75m but no more than 1m. The following doors did not comply with the requirements of this regulation: FSD1036, FSD05015, FSD06014, FSD06016, FSD06020. - 74 SOLAS 97 Con. II-2/30.4.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 March 2019
Resolved
11101 - Lifeboats - Life saving appliances shall be in working order and ready for immediate use. The portside forward seat in LB#3 was not secure. The forward and upper hatch on LB#3 was not in serviceable condition. The bilge pump switch on LB#3 was not present. Excess oil was in the bilge for LB# 2&4. The window gaskets in LB#1 were various states of disrepair. The safety rails on LB#1 could not be secured. Fire extinguishers for the engine rooms on LB#1 were not suitable secured. - 74 SOLAS 14 Con. III/20.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2019
Resolution: See narrative and special note
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 March 2019
Resolved
07105 - Fire Safety - The construction of all doors & door frames in "A" Class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame. The following "A-60" Fire Doors were observed with holes, wastage; and would not prevent the passage of flame and smoke. FD00043, FD00044, FD00045, FDTT016 - 74 SOLAS 97 Con. II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2019
Resolution: Class issued condition for replacement
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 11 March 2019
Resolved
04104 - Emergency Systems - In addition to the emergency lighting required by regulations II-1/42 & III/11.5, the means of escape including stairways and exits, shall be marked by lighting or photo luminescent strip indicators placed not more than 0.3m above the deck at all points of the escape route. Photo luminescent strip indicators were blocked on both bulkheads of "Parliament Street" on the bulkhead deck. - 74 SOLAS 97 Con. II-2/28.1.10
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 March 2019
Resolved
11131 - Life Saving Appliances - The person in charge of the survival craft shall see the crew under his command are acquainted with their duties. Crew members on lifeboats #4,#7, & #13 were unfamiliar with their duties and emergency procedures. - 74 SOLAS 97 Con. III/10.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 March 2019
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 March 2019
Resolved
07111 - Fire Safety - A fireman's outfit shall have an axe. During the fire drill, firefighters outfits did not have axes. - 74 SOLAS 97 Con. II-2/10.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 March 2019
Resolution: Vessel's Safety Officer and Captain were briefed on the requirements of the Fireman's outfit. Vessel had onboard the required axe, however, they did not have them on their person during the observed fire drill.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 March 2019
Resolved
11117 - Life Saving Appliances - Before the ship leaves and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The safety inspection plug on a deck 10 port side lifebuoy was wasted, rendering it unserviceable. - 74 SOLAS 14 Con. III/20
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 March 2019
Resolution: Vessel replaced the lifebuoy with new.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2019
Resolved
02108 - Structural Conditions - electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Open dead end wires were in the welding workshop, port and starboard steering room, incinerator room, and the hydraulic room provisions platform. - 74 SOLAS 04 Con. II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 March 2019
Resolution: Vessel corrected the dead end and open wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 September 2018
Resolved
02108- Electrical Installation in General - Cables and wiring shall be installed and supported to avoid chafing or other damage. Temporary blowers are installed over incenerators with multiple extensions cords and surge protector. 74SOLAS 04Cons II-1/45.5.5
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2018
Resolution: Vessel repaired/installed insulation in the approriate locations. [name withheld] attested to the repairs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 September 2018
Resolved
07101- Fire Prevention structural integrity- The minimum fire integrity of all bulkhead shall be as prescribed in table 26.1. Sections of structural fire protection insulation are missing in following areas. Forward L1 stairway near tanktop, Near FSD 04.003, Pool/Jacuzzi maintenance room near RM 8570, AC Maintenance 0071. 74SOLAS 97 cons II-2/26.1.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 October 2018
Resolution: Vessel installed the insulation in the appropriate locations. [name withheld] attested to the repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 17 September 2018
Resolved
11101 - Lifeboats - Before the ship leaves port and at all time during voyage, all lifesaving appliances shall be in working order and ready for immediate use. Raw water cooling line clamps on both engines on lifeboat 1 were missing. 74SOLAS 97 Cons CH III Reg 19.2
Action required: 10 - Deficiency Rectified
Resolved 17 September 2018
Resolution: Ships Engineering personal rectified the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 17 September 2018
Resolved
11101 - Lifeboats - On a weekly basis all engines in lifeboats shall be run for a total period of not less than 3 min. Lifeboats 1,2,3 and 4 are not being run on a weekly basis. 74SOLAS 97 Cons CH III Reg 19.6.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2018
Resolution: Cleared by Classification Society
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 September 2018
Resolved
07199 - Fire Safety Other - Crew members shall be trained to be familiar with the arrangements of the ship and operation of any fire fighting systems that they may be called upon to use. Galley staff members were not familiar with operation of fixed firefighting systems. 74SOLAS 14 cons Ch II-2 Reg 15.2.2.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2018
Resolution: Vessel conducted appropriate training with crewmembers
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 September 2018
Resolved
03199 - Other Load Line - The ring, lines, and letters shall be painted in contrasting color to the background. The deck line was painted the same color as the hull. ICLL Chapter 1 reg 8
Action required: 10 - Deficiency Rectified
Resolved 17 September 2018
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 19 March 2018
Resolved
0750 - Fire Prevention - A class divisions are those divisions formed by bulkheads and decks and shall be constructed of steel and capable of preventing the passage of smoke and flame. Escape route leading for engine room in way of FD 00047 has cutout in steel. - 74SOLAS(1997)II-2/3.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 2 April 2018
Resolution: Class surveyor attended vessel and verified satisfactory correction of deficiency.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 19 March 2018
Resolved
0750 - Fire prevention - The construction of all doors and door frames in A class divisions shall provide resistance to fire as well as to the passage of smoke and flame. FD TT016, TT019, TT014, TT008 and TT009 do not provide adequate seal. - 74SOLAS(1997)II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 2 April 2018
Resolution: Class surveyor attended vessel and verified satisfactory correction of deficiency.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 March 2018
Resolved
0750 - Fire Prevention - Fire doors in main vertical zone bulkheads and stairway enclosures shall be equipped with an alarm that sounds at least 5 seconds but no more than 10 seconds before the door begins to move. FD 01036, 01045, 04027 do not begin moving until after 10 seconds. - 74SOLAS(1997 cons)II-2/30.4.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 2 April 2018
Resolution: Class surveyor attended vessel and verified satisfactory correction of deficiency.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 September 2017
Resolved
The hotel maintenance storage space, deck 4 fwd, is not constructed in accordance with the fire control plan. The vessel added a wall and door between the office and storage space. 74 SOLAS (97 CONS) Ch II-2/Reg 20.1
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2017
Resolved 25 September 2017
Resolution: The wall that was added to the office in the hotel storage was removed and class, DNV GL, onboard confirmed it no longer an issue.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 31 March 2017
Resolved
The rudder and tiller shall be so arranged as not to be damaged by operation of the propeller. Lifeboat #17 rudder has temporary repairs due to damage caused by the propeller. 74 SOLAS (1997 Cons) III/41.7.7.2
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 11 April 2017
Resolution: Received Class Attestation to proper correction of deficiency.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 February 2017
Resolved
Identified temporary electrical power arrangements runnung through bulkheads, doors, and hatches compromising the integrity of A class boundaries. 17ac 74Solas(14)ch1/Reg11(b)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2017
Resolved 10 February 2017
Resolution: Temporary electrical power arrangements were moved to pass through adeqaute penetrations in bulkheads. Received class report from DNV attesting to correct method used, and attended the vessel to verify compliance.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 30 September 2016
Resolved
The transitional source of emergency electrical power shall consist of an accumulator battery which shall operate while maintaining the voltage of teh battery throughout the discharge period within 12 percent above or below its nominal voltage. When testing transitional power during the vessel's scheduled PSSC by Class, the batteries failed the 30-minute nominal voltage test.
Action required: 705 - Other - as specified
Due 13 November 2016
Resolved 14 November 2016
Resolution: Received Class report and verified new batteries on board.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 September 2016
Resolved
Lifejackets shall be so placed as to be readily accessible and their position shall be plainly indicated. Where, due to particular arrangements of the ship, the lifejackets provided are in compliance with the requirement. Numerous passenger state rooms, including but not limited to romms 2510, 2592, 3095, and 3082, where found without lifejacket position not plainly indicated.
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 11 October 2016
Resolution: Received DNV-GL Survey Statement clearing the life jacket deficiency.
Fire Fighting › Fire Hoses › Condition
Issued 8 April 2016
Resolved
Fire hose on fire station 20 was leaking and not ready for service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 April 2016
Resolved 8 April 2016
Resolution: corrected on the spot
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 8 April 2016
Resolved
Exit signs at fire door TT024 and WTD TT8 are in need of repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 15 April 2016
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 8 April 2016
Resolved
The escape ladder on Dk 4 inside casing stbd side is blocked by newly installed scrubber system piping.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 22 April 2016
Resolution: Area in question not part of required escapes. Markings removed. Cleared.
Fire Fighting › Water Fog Applicators › Location
Issued 8 April 2016
Resolved
Newly installed scrubber system piping is blocking or restricting water flow of high fog nozzles in the funnel casing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 22 April 2016
Resolution: Received minimum required clearance info from vendor - nozzles installed correctly. Cleared
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 April 2016
Resolved
A section of SFP was found missing in the DK 10 Fan room stbd side.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 15 April 2016
Electrical › Electrical Distribution System (service) › Busway
Issued 8 April 2016
Resolved
Wire trays were found wasted on Decks 2 and 3 stbd side in funnel casing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2016
Resolved 15 April 2016
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 8 April 2016
Resolved
Compressed gas cylinders in ships main storage location were not secured properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 15 April 2016
Construction/Loadline › Structures › Door
Issued 8 April 2016
Resolved
The weathertight door to AC room 0106A is warped and does not function as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2016
Resolved 15 April 2016
Electrical › Electrical Distribution System (emergency) › Outlet Box
Issued 8 April 2016
Resolved
The alarm indicator in the funnel casing DK 8 has exposed internal wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2016
Resolved 15 April 2016
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 April 2016
Resolved
0987- Bulkheads cracking - The ship shall maintained to conform with the present regulations and in all respects fit to proceed to sea. Fire screen doors 00044 and 00045 frames are fractured trough the bulkhead.Solas 97 Cons Ch 1 Reg 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 15 April 2016
Engineering › Steam System (auxiliary) › Piping
Issued 1 April 2016
Resolved
0999- Other Safety General- 0987- Bulkheads cracking - The ship shall maintained to conform with the present regulations and in all respects fit to proceed to sea. Steam line is leaking over 440 panel in way of sea valve 48. Solas 97 Cons. Ch-1 Reg 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 April 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 April 2016
Resolved
1099 - Other (alarm)- All electrical apparatus shall be installed as not to cause injury when touched in the normal manner. Sprinkler system release apparatus (BF-24L) outside the forward AC room was broken. 74 Solas (97 Cons) II-I Reg 45/1.3
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 8 April 2016
Resolution: corrected
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 1 April 2016
Resolved
All electrical apparatus shall be installed as not to cause injury when touched in the normal manner.08 electrical receptacles covers were missing. 74 Solas (97 cons) II-I Reg 45/1.3
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 15 April 2016
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 October 2015
Resolved
All doors in "A" class divisions shall provide resistance to the passage of smoke and flame. Fire screen doors F.D.06R03 & F.D.06R04 allowed excessive smoke to pass through while closed and secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 October 2015
Resolved 16 October 2015
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 October 2014
Resolved
Fire doors shall be designed so that the door will automatically close in the event of the disruption of control system or central power supply. Fire doors No.20404 / 02407 and 02051 did not fully close. 74 Solas (04) II-2/ 9.4.1.1.4.7
Due 3 October 2014
Resolved 3 October 2014
Resolution: All doors adjusted and corrected at the spot.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 7 May 2012
Resolved
During scheduled crew emergency drill and lifeboat lowering, Three starter motors were damaged on lifeboats #5, 7 and 15. Lifeboat engines cannot be started until new starter motors are installed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 May 2012
Resolved 11 May 2012
Resolution: Conducted deficiency check of lifeboats #5, 7 and 15. Starter motors replaced by crew. Inspected starter keys on lifeboats #5, 6, 7, 8, 16, 15. Inspected Tender Motors and starting keys. Test ran Lifeboats #5, 7, 15 all test satisfactory.
Engineering › Electric Propulsion System › Winding
Issued 18 February 2012
Resolved
Vessels port propulsion motor sustained a short between two poles of the rotor resulting in charred and damaged poles rendering port propulsion motor inoperative.
Action required: 705 - Other - as specified
Due 18 February 2012
Resolved 19 February 2012
Resolution: Received DMV class report stating that Port Motor restored to 70% capability. Permenant repair will be completed at next drydock on about Dec 2012.
Stability › Watertight Integrity › General
Issued 24 April 2009
Resolved
Watertight door TT06's motor is burnt out. Door is able to close manually. Door required to remain shut at all times until repairs are complete.
Action required: 705 - Other - as specified
Due 27 May 2009
Resolved 22 October 2009
Resolution: Class survey report observed.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 29 December 2007
Resolved
Rescue boat is not in proper working order and ready for immediate use due to damages of the engine and hull. Lifeboat #11 is designated as a rescue boat and emergency plans are updated as necessary.
Action required: 705 - Other - as specified
Due 29 January 2008
Resolved 23 June 2008
Resolution: Def corrected
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 15 November 2007
Resolved
Transformer failure on STBD side of the main switchboard, resulted in loss of power to STBD propulsion system.
Action required: 705 - Other - as specified
Due 30 December 2007
Resolved 23 June 2008
Resolution: Def corrected
Engineering › Generator (propulsion-electric) › Charger
Issued 9 October 2007
Resolved
Turbo charger must be repaired within 30 days on the #1 generator.
Action required: 705 - Other - as specified
Due 5 November 2007
Resolved 12 January 2008
Resolution: Def corrected
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 4 October 2007
Resolved
The control pannel on the vessel had shorted out due to a leak in the grey water pipe overhead of the switchboard.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2007
Resolved 4 October 2007
Lifesaving › Lifeboat › Propeller Shaft
Issued 16 July 2007
Resolved
#14 Lifeboat has a stern tube has 5 cm crack. Temp repairs made with fiberglass tape and resin.
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 12 January 2008
Resolution: def corrected
Lifesaving › Lifeboat Equipment › Food Ration
Issued 5 April 2007
Resolved
Vsl needs to replace all expired food and water rations on board all tenders and lifeboats by April 9, 2007. Vsl currently replaced vsl's expried water with potable water in tanks of lifeboats until Monday's delivery. The vsl was given permission to sail with the 1 month expired food until the 9th.
Action required: 705 - Other - as specified
Due 9 April 2007
Resolved 7 May 2007
Resolution: All expired food was replaced
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 April 2007
Resolved
Recommended ISM Audit: Not a deficiency
Due 4 May 2007
Resolved 5 April 2007
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 April 2007
Resolved
As per SMS, vsl needs to ensure monthly lifesaving equipment reports are addressed to the satisfaction of class when applicable.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 7 May 2007
Resolution: Monthly PMS was conducted and reports were submitted to the Coast Guard
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 10 January 2007
Resolved
DIscovered combustible storageitem in AC spaces: 022A, 075A, and 07605A
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 February 2007
Resolved 5 April 2007
Resolution: Deficiency rectified
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 January 2007
Resolved
Emergency exit light in the chop grill dinning room aft was found extinguished
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 11 February 2007
Resolved 5 April 2007
Resolution: Corrected and verified by CG inspectors.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 January 2007
Resolved
listed fire screen doors were found not functioning properly 1034, 4011, 10006, 06r02, and all grill chop dining room doors.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 February 2007
Resolved 5 April 2007
Resolution: CG inspectors verified proper function of above mentioned FSD''''s.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 January 2007
Resolved
Fire doors 5002 and 5003 were found inoperative 5003 to be repaired proir to departure. 5002 to be manually closed and monitored by hourly security watch to verify doors remain closed. Perminent repairs within 30 days.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 February 2007
Resolved 5 April 2007
Resolution: Repairs were made to all fire doors and verified by CG inspection
Lifesaving › Lifeboat › Capacity
Issued 31 July 2006
Resolved
Vessel had fire onboard lifeboat #3. Replacement will be provided. Have class society fax report when lifeboat is replaced.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 7 May 2007
Resolution: Lifeboat was replaced
Construction/Loadline › Structures
Issued 1 March 2004
Resolved
Several fire screen doors 01098 & 00057do not have a release on each side of the door located by crew's accomodation. Provide release for both sides of doors and check all doors throught the vessel to the satisfatction of the flag state rep. Door from Deck 1 to Incenerator room does not have a lock LEGACY COMPONENT DESC: Door
Due 31 March 2004
Resolved 12 May 2004
Resolution: CLASS REPORT RCVD............ALL SAT
Pollution Prevention/Response › Prevention Equipment
Issued 1 March 2004
Resolved
Relief / Safety valve between pump and oily water separator is not functioning properly. Repair valve and test system to the satisfaction of the flag state rep.
Due 31 March 2004
Resolved 12 May 2004
Resolution: CLASS REPORT RCVD.............ALL SAT
Fire Fighting › Structural Fire Protection - General
Issued 15 September 2003
Resolved
Ship safety officer to provide classification document indicating reason for B15 doors being used in passenger / crewmember stairway deck 0.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 September 2003
Resolution: Cleared on Deck
Construction/Loadline › Structures
Issued 28 August 2003
Resolved
Alarm for FSD 05008 not working. LEGACY COMPONENT DESC: Fire Screen Door Alarm
Due 1 October 2003
Resolved 1 September 2003
Resolution: Corrected and verified by the Class Society.
Operations/Management › Drills/Instruction
Issued 28 August 2003
Resolved
Vessel shall prove proper release of lifeboats on each side of the vessel. LEGACY COMPONENT DESC: Lifeboats
Action required: 705 - Other - as specified
Due 15 September 2003
Resolved 15 September 2003
Construction/Loadline › Structures
Issued 28 August 2003
Resolved
Vessel shall provide magnets on both side of the bulkhead to several FSD missing such arrangement. LEGACY COMPONENT DESC: Dual local release for Fire Screen Doors
Due 26 October 2003
Resolved 26 October 2003
Resolution: Received report from flag indicating that 27 new magnets have been installed and that all are working properly.
Operations/Management › Mandatory Ship Reporting Systems
Issued 31 January 2002
Resolved
Since October 2001, vessel has failed to provide a 24 hour advanced notice of arrival for voyages more than 24 hours in duration. LEGACY COMPONENT DESC: Entry Report
Condition: Unknown
Due 31 January 2002
Resolved 1 May 2002
Resolution: Vessel properly provided 96 Hr. notice to arrival.
Fire Fighting
Issued 14 June 2001
Resolved
Luminescent arrows indicating direction of travel missing on all sliding fire screen doors.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Fire Fighting
Issued 14 June 2001
Resolved
FSD #01073 (Garbage Room Door) jammed shut during testing.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Engineering
Issued 5 October 2000
Resolved
PRIOR TO ARRIVAL FT. LAUDERDALE, NOTIFY MSO MIAMI AS TO PROPULSION STATUS PRIOR TO ENTRY OF PORT. UPON COMPLETION OF FAULT ANALYSIS, PROVIDE REPORT TO COGNIZANT MSO PRIOR TO DEPARTURE.
Condition: Unknown
Due 5 October 2000
Resolved 5 October 2000
Engineering
Issued 4 January 1998
Resolved
PROVE PROPER OPERATION OF PORT MAIN PROPULSION.
Condition: Unknown
Due 4 January 1998
Resolved 4 January 1998
Electrical
Issued 20 September 1997
Resolved
PROVE PROPER OPERATION OF MODIFICATION FOR SPLIT PLANT EMERGENCY DIESEL GENERATOR SET OPERATION. (EMERGENCY POWER CONSISTS OF TWO GENSETS. BOTH SHOULD AUTO-START AND CARRY NECESSARY LOADS.)
Condition: Unknown
Due 20 September 1997
Resolved 20 September 1997
Fire Fighting
Issued 20 September 1997
Resolved
DEVELOP TEST PROCEDURES TO ENSURE PROPER TEST SEQUENCING OF HIGH FOG PUMPS AND DEMONSTRATE SAME.
Condition: Unknown
Due 20 September 1997
Resolved 20 September 1997