CHICKASAW

Built
1970
Last inspected
15 September 2023
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 September 2023
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8758665
Flag
UNITED STATES
Maury page id
psix-46542

Documentation record

Registered dimensions (L × B × D)264.0 ft × 80.0 ft × 20.0 ft
Registered tonnagegross 3,781 / net 1,134
ITC dimensions (L × B × D)264.0 ft × 80.0 ft × 20.0 ft
ITC tonnagegross 3,781 / net 1,134
BuilderTODD SHIPYARDS CORP · HOUSTON, TX, UNITED STATES · built 1970
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPT ARTHUR, TX
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 1 October 2025 · expires 31 October 2026
Service, as the file records itIndustrial Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3781 - Convention (Subpart B), Gross Ton
1134 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 10 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

15 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7792446
7 July 2023 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7735832
31 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6768912
26 October 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6568944
8 August 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6533834
31 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6496529
24 May 2018 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6431146
24 April 2018 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6403026
3 November 2017 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6296953
14 June 2017 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6175836

Deficiency record · 14

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 July 2018 Resolved
COI Hull Exam dates overdue. Contact MSU Port Arthur to schedule drydock and internal examination. No industrial operations prior to completion. 46 CFR 91.40-3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 15 September 2023
Resolution: Vessel has been placed in an Inactive/laid up status and does not posses a valid COI.
Fire Fighting › Fire Pumps › Arrangement
Issued 3 November 2017 Resolved
Vessels shall be equipped with independently driven fire pumps in accordance with table 95.10-5(a), (2 pumps are required for vessels over 1500 GT). The main fire pump is inoperable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 29 May 2018
Resolution: Fire pumps were tested and found fully operational,
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 3 November 2017 Resolved
The installation of all systems of a marine engineering nature, with design, construction, and installation shall be as subchapter F. EMD generatio is exhausting oil onto maindeck.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 29 May 2018
Resolution: Generator oil leak was repaired and generator is operational
Lifesaving › Lifebuoys › Serviceable
Issued 14 June 2017 Resolved
04 LIFE RINGS REMOVED FROM SERVICE DUE TO DETERIORATION.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 19 June 2017
Electrical › Electric Generation Source (service) › Switch
Issued 14 June 2017 Resolved
EMERGENCY STOVE AND GRILL SHUTOFF REQUIRES MAINTANANCE AND TESTING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 19 June 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 June 2017 Resolved
MEDICINE IN HOSPITAL SPACE IS EXPIRED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 19 June 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 14 June 2017 Resolved
MAJORITY OF BERTH LIGHTS NOT OPERABLE AND NEED REPLACEMENT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 19 June 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 14 June 2017 Resolved
LIGHT IN ROOM 17 NEEDS TO BE HARD WIRED TO LIGHTING CIRCUIT.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2017
Resolved 19 June 2017
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 June 2017 Resolved
EMERGENCY LIGHTING AT STBD EMBARKATION STATION INOP.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 19 June 2017
Fire Fighting › Firemans Outfit › Boots
Issued 14 June 2017 Resolved
Fireman suit in machinery space is missing boots.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 July 2017
Resolved 19 June 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 14 June 2017 Resolved
Missing CO2 bottle for paint locker.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 July 2017
Resolved 19 June 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 14 June 2017 Resolved
Install hoses for CO2 distribution in the bow thruster room.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 July 2017
Resolved 19 June 2017
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 June 2017 Resolved
Smoke detector above paint locker nto installed correctly.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 14 July 2017
Resolved 19 June 2017
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 14 June 2017 Resolved
MSD must work.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 14 July 2017
Resolved 19 June 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.