Records from 1991 to 2025. Most recent: inspection, 18 November 2025.
Inspection history · 22
18 November 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8268947
9 July 2025
Damage Survey · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8180250
23 January 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8062578
3 October 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7803763
2 December 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7609209
26 January 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7385858
5 October 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7327047
12 June 2019
Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6711682
14 November 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6040791
5 June 2014
MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4887138
30 May 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4606156
23 April 2013
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4576099
4 March 2013
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4542819
4 October 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3124698
29 May 2007
MTSA/ISPS Verification · Uninspected Other
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2945039
10 January 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2272096
13 November 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2241488
19 October 2004
MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2228767
1 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1968483
15 February 1999
Type not recorded
No type recorded · CGC POINT SAL · USCG Heartland District (CGD-H) · Activity 1509461
22 February 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120345
19 August 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666538
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 November 2025
Resolved
When the towing vessel is underway, the EPIRB must be stowed in its float-free bracket with the controls set for automatic activation and be mounted in a manner so that it will float free if the towing vessel sinks. MI observed EPIRB stowed below structural overhead that could inhibit float free release.
46 CFR 141.380(b)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 November 2025
Resolved 18 November 2025
Resolution: Vsl rep switched EPIRB to a float free location.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 18 November 2025
Resolved
The line throwing appliances must have the equipment on the list provided by the manufacturer with the approved appliance. MI observed 02 line throwing appliances with missing projectiles.
46 CFR 141.385(b)(1)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 November 2025
Resolved 18 November 2025
Resolution: Vsl rep brought two projectiles from storage.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2025
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. MI observed a switchboard in the wheelhouse not properly installed.
46 CFR 143.400 (e)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 November 2025
Resolved 18 November 2025
Resolution: Vsl rep screwed on loose areas of switchboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port MDE has a fuel leak coming from the fuel rail. 46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Replaced seals on fuel rail, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port MDE fuel supply line has fuel leak, fuel hose is saturated in fuel oil. 46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Fuel was coming from leaking hose fitting above hose. Fitting was tightened, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. STBD MDE fuel supply has fuel leak in vicinity of the valve. 46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Fuel valve was found to be loose, valve was tightened and secured; all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. #3 Fuel tank transfer valve has significant fuel leak when operated. 46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Valve was rebuilt, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Fuel return line has multiple leaks, one of those is directly above steering pump controller. 46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Fuel line was found to be too short, longer fuel pipe was added alleviating leaks, controllers were replaced; all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2025
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Vessel STBD MDE has lube oil leak on turbos each side of the main. 46 CFR 143.220(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Turbo seals replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2025
Resolved
Each towing vessel must be maintained and operated to minimize fire hazards and to ensure the following: All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. STBD Bilge has excess accumulation of F/O. 46 CFR 142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Bilges were cleaned and free of fuel oil, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Main towing winch has oil leak on upper and lower clutches.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Leaks were corrected, containment was also added around clutches. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel A/C Unit is being held up by ratchet straps and not sufficiently supported. 46 CFR 143.205(a)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Metal bracket was added, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel has a sewage valve in the engine with a cracked body. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Sewage valve was replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 January 2025
Resolved
A fixed fire pump must be capable of: Delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute. Vessel's primary fire pump is inoperative. 46 CFR 142.325(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Pump was repaired, witnessed test; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Vessel was unable to get underway to conduct drills. 46 CFR 140.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Crew conducted MOB and fire drill; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Vessel's muster station and fire fighting staging is located on the 02 deck and does not have non skid or other slip proof deck which creates a significant hazard to the crew. 46 CFR 140.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Non skid decking was added to 02 deck; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2025
Resolved
The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed. Vessel has holes in the bulkheads on the port and STBD side of the engine room at the main deck. 46 CFR 144.200(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Holes were covered via bolts and hardware, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2025
Resolved
The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed. Port bunker station containment has wastage hole and not usable. 46 CFR 144.200(a)
Action required: 703 - Prior to bunkering operations
Resolved 31 January 2025
Resolution: Containment was repaired; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Both flame lockers have significant wastage and are no longer serviceable. 46 CFR 142.225(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Flammable lockers were replaced and relocated; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Vessel has gas cans and acetylene bottle improperly stowed on the 01 deck. 46 CFR 142.225(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Gas cans were properly stowed, acetylene bottle was removed; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 23 January 2025
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Vessel only has 2 of the required 4 charges on board. 46 CFR 141.385
Action required: 705 - Other - as specified
Resolved 31 January 2025
Resolution: Vessel added required charges; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
Each towing vessel must be fitted with a general alarm that: Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm—When Alarm Sounds or Flashes Go to Your Station”. Vessel does not have signage near the red flashing light in the Engine room. 46 CFR 143.235(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 31 January 2025
Resolution: Signage added; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
In general. - The responsible entity of a vessel shall report to the Commandant any complaint or incident of harassment, sexual harassment, or sexual assault in violation of employer policy or law, of which such entity is made aware. Vessel was unaware of CG reporting requirements and guidance and did not have posted signage. 46 USC § 10104(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 31 January 2025
Resolution: Vessal had signage posted; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Watertight doors do not have markings. 46 CFR 144.160(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 31 January 2025
Resolution: Markings added; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 January 2025
Resolved
The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed. STBD Damper has opening near electrical junction making it ineffective. 46 CFR 144.200(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Opening was closed; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: Have suitable propulsion controls to provide the operator full control at each operating station. Aft coning station panel has air lines removed leaving station inoperable. 46 CFR 143.205(c)(3)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2025
Resolution: Air lines replaced; all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 October 2023
Resolved
Except as required by §§140.900 and 140.905, records do not need to be filed with the
Coast Guard, but must be kept available for review by the Coast Guard upon request. Records, unless required to be maintained for a longer period by statute or other federal regulation, must be retained for at least 1 year after the date of the latest entry. Vessel log and crew records were not retrieveable for review prior to 1 Dec 2023, master was unable to open electronic records.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 January 2025
Resolution: Vessel was able to provide adequate records to MI.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 October 2023
Resolved
Each liferaft or must be arranged for float-free launching. The arrangement must ensure that the liferaft, when released and inflated, is not dragged under by the sinking vessel. A hydrostatic release unit used in a float-free arrangement must be approved. The HRU was rigged upside down, but corrected.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 19 December 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessels FP remote start located on the stbd side of the house was electrically live.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 October 2021
Resolution: Received report from TPO Sabine attesting to the repair and satisfactory operation of the exterior starboard remote start for the fire pump.