Records from 2016 to 2025. Most recent: inspection, 20 May 2025.
Documentation record
Registered dimensions (L × B × D)61.4 ft × 16.1 ft × 7.8 ft
Registered tonnagegross 58 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1970
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
20 May 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8139585
27 March 2025
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8100722
13 June 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7918584
8 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7709276
22 May 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7694170
24 February 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7401022
11 May 2021
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7194619
20 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7178979
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108544
10 March 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170644
6 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6677702
16 April 2019
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6663372
15 February 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6355424
6 February 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6083214
31 January 2017
Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6080267
24 March 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5838449
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 May 2025
Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates as set forth in 47 CFR part 80. Vessel master present for inspection did not have the correct radio operator permit.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 May 2025
Resolution: Vessel rep provided master with valid FCC license.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2025
Resolved
Where cable protection is carried through watertight bulkheads, the installation shall be such that will insure the water tight integrity of the structure. Bulkhead penetrations in the engine compartment were not sealed.
46 CFR 183.10-20(e) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2025
Resolution: Vessel sealed bulkhead cable penetrations with water-tight sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2025
Resolved
Each life jacket carried on a vessel on coastwise route must have a life jacket light approved in accordance with subchapter Q of this chapter. Life jackets on board did not have lights.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 May 2025
Resolution: Vessel installed lights on each life vest.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 May 2025
Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Vessel is missing several courses of rail.
46 CFR 177.35-1 (OLD T)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2025
Resolution: Vessel installed rails/chains in missing locations.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 13 June 2024
Resolved
A fuel tank shall be fitted with a vent pipe which shall be connected to the tank at its highest point. MI observed vent pipe for the stern fuel tank was broken at the connection to the topside gooseneck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentation correcting deficiencies
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 13 June 2024
Resolved
The design of all exhaust systems must ensure minimum risk to personnel. MI observed SSDG exhaust muffler missing lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficienies.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 13 June 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides. Topside escape hatch needs to be labeled "EMERGENCY EXIT, KEEP CLEAR".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 June 2024
Resolved
Batteries shall be secured against shifting with motion of the boat. MI observed SSDG battery tray deteriorated against the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 June 2024
Resolved
Each floating electric waterlights shall meet the requirements of ANSI/UL 1196. Floating marker light batteries were expired and cases damaged on the port and starboard life floats lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 June 2024
Resolved
Man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have any recent drill documentation. Vessel's crew successfully completed MOB and Fire Drill.
Action required: 10 - Deficiency Rectified
Due 13 June 2024
Resolved 13 June 2024
Resolution: Vessel's crew completed drills in presence of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 February 2022
Resolved
Vessel shall be provided with suitable steering apparatus; starboard side rudder stop was cracked and did not effectively stop movement of the rudder. (Old T 46 CFR 183.30-1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2022
Resolution: Confirmed rectified deficiency.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 February 2022
Resolved
The discharge ends of vent pipes shall be fitted with removable 30x30 mesh flame screen; flame screens on both fuel vents had significant residue buildup, creating fire hazard. (Old T 46 CFR 182.20-35(d))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 February 2022
Resolved
Suitable guards shall be installed in way of all exposed and hazardous places; starboard MDE was missing cover over rotating machinery. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 February 2022
Resolved
Suitable covers shall be installed in way of all exposed and hazardous places; lagging for the exhaust on both MDEs was deteriorated and no longer preventing contact, needs replacement. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Suitable covers shall be installed in way of all exposed and hazardous places; switchboard had uncovered penetrations, creating potentially hazardous condition. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
At each COI, electrical cable shall be examined; various cables in machinery space were unsupported for long stretches, and there was evidence of previous supports having broken off. (Old T 46 CFR 176.25-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Additional control equipment and measuring instruments shall be provided as necessary to insure satisfactory operation of the generator; ground detection gauge was broken. (Old T 46 CFR 183.10-5(g))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.