QUIXOTIC is a 1976 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1981, most recently in February 2020, along with 114 deficiencies and 2 casualty investigations between 2006 and 2011.

Records from 1981 to 2020. Most recent: inspection, 19 February 2020.

Built
1976
Last inspected
19 February 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3395
Flag
VIRGIN ISLANDS, BRITISH
366804080, 367067140, 367338540, 367694770 (licence lapsed)
Maury page id
psix-48618

Inspections, by type

…with no type recorded25
Years with a record 33 calendar years (1981–2020)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDI4063MMSI 367694770 · cancelled · compulsorily equipped · granted 1 October 2015, cancelled 1 October 2015
WDE3395MMSI 367338540 · expired · compulsorily equipped · granted 20 February 2008, cancelled 28 April 2018
WDC7161MMSI 367067140 · expired · compulsorily equipped · granted 16 September 2005, cancelled 21 November 2015
WDA3946MMSI 366804080 · expired · compulsorily equipped · granted 17 March 2001, cancelled 21 May 2011
WCQ6452MMSI not assigned · expired · voluntarily equipped · granted 5 April 1995, cancelled 11 June 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TENACITY Passenger (Inspected) · MISLE 46036 · 22 September 2006 · activity 2793462GOL INTRUDER Passenger (Inspected) · MISLE 467990 · 3 May 1998 · activity 109854

Inspection history · 73

19 February 2020 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6916403
13 June 2014 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4891523
22 February 2011 Examination of Repairs · COI Inspection · DAPI Audit · Drydock Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3946012
8 September 2010 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3845285
9 March 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3430115
9 December 2008 Hull Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3372211
14 February 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3147358
18 May 2007 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2933777
18 May 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2933820
6 February 2007 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2868265
29 September 2006 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2789924
22 September 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2793462
17 July 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2716250
7 April 2006 COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2618289
28 April 2005 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2339645
16 December 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2256106
1 April 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2037862
29 March 2004 Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2033623
14 February 2003 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1742366
26 December 2002 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1722363
19 February 2002 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1486788
30 January 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1482616
1 August 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068874
23 February 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387003
23 February 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046852
10 November 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 675427
6 November 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212875
14 August 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437441
3 May 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 109854
10 February 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215024
12 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778821
3 October 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414872
19 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 675428
19 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 717724
19 July 1996 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442430
19 March 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1081490
6 January 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 172014
1 September 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185668
14 February 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357043
2 May 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 106170
28 February 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167849
1 February 1994 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1409071
13 December 1993 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 849101
28 July 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 675429
27 July 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 187048
20 April 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1440688
14 April 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 836092
7 April 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 675426
27 January 1993 Hull Examination · Damage Survey · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1142093
4 January 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 59768
4 January 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 219491
21 July 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432614
6 July 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676530
28 January 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952869
13 January 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268747
23 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923664
1 March 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931173
28 January 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917588
25 January 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232008
15 June 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206671
1 June 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041164
26 January 1989 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1035975
4 February 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325215
20 August 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310631
28 May 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337781
5 February 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308510
6 February 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989783
9 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992864
7 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287805
7 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971330
8 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969169
9 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279818
18 February 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275681

Deficiency record · 114

Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 February 2011 Resolved
Comply with 16.401 49CFR in particular the random drug testing program is not indicated in any documentation.
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 3 October 2011
Resolution: Ref activity 4006977 finished 02Jun2011.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 22 February 2011 Resolved
Training for crews knowledge about the serious marine incident and the requirements for drug and alcohol testing after the incidents.
Action required: 705 - Other - as specified
Due 11 March 2011
Resolved 3 October 2011
Resolution: Ref activity 4006977 completed on 02jun2011.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 9 March 2009 Resolved
Vessel name and Home port not painted on stern
Due 9 April 2009
Resolved 9 April 2009
Resolution: Name and Home Port painted on stern
Navigation › Piloting/Steering › Marine Charts
Issued 9 March 2009 Resolved
Vessel had no chart for area of operation
Due 9 April 2009
Resolved 9 April 2009
Resolution: Charts purchased
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 March 2009 Resolved
Vessel had no current Tide/Tidal Current Tables on board
Due 9 April 2009
Resolved 9 April 2009
Resolution: Tide/Tidal Current Tables purchased
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 March 2009 Resolved
Vessel had no US Coast Pilot pub on board
Due 9 April 2009
Resolved 9 April 2009
Resolution: Coast Pilot purchased
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 March 2009 Resolved
Vessel did not have the most current Coast Guard Light List on board
Due 9 April 2009
Resolved 9 April 2009
Resolution: Coast Guard Light List purchased
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 9 March 2009 Resolved
All Portable Fire Extinguishers on board overdue for service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2009
Resolution: All Portable Fire Extinguishers serviced
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 March 2009 Resolved
Not Under Command Lights not operating
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2009
Resolution: New switch installed for Not Under Command Lights
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 9 March 2009 Resolved
Overcurrent device not working on port generators
Due 9 April 2009
Resolved 9 April 2009
Resolution: Electrician repaired broken wire.
Construction/Loadline › Structures › Door
Issued 9 March 2009 Resolved
Adjust dogs on watertight door to engine room to provide watertight seal
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2009
Resolution: Dogs adjusted to provide watertight seal
Documentation › Certificates/Documents › FCC SSL
Issued 14 February 2008 Resolved
Vessel does not have valid FCC Radio Operator with permit, FCC Station License, and FCC Safety Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 14 February 2008 Resolved
Vessel needs to provide and post Employee Assistance Program placard, Passenger Safety Orientation, and Waste Management Plan.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 February 2008 Resolved
Provide proof of drug and alcohol program enrollment and testing.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 14 February 2008 Resolved
Provide Lifesaving Equipment Maintence Record.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 February 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 February 2008 Resolved
Repair not under command lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Communications › Radio Communications › EPIRB
Issued 14 February 2008 Resolved
Replace/ Renew antenna and hydrostatic release on EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Lifesaving › Lifefloat › Markings
Issued 14 February 2008 Resolved
Life floats need to be stenciled with the vsl name and capacity on both sides.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 February 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 February 2008 Resolved
Port life buoy needs to be stenciled with vsl name and SOLAS tape renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 February 2008
Fire Fighting › Fire Main › Pressure
Issued 14 February 2008 Resolved
Prove 60 P.S.I. on the fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2008
Fire Fighting › Fixed Deck Foam System › Foam Applicators
Issued 14 February 2008 Resolved
Provide semi-portable extinguishers and AFFF for marine portable tanks. Required onboard prior to carriage of marine portable tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2008
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 14 February 2008 Resolved
Replace flame screens on all vents on deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 14 February 2008 Resolved
Replace grease filter on range hood, place cover on light and latch on oven door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Deck/Cargo › Holds/Tanks › Coaming
Issued 14 February 2008 Resolved
Place hard rubber gasket on watertight doors on bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 February 2008 Resolved
Repair rail on aft stbd and place chain on stbd side bridge wing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 February 2008 Resolved
All loose and dead end wiring needs to be secured throughout the vessel.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Deck/Cargo › Holds/Tanks › Coaming
Issued 14 February 2008 Resolved
Replace broken window on bridge and the head in the passenger area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Stability › Weathertight Integrity › General
Issued 14 February 2008 Resolved
Secure through hull penetrations on the bridge throughout.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Stability › Watertight Integrity › General
Issued 14 February 2008 Resolved
Place dog on watertight door in galley.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Engineering › Bilge Water Management System › Piping
Issued 14 February 2008 Resolved
Replace/Repair piping for bilge through crew quarters.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 14 February 2008 Resolved
Pump out excess oil in engine room bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2008
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 14 February 2008 Resolved
Replace exhaust lagging on port engine.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Fire Fighting › Fire Main › Condition
Issued 14 February 2008 Resolved
Weld overhead port side fire main piping.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 February 2008
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 14 February 2008 Resolved
Repair excess salt water leak on stbd exhaust piping.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 February 2008
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 February 2008 Resolved
Replace flexible hose on port side generator.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 February 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 February 2008 Resolved
Place cover on light in engine room stbd side.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 February 2008
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 14 February 2008 Resolved
Repair excess oil leak on return line turbo port main diesel engine.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 14 February 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 February 2008 Resolved
Conduct man overboard drill in presence of marine inspector.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 22 February 2008
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 May 2007 Resolved
46CFR 15.805(a)(4) Failure to have a licensed Master on an inspected small passenger vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2007
Resolved 9 March 2009
Resolution: A licensed Master was on board
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 18 May 2007 Resolved
46CFR67.123 Failure to comply with marking requirements for the vessel's name and hailing port.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2007
Resolved 9 April 2009
Resolution: Name and Home Port were painted on stern
Navigation › Piloting/Steering › Marine Charts
Issued 18 May 2007 Resolved
46CFR184.420 Failure to have current and up to date navigation charts on board for area of operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2007
Resolved 9 April 2009
Resolution: Vsl had navigation charts on board
Documentation › Certificates/Documents › FCC SSL
Issued 6 February 2007 Resolved
FCC Station license was not renewed with the new owner/operator information.
Due 28 February 2007
Resolved 9 August 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 February 2007 Resolved
The EPIRB registration was not updated to reflect new vessel ownership and physical characteristics.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 February 2007 Resolved
Required training, drills and EPIRB checks were not conducted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 February 2007 Resolved
Vessel owner did not have proof of enrollment in a drug and alcohol testing program.
Due 28 February 2007
Resolved 9 August 2007
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 6 February 2007 Resolved
A waste management plan was not implemented.
Due 28 February 2007
Resolved 7 February 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 6 February 2007 Resolved
The emergency lighting in the engine room was not properly wired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 February 2007 Resolved
Life jacket donning placards were not onboard, and no passenger safety orientation information was available.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Navigation › Piloting/Steering › Compass Deviation Table
Issued 6 February 2007 Resolved
A compass deviation table was not onboard.
Due 28 February 2007
Resolved 7 February 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 6 February 2007 Resolved
The dryer did not have a metallic exhaust hose.
Due 28 February 2007
Resolved 7 February 2007
Electrical › Electric Generation Source (service) › Generator
Issued 6 February 2007 Resolved
Generator armatures (port and starboard) were soiled with dirt and oil.
Due 28 February 2007
Resolved 7 February 2007
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 6 February 2007 Resolved
The starboard generator had an exhaust leak.
Due 28 February 2007
Resolved 7 February 2007
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 6 February 2007 Resolved
Piping for the lube oil system was not capped off at the service end.
Due 28 February 2007
Resolved 7 February 2007
Engineering › Compressed Air System (control) › Compressor
Issued 6 February 2007 Resolved
A wiring harness for the air compressor was not attached and left laying on the deck.
Due 28 February 2007
Resolved 9 August 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 6 February 2007 Resolved
The overboard discharge for the A/C unit had a cracked weld that was allowing sea water to penetrate the hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Construction/Loadline › Hull › Side Shell
Issued 6 February 2007 Resolved
An insert on the starboard side of the engine room had a three inch crack in the weld.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Construction/Loadline › Hull › Side Shell
Issued 6 February 2007 Resolved
A seven inch crack was found on the side shell at the port engine overboard exhaust area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Engineering › Steering Gear System › Rudder Stock
Issued 6 February 2007 Resolved
The starboard rudder stop assembly had major weld fractues.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Lifesaving › Lifefloat › Painter
Issued 6 February 2007 Resolved
The weak link/sea painter line was not properly attached around the body of the life float. The water lights were also not properly attached.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Lifesaving › Lifebuoys › Serviceable
Issued 6 February 2007 Resolved
The retro reflective tape on the starboard lifebuoy was not serviceable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 6 February 2007 Resolved
All overhead lighting fixtures in the crew accommodation area did not have covers for the light bulbs.
Due 28 February 2007
Resolved 9 August 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2007 Resolved
Wiring for the sewage pump was not properly spliced and left exposed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Fire Fighting › Means of Escape › Doorways
Issued 6 February 2007 Resolved
The dogs on the forward emergency escape door needed to be adjusted. (could not open by hand)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 February 2007 Resolved
The bilge alarm panel was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 February 2007 Resolved
A properly stocked first aid kit was not onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 6 February 2007 Resolved
The safety harness for the rescue platform was not onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2007
Engineering › Reduction Gearing/Clutches › Bolt
Issued 29 September 2006 Resolved
Prior to vessel carrying any passengers vessel must be made available for Coast Guard inspection. This inspection required due to recent collision with the M/V [name withheld] Vessel owner must demonstrate the cause of the collision has been corrected, and any damage to the vessel has been repaired. Contact USCG at [phone withheld] x 258 when vessel has been contacted and when it will be ready
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2006
Resolved 29 September 2006
Resolution: Replaced clutch bolt with proper length and installed double nut.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 April 2006 Resolved
Provide manufactures maintenance instructions for survival craft IAW 46 CFR 185.722
Due 12 May 2006
Resolved 17 July 2006
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 12 April 2006 Resolved
Make pressure vessel's available for internal inspection. Item must be conducted at dry dock.
Due 17 December 2006
Resolved 8 December 2006
Resolution: Pressure vsls not ready for internal inspection. Conducted external inspection. Told new owner pressure vsls must be ready for internal inspection at next annual (2 months). Added new deficiency to reflect change.
Engineering › Steering Gear System › Bracket/Clamp
Issued 28 April 2005 Resolved
Repair port and starboard rudder carrier, support framing, and rudder stops prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2005
Resolution: Repairs made to the satisfaction of Coast Guard Marine Inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 28 April 2005 Resolved
provide updated charts. Prior to getting underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2005
Resolution: Corrected charts provided.
Lifesaving › Lifefloat › Serviceable
Issued 28 April 2005 Resolved
Replace or repair two lifefloats before sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2005
Resolution: Lifefloats replaced.
Lifesaving › Buoyant Apparatus
Issued 29 March 2004 Resolved
The port side buoyant apparatus was in need of repair/replacement. Repair or replace port side buoyant apparatus.
Condition: Unknown
Due 25 April 2004
Resolved 1 April 2004
Resolution: Owner procured new lifefloat.
Lifesaving › Buoyant Apparatus
Issued 25 March 2004 Resolved
Weak link for the liferafts were not readible. Provide weak links for the liferafts onboard the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2004
Resolution: Weak links for the buoyant apparatus''''s were installed.
Lifesaving › Buoyant Apparatus
Issued 25 March 2004 Resolved
The 6-man buoyant apparatus was not tethered to the vessel to prevent it from floating away in the event of sinking. Attach the 6-man buoyant apparatus to the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2004
Resolution: The 6-man buoyant apparatus was tethered to the 22-man buoyant apparatus.
Fire Fighting › Fire Pumps
Issued 25 March 2004 Resolved
Fire pump did not maintain adequate pressure while fire hose was being discharged. Prove proper operation of the fire pump. LEGACY COMPONENT DESC: Pressure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2004
Resolution: Proper operation of the fire pump was demonstrated.
Engineering › Bilge Water Management System
Issued 25 March 2004 Resolved
A hole was discovered in the bilge piping system. Repair hole in bilge piping system. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2004
Resolution: Hole in bilge piping was repaired.
Electrical › Lighting (emergency)
Issued 25 March 2004 Resolved
Emergency lighting in the engine room was not adequate. Prove proper operation of emergency lighting in the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2004
Resolution: Proper operation of the emergency lighting in the engine room was demonstrated.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 25 March 2004 Resolved
Remote shutdown for main engines not operating. Prove proper operation of remote shutdowns for engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2004
Resolution: Proper operation of the remote shutdown for the engines was demonstrated.
Navigation › Piloting/Steering
Issued 13 February 2003 Resolved
Charts and Pubs missing/expired. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 14 February 2003
Resolution: Vsl owner purchased all new pubs and charts. 2003 light list was not yet available, vsl has 2002 copy.
Fire Fighting › Fire Hoses
Issued 13 February 2003 Resolved
01 (stbd side) of 02 fire hoses in poor condition numerous cuts through the reinforcement layer. Replace in kind. LEGACY COMPONENT DESC: Length
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2003
Resolved 14 February 2003
Resolution: Vsl owner purchased new UL approved fire hose.
Engineering › Compressed Air System (start air)
Issued 13 February 2003 Resolved
Pressure relief valve on port side air tank frozen. Will not relieve at proper setting, will not close once it opens. Replace or repair. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 13 March 2003
Resolved 14 February 2003
Resolution: Vsl owner purchased new relief valve.
Lifesaving › Buoyant Apparatus
Issued 19 February 2002 Resolved
Properly install six man lifefloat with weak link installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2002
Resolution: Item corrected on the spot
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 February 2002 Resolved
Replaced chafed hydraulic steering hose.
Condition: Improper/Lack of Maintenance
Due 21 March 2002
Resolved 20 February 2002
Resolution: Item inspected and corrected.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 19 February 2002 Resolved
Provide waste management plan.
Due 21 March 2002
Resolved 19 February 2002
Resolution: Corrected on the spot.
Electrical › Lighting (emergency)
Issued 19 February 2002 Resolved
Prove proper operation of emergency lighting in engineroom.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 February 2002
Resolved 20 February 2002
Resolution: Inspected and corrected
Accommodation/Occupational Safety › Messroom
Issued 19 February 2002 Resolved
Prove proper operation of emergency escape hatch in fwd lower galley.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2002
Resolution: Inspected, tested and corrected.
Unknown
Issued 14 August 1998 Resolved
PROVIDE/INSTALL EMERGENCY RESCUE PLATFORM.
Condition: Unknown
Due 17 September 1998
Resolved 17 August 1998
Electrical
Issued 14 February 1995 Resolved
PROVE PROPER OPERATION OF PORT AND STARBOARD GENERATOR OVERSPEED TRIP DEVICES.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Documentation
Issued 14 February 1995 Resolved
PROVIDE ON BOARD FCC RADIO TELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Navigation
Issued 1 February 1994 Resolved
Provide spacer to properly align stbd running light.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Electrical
Issued 1 February 1994 Resolved
Repair and prove properation of port gen. overspeed trip.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Navigation
Issued 1 February 1994 Resolved
Provide cotter pins for connecting bar port and starboard rudder stock.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Construction/Loadline
Issued 1 February 1994 Resolved
Remove excess oil and water from eng room bilge.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Engineering
Issued 1 February 1994 Resolved
Clean port blower motor and vent.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Accommodation/Occupational Safety
Issued 1 February 1994 Resolved
Install valve in water line over board discharge.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Fire Fighting
Issued 1 February 1994 Resolved
Renew/replace fire pump so adeq. pressure is provided.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Documentation
Issued 14 April 1993 Resolved
SUBMIT STABILITY CALCULATIONS FOR TANK CONVERSION, SPECIFIC TO THIS VESSEL. THIS DEFICIENCY WAS ACTUALLY ISSUED 13JAN92, SEE CASE# MI92000727._x001C_
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Documentation
Issued 14 April 1993 Resolved
HAVE VESSEL READMEASURED. THIS DEFICIENCY WAS ACTUALLY ISSUED 13 JAN 93, SEE CASE # MI93000727.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 27 January 1993 Resolved
INSTALL OVERSPEED SHUTDOWN CONTROL ON PORT GENERATOR, AND TEST TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 27 January 1993
Resolved 27 January 1993
Documentation
Issued 13 January 1992 Resolved
SUBMIT DRAWINGS OF TANK INSTALLATION, ONE LINE PIPING DIAGRAM, ONE LINE ELECTRICAL DRAWING AND ASSOCIATED BILL OF MATERIALS.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Documentation
Issued 13 January 1992 Resolved
HAVE VESSEL READMEASURED. ALL ITEMS TO BE SUBMITTED TO MSO MORGAN CITY FORREVIEW.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Documentation
Issued 13 January 1992 Resolved
SUBMIT STABILITY CALCULATION FOR TANK CONVERSION.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992
Navigation
Issued 28 January 1991 Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD.
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Construction/Loadline
Issued 28 January 1991 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Engineering
Issued 28 January 1991 Resolved
MAKE STBD F/O SHUT-OFF REACH ROD OPERABLE.
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Electrical
Issued 28 January 1991 Resolved
PROVE OPERATION OF BOTH GENERATOR OVERSPEED TRIPS
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Construction/Loadline
Issued 28 January 1991 Resolved
REPLACE MISSING HANDLE FOR OVERHEAD ESCAPE HATCH IN ENGINE ROOM.
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Electrical
Issued 28 January 1991 Resolved
RENEW WASTED SCREEN FOR STBD EXHAUST FAN.
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Navigation
Issued 28 January 1991 Resolved
REPAIR INOPERATIVE RADAR.
Condition: Unknown
Due 28 January 1991
Resolved 28 January 1991
Construction/Loadline
Issued 1 June 1989 Resolved
MAKE REPAIRS TO DAMAGE TO STDB BOW, STDB AMIDSHIP, AND STERN SHELL TO THE SATISFACTION OF AN ATTENDING CG INSPECTOR.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Navigation
Issued 5 February 1987 Resolved
PROVIDE APPROVED BULBS FOR LIGHT FIXTURES, AND/OR PROVIDE NAVLIGHTS THAT MEET U.L. STANDARD 1104, RELOCATE SIDELIGHTS TO COMPLY WITH NAVIGATION RULES.
Condition: Unknown
Due 5 February 1987
Resolved 5 February 1987
Unknown
Issued 6 February 1986 Resolved
INSERT CRACK (MINIMUM 18"X18") IN SIDE SHELL STBD AMIDSHIPS IN WAY OF LOWERPASSENGER LOUNGE.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Unknown
Issued 6 February 1986 Resolved
REPLACE SECTION OF TWO CRUSHED UNDERDOCK LARGE STERN COMPARTMENT PORT COVER(MINIMUM 18"). REPAIRS TO BE COMPLETED PRIOR TO OPERATING VESSEL. VESSEL TO BE PRESENTED FOR INSPECTION OF REPAIRS BY 13FEB86.
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986

Casualty record · 2

22 September 2006Routine · role: Involved in a Marine Casualty · activity 2793462
16 April 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4013362
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DYLAN J (2006–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record