Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 12 May 2008
Resolved
Make repairs to the ventilation duct on the overhead of the paint locker to comply with "A-0" fire protection standard.
46CFR92.07-10(b) & 46CFR92.07-5(b)
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 12 August 2008
Resolution: Vessel installed a metal flap over ventilation duct in paint storage room. The flap is closable via pull cord located at the door. Operating instructions are posted.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 12 May 2008
Resolved
Provide a suitable B-V fire extinguisher to replace the current B-V fire extinguisher on the helicopter landing deck. Current extinguisher is no longer serviceable.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 12 August 2008
Resolution: Vessel replaced un-serviceable extinguisher with a new B-V fire extinguisher.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 May 2005
Resolved
Wires on the vessels port side wiring runs in the vicinity of the firing line need to be secured.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 9 May 2005
Resolution: Wires properly secured.
Construction/Loadline › Structures › Deck Plating
Issued 5 May 2005
Resolved
Repair or remove second bit from the aft of the vessel, on the vessel's port side.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 9 May 2005
Resolution: Bit removed.
Construction/Loadline › Structures › Deck Plating
Issued 5 May 2005
Resolved
Repair a support for the grating located on the vessel's fantail. The weld on the support was broken, and the support was hanging down towards the water.
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 9 May 2005
Resolution: Grating support repaired.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 4 May 2004
Resolved
Submit modified Fire Control Plan to cognizant OCMI office for review and approval to incorporate minor changes. Ensure modified deck arrangementss are properly accounted for on new plan.
Due 5 August 2004
Resolved 30 July 2004
Resolution: Performed a walk through of the vessel and checked all items marked in the vessel''s Fire Control Plan; reviewed updated Fire Control & Safety Plan and marked it as "APPROVED".
Fire Fighting › Fixed Fire Detection System
Issued 24 November 2003
Resolved
Fire Detection System inoperable. LEGACY COMPONENT DESC: Smoke Detectors
Action required: 705 - Other - as specified
Due 24 December 2003
Resolved 25 November 2003
Resolution: Proper operation of Fire Detection System proven.
Accommodation/Occupational Safety › Potable Water System
Issued 24 November 2003
Resolved
Potable Water piping not installed according to plans.
Action required: 705 - Other - as specified
Due 24 December 2003
Resolved 25 November 2003
Resolution: Installed satisfactory potable water piping IAW approved plans.
Pollution Prevention/Response › Prevention Equipment
Issued 3 June 2003
Resolved
Prove proper operation. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 3 June 2003
Fire Fighting
Issued 3 June 2003
Resolved
Provide proof of annual testing.
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 4 June 2003
Lifesaving › Lifejacket/PFD (General)
Issued 3 June 2003
Resolved
Provide 13 marker lights for PFDs. LEGACY COMPONENT DESC: Lights
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 4 June 2003
Documentation › Logs/Records
Issued 3 June 2003
Resolved
Provide documenation of air comperessor analysis reports for hyper-baric chamners.
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 4 June 2003
Lifesaving › Inflatable Liferafts
Issued 3 June 2003
Resolved
Secure both port side life rafts.
Action required: 705 - Other - as specified
Due 3 July 2003
Resolved 4 June 2003
Electrical › Electric Generation Source (emergency)
Issued 31 May 2002
Resolved
No overspeed or alarms installed on engine. LEGACY COMPONENT DESC: Prime Mover
Due 5 June 2002
Resolved 5 June 2002
Resolution: Installed Murphy Switchgage engine control system which contains an overspeed trip, low lube oil pressure, high water temp. alarms, buzzer and visual strobe light.
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 31 May 2002
Resolved
Prime mover bed frame fractured at left rear mount.
Condition: Unknown
Due 5 June 2002
Resolved 5 June 2002
Resolution: Prepared and re-welded.
Engineering › Fuel Oil Service System
Issued 15 May 2002
Resolved
20'+ rubber fuel oil hose installed in lieu of hard pipe. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 28 May 2002
Resolved 28 May 2002
Resolution: Removed hose.
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2002
Resolved
Several exhaust leaks noted on #1 and #2 SSDG's.
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Ships personnel repaired.
Electrical › Electric Generation Source (service)
Issued 15 May 2002
Resolved
#1 SSG, unused prime mover starter mount, missing blank off plate. Ring gear exposed to personnel. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed blank off plate.
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2002
Resolved
#2 SSG missing front crankshaft guard.
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed makeshift (Fan Grille) guard.
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2002
Resolved
Both SSDG's have missing/broken bolts on motor mounts.
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed replacement bolts.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 15 May 2002
Resolved
Faulty fire pump seal allowing raw water to spray fire pump electrical moter.
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Replaced faulty seal.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 15 May 2002
Resolved
Engine mounting bolts not installed on either SSDG. Engines were welded to beds. This was not in compliance with ABS requirements.
Condition: Improper Installation
Due 28 May 2002
Resolved 28 May 2002
Resolution: Bolts installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 May 2002
Resolved
Emergency lighting not installed for distribution panel in SSDG space.
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed fixture.
Engineering › Bilge Water Management System
Issued 15 May 2002
Resolved
Bilge alarm missing float linkage. LEGACY COMPONENT DESC: Interface Detector
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed linkage.
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2002
Resolved
#1 SSDG cooling water pipe hangers missing.
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed hangers
Electrical › Lighting (service) › Lighting Fixture
Issued 15 May 2002
Resolved
Light mounted to electrical wire run raceway outboard of #2 SSDG via wire tie straps.
Condition: Improper Installation
Due 28 May 2002
Resolved 28 May 2002
Resolution: Moved and mounted to overhead via mounting brackets.
Electrical › Electrical Distribution System (service)
Issued 15 May 2002
Resolved
Cover for 2' x 1' junction box hanging by wires off of box. LEGACY COMPONENT DESC: Junction Box Cover
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Secured cover to box.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 15 May 2002
Resolved
Blank missing.
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed blank.
Electrical › Electric Generation Source (service)
Issued 15 May 2002
Resolved
#1 SSDG Racor inlet and outlet fuel hoses worn. LEGACY COMPONENT DESC: Generator Fuel Hoses
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Replaced.
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2002
Resolved
Water pipe severely leaking at turbocharger.
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Tightened.
Engineering › Compressed Air System (start air)
Issued 15 May 2002
Resolved
No relief valve installed on SSDG start air receiver. LEGACY COMPONENT DESC: Relief Valve
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed relief valve. Tested Sat.
Engineering › Lubricating Oil Storage/Transfer System
Issued 15 May 2002
Resolved
Manhole cover on tank missing pipe plug. LEGACY COMPONENT DESC: Drain Tank Plug
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed plug.
Engineering › Fuel Oil Storage/Transfer System
Issued 15 May 2002
Resolved
Plug missing. LEGACY COMPONENT DESC: Tank Drain Plug
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Replaced.
Electrical › Electric Generation Source (service) › Generator
Issued 15 May 2002
Resolved
#1 SSGD expansion tank filler neck broken off of tank allowing hot jacket water to splash freely.
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Replaced/repaired filler neck.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 15 May 2002
Resolved
Pump leaking excessively, coupling guard not bolted down.
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Adjusted packing, installed bolts for guard.
Engineering
Issued 15 May 2002
Resolved
Only 2 bolts installed in 8 bolt flange. LEGACY COMPONENT DESC: Electric Keel Cooler Pump
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed missing bolts.
Engineering
Issued 15 May 2002
Resolved
Pecker head cover missing. LEGACY COMPONENT DESC: Electric Keel Cooler Pump
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed cover.
Engineering
Issued 15 May 2002
Resolved
Pump not mounted to foundation. LEGACY COMPONENT DESC: Electric Keel Cooler Pump
Condition: Improper Installation
Due 28 May 2002
Resolved 28 May 2002
Resolution: Mounted via weld.
Engineering
Issued 15 May 2002
Resolved
Pump not mounted to foundation LEGACY COMPONENT DESC: Black Water Xfer Pump
Condition: Improper Installation
Due 28 May 2002
Resolved 28 May 2002
Resolution: Mounted via weld.
Engineering
Issued 15 May 2002
Resolved
F/W pumps (2ea) in swg space not mounted to foundation. LEGACY COMPONENT DESC: F/W Pumps
Condition: Improper Installation
Due 28 May 2002
Resolved 28 May 2002
Resolution: Mounted via weld.
Engineering
Issued 15 May 2002
Resolved
Pump located in sewage space not mounted to foundation. LEGACY COMPONENT DESC: Salt Water Pump
Condition: Improper Installation
Due 28 May 2002
Resolved 28 May 2002
Resolution: Mounted via weld.
Engineering › Bilge Water Management System › Piping
Issued 15 May 2002
Resolved
Bilge piping wasted through, duct tape installed over this area. No rose box installed on suction end.
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Crop & renew piping, installed rose box.
Engineering › Diesel Engine (auxiliary)
Issued 15 May 2002
Resolved
Make shift lockwire installed on governor linkages, cooling water piping to radiator wasted. LEGACY COMPONENT DESC: Stbd Stern Winch
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Removed lockwire. Installed new cooling water pipe.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 15 May 2002
Resolved
No record of hydro for each of 4 pressure vessels installed for each of 4 winch engines. Ships rep removed in lieu of hydro.
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Pressure vessels removed.
Engineering › Diesel Engine (auxiliary)
Issued 15 May 2002
Resolved
Cooling water pipe to radiator wasted through. LEGACY COMPONENT DESC: Port stern winch
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Replaced pipe
Engineering › Diesel Engine (auxiliary)
Issued 15 May 2002
Resolved
Lockwire installed to hold various faulty control linkages on engine. LEGACY COMPONENT DESC: Port stern winch
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Lockwire removed, linkages repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 May 2002
Resolved
Fixture above starboard bow winch hanging by its power cable.
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Mounted fixture to bulkhead.
Engineering › Diesel Engine (auxiliary)
Issued 15 May 2002
Resolved
Red rubber air hose installed for fuel oil supply and return lines, hoses clamped on ends with hose clamps. LEGACY COMPONENT DESC: Port box winch
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed new hose approved for fuel oil service with crimped ends and threaded fittings.
Engineering › Diesel Engine (auxiliary)
Issued 15 May 2002
Resolved
One of three bolts, mounting starter motor to housing, missing LEGACY COMPONENT DESC: Port bow winch
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed replacement bolt.
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 15 May 2002
Resolved
Terminal protective panel missing from ESSG breaker box
Condition: Improper/Lack of Maintenance
Due 28 May 2002
Resolved 28 May 2002
Resolution: Installed panel.
Engineering › Compressed Air System (start air) › Compressor
Issued 15 May 2002
Resolved
Compressor locked up. Engineering personnel unsure how or when event occured.
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Repaired compressor.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 May 2002
Resolved
Terminal protective panel missing from breaker panel in eng. office.
Condition: Unknown
Due 28 May 2002
Resolved 28 May 2002
Resolution: Replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 May 2002
Resolved
Cover cut out sections used for UT testing in ceiling of all accomadation spaces
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 15 May 2002
Resolved
Install vent screens on outlets in all accomadation spaces
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 15 May 2002
Resolved
Install pipe hangers on PVC piping in showers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 15 May 2002
Resolved
Install guard on fan in shower
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 15 May 2002
Resolved
Remove excessive lint build up in laundry facility in shower room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 15 May 2002
Resolved
Repair exposed wiring on transformers in head.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 May 2002
Resolved
Repair raised hatch dog bushing on bow hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Superstructure
Issued 15 May 2002
Resolved
Repair wasted frames beneath helideck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Lifesaving › Inflatable Liferafts › Painter
Issued 15 May 2002
Resolved
Replace pelican hook to forward port side liferaft
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2002
Resolved
Repair deck plate by water tight hatch between generator and accomodation space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Superstructure
Issued 15 May 2002
Resolved
Crop and renew outboard frame to helodeck from forward stdb corner above paint locker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Superstructure
Issued 15 May 2002
Resolved
Crop and renew longitudinal frames above paint locker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Superstructure
Issued 15 May 2002
Resolved
Crop and renew transverse frame above paint locker
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Superstructure
Issued 15 May 2002
Resolved
Gas free and repair holes in paint locker. Maintain marine chemist's certificate and make available for inspectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Superstructure
Issued 15 May 2002
Resolved
Weld deck plate of helodeck to support frames of all loose areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2002
Resolved
Crop and renew trip plate for stdb ladder to helodeck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Superstructure
Issued 15 May 2002
Resolved
Crop and renew transverse frames to stbd aft corner by ladder to helodeck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2002
Resolved
Crop and renew plate on walkway port stern side of control room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2002
Resolved
Install fire retardant insulation around pipe in passageway between accomodation and machinery spaces
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Engineering › Fuel Oil Service System › Filter
Issued 15 May 2002
Resolved
Remove petcock valves from the bottom of all Racor fuel filters and install plugs or valves with plugs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Fire Fighting › Fire Hoses
Issued 15 May 2002
Resolved
Ensure all fire hoses meet the UL 19 standard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2002
Resolved
Hose test insert above #2 SSDG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 15 May 2002
Resolved
Install dryer vent in center machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 15 May 2002
Resolved
Re-pipe washing machine to drain (not to bilge)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 15 May 2002
Resolved
Hydrostatically test water heaters or install relief valves <100 psi.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Engineering › Pressure Vessel › Relief Valve
Issued 15 May 2002
Resolved
Pressure vessel/water heater above water heater on deck is missing relief valve and needs hydrostatic test
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 15 May 2002
Resolved
Provide marine chemist certificate for sewage room and any spaces requiring hot work.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 May 2002
Resolved
Provide hospital space in acordance with 46 CFR 92.20-35 or meet alternate compliance
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2002
Resolved
Provide proof of drug and alcohol testing program audit IAW 46 CFR 16
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2002
Resolved
Replace cover on forward flourescent light in control tower.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Engineering › Compressed Air System (control) › Compressor
Issued 15 May 2002
Resolved
Replace pressure gauge on #1 air receiver (diving air) so that maximun gauge pressure does not exceed 2x pressure relief valve IAW 46 CFR 54.15-5 (f).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2002
Resolved
Ensure ends of diving breathing supply hose are capped as per 46 CFR 197.456 (4).
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Engineering › Compressed Air System (control) › Compressor
Issued 15 May 2002
Resolved
Complete leak tests on dive chambers as per 46 CFR 197.462.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2002
Resolved 28 May 2002
Lifesaving
Issued 28 June 2000
Resolved
Provide sling for rescue boat to allow for ready availability for launching.
Condition: Unknown
Due 5 July 2000
Resolved 5 July 2000
Accommodation/Occupational Safety
Issued 28 June 2000
Resolved
Provide correct hospital space IAW 46 CFR 92.20-35(e).
Condition: Unknown
Due 5 July 2000
Resolved 5 July 2000
Lifesaving
Issued 28 June 2000
Resolved
Replace damaged hydrostatic release on #5 liferaft.
Condition: Unknown
Due 5 July 2000
Resolved 5 July 2000
Lifesaving
Issued 22 June 1999
Resolved
PROVE PROPER OPERATION OF THE GENERAL ALARM IN THE GENERATOR ROOM
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Electrical
Issued 22 June 1999
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY LIGHTING THROUGHOUT THE VESSEL
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Electrical
Issued 22 June 1999
Resolved
MAKE PREMANET REPAIRS TO EXHAUST AND OIL LEAKS
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Construction/Loadline
Issued 22 June 1999
Resolved
100% OF THE HEAD LOG WAS REPLACED DUE TO SEVERE WASTAGE AND PITTING
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Construction/Loadline
Issued 22 June 1999
Resolved
100% OF THE DECK MAKING UP THE BOW RAKE OVERHEAD WAS REPLACED DUE TO SEVEREWASTAGE, INCLUDING THE ADDITION OF 2 WATER TIGHT BULKHEADS, EFFECTIVELY DIVIDING THE COMMON BOW RAKE INTO 3 SEPARATE COMPARTMENTS (PORT, CENTER, AND STARBOARD)
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Electrical
Issued 22 June 1999
Resolved
CONDUCT A COMPLETE RENOVATION OF THE VESSELS ELECTRICAL SYSTEMS, INCLUDING BUT NOT LIMITED TO RERUNNING, MAKING PROPER REPAIRS TO, AND THE REMOVAL OF DEAD END WIRES
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Accommodation/Occupational Safety
Issued 22 June 1999
Resolved
REDUCE THE NUMBER OF PERSONS PER STATEROOM TO FOUR (4)
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Accommodation/Occupational Safety
Issued 22 June 1999
Resolved
INSTALL SUFFICIENT SHOWERS AND TOILETS TO ACCOMMODATE THE TOTAL PERSONS ALLOWED ON BOARD, (56)
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Fire Fighting
Issued 22 June 1999
Resolved
UPDATE AND SUBMIT FOR APPROVAL THE VESSELS FIRE AND SAFETY PLAN
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Lifesaving
Issued 22 June 1999
Resolved
MAKE PERMANET REPAIRS/REPLACE THE PAINT LOCKER WATERTIGHT DOOR
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Lifesaving
Issued 22 June 1999
Resolved
REARRANGE THE LIFERAFTS SO AS TO PROVIDE 50% LIFESAVING PROTECTION ON BOTH THE PORT AND STARBOARD SIDES INCLUDING EMBARKATION LIGHTS, LADDERS AND LAUNCHING INSTRUCTIONS.
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Construction/Loadline
Issued 22 June 1999
Resolved
30% OF PORT SIDE SHELL,INCLUDING WING VOID OVERHEADS, WAS REPLACED DUE TO SEVERE WASTAGE AND PITTING
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Construction/Loadline
Issued 22 June 1999
Resolved
15% OF THE STARBOARD SIDE SHELL, INCLUDING WING VOID OVERHEADS WAS REPLACEDDUE TO SEVERE WASTAGE AND PITTING.
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Construction/Loadline
Issued 22 June 1999
Resolved
70% OF THE BOTTOM PLATING WAS REPLACED DUE TO SEVERE WASTAGE AND PITTING
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Construction/Loadline
Issued 22 June 1999
Resolved
80% OF THE STERN APRON WAS REPLACED DUE TO SEVERE WASTAGE AND PITTING
Condition: Unknown
Due 22 June 1999
Resolved 29 June 1999
Engineering
Issued 3 April 1997
Resolved
RENEW OR REMOVE AIR RECEIVER ON COMPRESSOR DECK AND AIR RECEIVER IN PUMP ROOM WITH APPROVED TYPE AIR RECEIVERS. RENEWAL TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Documentation
Issued 3 April 1997
Resolved
SHOW EVIDENCE OF APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP) TOTHE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Deck/Cargo
Issued 22 May 1996
Resolved
AFFECT PERMANENT REPAIRS TO STBD STERN'S ABREAST ANCHOR SHEAVE'S FOUNDATION. CRACK IN FOUNDATION VISIBLE FROM UNDERNEATH IN STBD, AFT, OUTBOARD BALLAST TANK. CROP AND RENEW FRACTURED AREA DURING NEXT SCHEDULEDDRYDOCK.
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Deck/Cargo
Issued 22 May 1996
Resolved
AFFECT TEMPORARY REPAIRS TO STBD STERN'S ABREAST ANCHOR SHEAVE'S FOUNDATION. CRACK IN FOUNDATION VISIBLE FROM UNDERNEATH IN STBD, AFT, OUTBOARD BALLAST TANK.
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Fire Fighting
Issued 22 April 1996
Resolved
HELO DECK IS NOT TO BE USED UNTIL B-V IS REINSTALLED AND FIRE STATIONS ARE EQUIPED IAW 46 CFR 108.425 AND 108.486.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Accommodation/Occupational Safety
Issued 22 April 1996
Resolved
INSTALL A DOOR SAFETY SWITCH ON ELEVATOR DOOR IN PANTRY TO PREVENT OPERATION OF LIFT WHILE DOOR IS OPEN.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Construction/Loadline
Issued 22 April 1996
Resolved
MAKE REPAIRS TO AND PROVIDE APPROVED PLANS FOR BILGE AND ENGINE ALARM SYSTEM.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Electrical
Issued 22 April 1996
Resolved
INSTALL A LOCK-OUT BAR TO PREVENT BOTH GENERATORS FROM BEING ON LINE AT THESAME TIME.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Engineering
Issued 12 May 1995
Resolved
RETAIN ALL OILY-WATER MIXTURES ON BOARD WHEN AWAY FROM DOCK PENDING _x001C_ INSTALLATION OF AN APPROVED OILY-WATER SEPARATOR. INSTALLATION AND TESTING_x001C_SHALL BE TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Construction/Loadline
Issued 9 August 1993
Resolved
REPAIR/ REPLACE WASTED MAIN DECK WATERTIGHT HATCH TO GALLY ELEVATOR SHAFT.
Condition: Unknown
Due 23 August 1993
Resolved 30 August 1993
Documentation
Issued 12 July 1991
Resolved
PROVIDE EVIDENCE OF PLAN APPROVAL FOR TWENTY (20) TON CRANE INSTALLATION DRAWING (S-100) SUBMITTED TO CLASSIFICATION SOCIETY,(REFERENCE 46 CFR 91.37-20,) NOT LATER THAN 12 DECEMBER 1991
Condition: Unknown
Due 21 November 1991
Resolved 21 November 1991
Electrical
Issued 30 June 1990
Resolved
REPAIR GENERATOR OVERSPEED AND PROVE REVERSE POWER RELAY.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Electrical
Issued 30 June 1990
Resolved
REMOVE ALL REUSABLE FUSES FROM VESSEL AND REPLACE WITH REQUIRED SIZE ONE REUSABLE FUSES.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Deck/Cargo
Issued 30 June 1990
Resolved
PROVE CERTIFICATION OR RECERTIFY 150 TON CRANE AND CONDUCT A LOAD TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. ESTABLISH A CRANE RECORD BOOK PER 46 CFR 109.437.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Deck/Cargo
Issued 30 June 1990
Resolved
PROVE CERTIFICATION OR RECERTIFY 40 TON CRANE AND CONDUCT A LOAD TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR. ESTABLISH A CRANE RECORD BOOK PER 46 CFR 109.437.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Documentation
Issued 14 May 1987
Resolved
CORRECT PIPING DIAGRAM IN OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Construction/Loadline
Issued 14 May 1987
Resolved
LABEL ALL VALVES IN MACHINERY SPACES PARTICULARYLY THOSE UNDER DECK PLATES.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Navigation
Issued 14 May 1987
Resolved
PROVIDE FORWARD ANCHOR LIGHT OR OBTAIN CERTIFICATE OF ALTERNATIVE COMPLIANCE FOR ONLY ONE ANCHOR LIGHT.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Navigation
Issued 14 May 1987
Resolved
PROVIDE STERN LIGHT.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Construction/Loadline
Issued 14 May 1987
Resolved
MAKE PERMANENT REPAIRS TO DECK INSERTS IN BOW. SPECIFICALLY INSERTS SHALL SPAN TWO FRAMES AND HAVE RADIUSED CORNERS EXCEPT WHERE SEAMS MEET EXISTING SEAMS. INSERTS SHALL BE WELDED FROM BOTH SIDE (100% PENETRATION) AND TESTED WITH 30 PSI HOSE TEST.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Documentation
Issued 14 May 1987
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Documentation
Issued 14 May 1987
Resolved
PROVIDE HELO OPERATIONS MANUAL.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Unknown
Issued 14 May 1987
Resolved
SEAL HOLES FOR THE LIQUID LEVEL GAGE ACTUATOR ROD. IN THE TOP OF THE SEWAGE TANK.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Construction/Loadline
Issued 14 May 1987
Resolved
ADD BOTTOM FLAT BAR HORIZONAL STIFFENER BETWEEN STBD BOW CANT FRAMES.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Electrical
Issued 14 May 1987
Resolved
PROVIDE PHYSICAL PROTECTION ON SIGHT GLASSES FRO 01-DECK FUEL TANK AND GEN ROOM FUEL TANK.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Electrical
Issued 14 May 1987
Resolved
REPAIR EMERGENCY BATTERY OPERATED (SELF CONTAINED) LIGHTS IN PORT COMMUNICATION CORRIDOR, GEN ROOM, AND CENTER PUMP ROOM.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Construction/Loadline
Issued 14 May 1987
Resolved
REPAIR DECK INSERT IN WAY OF OLD CRANZ PEDESTAL TO SAME STRENGTH STANDARD AS MAIN DECK. CONSULT WITH MARINE INSPECTOR.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Fire Fighting
Issued 14 May 1987
Resolved
REPAIR OR REPLACE SEAL ON FIRE/BALLAST PUMP.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987