Records from 2002 to 2026. Most recent: inspection, 22 April 2026.
Inspection history · 31
22 April 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8354245
14 April 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8353044
11 June 2025
In-Service Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8157087
11 June 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8170640
17 April 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8113128
17 July 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7959366
21 March 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7883649
18 January 2023
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7620143
8 December 2022
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7606178
12 April 2022
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7429254
29 March 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7420817
14 March 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7411272
21 May 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7202728
15 June 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6977580
22 May 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6957941
29 January 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6898455
2 October 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6829943
14 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6683613
15 August 2017
Administrative Inspection · Simplified Stability Test · Spot Check · Initial Certification · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6241219
22 March 2006
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2608710
7 September 2005
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2486135
2 March 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2301910
11 January 2005
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2272858
10 January 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2272878
9 August 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2160532
9 August 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2174896
29 July 2004
In-Service Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2153710
21 July 2004
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2141160
29 July 2003
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1860219
27 September 2002
In-Service Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1680926
7 July 2002
COI Inspection · Construction Oversight · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1661836
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2025
Resolved
46 CFR 177.410-Fire detection and extinguishing systems must be installed. Replace pre-engineered fire system to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 25 June 2025
Resolved 20 June 2025
Resolution: Pre-engineered systems replaced and inspected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2025
Resolved
46 CFR 183.200-Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Replace alternator and all wiring harness burned during fire. Replace affected hoses and conduct engine full power trials to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 25 June 2025
Resolved 20 June 2025
Resolution: Identified items replaced along with satisfactory sea trial.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 April 2025
Resolved
46 CFR 181.420(3)(a) A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The engine did not shut down upon disconnection of the fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 April 2025
Resolved 17 April 2025
Resolution: Vessel crew provided evidence of engine shut and proper operation of the fire boy upon removal and replacement of the helm override controller.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 April 2025
Resolved
46 CFR 185.612(a) Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. The pre-engineered fire extinguishing system was not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 28 April 2025
Resolution: Vessel provided photo evidence of instruction labelling for the pre-engineered fire extinguishing system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2025
Resolved
46 CFR 185.608 Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. The fuel shutoff valve was not labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 30 April 2025
Resolution: Vessel provided photo evidence of proper labeling for the fuel shut off valve.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 17 April 2025
Resolved
33 CFR 151.57(a) The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. The garbage management plan was not found onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 30 April 2025
Resolution: Vessel provided picture evidence of their garbage management plan.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2025
Resolved
46 CFR 185.516(a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket donning placard was missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 April 2025
Resolved 17 April 2025
Resolution: Instructions for donning and use of life jacket placard was posted conspicuously.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 March 2022
Resolved
A vessel must undergo a drydock and internal structure examination at least once every two years. Last drydock and internal examination was conducted on 29JAN2020 and vessel is not permitted to operate until a drydock and internal structure inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2022
Resolution: Completed credit drydock
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 May 2021
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. MIs found auxiliary drive pulley loose and oscillating, and oil leak on main seal.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2021
Resolution: Operator repaired pulley.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2020
Resolved
46CFR180.70: At least one buoy must be fitted with a lifeline. Each lifeline on a buoy must be non kinking and have a breaking strength of 1,124 pounds and be of dark color. Life buoy needed to replace lifeline. Additionally, the fleets lifebuoys were missing retro reflective tape.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 15 June 2020
Resolution: Submitted pictures of fixed lifering
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 February 2018
Resolved
Battery not located as high as practical. Relocate battery so it is not directly touching hull adjacent to bilge, similar to primary battery bank for starting prior to carrying pax. 46CFR183.350.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2018
Resolved 28 February 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 February 2018
Resolved
Battery not in tray. Install battery with tray prior to carrying pax. 46 CFR 183.350.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2018
Resolved 28 February 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 February 2018
Resolved
Battery terminal connection not permanent type. Replace wing-nut connections with permanent types prior to carrying pax. 46 CFR 183.350
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2018
Resolved 28 February 2018
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 February 2018
Resolved
Operation of main propulsion both ahead and astern throttle sticking, unable to test. 46CFR176.804(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2018
Resolved 28 February 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 February 2018
Resolved
Install guards on main engine. 46CFR177.960
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2018
Resolved 28 February 2018
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 August 2017
Resolved
Fuel line penetrating bulkheads. Temp repairs in place. Vessel allowed to sail for 14 days while waiting for proper connection fittings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2018
Resolved 15 March 2018
Resolution: Verified onscene
Construction/Loadline › Structures › Transverse Bulkhead
Issued 6 September 2005
Resolved
Repair 1" hole at the bottom and centerline of the Collision Bulkhead.
Action required: 705 - Other - as specified
Due 5 October 2005
Resolved 13 September 2005
Resolution: Received e-mail confirmation that the requirement has been corrected.
Electrical › Electric Generation Source (service) › Generator
Issued 6 September 2005
Resolved
Install all missing bolts in the top cover of the generator.
Action required: 705 - Other - as specified
Due 5 October 2005
Resolved 13 September 2005
Resolution: Received e-mail confirmation that the requirement has been completed.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 6 September 2005
Resolved
Provide complete First Aid Kit IAW 46 CFR 160.041 Table.
Action required: 705 - Other - as specified
Due 5 October 2005
Resolved 13 September 2005
Resolution: Received e-mail confirmation that the requirement has been corrected.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 September 2005
Resolved
Prove proper operation of Ampere and Frequency Meters on Generator Switchboard.
Action required: 705 - Other - as specified
Due 5 October 2005
Resolved 3 May 2018
Resolution: Old def that was never closed out. No longer represents condition of vessel.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 6 September 2005
Resolved
Provide 08 Adult Lifejackets.
Action required: 705 - Other - as specified
Due 6 September 2005
Resolved 6 September 2005
Resolution: Corrected on the spot.
Engineering › Electric Propulsion System › Switch
Issued 9 August 2004
Resolved
Prove proper operation of drive system prior to the carriage of passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 July 2004
Resolved
Vsl failed Simpilified Sub-Division, provide a proposal to bring all the vessels in compliance. The proposal is due no later than 01 September 2004 for work to be completed on all vessels no later than 01 January 2005
Condition: Improper Installation
Due 30 August 2004
Resolved 2 March 2005
Engineering › Bilge Water Management System › Valve
Issued 21 July 2004
Resolved
Replace current bilge suction discharges with positive closures at the hull penetration.
Condition: Improper Installation
Due 21 September 2004
Resolved 21 July 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 July 2004
Resolved
Repair/renew handrails in way of bow deck. Current installation is loose, and the use of screws into GRP sandwich is questionable.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2004
Resolved 9 August 2004
Resolution: Cleared onboard, rhj.
Engineering › Bilge Water Management System › Pump
Issued 21 July 2004
Resolved
Prove operation of the fixed bilge system and high water alarms during the upcomming scheduled annual examination.
Due 21 August 2004
Resolved 9 August 2004
Resolution: Cleared onboard, rhj.
Electrical
Issued 27 September 2002
Resolved
Provide generator with 50 deg Centergrade ambient temp rating or derate to 80% or demonstrate ambient temp does not exceed 40 deg Centergrade
Action required: 705 - Other - as specified
Due 5 November 2002
Resolved 12 December 2002
Resolution: Generator manufacturer provide additional ambient temperature rating specification information. Generator does meet required ambient temperature rating. New information plate reflecting this rating has been attached to generator.