CHUTE EM UP is a 1997 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1997, most recently in January 2025, along with 59 deficiencies, 1 operational control and 3 casualty investigations between 2010 and 2016.

Records from 1997 to 2025. Most recent: inspection, 13 January 2025.

Built
1997
Last inspected
13 January 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK5180
464483
Flag
UNITED STATES
368026040, 368062440
Maury page id
psix-464483

Inspections, by type

…with no type recorded7
Years with a record 23 calendar years (1997–2025)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 11.0 ft × 4.5 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · LAKE HAVASU CITY, AZ, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionGasoline Engine
Hull shapeShip
Hull configurationMonohull
Hailing portSIESTA KEY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Net Ton
10 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK5180MMSI 368062440 · active · compulsorily equipped · granted 17 October 2018, expires 17 October 2028
WDJ9437MMSI 368026040 · active · compulsorily equipped · granted 7 March 2018, expires 7 March 2028
WDG7909MMSI 367572050 · expired · compulsorily equipped · granted 25 April 2013, cancelled 15 July 2023
WDE6565MMSI 367381860 · cancelled · compulsorily equipped · granted 23 October 2008, cancelled 24 April 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SERENITY Passenger (Inspected) · MISLE 600619 · 24 March 2016 · activity 5839698THRILLER 09 Passenger (Inspected) · MISLE 859684 · 24 March 2016 · activity 5839698SERENITY Passenger (Inspected) · MISLE 600619 · 5 September 2010 · activity 3844346

Inspection history · 43

13 January 2025 Hull Examination · Deficiency Check · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8062773
29 November 2023 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7825116
30 January 2023 Annual Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7620151
11 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7424469
10 February 2021 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7132980
29 January 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7129136
12 March 2020 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6927836
16 January 2020 COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6871507
8 February 2019 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6621470
29 January 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6593020
7 May 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6408040
9 March 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6368127
11 December 2017 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6322458
30 March 2017 Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6115348
26 January 2017 Hull Examination · Deficiency Check · Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6053875
24 March 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5839698
1 February 2016 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5807361
26 May 2012 Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4323207
26 May 2012 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4326765
1 February 2012 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4236174
20 January 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4230445
6 December 2010 Drydock Exam · Deficiency Check · Plan Review "T" Boat · Administrative Inspection · Damage Survey · Simplified Stability Test · Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3905495
5 September 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3843078
5 September 2010 Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 3843382
5 September 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3844346
4 September 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3921791
8 February 2010 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3656363
7 January 2009 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3396972
7 January 2008 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3125778
17 January 2007 Annual Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2857043
2 February 2006 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2577473
7 January 2005 Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2269302
16 July 2004 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2135066
18 February 2003 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1739408
4 March 2002 Annual Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1489464
16 March 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1059691
20 June 2000 Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 1515490
6 December 1999 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1415303
8 September 1999 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1118960
21 January 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1467153
5 December 1997 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1105622
5 December 1997 Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1441333
2 October 1997 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 784609

Deficiency record · 59

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 February 2025 Resolved
46 CFR 181.420(a)(4); 16c A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. MI observed red light in gauge for pre-engineered fixed gas fire extinguishing system at helm did not indicate when system was deployed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 3 March 2025
Resolution: Reviewed photo sent from vessel rep depicting red light illuminating as required. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2025 Resolved
46 CFR 176.810(b)1(ii); 16c Portable and semi-portable extinguishers must be inspected and maintained; monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. MI observed no logs for recording monthly inspections of portable extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 3 March 2025
Resolution: Received image of new log from vessel rep for use in recording monthly inspections of portable extinguishers. All SAT.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 February 2025 Resolved
46 CFR 185.212; 16c A marine employer shall comply with the requirements of § 4.06 in subchapter A of this chapter. MI observed no chemical testing devices available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 3 March 2025
Resolution: Received picture of new chemical testing devices with expiration date noted 2025-12-31. All SAT.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 February 2025 Resolved
46 CFR 16.401(b); 16c An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. MI observed no records of EAP training for supervisor or crew members.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 10 February 2025
Resolution: Received documents for verification. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2025 Resolved
46 CFR 182.720(e); 10c Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. MI observed two hose clamps unsecured on same side of fuel line. Operator secured fuel line to tank.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 February 2025
Resolved 5 February 2025
Resolution: MI witness fuel line secured with two hose clamps.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 January 2025 Resolved
CG001 - A vessel must undergo an inspection for certification as specified in 176.404 and They must submit a written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel was due for COI renewal inspection on 16th January, 2025 and has yet to receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued. 46CFR176.500(b) 701c
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2025
Resolved 5 February 2025
Resolution: Conducted COI Renewal inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 November 2023 Resolved
Any vessel of at least five net tons which engages in...coastwise trade...must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel rep was unable to produce a valid COD. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2023
Resolved 4 December 2023
Resolution: Received copy of valid COD.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 November 2023 Resolved
Vessel owners shall advise NOAA in writing upon change of vessel or EPIRB ownership, transfer of EPIRB to another vessel, or any other change in registration information. MI observed the EPIRB registration did not reflect correct contact information. 47 CFR 80.1061(f)
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2023
Resolved 8 December 2023
Resolution: Received copy of new EPIRB registration reflecting the current owner.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 November 2023 Resolved
A flammable vapor detection system must provide a visual and audible alarm at the operating station. Vessel rep was unable to satisfactorily demonstrate function of the flammable vapor detection system. 46 CFR 182.480(d)
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2023
Resolved 14 December 2023
Resolution: Received proof of satisfactory test.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 29 November 2023 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel rep was unable to satisfactorily test emergency steering. 46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2023
Resolved 12 December 2023
Resolution: Provided proof of satisfactory test of emergency steering.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 November 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years...If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel rep was unable to produce a valid FCC Safety Radiotelephony Certificate. Vessel route is limited to 1000 feet from shore. 47 CFR 80.903
Action required: 705 - Other - as specified
Due 29 November 2023
Resolved 13 December 2023
Resolution: Received photo of radiotelephony certificate dated 06DEC23.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 November 2023 Resolved
A ship station license may only be granted to: the owner or operator of the vessel. MI observed the station license for the vessel was not issued to the current owner/operator. 47 CFR 80.15(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 29 December 2023
Resolution: Received updated station license.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 29 November 2023 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. MI observed vessel's emergency instructions were not reflective of vessel's equipment/systems nor the crew's demonstrated procedures. 46 CFR 185.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 14 December 2023
Resolution: Received satisfactory emergency instructions.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 November 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables. MI observed vessel was missing all publications with the exception of the Light List. 46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 20 December 2023
Resolution: All required publications onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 November 2023 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. MI observed the automatic bilge pump for the engine compartment did not have a visual indicator. 46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 15 December 2023
Resolution: Vessel installed light at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 November 2023 Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. MI observed both the starboard fuel fill line and fuel transfer line (before the filter) were not double clamped. 46 CFR 182.720(e)(3)(v)(B)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 14 December 2023
Resolution: All lines double clamped.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 November 2023 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI observed an open hole cut in the forward, starboard side of the engine compartment to permit cable to pass through. Fill hole to meet fire resistance/watertight integrity requirements for the space. 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 12 December 2023
Resolution: Sealed penetration in the bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 November 2023 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. MI observed the child size life jacket stowage location was neither separated from the adult life jacket storage location, nor properly marked. 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 12 December 2023
Resolution: Lifejackets were stowed separately from the adult lifejackets.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 November 2023 Resolved
Procedures for checking the proper operation of a flammable vapor detection system must be posted at the primary operating station. Vessel did not have operating instructions for the flammable vapor detection system. 46 CFR 182.480(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 December 2023
Resolved 12 December 2023
Resolution: Vessel rep provided test procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2023 Resolved
An adult life jacket must be provided for each person carried on board. 01 life jacket was found with holes, and 01 lifejacket has deteriorated retro material. Passenger count reduced by 02. 46CFR180.71(a)
Action required: 705 - Other - as specified
Resolved 31 January 2023
Resolution: Vessel purchased 02 new lifejackets.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 11 April 2022 Resolved
Any vessel of at least five net tons...must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel did not have a valid Certificate of Documentation. 46 CFR 67.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 24 May 2022
Resolution: Vsl rep obtained COD valid through 10MAY2023.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 April 2022 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Deckhand was not enrolled in a drug consortium and had not been pre-employment tested. 46 CFR 16.210(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2022
Resolved 14 April 2022
Resolution: Deckhand received pre-employment drug test -negative. He was also enrolled in the APCA Drug Consortium under Venice Parasailing LLC.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 April 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float-free and activate. Hydrostatic release for Category 1 EPIRB is expired. Vessel is limited to 3 nautical miles. 46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 14 April 2022
Resolution: Operator obtained a new hydrostatic release for the vessel's EPIRB. Vessel is no longer limited to 3nm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2022 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retroreflective material on the ring life buoy was worn/degraded. 46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2022
Resolved 14 April 2022
Resolution: Operator replaced retroreflective tape on the ring life buoy.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 30 January 2017 Resolved
Provide one additional A-II extinguisher for accomodation space iaw 46 CFR181.500(c).
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 7 February 2017
Resolution: O/O purchased A-II extinguisher .
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 January 2017 Resolved
Renew expired battery within ring life bouy light iaw 46CFR180.70(d).
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 30 January 2017
Resolution: Corrected prior to departure, battery was replaced.
Construction/Loadline › Hull › Hull Plating
Issued 21 January 2011 Resolved
PRIOR TO PLACING VESSEL IN SERVICE MAKE REPAIRS TO HULL AND FLIGHT DECK AS REQUIRED BY SECTOR ST. PETERSBURG WORKLIST.
Action required: 705 - Other - as specified
Resolved 8 February 2011
Resolution: EXAMINED VESSEL STRUCTURAL REPAIRS - ALL SAT.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 7 January 2009 Resolved
Replace/Renew port and stbd flex fuel fill hoses.
Action required: 705 - Other - as specified
Due 7 February 2009
Resolved 8 January 2009
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 January 2009 Resolved
Provide properly grounded flex fuel fill hoses to both port and stbd fuel tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2009
Resolved 8 January 2009
Stability › Watertight Integrity › General
Issued 7 January 2009 Resolved
Make forward engine compartment bulkhead watertight.
Action required: 705 - Other - as specified
Due 7 February 2009
Resolved 3 February 2011
Resolution: Examined repairs to vessel - all sat.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 7 January 2009 Resolved
Provide time delay device as required for gasoline engines.
Action required: 705 - Other - as specified
Due 7 February 2009
Resolved 8 January 2009
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 January 2008 Resolved
Replace broken/ worn antenna on EPIRB prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2008
Resolved 8 January 2008
Resolution: Placed new antenna on EPIRB.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 January 2008 Resolved
Repair or replace 5 Type 1 PFDs. Passenger count reduced to 7 until repaired or replaced.
Action required: 705 - Other - as specified
Due 31 January 2008
Resolved 7 January 2008
Resolution: Replaced worn lifejackets with 5 new.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 7 January 2008 Resolved
Repair fire-boy bracket installation, bolts pulled through hull prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 January 2008
Resolved 8 January 2008
Resolution: Placed washers in bracket to secure and keep bolts from pulling through.
Communications › Audible Communications › Horn/Whistle
Issued 7 January 2008 Resolved
Replace/ provide horn.
Action required: 705 - Other - as specified
Due 14 January 2008
Resolved 7 January 2008
Resolution: New horn provided for vessel.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 7 January 2008 Resolved
Properly secure passenger seating. (Seat not mounted to deck in fwd section)
Action required: 705 - Other - as specified
Due 14 January 2008
Resolved 8 January 2008
Resolution: Secured seats to deck.
Stability › Freeing Ports › General
Issued 7 January 2008 Resolved
Open freeing ports.
Action required: 705 - Other - as specified
Due 14 January 2008
Resolved 9 January 2008
Resolution: Operator replaced freeing ports and opened.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 January 2007 Resolved
The owner of the vessel SKY SCREAMER failed to schedule the vessel's drydock exam by 07Jan07. The owner continued operated after 07Jan07.
Due 18 January 2007
Resolved 18 January 2007
Resolution: Drydock exam conducted and deficiency corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 January 2007 Resolved
Provide the vessel with a proper first aid kit.
Action required: 705 - Other - as specified
Due 22 February 2007
Resolved 22 February 2007
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 January 2007 Resolved
Provide the vessel with a life jacket donning placard.
Action required: 705 - Other - as specified
Due 22 February 2007
Resolved 22 February 2007
Engineering › Steering Gear System › Actuator
Issued 7 January 2005 Resolved
Replace outdrive tilt trim hoses.(4)
Condition: Improper/Lack of Maintenance
Due 7 February 2005
Resolved 11 January 2005
Construction/Loadline › Hull › Stringer
Issued 7 January 2005 Resolved
Repair step on hull, P & S sides, amidship.
Condition: Improper/Lack of Maintenance
Due 7 February 2005
Resolved 11 January 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 January 2005 Resolved
Up-date first aid kit.
Condition: Improper/Lack of Maintenance
Due 21 January 2005
Resolved 7 January 2005
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 7 January 2005 Resolved
Up-date emergency instruction.
Condition: Improper/Lack of Maintenance
Due 21 January 2005
Resolved 11 January 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 January 2005 Resolved
Up-date all nautical publications IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Due 21 January 2005
Resolved 11 January 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 7 January 2005 Resolved
Label portable fire extinguisher location.
Condition: Improper/Lack of Maintenance
Due 21 January 2005
Resolved 11 January 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 January 2005 Resolved
Label life jacket stowage area with size and amount.
Condition: Improper/Lack of Maintenance
Due 21 January 2005
Resolved 11 January 2005
Lifesaving › Buoyant Apparatus › Approval
Issued 7 January 2005 Resolved
Prior to the carriage of passengers, provide a ring life buoy IAW 46CFR180.70.
Condition: Improper/Lack of Maintenance
Due 7 January 2005
Resolved 7 January 2005
Fire Fighting › Fire Bucket › Availability
Issued 7 January 2005 Resolved
Prior to the carriage of passengers, provide three 2 1/2 gallon fire buskets and label IAW 46CFR181.610.
Condition: Improper/Lack of Maintenance
Due 7 January 2005
Resolved 7 January 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 18 February 2003 Resolved
Prior to the carriage of passengers, replace FFFE system. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 18 February 2003
Resolved 21 February 2003
Navigation › Piloting/Steering
Issued 18 February 2003 Resolved
Prior to night time operation, repair compass light. LEGACY COMPONENT DESC: Compass Light
Condition: Placed in Improper Service
Due 18 February 2003
Resolved 21 February 2003
Operations/Management › Passenger Operations › Safety Orientation
Issued 18 February 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 18 March 2003
Resolved 7 January 2005
Construction/Loadline
Issued 6 December 1999 Resolved
RE-OPEN FREEING PORTS.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Fire Fighting
Issued 6 December 1999 Resolved
REPAIR MALFUNCTIONING FLAMMABLE VAPOR DETECTOR. IMPLEMENT START-UP PROCEDURE TO ENSURE ADEQUATE BLOWER OPERATION PRIOR TO ENGINE START-UP.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Construction/Loadline
Issued 6 December 1999 Resolved
PROVIDE EITHER: ADEQUATE SUB-DIVISION; OR, LIFE FLOAT(S) FOR 50% OF PERSONNEL CAPACITY OR AN EPIRB. UNTIL SUCH TIME THAT THIS REQUIREMENT HAS BEEN COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR THE VESSEL SHALL BE LIMITED TO LAKES, BAYS, AND SOUNDS SERVICE ONLY.
Condition: Unknown
Due 27 February 2000
Resolved 10 March 2000
Documentation
Issued 6 December 1999 Resolved
PROVIDE VSL DOCUMENT.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Construction/Loadline
Issued 6 December 1999 Resolved
PROVIDE INSPECTION ACCESS, PORT AND STBD, PROVIDING VISUAL ACCESS TO FWD PORTION OF HULL INTERIOR.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Engineering
Issued 5 December 1997 Resolved
INSTALL ELECTRICAL BONDING FOR FUEL FILLS.
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998
Documentation
Issued 5 December 1997 Resolved
PROVIDE FCC RADIO TELEPHONY SAFETY CERTIFICATE
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998

Casualty record · 3

5 September 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · 5 injured · activity 3844346
26 May 2012Routine · role: Involved in a Marine Casualty · activity 4326765
24 March 2016Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 5839698
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SKY SCREAMER (2010–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record