Records from 1997 to 2025. Most recent: inspection, 24 July 2025.
Inspection history · 48
24 July 2025
COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8193433
7 May 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8155369
2 October 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8031241
9 November 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7832135
19 July 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7759827
12 September 2022
Simplified Stability Test
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7557439
1 June 2022
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7464886
5 August 2021
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7264209
19 July 2021
Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7260792
14 August 2020
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7034764
18 December 2019
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6875546
11 July 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6745530
26 November 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6586380
13 December 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6323613
3 August 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6234007
13 December 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6056225
2 September 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5990540
12 November 2015
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5765839
30 September 2015
COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5727913
26 August 2015
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5226071
2 December 2011
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4200158
17 August 2011
Hull Examination · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4118202
11 August 2011
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4111297
25 July 2011
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4096812
23 July 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4093466
19 October 2010
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3872633
27 August 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3310578
5 December 2007
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3109859
16 October 2007
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3080175
4 October 2007
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3065810
13 March 2007
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2887147
4 October 2005
COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2507341
19 September 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2496229
19 September 2005
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2496264
7 September 2005
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2486315
10 January 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2272878
23 November 2004
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2246567
24 September 2003
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1911647
21 August 2003
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1886308
28 January 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1736232
15 October 2001
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1429635
10 August 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1366540
3 October 2000
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1408608
8 October 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450351
28 September 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384258
13 October 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 801712
23 October 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 787794
16 October 1997
Construction Oversight · MARPOL Annex V Examination · Initial Certification · Inclining Experiment · Hull Examination · Plan Review "T" Boat
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1421475
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 July 2025
Resolved
Engine room High water alarm did not function, all high water alarm floats were mounted too high and there was no visual alarm present at operating station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 August 2025
Resolved 22 August 2025
Resolution: Alarm repaired, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 July 2025
Resolved
Both PORT and STBD rudder posts were visibly leaking, with port being significantly worse than STBD. Port engine shaft seal was leaking seawater at a rate similar to port rudder post.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 August 2025
Resolved 19 August 2025
Resolution: Packing tightened, leaks stopped
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 July 2025
Resolved
STBD Engine was missing guard around accessory belt
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 August 2025
Resolved 22 August 2025
Resolution: Guard replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025
Resolved
Main power cable to starter was chafed through and roughly half of conductors rubbed through
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 August 2025
Resolved 22 August 2025
Resolution: Battery cable replaced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 July 2025
Resolved
No posted emergency instructions present onboard
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 21 August 2025
Resolved 19 August 2025
Resolution: Emergency instructions posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 July 2025
Resolved
Fuel shutoff valves were not properly labeled
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 19 August 2025
Resolution: Fuel shutoff valves labeled
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 July 2025
Resolved
1 main battery switch not securely mounted in place
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 19 August 2025
Resolution: Battery switch securely mounted
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 July 2025
Resolved
Fire pump gauge was observed inop.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 19 August 2025
Resolution: Replaced gauge on fire pump outlet
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 24 July 2025
Resolved
Ladder to machinery space was not securely fixed in place.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 19 August 2025
Resolution: Ladder securely mounted to bulkhead
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 24 July 2025
Resolved
Inspector observed significant amounts of water and debris including oil absorbent mats, cleaning products and insecticide containers in bilge spaces. Remove debris and water from bilge.
46 CFR 176.830(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 22 August 2025
Resolution: Bilge cleaned, all sat.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 July 2025
Resolved
Inspector observed two holes in the center portion of the forward machinery space bulkhead through which the adjoining space was clearly visible.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 19 August 2025
Resolution: Holes securely filled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2025
Resolved
Life line on ring life buoy was of the incorrect length (50ft) vs requirement (60ft)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 22 August 2025
Resolution: Line replaced, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 24 July 2025
Resolved
Inspector identified that both the port and stbd side bow rails had loose and missing hardware as well as cracked welds on stbd side.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 19 August 2025
Resolution: Port and STBD side bow rail repaired and hardware replaced
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 July 2025
Resolved
Inspector observed deterioration in wood board used as ventilation damper resulting in incomplete coverage of air ducts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 22 August 2025
Resolution: New ventillation panel installed, all sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 24 July 2025
Resolved
Hull structure condition is soft and water logged in vicinity of head and stbd deck. repair/replace to the satisfaction of CG Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2025
Resolved 22 August 2025
Resolution: Deck replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 August 2021
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shutdown all power ventillation systems and all engines that draw intake air from within the protected space. On board system failed to secured stbd engine after testing. Repair system IAW with regulations and test in presence of marine inspector. 46 CFR 181.420(a)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2021
Resolution: Company replaced missing cable. Tested system with sat results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 August 2021
Resolved
... All machinery must be installed and maintained in such manner as to afford adequate protection from causing machinery failure; STBD side main engine coolant hose was cracked and leaking. Replace with new. 46 CFR 182.100
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2021
Resolution: Crew replaced hose with new one. No further leaks were found.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 August 2021
Resolved
Penetrations and openings in watertight bulkheads must; have means to make them water tight. There are penetrations on engineroom bulkheads. Seal with approve material. 46 CFR 171.114(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2021
Resolution: All penetrations were sealed with approved material.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2021
Resolved
A visual and audible alarm must be provide at the operating station to indicate a high water alarm in a space with a non-watertight closure, such as a space with a non-water tight hatch on the main deck. Spaces 2 and 3 missing audible and visual alarm. 46 CFR 182.530(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 June 2022
Resolution: Tested audible/visual alarms on Annual Inspection. All sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 August 2021
Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharges openings for a space protected by a fixed gas extinguishing system. Engineroom ventilation closures aren't covering the duct and clips are broken. Realign vent closures and replace clip. 46 CFR 182.465(h)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2021
Resolution: Crew re-aligned covers and added magnet system to keeo them closed. Test sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 August 2020
Resolved
Replace 20 identified lifejackets in accordance with 46 CFR 160.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2020
Resolution: new approved lifejackets were purchased and replaced the older worn and torn lifejackets.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 18 December 2019
Resolved
Manual override for the Fireboy system in the engine compartment was not working properly. Switch for the override was replaced and the system retested. Manual override worked as intended after replacing the switch.
Action required: 10 - Deficiency Rectified
Resolved 18 December 2019
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 December 2019
Resolved
Safety Radiotelephony Cetificate is expired. Obtain new certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2020
Resolution: Obtained copy of radiotelephony certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2019
Resolved
Numerous identified lifejackets had worn retro-reflective tape. Company has spare rolls of solas approved tape and replaced all identified lifejackets before the conclusion of the inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 November 2018
Resolved
Engine Compartment High Water Visual/Audible Alarm Inoperable
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2018
Resolved 28 November 2018
Resolution: Alarm repaired and operable.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 26 November 2018
Resolved
Both Engines Require Machinery Guards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 December 2018
Resolved 28 November 2018
Resolution: Engine guards installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 December 2016
Resolved
Secure wires throughout vessel with metallic clamps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 20 January 2017
Resolution: Metalic clamps have been adequately installed throughout the engine room, properly securing electrical wires. Def rectified.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 December 2016
Resolved
label amount of life jackets in all the storage compartments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 20 January 2017
Resolution: Life jacket storage adequately labeled showing location of life jackets, type, and amount on each storage. Def rectified.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 December 2016
Resolved
Install guards on rotating machinery on port and starboard engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 20 January 2017
Resolution: metallic guard installed on rotating part of starboard side engine. def rectified.
Engineering › Bilge Water Management System › Pump
Issued 30 September 2015
Resolved
Prove proper operation of the #2 fwd compartment bilge pump.
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 8 October 2015
Fire Fighting › Fire Pumps › Pressure
Issued 30 September 2015
Resolved
Prove fire pump operation of 60 p.s.i.
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 7 December 2015
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 September 2015
Resolved
Provide guard for stbd engine PTO.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 14 October 2015
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 30 September 2015
Resolved
Plug hole in center console.
Action required: 705 - Other - as specified
Due 6 October 2015
Resolved 8 October 2015
Fire Fighting › Ventilation Systems › Ducts
Issued 26 August 2015
Resolved
Vent duct closure flaps (fire damper) to machinery space do not close properly due to rod bent during installation of bilge piping. Proof proper operation of fire damper.
Action required: 705 - Other - as specified
Resolved 26 August 2015
Resolution: Proved operation of fire damper.
Stability › Incline Test › General
Issued 11 August 2011
Resolved
Prior to 01DEC2011, comply with Final Rule Federal Register Vol. 75, No. 239, USCG-2007-0030, (dated December 14, 2010) IAW CG-543 Policy Letter 11-03 dated 08APR2011. (Passenger weight and inspected vessel stability requirements.)
Due 1 December 2011
Resolved 1 December 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2011
Resolved
Make stern light visible prior to operating at night or in limited visibility.
Due 11 August 2011
Resolved 11 August 2011
Resolution: Corrected on the spot.
Fire Fighting › Fire Pumps › Pressure
Issued 11 August 2011
Resolved
Prove proper operation of the pressure gauge for the fire pump IAW 46CFR181.300(b).
Due 11 August 2011
Resolved 11 August 2011
Resolution: New gauge was installed and corrected on the spot. Old gauge was not working, however, sufficient pressure was witnessed at the hose.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 11 August 2011
Resolved
Prove proper operation of the stbd MDE RPM gauge IAW 46 CFR 182.410(b).
Due 17 August 2011
Resolved 17 August 2011
Engineering › Reduction Gearing/Clutches › Shaft
Issued 28 July 2011
Resolved
Replace/install port shaft as original and make available for inspection prior to operation.
Action required: 705 - Other - as specified
Due 5 August 2011
Resolved 28 July 2011
Engineering › Reduction Gearing/Clutches › Shaft
Issued 28 July 2011
Resolved
Conduct shaft alignments on both shafts and provide results.
Action required: 705 - Other - as specified
Due 5 August 2011
Resolved 28 July 2011
Stability › Watertight Integrity › General
Issued 21 October 2010
Resolved
Make penetration to watertight bulkheads watertight IWO the electrical conduits in lazarette and forward compartment in both fore and aft part of space.
Due 4 November 2010
Resolved 5 November 2010
Resolution: Received photo attesting to repair.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 21 October 2010
Resolved
Prove vent dampers for engine space operate properly and close fully.
Due 4 November 2010
Resolved 5 November 2010
Resolution: Received photo attesting to repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 October 2010
Resolved
Remove or properly dead-end red wire under console.
Due 4 November 2010
Resolved 5 November 2010
Resolution: Received photo attesting to repair.
Stability › Watertight Integrity › General
Issued 21 October 2010
Resolved
Repair and prove proper operation of engine room hatch covers.
Due 4 November 2010
Resolved 5 November 2010
Resolution: Received photo attesting to repair.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 October 2010
Resolved
Install ventilation for battery compartments.
Due 4 November 2010
Resolved 5 November 2010
Resolution: Received photo attesting to repair.
Electrical › Electrical Distribution System (service) › Switch
Issued 21 October 2010
Resolved
Remount and label battery switches.
Due 4 November 2010
Resolved 5 November 2010
Resolution: Received photo attesting to repair.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 August 2008
Resolved
Provide service report for fixed pre-engineered fire suppression system in E/R and B-I at wheel.
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 4 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 August 2008
Resolved
Properly reattach bonding cable to STBD rudder.
Action required: 705 - Other - as specified
Due 29 August 2008
Resolved 29 August 2008
Accommodation/Occupational Safety › Potable Water System › General
Issued 27 August 2008
Resolved
Properly mount Jabsco pump tubing for fresh water in AFT lazerette
Action required: 705 - Other - as specified
Due 29 August 2008
Resolved 29 August 2008
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 27 August 2008
Resolved
Make adjustment to STBD and port shaft packing.
Action required: 705 - Other - as specified
Due 29 August 2008
Resolved 29 August 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 October 2007
Resolved
Provide rails IAW 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 1 November 2007
Engineering › Steering Gear System › Rudder
Issued 16 October 2007
Resolved
Provide rudder stops IAW 46 CFR 182.600.
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 1 November 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 October 2007
Resolved
Secure leak on port engine exhaust IWO bulkhead around fwd part of flex hose cuff.
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 1 November 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 March 2007
Resolved
Provide Annual Servicing report for all fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2007
Resolved 15 March 2007
Resolution: fax
Engineering › Bilge Water Management System › Interface Detector
Issued 14 March 2007
Resolved
Prove proper operation of high water alarm in lazerette and visual indicators in all spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2007
Resolved 15 March 2007
Resolution: fax
Stability › Severe Wind/Roll › General
Issued 14 March 2007
Resolved
Remove advertising sign and comply with vessel's stability letter, not to exceed 8.5' above load waterline.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2007
Resolved 15 March 2007
Resolution: fax
Engineering › Diesel Engine (propulsion-reduction gear) › Nozzle, Injection (fuel injection)
Issued 14 March 2007
Resolved
Correct/repair F/O leak on starboard MDE injection piping.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2007
Resolved 15 March 2007
Resolution: fax
Lifesaving › Visual Distress Signals (General) › Storage
Issued 14 March 2007
Resolved
Provide correct bracket for water marker light.
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 15 March 2007
Resolution: fax
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 29 September 2005
Resolved
Prove proper operation of starboard propulsion shaft seal.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Resolution: Received E-mail confirmation.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 September 2005
Resolved
Repair starboard Main Diesel Engine Sea water leak on exhaust manifold water jacket piping.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Resolution: Received E-mail confirmation.
Personnel › Training › Fire Fighting Basic
Issued 29 September 2005
Resolved
Provide Man overboard platform.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Resolution: Received E-mail confirmation.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 29 September 2005
Resolved
Meet the requirements of 46 CFR 177.900 at the Passenger Boarding Gate.
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 18 October 2005
Resolution: Received E-mail confirmation.
Construction/Loadline › Hull › Bracket
Issued 6 September 2005
Resolved
Repair vessel bow bumper, bumper has various cracked welds.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 19 September 2005
Resolution: Received E-mail confirmation form [name withheld].
Construction/Loadline › Hull › Bracket
Issued 6 September 2005
Resolved
Renew both forward hull steering skegs.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 19 September 2005
Resolution: Received E-mail confirmation from [name withheld].
Construction/Loadline › Hull › Hull Plating
Issued 6 September 2005
Resolved
Make repairs to hull FRP tabbing in way of port side propulsion shaft log.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 19 September 2005
Resolution: Received E-mail confirmation from [name withheld].
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 23 November 2004
Resolved
Fixed Pre-Engineered system does not shut down engine when activated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2004
Construction/Loadline › Structures › Scuttle
Issued 24 September 2003
Resolved
Renew the watertight hatch to forepeak. Existing hatch is cracked and leaking.
Condition: Improper/Lack of Maintenance
Due 24 September 2003
Resolved 26 September 2003
Fire Fighting › Fire Pumps › Impeller
Issued 24 September 2003
Resolved
Make repairs to bilge/fire pump and prove proper operation of same.
Condition: Improper/Lack of Maintenance
Due 24 September 2003
Resolved 26 September 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 28 January 2003
Resolved
Demonstrate operable fixed fire fighting engine S/D and provide current servicing report LEGACY COMPONENT DESC: Operating Controls
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2003
Resolved 3 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 28 January 2003
Resolved
Re-install machinery guard over stbd MDE attached fire pump belt.
Due 15 February 2003
Resolved 3 February 2003
Fire Fighting › Fire Pumps
Issued 28 January 2003
Resolved
Replace or repair fire pump gauge LEGACY COMPONENT DESC: Arrangement
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2003
Resolved 3 February 2003
Fire Fighting › Ventilation Systems
Issued 28 January 2003
Resolved
Ensure E/R ventilation closures are operable
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2003
Resolved 3 February 2003
Fire Fighting
Issued 8 October 1999
Resolved
Replace existing flex hose on discharge side of pump with hose & fittings rated at > 100 psi working pressure. Vessel not to operate until hose is replaced and inspected by CG.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Fire Fighting
Issued 16 October 1997
Resolved
Provide an approved fire hose and nozzle in accordance with 46 CFR 181.320.
Condition: Unknown
Due 16 November 1997
Resolved 26 March 1998