GOL INTRUDER is a 1998 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 1998, most recently in July 2026, along with 30 deficiencies and 1 casualty investigation in 2002.

Records from 1998 to 2026. Most recent: inspection, 14 July 2026.

Built
1998
Last inspected
14 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8964123 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDL2173
467990
Flag
UNITED STATES
367390720
Maury page id
psix-467990

Inspections, by type

…with no type recorded7
Years with a record 24 calendar years (1998–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)150.8 ft × 30.0 ft × 12.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)150.8 ft × 30.0 ft × 12.0 ft
ITC tonnagegross 346 / net 103
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 26 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
346 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
103 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL2173MMSI 367390720 · active · compulsorily equipped · granted 17 August 2019, expires 17 August 2029
WDE7232MMSI 367390720 · expired · compulsorily equipped · granted 14 January 2009, cancelled 16 March 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDB7808MMSI 366744030 · cancelled · compulsorily equipped · granted 15 May 2004, cancelled 22 December 2008
WCX9576MMSI 366744030 · cancelled · compulsorily equipped · granted 10 February 1998, cancelled 25 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

QUIXOTIC Passenger (Inspected) · MISLE 48618 · 3 May 1998 · activity 109854

Inspection history · 37

14 July 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8406862
18 November 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8265062
28 August 2025 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8219664
19 August 2024 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7984445
8 December 2023 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7836390
21 November 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7797685
1 August 2023 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7757920
14 December 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7608953
30 November 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7359576
20 August 2021 Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7291376
19 November 2020 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7098681
19 August 2019 COI Inspection · Drydock Exam · Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6792742
3 June 2014 Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4880245
11 June 2012 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4341088
5 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4104370
18 February 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3681990
29 January 2009 Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3402300
14 January 2008 Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3130405
22 February 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2875974
15 February 2007 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2875063
23 October 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806470
26 January 2006 COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2572267
14 January 2005 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2274860
6 February 2004 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2001828
14 January 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1730145
12 May 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1616258
1 February 2002 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1483395
3 May 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 768407
22 April 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 203713
22 April 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 222544
25 January 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410472
25 January 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401163
16 March 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400940
3 October 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 29791
3 May 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 109854
18 April 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 7973
21 January 1998 COI Inspection · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438701

Deficiency record · 30

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2024 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported. Exhaust piping for the No.4 MDE had cracks in the flex and was visibly leaking exhaust gas. Exhaust piping for the MDE No.1 had salt water leakage. Raw water piping on the port side was wasted away needs replaced.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2024
Resolution: Received photos of repairs, uploaded under this deficiency. Received written confirmation from vessel rep that engines were run and no evident exhaust leakage was found following repairs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 August 2024 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category I, 406 MHz EPIRB installed to automatically float free and activate. EPIRB was accidentally activated during inspection, needs replaced.
Action required: 10 - Deficiency Rectified
Resolved 28 August 2024
Resolution: Replaced EPIRB and registration prior to inspection team's departure from vessel inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 November 2023 Resolved
Repairs or alterations to the hull or machinery that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. A hairline fracture was discovered where the #2 and the #1 SSDG exhausts are welded to the hull. Make permanent repairs to the satisfaction of an attending CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2023
Resolution: Received photo evidence of the welds being fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2023 Resolved
Exhaust gas must not leak from the piping or any connections. The #1 MDE has an exhaust gas leak where the MDE colling water injects to the exhaust piping. Make permanent repairs to the satisfaction of attending CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2023
Resolution: Received photo evidence of the exhaust leaks being fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2023 Resolved
Except as otherwise provided all engines must be water cooled. The engine head, block and exhaust manifold must be water jacketed and cooled by water from a pump that operates whenever the engine is operating. The #3 MDE jacket water pump mechanical seal is failed. Make repairs to the satisfaction of attending CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2023
Resolution: J/W pump was properly replaced
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 21 November 2023 Resolved
Repairs or alterations to the hull or machinery that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. A crack located in the main deck over the #1 MDE. Make permanent repairs to satisfaction of attending CG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2023
Resolution: Received photo evidence that the weld was properly repaired.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 21 November 2023 Resolved
The master of a vessel making an oceans or coastwise voyage must prepare a voyage plan. No voyage plans are being prepared. Provide objective evidence that voyage plans are being completed and communicated to a person ashore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 8 December 2023
Resolution: Voyage Plans completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2023 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. No documentation of crew training could be provided during annual inspection. Provide objective evidence that crew training is being conducted and logged/documented.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 8 December 2023
Resolution: Provided satisfactory evidence of training program and logging.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 21 November 2023 Resolved
For flammable or combustible liquid being transported on board a vessel in a portable tank, at least one B-V semi-portable foam, dry chemical or equivalent fire extinguisher, or a fire hose fitted with an approved portable mechanical foam nozzle with pick-up tube and two 5 gallon cans of foam must be carried. The foam inductor provided onboard is not operational. Repair or replace and prove proper operation prior to carrying portable tanks containing hazardous materials but no later than 30 days which ever is sooner.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2023
Resolved 22 November 2023
Resolution: Eductor was replaced with a new eductor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2021 Resolved
Flexible nonmetallic hose must meet SAE J-1942. Bow thruster generator fuel line is cotton jacketed. Vessel must provide fuel line that meets SAE J-1942.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 3 December 2021
Resolution: Replaced cotton jacketed fuel line with correct fuel line hose.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 19 November 2020 Resolved
The owner or master shall instruct each crew member at, upon first being employed, and prior to getting underway for the first time on a particular vessel, and at least once every three months, as to the duties that the crew member is expected to perform in an emergency, included, but not limited to, the emergency instructions listed on the emergency instructions placard. During the inspection, it was discovered that both deckhands were unfamiliar with how to energize the vessels fire pump and activate the vessels fixed CO2 system. Vessel shall ensure adequate training is provided to all crewmembers on board and incorporate this aspect of training as part of vessels training procedures. 46 CFR 185.420(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 November 2020
Resolution: Vessel had third party fire service technician assist with conducting training on activating system at time of inspection and company/vessel personnel provided additional firefighting training to crew members.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2019 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Vessel's batter charger ammeter for the #1 generator was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 September 2019
Resolved 30 August 2019
Resolution: Vessel rep sent a photo of the newly installed ammeter.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 5 August 2011 Resolved
EPA VGP permit missing. Vessel not required to submit NOI to EPA. Vessel required to obtain EPA VGP permit and perform monthly/annual inspections.
Action required: 705 - Other - as specified
Due 19 August 2011
Resolved 8 August 2011
Resolution: Vessel rep submitted copy of EPA VGP. All Sat.
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 5 August 2011 Resolved
Vessel First Aid/CPR for 50% of crew missing. Vessel shall provide proof of training.
Action required: 705 - Other - as specified
Due 5 September 2011
Resolved 8 September 2011
Resolution: Copies of vsl crew First Aid/CPR received. All Sat.
Engineering › Bilge Water Management System › Eductor
Issued 5 August 2011 Resolved
Engine Room and Generator Room Bilges full of oil. Vessel shall remove by VacTruck and provide proof of completion with receipts.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 5 August 2011
Resolution: Vessel pumped out the bilges and provided receipt of cleaning and photos. All Sat.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 5 August 2011 Resolved
Dirty Oil Tank, STBD side Lazarette, sight glass missing. Vessel shall provide proof of completion with new sight glass installed.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 8 August 2011
Resolution: Dirty oil tank sight glass replaced. Vessel rep sent photos of completed repairs. All Sat.
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 5 August 2011 Resolved
Slop Tank, Stbd side lazarette, vent missing Flame screen. Vessel shall install flame screen and provide proof of completion.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 11 August 2011
Resolution: Vessel installed new flame screen on vent for Slop Tank, Stbd side lazarette.
Lifesaving › Lifebuoys › Approval
Issued 5 August 2011 Resolved
Lifering, stbd side, main deck, missing USCG approval sticker. Vessel shall replace and provide proof of completion.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 11 August 2011
Resolution: Vessel purchased new lifering with USCG approval sticker and installed onboard vessel. All Sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 February 2007 Resolved
The starboard navigation light was extinguished.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2007
Resolution: Replaced bulb
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 February 2004 Resolved
Several items in the vessel's first aid kit were past the expiration date. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 14 March 2004
Resolved 13 February 2004
Resolution: Renewed expired items in medical locker.
Electrical › Lighting (emergency)
Issued 6 February 2004 Resolved
There was no emergency lighting illuminating the service generator switchboard. Labels were unreadable. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 14 March 2004
Resolved 13 February 2004
Resolution: Emergency light provided.
Electrical › Lighting (emergency)
Issued 6 February 2004 Resolved
There was no emergency light capable of illuminating the remote CO2 station forward of the engine room. Labels and instructions were unreadable. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 14 March 2004
Resolved 13 February 2004
Resolution: Emergency light provided.
Engineering › Steering Gear System
Issued 9 January 2003 Resolved
Provide a visual means to indicate operation of the steering pumps to be located at the operating station. LEGACY COMPONENT DESC: Power Unit
Action required: 705 - Other - as specified
Due 9 February 2003
Resolved 10 February 2003
Navigation › Piloting/Steering
Issued 9 January 2003 Resolved
Provide a compass deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2003
Resolved 10 January 2003
Fire Fighting › Means of Escape
Issued 9 January 2003 Resolved
Stencil generator room escape hatch and restencil tool room escape hatch. LEGACY COMPONENT DESC: Escape Route Signs
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2003
Resolved 9 January 2003
Electrical › Electrical Distribution System (service)
Issued 9 January 2003 Resolved
Remove dead-end wires over port inboard engine. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 9 February 2003
Resolved 9 January 2003
Lifesaving › Lifebuoys
Issued 9 January 2003 Resolved
Renew retro-reflective tape on stbd main deck lifering. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 705 - Other - as specified
Due 9 February 2003
Resolved 9 January 2003
Engineering › Steering Gear System
Issued 9 January 2003 Resolved
Provide a limit switch to stop the steering gear before it reaches the rudder stops. LEGACY COMPONENT DESC: Interlock
Action required: 705 - Other - as specified
Due 9 March 2003
Resolved 14 February 2003
Resolution: AS PER PHONE CON WITH [name withheld] , E-MAIL FROM [name withheld] DATED 12 FEB 2003, AND GULF CRAFT INC. WAIVER LETTER DATED 12 FEB 2003, THE REQUIREMENT FOR LIMIT SWITCHES ON THIS PARTICULAR STEERING SYSTEM HAS BEEN WAIVED.
Navigation › Piloting/Steering
Issued 1 February 2002 Resolved
Never installed. LEGACY COMPONENT DESC: Rudder angle indicator
Condition: Unknown
Due 13 March 2002
Resolved 27 February 2002
Resolution: Install as per fax from [name withheld], port eng.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 1 February 2002 Resolved
Remote actuation station needs lighting.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2002
Resolution: Installed lighting.

Casualty record · 1

12 May 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1616258
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CHRISTINE MCCALL (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.