MAURY USCG vessel records
← All vessels

MARTIN ENDEAVOR

Built
1969
Last inspected
10 July 2015
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 10 July 2015
…with no type recorded41
…past their stated due date4
Operational controls None recorded without a removal date
Years with a record 31 calendar years (1984–2015)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB2347
Flag
UNITED STATES
Maury page id
psix-46424

Documentation record

Tonnage as PSIX records it3108 - Convention (Subpart B), Gross Ton
1990 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 103 inspections, each with its date, unit and type; 127 deficiencies with the resolution recorded against each, 4 without one; operational controls, none recorded without a removal date; 7 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 103

10 July 2015 Administrative Inspection · Load Line/Change of Employment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5183463
28 August 2013 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4699884
11 July 2013 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4651598
28 December 2012 Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4506942
13 December 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4502374
13 July 2012 DAPI Audit · Periodic Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4376263
18 February 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4251654
20 January 2012 MARPOL Annex IV Survey · MARPOL Annex VI Survey · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4229695
12 December 2011 Construction Oversight · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4206656
20 October 2011 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4172509
15 September 2011 Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4146898
13 September 2011 Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4145200
24 June 2011 Plan Review (Other than "T") · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4056280
26 July 2010 Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3806458
6 April 2009 MARPOL Annex I Examination · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3447250
6 June 2008 MARPOL Annex I Examination · Annual Inspection · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3229097
12 February 2007 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2870788
17 July 2006 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2710601
12 December 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2549961
16 September 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2494272
21 June 2005 Annual Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2391296
6 May 2004 Damage Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2060828
3 May 2004 Examination of Repairs
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2057907
1 May 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2062067
27 April 2004 Cargo Tank Internal · Internal Structural Exam · Hull Examination · COI Inspection · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2009102
9 July 2003 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1840645
22 May 2003 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1797385
27 July 2002 Deficiency Check
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1657520
25 July 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1652111
16 April 2002 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1605951
25 March 2002 Annual Inspection · Internal Structural Exam
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1494887
16 May 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1068360
18 April 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1061959
2 March 2001 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386985
27 August 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 150441
29 June 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 130876
11 June 2000 Examination of Repairs · Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1050893
10 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 170244
15 April 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 538828
30 March 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1047743
22 March 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1365648
14 February 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376044
24 June 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 438997
23 June 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 108746
1 March 1999 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 798321
10 February 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1127541
12 July 1998 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 454600
6 January 1998 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1439959
19 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 443085
2 July 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 522524
2 July 1997 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1113543
16 April 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1418123
6 March 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 443310
22 January 1997 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1099467
3 January 1997 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1374829
13 November 1996 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172106
7 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 464395
23 June 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 530559
25 March 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1083461
8 March 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 475703
25 January 1996 Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1392379
2 January 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1192388
3 October 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 509552
21 July 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1189649
20 June 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 882173
21 May 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 489769
24 April 1995 Damage Survey · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1371077
13 January 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 835480
21 December 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 524843
4 June 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367446
31 May 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367286
11 April 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 857538
28 March 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 691422
28 March 1994 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 856660
21 March 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 525732
2 March 1994 Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 854928
1 May 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 839688
24 March 1993 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 675068
17 March 1993 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 446939
25 January 1993 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1145163
16 September 1992 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 830412
18 April 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 19741
11 March 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1260799
7 February 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 163619
13 February 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 913260
14 January 1991 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1228059
2 April 1990 Re-Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 914065
23 February 1989 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1194080
23 March 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 509639
4 March 1988 Re-Inspection · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1336365
2 September 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 473764
19 March 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1015646
6 March 1987 COI Inspection · Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1009109
14 August 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 483951
24 June 1986 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1309112
9 January 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1305831
12 November 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 465338
12 November 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 496240
25 June 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 445304
25 June 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286695
21 June 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1292165
4 February 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 300495
22 September 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 975215

Deficiency record · 127

Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 August 2013 No resolution recorded
Vessel is permitted to transit to Stanolin Dock to await availability for cleaning and marine chemist certificate. No cargo operations are permitted and all transits must be cleared with USCG. Inform USCG on intentions for vessel outstanding drydock and ISE dates.
Action required: 705 - Other - as specified
Due 11 September 2013 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 11 July 2013 No resolution recorded
Due to loaded condition, inspectors were unable to completely inspect P/V valves. Drydock within the next month will provide opportunity to fully inspect P/V valves.
Action required: 705 - Other - as specified
Due 14 August 2013 — due date passed with no resolution recorded
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 11 July 2013 No resolution recorded
Prove proper operation of relief valves for air receivers located in machinery space during drydock.
Action required: 705 - Other - as specified
Due 14 August 2013 — due date passed with no resolution recorded
Deck/Cargo › Cargo Heating › General
Issued 13 July 2012 No resolution recorded
Prior to carrying Thermal Fluid Heating cargos, perform test of thermal fluid heaters in the presence of a USCG Inspector.
Due 13 July 2017 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 13 September 2011 Resolved
Vessel rep reported a 1" hole above the waterline on the starboard stern. Temporary repairs have been made using splash zone. Vessel is authorized transit to Gulf Copper for permanent repairs and are secured from conducting cargo operations until permanent repairs are made.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 15 September 2011
Resolution: Attending inspectors verifed repairs to starboard aft "notch" of barge. Initial verification and testing of repairs made to hull were confirmed/witnessed by [name withheld] (ABS) prior to Coast Guard Inspectors arrival.
Deck/Cargo › Cargo Heating › General
Issued 24 June 2011 Resolved
Vessel must verify relief valve test pressures and replace broken sight glasses on the port and stbd thermal fluid heaters.
Action required: 705 - Other - as specified
Due 24 July 2011
Resolved 4 August 2011
Resolution: Provided required information confirming new repair
Electrical › Electrical Distribution System (service) › Switch
Issued 24 June 2011 Resolved
Vessel must provide details that the fire pump, bilge pump, emergency shutdowns, and all other electrical equipment meets Class 1. Div. 1 requirements within 10ft of new cargo header openings.
Action required: 705 - Other - as specified
Resolved 4 August 2011
Resolution: Installed Class 1 Div 1 boxes within 10 feet of Cargo Header.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 24 June 2011 Resolved
Vessel is required to tag out new installation of cargo header until plans are approved by the Marine Safety Center.
Action required: 705 - Other - as specified
Resolved 4 August 2011
Resolution: Received plan approval from MSC.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 26 July 2010 Resolved
Transfer hoses must be hydrostatically tested annually as per 33 CFR 156.170.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2010
Resolution: Vessel marked all hoses not hydro tested as "OUT OF SERVICE" and will not be used for transfer.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 26 July 2010 Resolved
Pressure gages on installed discharge portion of cargo piping must be calibrated annually.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2010
Resolution: New pressure gages installed on discharge portion of cargo piping.
Documentation › Certificates/Documents › Stability Letter
Issued 26 July 2010 Resolved
Vessel must provide stability letter upon request of attending Coast Guard marine inspector as per 46 CFR 170.120.
Condition: Improper/Lack of Maintenance
Due 27 July 2010
Resolved 27 July 2010
Resolution: Vessel was able to provide stability letter upon request.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 26 July 2010 Resolved
Vessel must have fuel oil transfer procedures as per 33 CFR 155.750
Condition: Improper/Lack of Maintenance
Due 27 July 2010
Resolved 27 July 2010
Resolution: Vessel provided fuel oil transfer procedures.
Engineering › Pressure Vessel › Relief Valve
Issued 26 July 2010 Resolved
Relief valve for water heater must be set at 100 PSI as per 46 CFR 54.01-15
Due 28 August 2010
Resolved 30 July 2010
Resolution: Replaced relief valve on water heater with 100 PSI rated valve.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 26 July 2010 Resolved
Replace wasted bracket for fire extinguisher in way of stern light.
Condition: Improper/Lack of Maintenance
Due 27 August 2010
Resolved 30 July 2010
Resolution: Replaced wasted bracket.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 July 2010 Resolved
Service spent portable fire extinguisher in way of stern light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2010
Resolution: Serviced portable fire extinguishers and provided Coast Guard with service report.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Securing Means
Issued 26 July 2010 Resolved
B-5 semi-portable CO2 fire extinguisher must be properly mounted to deck in a central location on the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2010
Resolution: Permanently mounted B-5 fire extinguisher.
Fire Fighting › Fire Hoses › Condition
Issued 26 July 2010 Resolved
Forward fire hose worn.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2010
Resolution: Replaced warn fire hose.
Fire Fighting › Nozzles › Condition
Issued 26 July 2010 Resolved
Forward fire hose nozzle frozen.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2010
Resolution: Serviced fire hose nozzle. Nozzle in proper working condition.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 26 July 2010 Resolved
Expired lights on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2010
Resolution: Replaced expired lights on all lifejackets.
Lifesaving › Immersion Suits › General
Issued 26 July 2010 Resolved
Replace expired lights on immersion suits.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2010
Resolution: Replaced expired lights on immersion suits.
Lifesaving › Hand Flares › Expired
Issued 26 July 2010 Resolved
Expired hand flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2010
Resolution: Replaced expired hand flares with 12 new hand flares.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 July 2010 Resolved
Replace improper line on lighted lifebuoy in way of stern light as per 46 CFR 199.70 (a)
Due 27 July 2010
Resolved 27 July 2010
Resolution: Replaced improper life line with line that meets the requirements of 46 CFR 199.70(a).
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 July 2010 Resolved
Retro-reflective tape on lifebuoy in way of stern light is worn.
Due 27 July 2010
Resolved 27 July 2010
Resolution: Renewed retro tape on lifebuoy.
Construction/Loadline › Markings › Load Line Mark
Issued 26 July 2010 Resolved
Load line mark must be painted in a contrasting color to the hull.
Due 27 August 2010
Resolved 30 July 2010
Resolution: Verified repainted load line.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 26 July 2010 Resolved
Hand held gas detector inoperable
Due 27 August 2010
Resolved 30 July 2010
Resolution: Vessel rented a unit to have onboard while their unit is being serviced and repaired. Training is being conducted for crew on how to operate and maintain the unit.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 July 2010 Resolved
Prove operation of emergency lighting from accommodation to engine room
Due 26 July 2010
Resolved 27 July 2010
Resolution: Light is in working condition
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 26 July 2010 Resolved
Provide additional SCBA bottle
Due 27 August 2010
Resolved 30 July 2010
Resolution: Additional SCBA bottle provided.
Construction/Loadline › Structures › Manhole
Issued 26 July 2010 Resolved
Port light cover missing in galley
Due 27 August 2010
Resolved 30 July 2010
Resolution: Replaced port light cover.
Construction/Loadline › Structures › Manhole
Issued 26 July 2010 Resolved
Remove wire from scuttle bolt hole
Condition: Improper/Lack of Maintenance
Due 26 July 2010
Resolved 27 July 2010
Resolution: Hole filled with bolt
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 26 July 2010 Resolved
Clean grease traps above stove
Due 26 July 2010
Resolved 27 July 2010
Resolution: Complete
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 26 July 2010 Resolved
Secure galley stove
Due 26 July 2010
Resolved 27 July 2010
Resolution: Complete
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 26 July 2010 Resolved
Secure washer and dryer to deck.
Due 27 August 2010
Resolved 30 July 2010
Resolution: Secured washer and dryer.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 26 July 2010 Resolved
Cover missing on electrical out let
Condition: Improper/Lack of Maintenance
Due 26 July 2010
Resolved 27 July 2010
Resolution: Replaced cover
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 26 July 2010 Resolved
Remove multiple connections to junction boxes
Due 27 July 2010
Resolved 27 July 2010
Resolution: Removed items
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 July 2010 Resolved
Properly label corresponding breakers to locations on ship
Due 27 July 2010
Resolved 27 July 2010
Resolution: Properly labeled
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 26 July 2010 Resolved
Maintain accessibility to all portable firefighting equipment
Due 27 July 2010
Resolved 27 July 2010
Resolution: Cleared debris from around equipment
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 July 2010 Resolved
Service leaking batteries for service generators
Due 27 August 2010
Resolved 30 July 2010
Resolution: Replaced batteries that serve the service generators.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 July 2010 Resolved
Correct all gaps in electrical panel in engine room.
Due 27 July 2010
Resolved 27 July 2010
Resolution: Corrected all gaps in breaker panel.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 26 July 2010 Resolved
Locate ground in 115 panel
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2010
Resolved 30 July 2010
Resolution: Proved proper service of ground in 115 panel.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 26 July 2010 Resolved
Need to replace hydrostatic release. Hydrostatic release is improperly installed and due to expire at the end of the month.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2010
Resolved 30 July 2010
Resolution: Replaced improperly installed hydrostatic release for life raft with new. CG inspector verified proper installation of unit.
Deck/Cargo › Cargo Stowage › General
Issued 26 July 2010 Resolved
Remove five gallon Diesel containers from engine space
Due 27 July 2010
Resolved 27 July 2010
Resolution: Removed extra five gallon containers from engine room.
Engineering › Bilge Water Management System › Manifold
Issued 26 July 2010 Resolved
Label Bilge Manifold
Due 27 August 2010
Resolved 30 July 2010
Resolution: Labeled bilge manifold.
Communications › Alarms/Indicators › General Alarm
Issued 26 July 2010 Resolved
Label general alarm bell in engine room.
Due 27 August 2010
Resolved 30 July 2010
Resolution: General alarm bell in engine room labeled.
Electrical › Electric Generation Source (service) › Switch
Issued 26 July 2010 Resolved
Replace pump room fan control
Due 27 July 2010
Resolved 27 July 2010
Resolution: Replaced pump room fan control
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 26 July 2010 Resolved
All wiring must be located in junction box
Due 27 July 2010
Resolved 27 July 2010
Resolution: Made all connections appropriately.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 July 2010 Resolved
Secure deck plates in various locations.
Due 27 August 2010
Resolved 30 July 2010
Resolution: Deck plates in engine room properly secured.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 July 2010 Resolved
Repair holes in deck grading
Due 27 August 2010
Resolved 30 July 2010
Resolution: Holes in deck grading repaired to the satisfaction of attending CG inspector.
Deck/Cargo › Cargo Stowage › General
Issued 26 July 2010 Resolved
Remove five gallon buckets of flammable liquid from port side pump room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2010
Resolution: Verified buckets removed from pump room.
Engineering › Pressure Vessel › Coast Guard Symbol
Issued 26 July 2010 Resolved
The horizontal pressure vessel (PV) mounted in the overhead on the stbd side of engine room does not meet the requirements in 46 CFR 54.01-5. Could not locate a data plate or the required stampings and it does not have a pressure relief valve installed. It appears that this PV was purchased and put into service to expand air capacity but is not of an approved
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2010
Resolution: Removed unauthorized PV from vessel.
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 July 2006 Resolved
Vessel IOPP has expired (2 Mar 06). New IOPP will be issued next US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 August 2006
Resolved 31 July 2006
Resolution: Received approved IOPP and delivered to Martin Marine Operations Manager [name withheld].
Deck/Cargo › Cargo Stowage › General
Issued 21 June 2005 Resolved
Provide approval for installation of storage container on main deck, or remove from vessel. If used as a flammable storage locker provide Coast guard Approval for that use.
Due 21 August 2005
Resolved 23 August 2005
Resolution: Received fax copy of Coast guard approval letter and plans for on-deck container to be used for storage of oil containment boom and general storage. Container IS NOT approved for flammable storage.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 June 2005 Resolved
Provide personnel burn protection on deck at exhaust stacks port and starboard.
Due 21 July 2005
Resolved 27 June 2005
Resolution: Mounted protective guards exhaust stacks.
Construction/Loadline › Hull › Hull Plating
Issued 6 May 2004 Resolved
Bow rake received 8 inch puncture in lower knuckle at and just aft of 4th transverse web frame. Barge must proceed to nearest shipyard for repair and subsequent examination by marine inspector prior to loading cargo.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2004
Resolved 6 May 2004
Resolution: Repairs satisfactorily examined by marine inspector.
Pollution Prevention/Response › Prevention Equipment
Issued 22 May 2003 Resolved
Install mechanical metallic plugs in fixed containment for port and starboard cargo manifolds as per 33 CFR 155.310. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 8 July 2003
Electrical › Electrical Distribution System (service)
Issued 22 May 2003 Resolved
Properly secure electrical conduit wireway in vicinity of fire station No.1 as per 46 CFR 111.60-5. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 8 July 2003
Engineering › Bilge Water Management System
Issued 22 May 2003 Resolved
Repair/Renew and prove proper operation of forepeak bilge valve reach rod assembly. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 8 July 2003
Electrical › Electrical Distribution System (service)
Issued 22 May 2003 Resolved
Properly mark all electrical motors as per 46 CFR 111.25-5. LEGACY COMPONENT DESC: Switch
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 8 July 2003
Engineering › Sea-water System (primary cooling)
Issued 22 May 2003 Resolved
Mark valves in vicinity of the fire main pump as per 46 CFR 56.20-5.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 8 July 2003
Lifesaving › Lifebuoys
Issued 22 May 2003 Resolved
Renew forward lifebuoy with new lifebuoy as per 46 CFR 199.640.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 8 July 2003
Lifesaving › Lifejacket/PFD (General)
Issued 22 May 2003 Resolved
Renew retroreflective material on lifejackets as per 46 CFR 199.620. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 22 May 2003
Engineering › Compressed Air System (control)
Issued 22 May 2003 Resolved
Remove isolation valves or install pressure relief valves in air compressor piping to the air receiver as per 46 CFR 56.50-20(c). LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 8 July 2003
Electrical › Electric Generation Source (service)
Issued 26 March 2002 Resolved
Demonstrate proper operation of the port ship service diesel generator ( includes operaing on ships load, testing the overspeed and low lube shutdown device and high jacket water alarm). LEGACY COMPONENT DESC: Generator
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 April 2002
Resolved 15 April 2002
Resolution: Witnessed sat operational test, overspeed, and low lube oil shutdown.
Documentation › Manuals/Policy Documentation
Issued 26 March 2002 Resolved
Provide an Approved Test Procedure for the Port Thermal Fluid Heater and demonstrate the proper operation of the heater. Do not operate until the Approved Test Procedure is provide and tested in the present of the attending Coast Guard Marine Inspector
Action required: 705 - Other - as specified
Due 1 September 2002
Resolved 7 August 2002
Resolution: Verified Thermal Fluid Heater Test procedure.
Construction/Loadline
Issued 2 March 2001 Resolved
SEAL OPEN BULKHEAD PENETRATION IWO LADDER TO ENGINE ROOM.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Deck/Cargo
Issued 2 March 2001 Resolved
EITHER HYDROSTATICALLY TEST AIR RECEIVER TO 1.25 MAWP IN PRECENCE OF INSPECTOR OR REPLACE RECEIVER.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Construction/Loadline
Issued 2 March 2001 Resolved
REMOVE/CLEAN OIL FROM BILGES IN PUMPROOM AND AFT RAKE.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Fire Fighting
Issued 2 March 2001 Resolved
REMOVE PROPANE BBQ FROM BARGE.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Construction/Loadline
Issued 2 March 2001 Resolved
REPACK MAIN VALVES IN PUMPROOM (CARGO) TO PREVENT EXCESSIVE LEAKING.
Condition: Unknown
Due 16 June 2001
Resolved 28 March 2002
Resolution: VALVES REPACK
Construction/Loadline
Issued 2 March 2001 Resolved
REPAINT VESSEL'S NAME ON STARBOARD BOW. IT IS BADLY WORN AND BARELY READABLE.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Deck/Cargo
Issued 2 March 2001 Resolved
PROVIDE DOCUMENTATION FOR CARGO PUMP RELIEF VALVES, AFFIRMING SATISFACTORY RELIEF AT 150 PSI WITHIN PAST ONE YEAR.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Deck/Cargo
Issued 2 March 2001 Resolved
PROVE PROPER OPERATION OF OVERSPEED DEVICE FOR PORT GENERATOR.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Deck/Cargo
Issued 2 March 2001 Resolved
PROVIDE EVIDENCE THAT CARGO PIPING DISCHARGE GAUGE HAS BEEN CALIBRATED WITHIN PAST 1 YEAR TO BE WITHIN 10% OF ACTUAL PRESSURE OR REPLACE GAUGE.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Engineering
Issued 2 March 2001 Resolved
SEAL PLUG TO FUEL FILTER LINE ON PORT CARGO PUMP (IT LEAKS).
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Accommodation/Occupational Safety
Issued 2 March 2001 Resolved
REPLACE UNAUTHORIZED MSD (CURRENTLY APPROVED FOR UNINSPECTED VESSEL SERVICE) WITH ONE APPROVED FOR INSPECTED VESSEL SERVICE OR PROVIDE DOCUMENTATION THAT IT IS NOW APPROVED FOR INSPECTED VESSEL SERVICE.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Deck/Cargo
Issued 2 March 2001 Resolved
CALIBRATE PORT SIDE GENERATOR TACHOMETER.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Deck/Cargo
Issued 2 March 2001 Resolved
PROVE LOW LUBE SHUTDOWN WORKS PROPERLY ON STBD GENERATOR.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Electrical
Issued 2 March 2001 Resolved
REPAIR/REPLACE STARBOARD SIDE NAVIGATIONAL LIGHT ELECTRIC WIRE.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Engineering
Issued 2 March 2001 Resolved
REMOVE STEEL GATES IN DISCHARGE CONTAINTMENT & WELD PLATE OR PROVIDE ACCEPTANCE BY OCMI.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Documentation
Issued 2 March 2001 Resolved
PROVIDE & CARRY AN INTERNATIONAL TONNAGE CERTIFICATE OR PROVIDE REASONING WHY THE VESSEL IS NOT REQUIRED OR EXEMPTED FROM CARRYING ONE.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Documentation
Issued 2 March 2001 Resolved
PROVIDE CURRENT LOAD LINE CERTIFICATE WITH ANNUAL ENDORSEMENT.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 2 March 2001 Resolved
PROVIDE 1 ADDITIONAL IMMERSION SUIT. VESSEL LIMITED TO 2 PERSONS WHILE OPERATING NORTH OF 32 DEGREES N LATTITUDE.
Condition: Unknown
Due 16 April 2001
Resolved 14 March 2001
Lifesaving
Issued 2 March 2001 Resolved
PROVIDE CALIBRATION GAS & CHART FOR COMBUSTIBLE GAS INDICATOR.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Unknown
Issued 2 March 2001 Resolved
PROVIDE MISSING DOGS FOR DOOR ACCESSING THE PUMP ROOM.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Engineering
Issued 2 March 2001 Resolved
REPLACE ALL FLAME SCREENS ON ALL CARGO TANKS & ULLAGE OPENINGS.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Engineering
Issued 2 March 2001 Resolved
REPLACE ALL NON RAISING STEM VALVES OR PROVIDE VALVE INDICATORS OR OTHER MEANS ACCEPTABLE TO OCMI TO INDICATE OPEN/CLOSE POSITION OF VALVES.
Condition: Unknown
Due 1 March 2004
Resolved 8 July 2003
Lifesaving
Issued 2 March 2001 Resolved
PROVIDE TEST DATE OR EXPIRATION DATE OF HYDROSTATIC RELEASE FOR EPIRB OR REPLACE IT.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 2 March 2001 Resolved
POST LIFEJACKET & IMMERSION SUIT DONNING PROCEDURES.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 2 March 2001 Resolved
LABEL VESSEL NAME ON IMMERSION SUIT.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Deck/Cargo
Issued 2 March 2001 Resolved
FIX CARGO PUMP OIL LEAK IN AIR MANIFOLD.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Deck/Cargo
Issued 2 March 2001 Resolved
CONDUCT OPERATIONAL TEST OF PORT THERMAL FLUID HEATER (TFH) & INTERNAL INSPECTION OF P/S TFHs IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Accommodation/Occupational Safety
Issued 2 March 2001 Resolved
REPLACE MISSING AFT STARBOARD VENT WINGNUT/CLOSURE DEVICE.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Lifesaving
Issued 2 March 2001 Resolved
PROVIDE WEAK LINK FOR THE LIFERAFT.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Lifesaving
Issued 2 March 2001 Resolved
PROVIDE LIFEJACKETS' & IMMERSION SUITS' LIGHTS.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Electrical
Issued 2 March 2001 Resolved
PROVIDE WIRE GUARDS TO (2) ENGINE ROOM LIGHTS & (1) AT THE TOP OF THE LADDER OR PROVE THAT GUARDS ARE NOT REQUIRED.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Fire Fighting
Issued 2 March 2001 Resolved
REPLACE CRACKED EXHAUST INSULATION IN PUMP ROOM.
Condition: Unknown
Due 23 March 2001
Resolved 23 March 2001
Navigation
Issued 22 March 2000 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH REQUIREMENTS FOR EMERGENCY TOWING EQUIPMENT AND TRAINING AS DESCRIBED IN 33 CFR 155.230.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Lifesaving
Issued 14 February 2000 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH REQUIREMENTS FOR EMERGENCY TOWING EQUIPMENT AND TRAINING AS DESCRIBED IN 33 CFR 155.320.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Lifesaving
Issued 14 February 2000 Resolved
PROVIDE AN EMERGENCY OUTFIT PER 46 CFR 35.30-20.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Deck/Cargo
Issued 14 February 2000 Resolved
PROVIDE EVIDENCE OF CARGO SYSTEM RELIEF VALVE SETTING VALUE AND THAT TESTING WAS CONDUCTED WITHIN THE PAST 12 MONTHS.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Deck/Cargo
Issued 14 February 2000 Resolved
PROVIDE EVIDENCE THAT THE CARGO PIPING HAS BEEN TESTED WITHIN THE PAST 12 MONTHS TO EITHER 1.5X THE RELIEF VALVE SETTING OR 1.5X THE MAXIMUM PRESSUREOF THE PUMP, WHICHEVER IS LOWER.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Deck/Cargo
Issued 14 February 2000 Resolved
PROVIDE EVIDENCE THAT THE CARGO HOSE HAS BEEN TESTED WITHIN THE PAST 12 MONTHS TO THE LESSER OF EITHER 1.5X THE RELIEF VALVE PRESSURE OR 1.5X THE MAXIMUM PRESSURE OBTAINABLE BY THE PUMP.
Condition: Unknown
Due 14 February 2000
Resolved 14 February 2000
Deck/Cargo
Issued 3 January 1997 Resolved
PROVE PROPER OPERATION OF PORTSIDE THERMAL FLUID HEATER.
Condition: Unknown
Due 3 February 1997
Resolved 22 January 1997
Documentation
Issued 3 January 1997 Resolved
PROVIDE PROOF OF A VALID DRUG TESTING PROGRAM.
Condition: Unknown
Due 10 January 1997
Resolved 22 January 1997
Deck/Cargo
Issued 3 January 1997 Resolved
PROVE PROPER OPERATION OF ANNUNCIATOR PANEL ON STBD THERMAL FLUID HEATER.
Condition: Unknown
Due 3 February 1997
Resolved 22 January 1997
Deck/Cargo
Issued 25 January 1996 Resolved
CONDUCT PRESSURE TEST OF CARGO PIPING.
Condition: Unknown
Due 11 February 1996
Resolved 11 February 1996
Electrical
Issued 25 January 1996 Resolved
CONDUCT SATISFACTORY TEST OF VSL GENERATOR'S LOW LUBE OIL AND OVERSPEED TRIPS/ALARMS.
Condition: Unknown
Due 11 February 1996
Resolved 11 February 1996
Deck/Cargo
Issued 25 January 1996 Resolved
CONDUCT SATISFACTORY TEST OF CARGO PUMP SHUT-DOWN.
Condition: Unknown
Due 11 February 1996
Resolved 11 February 1996
Construction/Loadline
Issued 25 January 1996 Resolved
REPAIR CRACK IN DECKHOUSE BULKHEAD, FORWARD CORNER, STBD SIDE. COGNIZANT OCMI TO BE NOTIFIED PRIOR TO COMMENCING REPAIRS. ALL REPAIRS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 25 February 1996
Resolved 25 March 1996
Engineering
Issued 24 April 1995 Resolved
Provide starboard thermal fluid heater for an internal exam and operationaltest per approved test procedures prior to using for cargo operations.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Accommodation/Occupational Safety
Issued 2 March 1994 Resolved
Renew port light glass in galley.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Deck/Cargo
Issued 2 March 1994 Resolved
Hydro cargo manifold.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Engineering
Issued 2 March 1994 Resolved
Prove operation of safety devices on 2 thermal fluid heaters.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Deck/Cargo
Issued 2 March 1994 Resolved
Test cargo pump emergency shutdown.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Fire Fighting
Issued 2 March 1994 Resolved
Test fire pump and all fire hoses.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Engineering
Issued 2 March 1994 Resolved
Test overspeed trip-generator.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Electrical
Issued 25 January 1993 Resolved
Remove wire nuts and hard wire electrical connections in port thermal fluidheater.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Construction/Loadline
Issued 25 January 1993 Resolved
Install cover on bilge pump motor controller.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Fire Fighting
Issued 25 January 1993 Resolved
Provide proper fire nozzles(metallic w/shutoff)
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Engineering
Issued 25 January 1993 Resolved
Repair valves in line from pump discharge on starboard thermal fluid heator.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Engineering
Issued 25 January 1993 Resolved
AIR RECEIVER TO BE INTERNALLY INSPECTED OR HYDROSTATICALLY TESTED IN THE PRESENCE OF A COAST GUARD INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Deck/Cargo
Issued 6 March 1987 Resolved
PROVE PROPER OPERATION OF THE STARBOARD THERMAL FLUID HEATER, INCLUDED ALL TESTS LISTED IN THE CHECK LIST PROVIDED TO YOU BY HOPKINS TO SATISFY COAST GUARD REQUIREMENTS.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Engineering
Issued 21 June 1985 Resolved
MAKE PERMANENT REPAIRS TO THE STBD BOILER FUEL SUPPLY SYSTEM, AND DEMONSTR-ATE ENTIRE TEST PROCEDURE ON THE STBD BOILER.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985
Construction/Loadline
Issued 21 June 1985 Resolved
DEMONSTRATE BILGE SUCTION IN FORWARD RAKE.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985
Deck/Cargo
Issued 21 June 1985 Resolved
MAKE PERMANENT REPAIRS TO BOTH PORT AND STBD THERMAL FLUID HEATER ALARM HORNS.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985
Electrical
Issued 21 June 1985 Resolved
PROVIDE LIGHT BULBS FOR ALL SWITCHBOARD INDICATOR LIGHTS AND DEMONSTRATE GROUND DETECTION SYSTEM.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985
Engineering
Issued 21 June 1985 Resolved
DEMONSTRATE THE FOLLOWING TEST ON THE PORT BOILER AS PROVIDED IN VOLCANIC HEATER APPROVED TEST PROCEDURE: A.2, B.1, B.2, C.1.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985
Engineering
Issued 21 June 1985 Resolved
PROVIDE CG APPROVED FUEL HOSE FOR THE FALL SUPPLY LINE ON THE PORT BOILER.
Condition: Unknown
Due 21 June 1985
Resolved 21 June 1985

Ownership record