07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10...
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Vessel did not have fire extinguisher servicing report completed. 46 CFR 176.810 (b)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 7 October 2025
Resolved 23 October 2025
Resolution: Verified portable fire extinguisher annual service has been preformed to the satisfication of the attending MI.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 7 October 2025
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40... This subpart summarizes the responsibilities of credentialed mariners, marine employers, MRO, SAP and other chemical testing service providers in 49 CFR part 40. The regulations in 49 CFR part 40 should be consulted to determine the specific procedures which must be established and utilized. Drug testing programs required by this part must use only drug testing laboratories certified by the Department of Health and Human Services. OMO did not have a drug and alcohol program. 46 CFR 16.113
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2025
Resolved 31 October 2025
Resolution: DAPI program is in place.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 October 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel's portable battery light in the pilothouse does not turn on and no portable battery light was at the access to the propulsion machinery space. 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2025
Resolved 23 October 2025
Resolution: Vsl has two operable portable battery lights on board to the satisfication of the attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 October 2025
Resolved
A hatch exposed to the weather must be watertight. MI found fwd hatch gasket was not intact. 46 CFR 179.360 (a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2025
Resolved 23 October 2025
Resolution: Verified fwd hatch gasket has been installed to the satisfication of the attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2024
Resolved
Unless otherwise specified, vessel owners must pay the fees required by this subpart before inspection or examination services are provided. The user fees have not been paid for this year.
46 CFR 2.10-20(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2024
Resolution: Verified user fees have been paid.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 September 2024
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. The EPIRB test was not logged. The vessel does not have a log book.
46 CFR 185.728(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: EPIRB tested and logged in new log book.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 25 September 2024
Resolved
A vessel with batteries of adequate capacity to supply the loads specified in paragraph (a)(1) of this section for three hours, complies with paragraph (a)(1) of this section. The radio equipment on the bridge did not operate under loss of power from the generator.
46 CFR 183.310(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2024
Resolution: VHF verified to now be on battery backup.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 September 2024
Resolved
A vessel must comply with the applicable requirements for any radio as set forth in 47 CFR part 80. The radios on board were not set up with Digital Selective Calling as required by FCC. The GPS was not communicating with the VHF radios.
46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: VHF now has GPS input for DSC.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2024
Resolved
All electrical circuits must be clearly marked and identified. AC panel on bridge missing circuit labels.
46 CFR 183.220(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: AC panel now labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2024
Resolved
Wire connectors utilized in conjunction with screw type terminal blocks must be of the captive type. The bilge alarm for rudder room had loose connections that were not of the captive type.
46 CFR 183.340(k)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Connections replaced with captaive type and alarm tested all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2024
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Multiple fuel hoses in the engine room were not J-1942 and showed signs of chaffing.
46 CFR 182.720(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Hoses replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 25 September 2024
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all times. Cotter pins were missing on the main steering gears.
46 CFR 182.610(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Cotter pins installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 25 September 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The main engines had rotating parts that were not protected by guards.
46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Guards put in place.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 September 2024
Resolved
In systems where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. The port raw water hose is missing a clamp.
46 CFR 182.410(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Hose clamp has been repalced.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 25 September 2024
Resolved
All closure devices must be readily available and mounted. The port aft fire damper was not able to close.
46 CFR 182.465(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Fire damper was repaired and MI witnessed proper closure.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 25 September 2024
Resolved
Materials used in piping systems must beet the requirements of this subpart and otherwise be acceptable to the OCMI. The piping for sewage and potable water was found to be un-serviceable in multiple locations.
46 CFR 182.700
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Pipes have been replaced as necessary.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 25 September 2024
Resolved
Individual bilge suction lines must be led to a central control point or manifold. The bilge manifold was not labeled and was unclear which pipes led to which space.
46 CFR 182.510(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Bilge manifold labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 September 2024
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices. The hatch covers for the fore-peak and steering gear compartment did not have a captive chain.
46 CFR 179.360(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Captaive chain replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 September 2024
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Multiple cable penetrations in engine room found not watertight.
46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 25 October 2024
Resolution: Wires secured with firestop.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2024
Resolved
Each lifejacket must be marked with Type I retroreflective material. One lifejacket found with worn retro tape.
46 CFR 185.604(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2024
Resolved 20 November 2024
Resolution: New life jacket purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2022
Resolved
Flexible hoses may be used provided it is fitted with suitable connections / fittings. Repair fuel leak on starboard main engine. 46 CFR 182.20-40(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 January 2022
Resolved 31 January 2022
Resolution: Hoses' fittings were properly installed. Fuel leak was stopped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2022
Resolved
Junction box connection and outlet boxes, for use in damp or wet locations shall be of watertight construction. Install plug in outlet in machinery space. 46 CFR 182.10-20(k)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 31 January 2022
Resolution: Plastic cover was fixed to the rear portion of the outlet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 January 2022
Resolved
Marine inspector shall examine all parts of the vessel machinery to be sure it is satisfactory condition. Starboard reduction gear leaking oil. Fix oil leak. 46 CFR 176.10-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 31 January 2022
Resolution: Oil leak was stopped.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 February 2020
Resolved
A vessel required to have a visual and audible bilge high level alarm in spaces subject to flooding from sea water. Vessel bilge alarm was not operable. Vessel rep must show proof that the bilge alarm is operable.
Action required: 10 - Deficiency Rectified
Due 26 March 2020
Resolved 26 February 2020
Resolution: Attended vessel and saw the bilge high alarm was operational
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 February 2020
Resolved
A vessel is required to have an EPRIB that is operative. Vessel's EPIRB hydrostatic release was expired. Vessel must replace hydrostatic release.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2020
Resolved 28 February 2020
Resolution: Vessel provided proof of new hydrostatic release.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 January 2019
Resolved
Mastheadlight not operational
Action required: 10 - Deficiency Rectified
Due 18 February 2019
Resolved 22 January 2019
Resolution: light replace and operational
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2019
Resolved
Alcohol Test Strips expired
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 January 2019
Resolved 22 January 2019
Resolution: new test strips aquired
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 January 2019
Resolved
Smoke Detector units in Galley and passenger space not operational
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 February 2019
Resolved 22 January 2019
Resolution: smoke detector units replaced
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 17 January 2019
Resolved
Overboard Discharge valve for sewage is unsecured
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 15 February 2019
Resolved 22 January 2019
Resolution: Secured Valve
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 January 2018
Resolved
Provide Alcohol test strips for entire crew.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 25 January 2018
Resolution: Vessel Rep provided all required test strips
Operations/Management › Pollution › Control of Garbage
Issued 25 January 2018
Resolved
Provide proper MARPOL placard.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 25 January 2018
Resolution: Vessel Rep provided new Marpol V Placard
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 January 2018
Resolved
Provide name and hailing port on stern.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 25 January 2018
Resolution: Vessel attached plate with name and hailing port to aft of vessel.
Lifesaving › Lifebuoys › Serviceable
Issued 25 January 2018
Resolved
Provide proper retro tape for life ring.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 25 January 2018
Resolution: New retroflective tape was affixed to lifebuoy
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 3 February 2017
Resolved
Exposed exhaust piping on port engine
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 6 February 2017
Resolution: Exhaust piping on port engine replaced.
Construction/Loadline › Penetrations › Gasket
Issued 3 February 2017
Resolved
Provide proper gasket on rudder room hatch
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2017
Resolution: Gasket on rudder room hatch replaced.
Electrical › Electric Supply System (service) › Cable
Issued 3 February 2017
Resolved
Provide proper wiring in bridge
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 6 February 2017
Resolution: Wiring in bridge corrected.
Construction/Loadline › Structures › Deck Plating
Issued 3 February 2017
Resolved
Provide water tight integrity from Hull/ISE
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2017
Resolution: All water tight integrity issues from Hull/ISE have been corrected.
Engineering › Steering Gear System › Linkage
Issued 28 January 2016
Resolved
Prove satisfactory operation of steering gear system.
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 3 February 2016
Resolution: Recieved Shipyard invoice covering required repairs.
Engineering › Bilge Water Management System › Hose
Issued 28 January 2016
Resolved
Provide satisfactory discharge hose length for hand bilge pump.
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 3 February 2016
Resolution: Recived Picture evidence of sufficent hose length to properly discharge pump
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 28 January 2016
Resolved
Provide satisfactory louvers on port side engine room exhaust opening.
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 3 February 2016
Resolution: vessel rep provided sufficent photographic evidence to clear the deficency