MAURY USCG vessel records Sign in
← All vessels

DELTA FLYER

DELTA FLYER is a 1970 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1980, most recently in May 2025, along with 67 deficiencies.

Records from 1980 to 2025. Most recent: inspection, 20 May 2025.

Built
1970
Last inspected
20 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF8511
Flag
UNITED STATES
367495640
Maury page id
psix-46541

Inspections, by type

…with no type recorded12
Years with a record 42 calendar years (1980–2025)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.4 ft × 16.1 ft × 7.8 ft
Registered tonnagegross 58 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1970
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF8511MMSI 367495640 · active · compulsorily equipped · granted 7 May 2021, expires 18 June 2031
WDA5530MMSI 366821070 · expired · compulsorily equipped · granted 27 July 2001, cancelled 1 October 2011
WCQ9582MMSI not assigned · expired · compulsorily equipped · granted 27 April 1995, cancelled 2 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PB-10 Freight Barge · MISLE 53468 · 17 March 2000 · activity 71866LINCOLN THOMAS Towing Vessel · MISLE 137324 · 17 March 2000 · activity 71866AT 304 Freight Barge · MISLE 186733 · 17 March 2000 · activity 71866CAPTAIN BLACK Towing Vessel · MISLE 193146 · 17 March 2000 · activity 71866

Inspection history · 67

20 May 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8139585
27 March 2025 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8100722
13 June 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7918584
8 June 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7709276
22 May 2023 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7694170
24 February 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7401022
11 May 2021 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7194619
20 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7178979
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108544
10 March 2020 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170644
6 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6677702
16 April 2019 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6663372
15 February 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6355424
6 February 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6083214
31 January 2017 Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6080267
24 March 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5838449
15 August 2015 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5217619
15 February 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4245019
19 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4211079
1 February 2011 Annual Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3937156
13 January 2011 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3926196
10 February 2010 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3678269
17 February 2009 Drydock Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3424525
18 April 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3187202
26 March 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3171529
21 February 2007 Hull Examination · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2875035
13 April 2005 Hull Examination · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2332830
18 November 2004 Simplified Stability Test
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2250759
3 March 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2005938
15 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1816158
11 March 2003 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1755811
27 February 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1492160
16 March 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379342
17 March 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 71866
28 January 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448064
19 January 2000 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1516816
27 August 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 168721
26 February 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413486
6 April 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 788623
6 March 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413323
20 March 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1098727
4 March 1997 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416449
13 February 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412925
23 February 1995 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449775
9 August 1994 Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426946
6 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235
6 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 225586
24 February 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359718
18 February 1993 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397866
21 April 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 947921
18 July 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249891
19 April 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916229
11 April 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215690
15 February 1990 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914341
16 February 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 892130
10 November 1988 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891359
5 April 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998030
30 June 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326509
17 February 1987 COI Inspection · Drydock Extension
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308042
21 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305971
24 September 1985 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996368
14 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979405
5 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281747
1 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280278
16 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275414
10 March 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965271
12 December 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277194

Deficiency record · 67

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 May 2025 Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates as set forth in 47 CFR part 80. Vessel master present for inspection did not have the correct radio operator permit.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 May 2025
Resolution: Vessel rep provided master with valid FCC license.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2025 Resolved
Where cable protection is carried through watertight bulkheads, the installation shall be such that will insure the water tight integrity of the structure. Bulkhead penetrations in the engine compartment were not sealed. 46 CFR 183.10-20(e) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2025
Resolution: Vessel sealed bulkhead cable penetrations with water-tight sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2025 Resolved
Each life jacket carried on a vessel on coastwise route must have a life jacket light approved in accordance with subchapter Q of this chapter. Life jackets on board did not have lights.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 May 2025
Resolution: Vessel installed lights on each life vest.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 May 2025 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Vessel is missing several courses of rail. 46 CFR 177.35-1 (OLD T)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2025
Resolution: Vessel installed rails/chains in missing locations.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 13 June 2024 Resolved
A fuel tank shall be fitted with a vent pipe which shall be connected to the tank at its highest point. MI observed vent pipe for the stern fuel tank was broken at the connection to the topside gooseneck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentation correcting deficiencies
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 13 June 2024 Resolved
The design of all exhaust systems must ensure minimum risk to personnel. MI observed SSDG exhaust muffler missing lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficienies.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 13 June 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides. Topside escape hatch needs to be labeled "EMERGENCY EXIT, KEEP CLEAR".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 June 2024 Resolved
Batteries shall be secured against shifting with motion of the boat. MI observed SSDG battery tray deteriorated against the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 June 2024 Resolved
Each floating electric waterlights shall meet the requirements of ANSI/UL 1196. Floating marker light batteries were expired and cases damaged on the port and starboard life floats lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 June 2024 Resolved
Man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have any recent drill documentation. Vessel's crew successfully completed MOB and Fire Drill.
Action required: 10 - Deficiency Rectified
Due 13 June 2024
Resolved 13 June 2024
Resolution: Vessel's crew completed drills in presence of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 February 2022 Resolved
Vessel shall be provided with suitable steering apparatus; starboard side rudder stop was cracked and did not effectively stop movement of the rudder. (Old T 46 CFR 183.30-1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2022
Resolution: Confirmed rectified deficiency.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 February 2022 Resolved
The discharge ends of vent pipes shall be fitted with removable 30x30 mesh flame screen; flame screens on both fuel vents had significant residue buildup, creating fire hazard. (Old T 46 CFR 182.20-35(d))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 February 2022 Resolved
Suitable guards shall be installed in way of all exposed and hazardous places; starboard MDE was missing cover over rotating machinery. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 February 2022 Resolved
Suitable covers shall be installed in way of all exposed and hazardous places; lagging for the exhaust on both MDEs was deteriorated and no longer preventing contact, needs replacement. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022 Resolved
Suitable covers shall be installed in way of all exposed and hazardous places; switchboard had uncovered penetrations, creating potentially hazardous condition. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022 Resolved
At each COI, electrical cable shall be examined; various cables in machinery space were unsupported for long stretches, and there was evidence of previous supports having broken off. (Old T 46 CFR 176.25-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022 Resolved
Additional control equipment and measuring instruments shall be provided as necessary to insure satisfactory operation of the generator; ground detection gauge was broken. (Old T 46 CFR 183.10-5(g))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 February 2011 Resolved
Provide up-to-date NOAA registration for EPIRB. Vessel is restricted to no more than 3NM from shore.
Due 23 February 2011
Resolved 16 February 2011
Resolution: Vessel rep provided up-to-date registration for EPIRB.
Stability › Watertight Integrity › General
Issued 1 February 2011 Resolved
Provide proper filling material for watertight bulkhead penetrations in fwd E/R.
Due 22 February 2011
Resolved 16 February 2011
Resolution: Provided proper filling material for fwd E/R bulkhead.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 1 February 2011 Resolved
Provide up-to-date CPR certificate for 50% of crew.
Due 22 February 2011
Resolved 25 March 2011
Resolution: Vessel captain provided documentation for the CPR certification.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 February 2009 Resolved
Replace nav lights with marine grade vertical filament bulbs
Action required: 705 - Other - as specified
Resolved 11 February 2010
Resolution: Correct Nav Lights in place.
Communications › Audible Communications › Bell
Issued 26 March 2008 Resolved
Provide a bel of 8" minimum size.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 March 2008 Resolved
Verify condition of hot water heater & repair/replace as necessary.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Stability › Watertight Integrity › General
Issued 26 March 2008 Resolved
Noted water ingress in aft port bilge (under pax compartment.) Determine where water ingress located & make permanent repairs as required.
Action required: 705 - Other - as specified
Resolved 24 March 2016
Resolution: Water ingress was determined to be from the shower, located above this space. Leak has been secured & verified.
Engineering › Steering Gear System › Ram
Issued 26 March 2008 Resolved
Replace rudder stops. During steering test, noted that steering ram slams into the rudder stops & rudder stops move from position.
Action required: 705 - Other - as specified
Resolved 31 March 2008
Construction/Loadline › Hull › Weld
Issued 26 March 2008 Resolved
Repair cracked welds on aft deck railing.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 March 2008 Resolved
Provide chafing gear for wiring in electrical panel & for stbd MDE fuel hoses.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 26 March 2008 Resolved
Remove loose/dead end wiring from transducer & below decks pax cabin.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Navigation › Piloting/Steering › Marine Charts
Issued 21 February 2007 Resolved
Provide updated navigation charts for area of operation.
Due 21 March 2007
Resolved 26 February 2007
Resolution: New Navigational charts were purchased.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2007 Resolved
Install proper wiring mounts in passenger void area.
Due 21 March 2007
Resolved 6 March 2007
Resolution: Wiring mounts installed in passenger void area.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 February 2007 Resolved
Provide cover for battery installation on the port side of engine room.
Due 21 March 2007
Resolved 6 March 2007
Resolution: Battery cover installed.
Documentation › Certificates/Documents › FCC SSL
Issued 21 February 2007 Resolved
Provide proper FCC paperwork.
Due 21 March 2007
Resolved 6 March 2007
Resolution: FCC paperwork provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 February 2007 Resolved
Provide Not Under Command Lights.
Due 21 March 2007
Resolved 6 March 2007
Resolution: Not Under Command Lights were provided.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 13 April 2005 Resolved
Condition: Unknown
Due 13 May 2005
Resolved 20 April 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 April 2005 Resolved
Condition: Improper Installation
Due 13 May 2005
Resolved 20 April 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 April 2005 Resolved
Clean STBD Battery box
Condition: Improper/Lack of Maintenance
Due 13 May 2005
Resolved 20 April 2005
Electrical › Electric Generation Source (service) › Generator
Issued 13 April 2005 Resolved
Clean Generator windings
Condition: Improper/Lack of Maintenance
Due 13 May 2005
Resolved 20 April 2005
Stability › Watertight Integrity › General
Issued 13 April 2005 Resolved
Seal STBD side engine room forward bulkhead penetration.
Condition: Improper/Lack of Maintenance
Due 13 May 2005
Resolved 20 April 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 February 2002 Resolved
Provide donning placard for life jackets. LEGACY COMPONENT DESC: Donnining Placard
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002 Resolved
Provide door and label circuit breakers on distribution panel in pilot house. LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Deck/Cargo › Mooring/Anchoring
Issued 27 February 2002 Resolved
Provide adequate anchor rope to satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: Anchor Rope
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Navigation › Piloting/Steering
Issued 27 February 2002 Resolved
Provide current Light List or updates. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002 Resolved
Remove all dead end wires from under the console in the pilot house. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002 Resolved
Replace cover on electrical outlet under console on the pilot house. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Lifesaving › Lifebuoys
Issued 27 February 2002 Resolved
Replace line on life ring and provide metal clip. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002 Resolved
Repack (2) stuffing tubes on starboard side of forward bulkhead in engine room. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002 Resolved
Install metal tie wraps on wire runs in engine room. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002 Resolved
Provide non-conductive deck covering and handrail on switchboard in engine room. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002 Resolved
Remove loose abandon wires in rudder room. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Engineering › Diesel Engine (auxiliary)
Issued 27 February 2002 Resolved
Repair fractures in exhaust piping in rudder room. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Construction/Loadline › Structures
Issued 27 February 2002 Resolved
Repair small holes in forward bulkhead of rudder room. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Construction/Loadline › Structures
Issued 27 February 2002 Resolved
Repair cracks were handrail meets the deck midship starboard side. LEGACY COMPONENT DESC: Handrail
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Engineering
Issued 6 March 1998 Resolved
PROPERLY INSULATE MAIN ENGINE EXHAUST.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Lifesaving
Issued 6 March 1998 Resolved
RENEW RING BUOY AND EQUIPMENT.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Electrical
Issued 6 March 1998 Resolved
MAKE PERMANENT REPAIRS TO PILOT HOUSE EMERGENCY LIGHTING.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Unknown
Issued 6 March 1998 Resolved
MAKE CONSOLE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Navigation
Issued 6 March 1998 Resolved
MAKE PERMANENT REPAIRS TO JOCKEY BAR ON STEERING SYSTEM/PROPER PIN TO TILLER ARMS.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Electrical
Issued 6 March 1998 Resolved
REPAIR AMP METER ON PORT BATTERY CHARGER.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Fire Fighting
Issued 6 March 1998 Resolved
PROVIDE NEW FIRE HOSE AND NOZZLE.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Documentation
Issued 6 March 1998 Resolved
PROVIDE CURRENT COAST PILOT, LIGHT LIST AND CURRENT CHARTS OF OPERATING AREA.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 4 March 1997 Resolved
INSTALL PROPER BILGE PIPING IN WAY OF LAZARET._x001C_
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Engineering
Issued 4 March 1997 Resolved
REPLACE FUEL VENT SCREENING WITH 30X30 WIRE MESH._x001C_
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Accommodation/Occupational Safety
Issued 23 February 1995 Resolved
REMOVE TINTED WINDOWS AND REPLACE WITH CLEAR GLASS IN PILOT HOUSE IAW CID MEMO #56.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Documentation
Issued 23 February 1995 Resolved
PROVIDE VALID SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Documentation
Issued 24 February 1994 Resolved
COMPLETE ITEMS 1,2,5,10,13,16,17,23,24,25,28,29,31,36, ON WORKLIST ISSUED BY HARD ON 24FEB94 PRIOR TO CARRYING PASSANGERS OR CARGO BUT NOT LATER THAN01MAR94
Condition: Unknown
Due 1 March 1994
Resolved 7 March 1994
Construction/Loadline
Issued 11 April 1991 Resolved
REPAIR FWD. STARBOARD PORTION OF BOW VOID AS ORIGINAL. 3" X 3" HOLE ON DECKTO BE REPAIRED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Engineering
Issued 11 April 1991 Resolved
INSTALL OVERSPEED DEVICES ON BOTH MAIN DIESEL ENGINES (46CFR176.25)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.