Inspection history · 77
10 August 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3821102
20 April 2010
MARPOL Annex I Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3720707
15 April 2009
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3453152
12 February 2008
COI Inspection · MARPOL Annex II Examination · Deficiency Check · Examination of Repairs · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3146378
20 April 2007
Administrative Inspection · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2911531
13 March 2007
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2887360
20 March 2006
MTSA Verification · MARPOL Annex I Examination · Internal Structural Exam · Ballast Water Examination · Examination of Repairs · Annual Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2606092
6 February 2006
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2580347
1 February 2006
Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2577501
25 April 2005
Periodic Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2344328
1 December 2004
MTSA Verification · Plan Review (Other than "T") · Administrative Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2265151
25 June 2004
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2110679
1 June 2004
Damage Survey
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2084758
22 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972300
12 May 2003
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1791560
18 March 2003
Internal Structural Exam · MARPOL Annex II Examination · Hull Examination · COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1726995
8 March 2002
Deficiency Check · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1492254
7 March 2001
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370066
2 August 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437779
12 October 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1397255
17 August 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408135
17 April 1998
Hull Examination · Permit to Proceed
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460155
16 February 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 178781
1 December 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113640
10 November 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 19406
6 August 1997
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783011
1 August 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390574
28 August 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359274
25 April 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1080844
25 April 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082025
12 April 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367707
1 April 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1447524
13 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1190332
6 October 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459957
9 February 1995
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 759704
6 February 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841619
23 January 1995
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 198847
6 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 67322
6 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 84349
30 November 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367230
19 August 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403816
27 October 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 848159
15 September 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452972
30 August 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 673104
2 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 847754
22 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 12445
6 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1142143
8 September 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440638
7 November 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957936
20 March 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928377
8 March 1991
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1213172
18 January 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906083
26 December 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215206
4 October 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233398
23 October 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 916821
9 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350349
7 November 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203706
25 October 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1199092
14 March 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1337733
20 February 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1025402
8 February 1988
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033298
20 October 1987
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1016911
6 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023702
21 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319216
12 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007334
3 October 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016154
6 March 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995022
11 October 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986589
17 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286379
26 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983498
26 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291827
11 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284785
19 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967855
31 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966322
14 October 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1272267
25 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968626
22 October 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969845
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 August 2008
Resolved
Vessel has holes in bridge bulkhead near aft door. Repair as new.
Due 13 September 2008
Resolved 15 August 2008
Resolution: Vessel welded new plate in place.
Construction/Loadline › Structures › Superstructure
Issued 13 August 2008
Resolved
Bridge window frames were excessively corroded. Crop and renew around window frames and reinstall windows.
Due 13 September 2008
Resolved 15 August 2008
Resolution: Windows and window frames were installed correctly.
Stability › Watertight Integrity › General
Issued 13 August 2008
Resolved
Water tight hatch was not watertight.
Due 15 August 2008
Resolved 15 August 2008
Resolution: Watertigt hatch is now watertight.
Construction/Loadline › Structures › Deck Plating
Issued 13 August 2008
Resolved
Helo deck plating was corroded with several holes trough deck. Crop and renew new deck plating in place. Non skid deck covering shall be installed.
Due 15 August 2008
Resolved 15 August 2008
Resolution: Deck plating was renewed as needed. Non skid was painted on deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 August 2008
Resolved
Helo deck lights were inoperable.
Due 15 August 2008
Resolved 15 August 2008
Resolution: Helo deck lighting is operating correctly.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 13 August 2008
Resolved
Vessel does not have a standard disharge connection. New fitting shall be placed onboard.
Due 15 August 2008
Resolved 15 August 2008
Resolution: Connection was placed onboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 April 2007
Resolved
Repair OWS indicators on main unit. Valves are opening and closing appropriately at detection of 15 PPM however, water discharge indicator and oil discharge indicator on main unit not switching over.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 24 April 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 April 2007
Resolved
Place emergency light fixture to adequately/safely light emergency egress ladder located in generator room.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 1 May 2007
Resolution: New lights installed in ladder well and platform.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 20 April 2007
Resolved
Repair, replace or show proper operation of fire dampers located in boiler room, CO2 protected space.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 24 April 2007
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 20 April 2007
Resolved
perform gauging of wasted metal around base of crane boom rest on deck of vessel. If substandard, crop and renew as necessary.
Action required: 705 - Other - as specified
Due 24 April 2007
Resolved 24 April 2007
Engineering › Lubricating Oil Service System › Hose
Issued 20 April 2007
Resolved
repair worn hydraulic hose located in boiler room port side.
Action required: 705 - Other - as specified
Due 23 May 2007
Resolved 1 May 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 March 2006
Resolved
Ensure all deck lifelines are attached and secure as required by 46 CFR 92.25-5.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Construction/Loadline › Structures › Scuttle
Issued 20 March 2006
Resolved
Remove salt/sand buildup around #3 starboard aft fresh water tank deck opening as required by 46 CFR 42.15-40.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 20 March 2006
Resolved
Secure/weld the following fire extinguisher brackets: 5 on main deck and 1 in maintenance shop as required by 46 CFR 95.50-10.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 March 2006
Resolved
Provide fire plan in rec room as required by 46 CFR 97.36-1.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 March 2006
Resolved
Renew retro-reflective tape on the following life bouys: Port heli deck and starboard bow stairwell as required by 46 CFR 199.70.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 March 2006
Resolved
Renew aft anchor light and primary upper red mast light as required by 46 CFR 120.420.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 20 March 2006
Resolved
Remove paint and hazardous material from deck as required by MSM Vol II, Section B, Ch 1 N.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 March 2006
Resolved
Secure all loose piping and plating on deck as required by MSM Vol II, Section B, Ch 1 N.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Construction/Loadline › Hull › Weld
Issued 20 March 2006
Resolved
Weld 18" x 18" insert on outboard bulkhead of the CT wench room as required by NVIC 7-68.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 20 March 2006
Resolved
Provide hot water and install toilets in forward main head as required by 46 CFR 92.20-35.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 23 April 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 20 March 2006
Resolved
Replace light covers on aft overhead and center deck lights in pipe alley as required by 46 CFR 111.75-20.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Construction/Loadline › Hull › Weld
Issued 20 March 2006
Resolved
Weld 3 ft x 5 ft deck insert in #3 welding stall as required by NVIC 7-68.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 20 March 2006
Resolved
Replace light covers on #3 welding stall deck lights as required by 46 CFR 111.75-20.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 20 March 2006
Resolved
Replace light cover in stinger control room aft as required by 46 CFR 111.75-20.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 20 March 2006
Resolved
Remove large oil bucket under #1 tensioner machine as required by as required by MSM Vol II, Section B, Ch 1 N.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Operations/Management › Pollution › Control of Garbage
Issued 20 March 2006
Resolved
Provide garbage placard on messdeck and all garbage handling areas as required by 33 CFR 151.9.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Operations/Management › Pollution › Control of Garbage
Issued 20 March 2006
Resolved
Provide waste management plan as required by 33 CFR.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Electrical › Electric Generation Source (emergency) › Generator
Issued 20 March 2006
Resolved
Prove proper operation of the emergency generator start and fuel system along with all protective devices as required by 46 CFR 112.25 and 112.50.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 20 March 2006
Resolved
Test emergency batteries as required by 46 CFR 112.55.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2006
Resolved 8 May 2006
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 20 March 2006
Resolved
Prove adequate emergency power and lighting as required by 46 CFR 112.43.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 March 2006
Resolved
Attach connection box to the bulkhead over the air handling unit in engine room as required by 46 CFR 111.60
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 9 May 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 20 March 2006
Resolved
Repair or remove various dead end cables in generator room as required by 46 CFR 111.60-5.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 23 April 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 20 March 2006
Resolved
Provide adequate cable supports throughout engineering spaces as required by IEEE standard 45.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 23 April 2007
Construction/Loadline › Structures › End Bulkhead
Issued 20 March 2006
Resolved
Prove watertight aft bulkhead in engineering space as required by 46 CFR 171.095.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Fire Fighting › Fire Hoses › Connections
Issued 20 March 2006
Resolved
Repair and demonstrate proper operation of forward fire hose nozzle as required by 46 CFR 95.10-10
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Fire Fighting › Emergency Fire Pumps › Capacity
Issued 20 March 2006
Resolved
Prove original operating characteristics are adequate to deliver a pitot tube pressure of 50 psi at 2 nozzles as required by 46 CFR 95.10-5.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Engineering › Compressed Air System (control) › Valve
Issued 20 March 2006
Resolved
Prove operation of ships service air system relief valves for air receivers #1 and #2. 46 CFR 54.15-10
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Engineering › Compressed Air System (control) › Compressor
Issued 20 March 2006
Resolved
Provide cover for A/C compressor #3 controller. 46 CFR 111.30-05
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Electrical › Electric Generation Source (service) › Generator
Issued 20 March 2006
Resolved
Prove proper operation of all ships service generators and safety devices as required by 46 CFR 111.10-4.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 March 2006
Resolved
Provide circuit breaker ratings for breakers on the main switchboard as required by 46 CFR 111.30-15.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 20 March 2006
Resolved
Complete appropriate ventilation tests. 46 CFR 111.103
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Operations/Management › Pollution › Ballast Water Management
Issued 20 March 2006
Resolved
Provide a ballast water management program as required by 33 CFR 151.59.
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 23 April 2007
Personnel › Certificates/Documents/Licenses › MMD, Lifeboatman
Issued 20 March 2006
Resolved
Provide 7 certified lifeboatman and 1 able seaman with STCW documentation as required by STCW 95 reg I/4.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 9 May 2006
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 20 March 2006
Resolved
Provide 1 person with proof of CPR/first aid training as required by STCW 95.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 9 May 2006
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 20 March 2006
Resolved
Provide STCW documents for all 3 documented seaman as required by STCW 95 reg I/4.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 9 May 2006
Communications › Alarms/Indicators › General Alarm
Issued 20 March 2006
Resolved
Demonstrate proper operation of the general alarm system as required by 46 CFR 113.25-9.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 9 May 2006
Communications › Alarms/Indicators › General Alarm
Issued 20 March 2006
Resolved
Mount and prove operation of general alarm light in main generator room as required by 46 CFR 113.25-10
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 March 2006
Resolved
Mount and demonstrate the operation of the emergency lighting in the main generator room as required by 46 CFR 112.05-1
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2006
Resolved 8 May 2006
Personnel › Training › Fire Fighting Basic
Issued 20 March 2006
Resolved
Demonstrate crew competency for fire and abandon ship drills in the presence of the attending marine inspector as required by 46 CFR 199.180.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 9 May 2006
Electrical › Electric Generation Source (service) › Generator
Issued 20 March 2006
Resolved
Demonstrate proper operation of #1 ships service generator as required by 46 CFR 111.10-4.
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 9 May 2006
Engineering › Lubricating Oil Service System › Flange
Issued 20 March 2006
Resolved
Demonstrate proper operation of lubrication system associated with generators as required by 46 CFR 56.50-80.
Action required: 705 - Other - as specified
Due 5 June 2006
Resolved 8 May 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 April 2005
Resolved
Repair or replace walkway around crane due to deterioration.
Condition: Improper/Lack of Maintenance
Due 27 May 2005
Resolved 9 May 2005
Engineering › Lubricating Oil Service System › Piping
Issued 25 April 2005
Resolved
Repair oil leaking from fixed crane to deck.
Due 27 May 2005
Resolved 9 May 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 25 April 2005
Resolved
Repalace all flexable hoses to CO2 bottles on crane deck. All hoses have been kinked and bent on installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 25 April 2005
Resolved
Properly restrain all electrical cable with a cable tray or metal ties in accordance with sub chapter J.
Due 27 May 2005
Resolved 9 May 2005
Stability › Incline Test › General
Issued 25 April 2005
Resolved
Provide updated stability data providing for usage of the track crane currently being used forward on the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 25 April 2005
Resolved
Replace all broken covers on light fixtures in machinery spaces making them intrinsically safe.
Due 27 May 2005
Resolved 3 April 2006
Lifesaving › Hand Flares › Expired
Issued 25 April 2005
Resolved
Renew all flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2005
Engineering › Fuel Oil Service System › Piping
Issued 25 April 2005
Resolved
Remove all non metallic hoses in excess of 30" on all diesel engines and hard pipe the fuel oil system.
Due 27 May 2005
Resolved 3 April 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 April 2005
Resolved
Remove all unused exhaust piping from the jet pumps that are no longer in use.
Due 27 May 2005
Resolved 3 April 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 April 2005
Resolved
Replace all exhaust insulation from diesel engines throughout the vessel. all diesel engines have no insulation on exhaust side of turbos.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2005
Engineering › Fuel Oil Service System › Flange
Issued 25 April 2005
Resolved
Repair fuel oil leak on #2 ship service generator fuel oil cooler.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2005
Engineering › Compressed Air System (control)
Issued 7 January 2003
Resolved
install pressure relief valve on dive air reciever thatdoes not exceed mawp of vessel (200psi)and prove proper operation in the presense of a USCG marine inspector NLT 18APR03.
Due 18 April 2003
Resolved 8 May 2003
Resolution: Vessel was provided with new relief valve and tested in the presence of marine inspectors.
Deck/Cargo
Issued 8 March 2002
Resolved
Ensure proper containment placed under the diesel vent for the fuel tank under the crane pedistal.
Due 8 April 2002
Resolved 13 March 2002
Resolution: Installed containment.
Pollution Prevention/Response
Issued 8 March 2002
Resolved
Update oil transfer procedures as per 33 CFR 155.750.
Due 8 April 2002
Resolved 13 March 2002
Resolution: Procedures updated and posted.
Electrical › Electrical Distribution System (emergency)
Issued 8 March 2002
Resolved
Place rubber mat for the electrical panel in the emergency generator.
Condition: Improper/Lack of Maintenance
Due 8 April 2002
Resolved 13 March 2002
Resolution: Installed mat.
Electrical
Issued 8 March 2002
Resolved
Remove dead end electrical wire behind the fuel tank, under crane.
Due 8 April 2002
Resolved 13 March 2002
Resolution: Wires removed.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 March 2002
Resolved
Ensure proper operating instructions for the CO2 release for the Boiler, on the crane.
Due 8 April 2002
Resolved 13 March 2002
Resolution: Instructions mounted.
Engineering
Issued 8 March 2002
Resolved
Replace all plastic wire ties supports with metal for all fresh water piping located in the generator room area.
Due 8 April 2002
Resolved 13 March 2002
Resolution: wires supported with metal clips.
Engineering
Issued 8 March 2002
Resolved
Replace all flex hoses over 30 inches for non vital and vital fresh and salt water systems.
Due 8 April 2002
Resolved 13 March 2002
Resolution: Hose replaced with plastic (PVC) piping.
Electrical
Issued 7 March 2001
Resolved
Prove proper operation of emergency generator low oil pressure shut down.
Condition: Unknown
Due 7 April 2001
Resolved 16 April 2001
Electrical
Issued 7 March 2001
Resolved
Prove proper operation of emergency generator high jacket water temperatureshut down.
Condition: Unknown
Due 7 April 2001
Resolved 16 April 2001
Electrical
Issued 1 August 1997
Resolved
PROVE PROPER OPERATION OF #3 S/S GEN OVERSPEED AND REVERSE POWER RELAY.
Condition: Unknown
Due 1 September 1997
Resolved 7 August 1997
Electrical
Issued 1 August 1997
Resolved
PROVE PROPER OPERATION OF E-GEN OVERSPEED.
Condition: Unknown
Due 1 September 1997
Resolved 7 August 1997
Engineering
Issued 1 August 1997
Resolved
PROVE PROPER OPERATION OF BOILER SHUTDOWNS AND SAFETIES AND PRESENT FOR INSPECTION STUDS AND BOLTS FOR MOUNTINGS BY 01 OCT 97 OR BEFORE PLACING BOILER BACK IN SERVICE AS PER 46 CFR 61.05-15.
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997
Construction/Loadline
Issued 1 April 1996
Resolved
Repair as original and to the satisfaction of the attending marine inspector, the port side anchor cable tunnels, both fore and aft sections with particular attention to wasted material in bottom plate sections.
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Engineering
Issued 6 October 1995
Resolved
CONDUCT SAFETY VALVE TEST ON LOW PRESSURE BOILER (CHI-78-31) IN ACCORDANCE WITH 46 CFR 61.05-10. THIS BOILER IS NOT TO BE PLACED IN SERVICE PRIOR TO THIS TEST.
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Documentation
Issued 6 October 1995
Resolved
PROVIDE ON BOARD AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. IF COMPLIANCE IS NOT ACHIEVED AFTER 06JAN96, THE VESSEL'S COI SHALL BE CONSIDERED INVALID & THE OWNER SHALL MAIL THE COI TO OCMI OF MORGAN CITY.
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Engineering
Issued 30 November 1994
Resolved
CROP & RENEW FORWARD BULKHEAD OF NO.6 PORT FUEL TANK (FR.37) BETWEEN DOUBLEBOTTOM AND EXISTING HORIZONTAL SEAM AND TO EACH SIDE OF TANK, WHILE CERT-_x001C_ IFIED GAS-FREE, TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Fire Fighting
Issued 19 August 1994
Resolved
PROVIDE POSITIVE CLOSURE FOR CRANE SPACE TO COMPLY WITH 46CFR95.15-35. (CO2FIRE PROTECTION). BOILER IS NOT TO BE PLACED IN SERVICE UNTILL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Accommodation/Occupational Safety
Issued 19 August 1994
Resolved
REPAIR OR REPLACE OVERHEAD CEILING TILES AS NEEDED THROUGHOUT THE VESSEL.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Accommodation/Occupational Safety
Issued 19 August 1994
Resolved
REPLACE MATTRESSES AS NEEDED IN ALL BUNK ROOMS.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Engineering
Issued 19 August 1994
Resolved
CONDUCT UT TESTING OF #6 PORT FUEL TANK IN THE PRESENSE OF THE ATTENDING CGMARINE INSPECTOR.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Engineering
Issued 19 August 1994
Resolved
PROVE PROPER OPERATION OF #2 BOILER AUTOMATION SYSTEM.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Accommodation/Occupational Safety
Issued 19 August 1994
Resolved
REMOVE AND CLEAN ALL AIR CONDITIONING VENTS AND INTAKES.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Engineering
Issued 19 August 1994
Resolved
CONDUCT HYDRO OF #2 BOILER IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Construction/Loadline
Issued 15 September 1993
Resolved
PROVIDE, INSTALL AND PROVE PROPER OPERATION OF CONTENT METER FOR OILY WATERSEPERATOR IN THE BILGE SYSTEM.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Engineering
Issued 15 September 1993
Resolved
MAKE PERMANENT REPAIRS TO TWO TUBES ON BOTTOM OF REAR TUBE SHEET AT THE ENDOF THE FIRE TUBE AND PERFORM HYDROSTATIC TEST OF BOILER TO THE SATISFACTIONOF THE COGNIZANT OCMI.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Engineering
Issued 15 September 1993
Resolved
DEMONSTRATE PROPER OPERATION OF SAFETY VALVES AND OPERATIONG SAFETY DEVICESAND ALARMS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Fire Fighting
Issued 4 October 1990
Resolved
PROVIDE TEST OF FIXED CO2 SYSTEM FOR GENERATOR ROOM AND BOILER ROOM.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Lifesaving
Issued 25 October 1988
Resolved
PROVIDE LIFERAFT SERVICING REPORT FOR LIFERAFT LOT 247 25MMUSR02 DUE TO CRACKED CASE COVER.
Condition: Unknown
Due 25 October 1988
Resolved 25 October 1988
Construction/Loadline
Issued 20 February 1988
Resolved
MAKE NECESSARY REPAIRS TO LEAKS IN DECK OVER #1 BOILER IN CRANE ROOM. (HOLES IN OVERHEAD-RAIN LEAKING ON ELECTRICAL EQUIPMENT)
Condition: Unknown
Due 20 February 1988
Resolved 20 February 1988
Deck/Cargo
Issued 3 October 1986
Resolved
PROVIDE A WEIGHT LOAD CHART FOR THE MANITOWOC 4000W CRANE.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Electrical
Issued 3 October 1986
Resolved
REPLACE THE HIGH VOLTAGE GLOVES FOR MAIN SWITCH BOARD.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Documentation
Issued 3 October 1986
Resolved
PROVIDE ONBOARD A COPY OF FUEL OIL TRANSFER PROCEEDURES THAT CONTAINS THE INFORMATION CONTAINED IN 33 CFR 155.700.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Lifesaving
Issued 3 October 1986
Resolved
REVISE VESSEL'S STATION BILL TO ACCOMODATE DEBARKATION RAFT FOR ON-DUTY DIVERS OR PROVIDE AN ADDITIONAL RAFT SOLEY FOR DIVING PERSONNEL.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Lifesaving
Issued 3 October 1986
Resolved
PROVIDE A COAST GUARD APPROVED LINE THROWING GUN ON BOARD VESSEL.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Fire Fighting
Issued 3 October 1986
Resolved
ALL SELF CONTAINED BREATHING APPARATUS AIR BOTTLES WITH HYDRO DATE BEYOND FIVE YEARS SHALL BE HYDRO TESTED.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Deck/Cargo
Issued 3 October 1986
Resolved
REPLACE WASTED FLAME SCREEN ON FUEL OIL VENT LINE LOCATED STBD. SIDE, AFT.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Fire Fighting
Issued 3 October 1986
Resolved
INSTALL A NECESSARY ADDITIONAL NUMBER OF GENERAL ALARM BELLS ON THE FWD MAIN DECK AREA SO THE ALARM MAY BE EASILY HEARD THROUGHOUT THIS AREA.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Fire Fighting
Issued 3 October 1986
Resolved
PROVIDE A PAIR OF NON-CONDUCTIVE GLOVES FOR EACH FIRE FIGHTING OUTFIT.
Condition: Unknown
Due 3 October 1986
Resolved 3 October 1986
Engineering
Issued 26 April 1985
Resolved
NO.1 AUXILIARY FT BOILER NO. 75-65 NOT TO BE PLACED IN SERVICE UNTIL RE- TUBED MOUNTS OPENED HYDROED SAFTIES SET AND SAFETY DEVICES TESTED.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Unknown
Issued 26 April 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, CHEROKEE, DN520180 AND ARE TO BE COMPLIED WITH BY 26JUN85.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Construction/Loadline
Issued 26 April 1985
Resolved
IN ACCORDANCE WITH USCG AND ABS APPROVED MODIFICATIONS TO STERN TRANSOM MAKE ADDITIONAL WELDING PASSES TO CENTER COMPARTMENT INTERNALS NO WELDS ARETO BE MADE WITH WATER BACKING UP ANY WELDED MEMBER.
Condition: Unknown
Due 26 April 1985
Resolved 26 April 1985
Unknown
Issued 11 October 1984
Resolved
THE BELOW LISTED DEFICIENCIES PERTAIN TO THE M/V CHEROKEE, O.N. DN520180.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Engineering
Issued 11 October 1984
Resolved
OPEN MOUNTINGS ON #2 AUXILIARY BOILER FOR COAST GUARD INSPECITON.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Engineering
Issued 11 October 1984
Resolved
REPAIR #1 AUXILIARY BOILER AND PERFORM THE FOLLOWING: HYDRO TO .5 TIMES MAWP, OPEN MOUNTINGS, CONDUCT TEST OF AUTO BURNER CONTROL SYSTEM, OPEN BOILER FOR FIRE AND WATER SIDE INSPECITON. #1 BOILER IS NOT TO BE USED UNTIL ABOVE IS COMPLETED.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984