Records from 1998 to 2021. Most recent: inspection, 23 August 2021.
Inspection history · 14
23 August 2021
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7294301
5 August 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7278189
12 December 2013
Administration
Administrative · Commandant (CG-CVC) · Activity 4768218
6 February 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2579951
4 February 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2579854
16 November 2005
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2758128
27 October 2005
In-Service Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2523514
25 October 2005
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2524240
11 August 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2459560
9 August 2005
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2457238
11 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 724118
30 December 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 83316
30 December 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 126528
27 February 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 128792
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 August 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 November 2021
Resolved 24 August 2021
Resolution: Vsl placed in Laid-up status.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 October 2005
Resolved
Certificate of Documentation expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 November 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 October 2005
Resolved
All fire extinguishers expired.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 October 2005
Engineering › Generator (propulsion-electric) › Battery
Issued 27 October 2005
Resolved
Properly install generator batteries.
Action required: 705 - Other - as specified
Resolved 31 October 2005
Engineering › Bilge Water Management System › Pump
Issued 27 October 2005
Resolved
Port main diesel engine shaft box bilge pump is inoperable.
Action required: 705 - Other - as specified
Resolved 31 October 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 27 October 2005
Resolved
Starboard shaft seal leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 October 2005
Resolved
Life ring buoy not properly marked.
Action required: 705 - Other - as specified
Resolved 31 October 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 October 2005
Resolved
Water light not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 27 October 2005
Resolved
Pollution placard not installed.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 October 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 October 2005
Resolved
Properly install main engine batteries.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 October 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 October 2005
Resolved
Main diesel engine starting batteries does not function as per design. (main engine will not start without assistance).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2005
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 27 October 2005
Resolved
Engine room bilges excessive oil, water, and debris.
Action required: 705 - Other - as specified
Resolved 31 October 2005
Deck/Cargo › Mooring/Anchoring › Winch
Issued 27 October 2005
Resolved
Replace port mooring winch motor.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 October 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2005
Resolved
Remove all wire nuts from vessel electrical system.
Action required: 705 - Other - as specified
Resolved 31 October 2005
Stability › Watertight Integrity › General
Issued 27 October 2005
Resolved
Seal all through hole fittings to engine room.
Action required: 705 - Other - as specified
Resolved 31 October 2005
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 27 October 2005
Resolved
Properly install rudder angle indicator system.
Action required: 705 - Other - as specified
Resolved 31 October 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 October 2005
Resolved
Emergency fuel shutoff valve doesn't work.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2005
Fire Fighting › Ventilation Systems › Fans
Issued 27 October 2005
Resolved
Engine room supply fan guard missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 27 October 2005
Resolved
Main engine stops improperly installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 31 October 2005