Records from 1980 to 2025. Most recent: inspection, 20 May 2025.
Inspection history · 67
20 May 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8139585
27 March 2025
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8100722
13 June 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7918584
8 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7709276
22 May 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7694170
24 February 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7401022
11 May 2021
Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7194619
20 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7178979
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108544
10 March 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7170644
6 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6677702
16 April 2019
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6663372
15 February 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6355424
6 February 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6083214
31 January 2017
Hull Examination · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6080267
24 March 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5838449
15 August 2015
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5217619
15 February 2012
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4245019
19 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4211079
1 February 2011
Annual Inspection · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3937156
13 January 2011
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3926196
10 February 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3678269
17 February 2009
Drydock Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3424525
18 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3187202
26 March 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3171529
21 February 2007
Hull Examination · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2875035
13 April 2005
Hull Examination · Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2332830
18 November 2004
Simplified Stability Test
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2250759
3 March 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2005938
15 May 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1816158
11 March 2003
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1755811
27 February 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1492160
16 March 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379342
17 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 71866
28 January 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448064
19 January 2000
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1516816
27 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 168721
26 February 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413486
6 April 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 788623
6 March 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413323
20 March 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1098727
4 March 1997
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416449
13 February 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412925
23 February 1995
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449775
9 August 1994
Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1426946
6 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235
6 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 225586
24 February 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359718
18 February 1993
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397866
21 April 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 947921
18 July 1991
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249891
19 April 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916229
11 April 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215690
15 February 1990
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914341
16 February 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 892130
10 November 1988
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891359
5 April 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998030
30 June 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326509
17 February 1987
COI Inspection · Drydock Extension
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308042
21 March 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305971
24 September 1985
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996368
14 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979405
5 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281747
1 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280278
16 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275414
10 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965271
12 December 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277194
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 May 2025
Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates as set forth in 47 CFR part 80. Vessel master present for inspection did not have the correct radio operator permit.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 May 2025
Resolution: Vessel rep provided master with valid FCC license.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2025
Resolved
Where cable protection is carried through watertight bulkheads, the installation shall be such that will insure the water tight integrity of the structure. Bulkhead penetrations in the engine compartment were not sealed.
46 CFR 183.10-20(e) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2025
Resolution: Vessel sealed bulkhead cable penetrations with water-tight sealant.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2025
Resolved
Each life jacket carried on a vessel on coastwise route must have a life jacket light approved in accordance with subchapter Q of this chapter. Life jackets on board did not have lights.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 20 May 2025
Resolution: Vessel installed lights on each life vest.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 May 2025
Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Vessel is missing several courses of rail.
46 CFR 177.35-1 (OLD T)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2025
Resolution: Vessel installed rails/chains in missing locations.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 13 June 2024
Resolved
A fuel tank shall be fitted with a vent pipe which shall be connected to the tank at its highest point. MI observed vent pipe for the stern fuel tank was broken at the connection to the topside gooseneck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentation correcting deficiencies
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 13 June 2024
Resolved
The design of all exhaust systems must ensure minimum risk to personnel. MI observed SSDG exhaust muffler missing lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficienies.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 13 June 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides. Topside escape hatch needs to be labeled "EMERGENCY EXIT, KEEP CLEAR".
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 June 2024
Resolved
Batteries shall be secured against shifting with motion of the boat. MI observed SSDG battery tray deteriorated against the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 June 2024
Resolved
Each floating electric waterlights shall meet the requirements of ANSI/UL 1196. Floating marker light batteries were expired and cases damaged on the port and starboard life floats lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 26 June 2024
Resolution: Rcvd photo documentaton correcting deficiencies.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 June 2024
Resolved
Man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel did not have any recent drill documentation. Vessel's crew successfully completed MOB and Fire Drill.
Action required: 10 - Deficiency Rectified
Due 13 June 2024
Resolved 13 June 2024
Resolution: Vessel's crew completed drills in presence of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 February 2022
Resolved
Vessel shall be provided with suitable steering apparatus; starboard side rudder stop was cracked and did not effectively stop movement of the rudder. (Old T 46 CFR 183.30-1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2022
Resolution: Confirmed rectified deficiency.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 February 2022
Resolved
The discharge ends of vent pipes shall be fitted with removable 30x30 mesh flame screen; flame screens on both fuel vents had significant residue buildup, creating fire hazard. (Old T 46 CFR 182.20-35(d))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 February 2022
Resolved
Suitable guards shall be installed in way of all exposed and hazardous places; starboard MDE was missing cover over rotating machinery. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 24 February 2022
Resolved
Suitable covers shall be installed in way of all exposed and hazardous places; lagging for the exhaust on both MDEs was deteriorated and no longer preventing contact, needs replacement. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Suitable covers shall be installed in way of all exposed and hazardous places; switchboard had uncovered penetrations, creating potentially hazardous condition. (Old T 46 CFR 177.35-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
At each COI, electrical cable shall be examined; various cables in machinery space were unsupported for long stretches, and there was evidence of previous supports having broken off. (Old T 46 CFR 176.25-15)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 February 2022
Resolved
Additional control equipment and measuring instruments shall be provided as necessary to insure satisfactory operation of the generator; ground detection gauge was broken. (Old T 46 CFR 183.10-5(g))
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2022
Resolved 28 February 2022
Resolution: Received photo evidence of rectified deficiency.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 1 February 2011
Resolved
Provide up-to-date NOAA registration for EPIRB. Vessel is restricted to no more than 3NM from shore.
Due 23 February 2011
Resolved 16 February 2011
Resolution: Vessel rep provided up-to-date registration for EPIRB.
Stability › Watertight Integrity › General
Issued 1 February 2011
Resolved
Provide proper filling material for watertight bulkhead penetrations in fwd E/R.
Due 22 February 2011
Resolved 16 February 2011
Resolution: Provided proper filling material for fwd E/R bulkhead.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 1 February 2011
Resolved
Provide up-to-date CPR certificate for 50% of crew.
Due 22 February 2011
Resolved 25 March 2011
Resolution: Vessel captain provided documentation for the CPR certification.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 February 2009
Resolved
Replace nav lights with marine grade vertical filament bulbs
Action required: 705 - Other - as specified
Resolved 11 February 2010
Resolution: Correct Nav Lights in place.
Communications › Audible Communications › Bell
Issued 26 March 2008
Resolved
Provide a bel of 8" minimum size.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 March 2008
Resolved
Verify condition of hot water heater & repair/replace as necessary.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Stability › Watertight Integrity › General
Issued 26 March 2008
Resolved
Noted water ingress in aft port bilge (under pax compartment.) Determine where water ingress located & make permanent repairs as required.
Action required: 705 - Other - as specified
Resolved 24 March 2016
Resolution: Water ingress was determined to be from the shower, located above this space. Leak has been secured & verified.
Engineering › Steering Gear System › Ram
Issued 26 March 2008
Resolved
Replace rudder stops. During steering test, noted that steering ram slams into the rudder stops & rudder stops move from position.
Action required: 705 - Other - as specified
Resolved 31 March 2008
Construction/Loadline › Hull › Weld
Issued 26 March 2008
Resolved
Repair cracked welds on aft deck railing.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 March 2008
Resolved
Provide chafing gear for wiring in electrical panel & for stbd MDE fuel hoses.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 26 March 2008
Resolved
Remove loose/dead end wiring from transducer & below decks pax cabin.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Navigation › Piloting/Steering › Marine Charts
Issued 21 February 2007
Resolved
Provide updated navigation charts for area of operation.
Due 21 March 2007
Resolved 26 February 2007
Resolution: New Navigational charts were purchased.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 February 2007
Resolved
Install proper wiring mounts in passenger void area.
Due 21 March 2007
Resolved 6 March 2007
Resolution: Wiring mounts installed in passenger void area.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 February 2007
Resolved
Provide cover for battery installation on the port side of engine room.
Due 21 March 2007
Resolved 6 March 2007
Resolution: Battery cover installed.
Documentation › Certificates/Documents › FCC SSL
Issued 21 February 2007
Resolved
Provide proper FCC paperwork.
Due 21 March 2007
Resolved 6 March 2007
Resolution: FCC paperwork provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 February 2007
Resolved
Provide Not Under Command Lights.
Due 21 March 2007
Resolved 6 March 2007
Resolution: Not Under Command Lights were provided.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 13 April 2005
Resolved
Condition: Unknown
Due 13 May 2005
Resolved 20 April 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 April 2005
Resolved
Condition: Improper Installation
Due 13 May 2005
Resolved 20 April 2005
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 April 2005
Resolved
Clean STBD Battery box
Condition: Improper/Lack of Maintenance
Due 13 May 2005
Resolved 20 April 2005
Electrical › Electric Generation Source (service) › Generator
Issued 13 April 2005
Resolved
Clean Generator windings
Condition: Improper/Lack of Maintenance
Due 13 May 2005
Resolved 20 April 2005
Stability › Watertight Integrity › General
Issued 13 April 2005
Resolved
Seal STBD side engine room forward bulkhead penetration.
Condition: Improper/Lack of Maintenance
Due 13 May 2005
Resolved 20 April 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 27 February 2002
Resolved
Provide donning placard for life jackets. LEGACY COMPONENT DESC: Donnining Placard
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002
Resolved
Provide door and label circuit breakers on distribution panel in pilot house. LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Deck/Cargo › Mooring/Anchoring
Issued 27 February 2002
Resolved
Provide adequate anchor rope to satisfaction of attending Marine Inspector. LEGACY COMPONENT DESC: Anchor Rope
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Navigation › Piloting/Steering
Issued 27 February 2002
Resolved
Provide current Light List or updates. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002
Resolved
Remove all dead end wires from under the console in the pilot house. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002
Resolved
Replace cover on electrical outlet under console on the pilot house. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Lifesaving › Lifebuoys
Issued 27 February 2002
Resolved
Replace line on life ring and provide metal clip. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002
Resolved
Repack (2) stuffing tubes on starboard side of forward bulkhead in engine room. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002
Resolved
Install metal tie wraps on wire runs in engine room. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002
Resolved
Provide non-conductive deck covering and handrail on switchboard in engine room. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Electrical › Electrical Distribution System (service)
Issued 27 February 2002
Resolved
Remove loose abandon wires in rudder room. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Engineering › Diesel Engine (auxiliary)
Issued 27 February 2002
Resolved
Repair fractures in exhaust piping in rudder room. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Construction/Loadline › Structures
Issued 27 February 2002
Resolved
Repair small holes in forward bulkhead of rudder room. LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Construction/Loadline › Structures
Issued 27 February 2002
Resolved
Repair cracks were handrail meets the deck midship starboard side. LEGACY COMPONENT DESC: Handrail
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 15 March 2002
Engineering
Issued 6 March 1998
Resolved
PROPERLY INSULATE MAIN ENGINE EXHAUST.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Lifesaving
Issued 6 March 1998
Resolved
RENEW RING BUOY AND EQUIPMENT.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Electrical
Issued 6 March 1998
Resolved
MAKE PERMANENT REPAIRS TO PILOT HOUSE EMERGENCY LIGHTING.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Unknown
Issued 6 March 1998
Resolved
MAKE CONSOLE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Navigation
Issued 6 March 1998
Resolved
MAKE PERMANENT REPAIRS TO JOCKEY BAR ON STEERING SYSTEM/PROPER PIN TO TILLER ARMS.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Electrical
Issued 6 March 1998
Resolved
REPAIR AMP METER ON PORT BATTERY CHARGER.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Fire Fighting
Issued 6 March 1998
Resolved
PROVIDE NEW FIRE HOSE AND NOZZLE.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Documentation
Issued 6 March 1998
Resolved
PROVIDE CURRENT COAST PILOT, LIGHT LIST AND CURRENT CHARTS OF OPERATING AREA.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 4 March 1997
Resolved
INSTALL PROPER BILGE PIPING IN WAY OF LAZARET._x001C_
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Engineering
Issued 4 March 1997
Resolved
REPLACE FUEL VENT SCREENING WITH 30X30 WIRE MESH._x001C_
Condition: Unknown
Due 4 March 1997
Resolved 4 March 1997
Accommodation/Occupational Safety
Issued 23 February 1995
Resolved
REMOVE TINTED WINDOWS AND REPLACE WITH CLEAR GLASS IN PILOT HOUSE IAW CID MEMO #56.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Documentation
Issued 23 February 1995
Resolved
PROVIDE VALID SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 23 February 1995
Resolved 23 February 1995
Documentation
Issued 24 February 1994
Resolved
COMPLETE ITEMS 1,2,5,10,13,16,17,23,24,25,28,29,31,36, ON WORKLIST ISSUED BY HARD ON 24FEB94 PRIOR TO CARRYING PASSANGERS OR CARGO BUT NOT LATER THAN01MAR94
Condition: Unknown
Due 1 March 1994
Resolved 7 March 1994
Construction/Loadline
Issued 11 April 1991
Resolved
REPAIR FWD. STARBOARD PORTION OF BOW VOID AS ORIGINAL. 3" X 3" HOLE ON DECKTO BE REPAIRED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Engineering
Issued 11 April 1991
Resolved
INSTALL OVERSPEED DEVICES ON BOTH MAIN DIESEL ENGINES (46CFR176.25)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991