← All vessels
ADMIRAL PRIDE
ADMIRAL PRIDE is a 1997 freight ship. The Coast Guard has recorded 71 inspections since 1997, most recently in July 2026, along with 117 deficiencies and 4 operational controls.
Records from 1997 to 2026. Most recent: inspection, 8 July 2026.
- Built
- 1997
- Last inspected
- 8 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 117 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1060044
9184524 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5VFH5
465693
Flag
TOGO
303614000, 338433000, 368207000 (licence lapsed)
Maury page id
psix-465693
Inspections, by type
…with no type recorded10
Years with a record
26 calendar years (1997–2026)
The 71 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it1083 - Convention (Subpart B), Gross Ton
1684 - Dead Weight, Metric Ton
324 - Convention (Subpart B), Net Ton
974 - Displacement, Metric Ton
1684 - Dead Weight, Metric Ton
324 - Convention (Subpart B), Net Ton
974 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDG7881MMSI 338433000 · cancelled · compulsorily equipped · granted 24 April 2013, cancelled 18 July 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDB6408MMSI 303614000 · expired · compulsorily equipped · granted 7 February 2004, cancelled 12 April 2014 · licensed under a name not among this hull’s recorded names (not shown)
WCX8030MMSI 368207000 · cancelled · compulsorily equipped · granted 4 February 1998, cancelled 19 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 71
8 July 2026
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8432489
11 May 2026
Appeal
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8371093
30 April 2026
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8358560
15 January 2026
Deficiency Check · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8296388
9 July 2025
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8177907
11 June 2025
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8155536
6 June 2025
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8152622
8 January 2025
Deficiency Check · PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8057418
3 July 2024
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7944877
13 December 2023
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7837323
10 June 2023
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7709872
10 April 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7666038
10 April 2023
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7666595
1 December 2022
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7600687
1 June 2022
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7457160
21 November 2021
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7354749
19 May 2021
PSC B · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7197990
2 December 2020
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7105062
18 November 2020
PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7095178
13 May 2020
PSC A · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6951502
14 November 2019
Deficiency Check · Ballast Water Examination · PI Safety Exam · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6853551
10 July 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6743411
12 June 2019
ISPS III Exam · Ballast Water Examination · PI Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6709419
22 April 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6621452
22 January 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6612511
15 January 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6610916
9 January 2019
Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6607657
15 August 2018
PI Safety Exam · ISPS III Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6510797
31 May 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6428148
17 May 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6415242
12 April 2018
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6388876
13 March 2018
ISPS III Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6370701
1 March 2018
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6363756
30 October 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6297395
4 October 2016
Administrative Inspection
Administrative · Activities Europe · Activity 6015399
23 May 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6142388
3 May 2012
Internal Structural Exam · Construction Oversight · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4301036
17 February 2012
MARPOL Annex I Examination · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4246201
17 December 2010
Deficiency Check · MTSA/ISPS Verification · Drydock Exam · Periodic Inspection · Internal Structural Exam
Physical examination · Activities Europe · Activity 3892109
10 December 2010
Type not recorded
No type recorded · Activities Europe · Activity 3917749
8 December 2009
Annual Inspection
Physical examination · Activities Europe · Activity 3661782
1 April 2009
Type not recorded
No type recorded · Activities Europe · Activity 3444047
19 November 2008
Type not recorded
No type recorded · Activities Europe · Activity 3443417
16 November 2008
Annual Inspection
Physical examination · Activities Europe · Activity 3354827
8 November 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3359439
20 November 2007
Internal Structural Exam · COI Inspection · Hull Examination · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 3101458
18 September 2007
Administrative Inspection
Administrative · Activities Europe · Activity 3060271
18 October 2006
Annual Inspection
Physical examination · Activities Europe · Activity 2796073
6 January 2006
Periodic Inspection · Hull Examination
Physical examination · Activities Europe · Activity 2538864
24 February 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2298289
14 February 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2292057
12 January 2005
Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 2245802
21 May 2004
MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2057840
8 January 2004
Annual Inspection
Physical examination · Activities Europe · Activity 1896507
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970921
11 September 2003
Type not recorded
No type recorded · Activities Europe · Activity 1902251
15 August 2003
Type not recorded
No type recorded · Activities Europe · Activity 1876711
9 March 2003
Deficiency Check
Physical examination · Activities Europe · Activity 1777701
23 January 2003
COI Inspection
Physical examination · Activities Europe · Activity 1735489
11 January 2003
Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 1680393
27 January 2002
Re-Inspection
Physical examination · Activities Europe · Activity 1475045
17 September 2001
Administrative
Administrative · Activities Europe · Activity 1072104
24 May 2001
Type not recorded
No type recorded · Activities Europe · Activity 1064510
29 January 2001
Type not recorded
No type recorded · Activities Europe · Activity 1059032
29 January 2001
COI Inspection
Physical examination · Activities Europe · Activity 1366174
16 February 2000
Re-Inspection
Physical examination · Activities Europe · Activity 1433616
20 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124344
9 April 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467606
9 February 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473506
4 October 1998
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381345
22 December 1997
Initial Certification · Construction Oversight · Inclining Experiment · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402610
Deficiency record · 117
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 July 2026
Resolved
THE FOLLOWING BASIC PRINCIPLES... ARE EMBODDIED IN THE REGULATIONS AS APPROPRIATE, HAVING REGARD TO THE TYPE OF SHIPS AND THE POTENTIAL FIRE HAZARD INVOLVED, READY AVAILABILITY OF FIRE EXTINGUISHING APPLIANCES. PSCO OBSERVED THE EMERGENCY FIRE PUMP NOT READILY AVAILABLE.
74 SOLAS (97) II-2/2.2.7
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 8 July 2026
Resolved
HE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED ECDIS CHARTS THAT HAS NOT BEEN UPDATED SINCE 2022.
74 SOLAS (20) I/11(a)
16BC
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2026
Resolved
A FIREMAN'S OUTFIT SHALL CONSIST OF A SELF CONTAINED BREATHING APPARATUS WHICH SHALL BE CAPABLE OF FUNCTIONING FOR AT LEAST 30 MINS. PSCO OBSERVED ONE OF THE SCBA BOTTLES WITH INSUFFICIENT COMPRESSED BREATHING AIR.
74 SOLAS (97) II-2/17.1.2.2
16BC
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 8 July 2026
Resolved
CARGO SHALL BE LOADED, STOWED, AND SECURED THROUGHOUT THE VOYAGE IN ACCORDANCE WITH THE CARGO SECURING MANUAL APPROVED BY THE ADMINISTRATION. PSCO WAS UNABLE TO VERIFY THE CARGO ONBOARD WAS SECURED IN ACCORDANCE WITH THE CARGO SECURING MANUAL BECAUSE THE VESSEL DID NOT HAVE IT LISTED IN THE MANUAL.
74 SOLAS (20) VII/5
16BC
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 15 January 2026
Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the administration. In considering the design of such equipment, the administration shall have regard to the specification recommended by the organization. The vessel's OCM has not been calibrated in the last 5 years. The last calibration certificate expired on 26JUL2021.
MARPOL I/14.6
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 January 2026
Resolved
Indicators shall be provided for all sliding doors and for hinged doors in watertight bulkheads. The vessel's watertight door indicator panel on the bridge is inoperable.
74 SOLAS (97) II-1/ 23-1.1
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 11 June 2025
Resolved
While at Sea, the Radio Operator designated for radio communicationsduring distress incidents should ensure the proper functioning of the digital selective callingdistress by means of a test call at least onc each week. Chief Mate was unable to perform test call when requested by [name withheld] mate also stated he tests DSC via call once every two months.
STCW Part B Ch. VIII Reg 17.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 11 June 2025
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by Company. Ship was unable to provide a cyber security plan. Upon further review, iy was evident that a cyber security plan had not been incorporated into the SMS.
74 SOLAS (2020) IX/3.1
ISM Code 10.1
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 11 June 2025
Resolved
Mooring lines shall be of uniformed thickness throughout their length. During the deck walk, PSCO observed severe fraying of the Port Aft mooring line. Starboard mooring line is unbraided, compromising their strength.
33 CFR 401.10(a)(i)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 June 2025
Resolved
The mans of control of any fixed gas fire-extinguishing system shall be readily accessible.PSCO observed storage of multiple containers of SCBA and LSA appliances inside CO2 room.
74 SOLAS (1997) II-2/5.1.7
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 January 2025
Resolved
The means of securing doors weathertight shall consist of gaskets and clamping devices and shall b earranged that they can be operated from both sides of the bulkhead. PSCO observed weathertight door leading to portside escape hatch and 02 bulkhead doors leading to engine room that would not close.
ILLC Chapter II Reg 12
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 8 January 2025
Resolved
After survey no change shall be made to the structural arrangements and equipment without the sanction of the administration. PSCO observed hose attached to OWS which is used for testing the 15 PPM alarm when the bilge is empty. Hose is not desplayed on the manufacturer's diagram.
74 SOLAS (20) I/11
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 July 2024
Resolved
Fire protection systems and appliances shall be maintained ready for use. PSCO observed crew member unable to close ventillation to laundry room due to faulty bolt.
74SOLAS(2004)II-2/14.1.1
10c
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 November 2020
Resolved
Transfer hoses must be pressure tested annually. 33CFR156.170(f)(3)
Last test was cnducted in June 2019. Prior to conducting bunker operations in US waters, satisfactory test must be completed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 May 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The pelican hook used to strap the port side life raft into place was wasted.
SOLAS 1997 CH III/19.2
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 13 May 2020
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground. The deckline on starboard side was faded.
ILLC 1966 ANNEX I REG 8
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 14 November 2019
Resolved
For every ship to which chapter I applies, the administration shall issue an appropriate minimum safe manning document. Minimum safe manning document is expired onboard.
74SOLAS(14)V/14.2.2
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 November 2019
Resolved
The condition and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Engine room alarm panel did not relay alarms.
74SOLAS(14)/11(a)
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 14 November 2019
Resolved
Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. When testing OWS system content meter began reading and continued reading over 15ppm. PSC could not determine system operability.
MARPOL Annex I/14.6
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 14 November 2019
Resolved
The angular position of the rudder shall be recognizable in the steering gear compartment. Starboard rudder angular indicator was not operational.
74SOLAS(04)II-I/29.11.2
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2019
Resolved
No person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel tests and inspects the equipment annually. No evidence could be provided for the annual hydrostatic testing of the bunker lines. Proof of the hydrostatic testing is required prior to bunkering in The United States.
33CFR156.170(a)
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 9 January 2019
Resolved
For each ship subject to regulations 5 and 6 of this Annex, details of fuel oil for combustion purposes delivered and used on board shall be recorded by means of a bunker delivery note that shall contain at least the information specified in appendix V to this Annex. The ship carries fuel trucks to Tortola, BVI where the fuel trucks fuel the company’s other ships. A bunker receipt is provided for the transfer of fuel from the trucks to the ship, but the bunker receipt is missing the information required in appendix V, including: ship name; IMO number; date of commencement of delivery; port; sulphur content; declaration from fuel supplier; and density at 15 degrees Celsius, kilograms per cubic meter. MARPOL Annex VI 18.5, 17c
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 January 2019
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part 1, so that all entries in the book appropriate to that operation are completed. The Chief Engineer was logging entries incorrectly in accordance with the Oil Record Book instructions: each entry was missing operational Code and Item Numbers for bunkering of fuel oil and for reception of oily waste. MARPOL Annex I/17.4, 16ac
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 9 January 2019
Resolved
If the period of validity of a medical certificate expires in the course of a voyage, then the medical certificate shall continue in force until the next port of call where a medical practitioner recognized by the party is available. The master’s medical certificate expired on 16 December 2018, and this is the ship’s fifth port, including Tortola where a medical practitioner is available, call since the expiration of the medical certificate. STCW I/9.6 ; 40ac
01 - Certificates & Documentation › 011 - Ships Certificates › International Energy Efficiency Certificate
Issued 9 January 2019
Resolved
An International Energy Efficiency Certificate for the ship shall be issued after a survey in accordance with the provisions of regulation 5.4 of this Annex to any ship of 400 gross tonnage and above before that ship may engage in voyages to ports under the jurisdiction of other Parties. The owner/operator installed replacement engines during the dry-dock in July 2017, and the U.S. Coast Guard previously issued the ship a deficiency on 13 March 2018 due to missing Engine International Air Pollution Prevention Certificates for each engine. The last annual survey of the International Air Pollution Prevention Certificate was 28 February 2018, and the ship does not have an International Energy Efficiency Certificate. MARPOL Annex VI/6.4, 50ac
01 - Certificates & Documentation › 013 - Documents › Ship Energy Efficiency Management plan
Issued 9 January 2019
Resolved
Each ship shall keep on board a ship specific Ship Energy Efficiency Management Plan (SEEMP). This may form part of the ship’s Safety Management System (SMS). The ship does not have a separate SEEMP, and the Plan is not included in the ship’s SMS. MARPOL Annex VI/22.1, 50ac
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 August 2018
Resolved
On cargo ships, every liferaft, other than those required by regulation 26.1.4, shall be stowed with its painter permanently attached to the ship. The painter line was connected to the weak link in way of the yellow section of the hydrostatic release unit when the instructions clearly showed it should be attached to the red section. This arrangement would have delayed or prohibited automatic inflation and the condition was observed on both port and starboard liferafts. 74 SOLAS (1997) III/29
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
A HAZMAT employee must receive the training required by this subpart at least once every three years. The Master and Chief Mate do not have proof of HAZMAT training within the past three years. 49 CFR 172.704(c)(2)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
The Dangerous Cargo Manifest must contain all information required in the 49 Code of Federal Regulations. The Dangerous Cargo Manifest was missing numerous examples of information. 49 CFR 176.30(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 15 August 2018
Resolved
The Document of Compliance shall be issued by a Recognized Organization for a period not to exceed five years. The Recognized Organization issued the Document of Compliance without an issue date. 1974 SOLAS (2014) IX/ Reg 3.1 ISM Part B 13.13.2
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 15 August 2018
Resolved
Every ship for which chapter I applies shall be issued with a Continuous Synopsis Record. Vessel did not have a Continuous Synopsis Record issued. 1974 SOLAS (2014) XI-1/Reg 5.1
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 13 March 2018
Resolved
Each marine diesel engine shall be subject to a pre-certification survey which shall be such as to ensure that the engine as designed and equipped, complies with the NOx emission limits contained in regulation 13 of Annex VI. If this survey confirms compliance, the Administration shall issue an Engine International Air Pollution Prevention Certificate (EIAPP). Both of the propulsion engines were manufacturered in May 2012, and the vessel was not issued EIAPPs for each engine.
Documentation › Certificates/Documents › Construction and Equipment Certificate (DSC)
Issued 29 June 2012
Resolved
Provide approved drawings from ABS
Documentation › Certificates/Documents › Construction and Equipment Certificate (DSC)
Issued 29 June 2012
Resolved
Provide ABS 10-82 completion letter.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 17 February 2012
Resolved
Obtain Bunker Delivery notes and maintain file. Properly label bunker samples. Provide at COI inspection.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 February 2012
Resolved
Conduct SMPEP training/drill, inventory spill kit.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 17 February 2012
Resolved
Replace CO2 discharge hose to paint locker.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 February 2012
Resolved
Provide technicians report/captains statement that emergency steering rudder angle indicator is working in all modes.
Lifesaving › Rescue Boat › Propulsion Casing/Protection
Issued 17 February 2012
Resolved
Provide prop guard on FRC
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 17 February 2012
Resolved
Install turbo lagging (1 MDE and 1 SSDG)
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 17 February 2012
Resolved
Determine proper instalation (piping) and qty of bottles for CO2 system. Original plans show 15 bottles, currenly only 12 are connected to the system with 3 extra not connected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 17 February 2012
Resolved
Submit plans to MSC for approval of current CO2 system installation, make modifications as required
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 17 December 2010
Resolved
Repair Fire Detection System, prior to depature, battery charger inoperative, batteries dead. Received email dated 1/9/2011 concerning repair of ground fault and replacement of a capacitor. Deficiency to remain open to be verified at next attendance.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 17 December 2010
Resolved
Provide flash gear (NOMEX hoods) for fire fighting ensembles (2).
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 17 December 2010
Resolved
Provide flange shielding in fuel transfer/distribution piping side of pumps in accordance with SOLAS 74(amended) Reg II-2/4.2.2.5.3, crew has used tape on flanges, but require shielding where butterfly valves are fitted as well (special collars). Extended def due to shipping issues. Left def open to be verified at next annual inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 17 December 2010
Resolved
Remove connection between bow thruster fixed fire fighting system and engine room fixed fire system. Bow thruster CO2 activation simultaneously will activate time delay bypass on engine room CO2 system. Received email 1/10/2011 concerning removal of connection, left def open to be verified at next attendance.
Documentation › Logs/Records › Logbook (official)
Issued 17 December 2010
Resolved
Maintain USCG Official Log book, vessel is on a foreign voyage until it returns to US. Submit as necessary (once log is completed, or periodically) to USCG Activities Europe Will be verified at next inspections.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 17 December 2010
Resolved
Vessel is not manned in accordance with COI, vessel made the voyage from Soyo to Walvis Bay, a voyage over 600 miles with only 1 Mate, vice 2 as stated on COI. Vessel to be properly manned prior to departure from Walvis Bay.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 17 December 2010
Resolved
Provide record of annual thorough testing of rescue boat davit, prior to departure from Walvis Bay. Received email report 1/10/2011 concerning correction, and report issue date 1/3/2011. Left def open to be verified at next attendance.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 December 2010
Resolved
Provide light for starboard bridgewing man overboard lifebuoy (or replace with combi-light/smoke unit-vessel has two additional combi smoke/lights mounted on 01 Deck).
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 17 December 2010
Resolved
Provide fuel leakage alarms for double-jacketted fuel piping from external high-pressure injection pump to bridge and ECC for ship service generators and bow thruster engine in accordance with SOLAS II-2. (extended to next DD due to complexity)
Fire Fighting › Fire Hoses › Number
Issued 17 December 2010
Resolved
Provide 1 length of approved fire fighting hose to replace section which failed during pressure test prior to departure from Walvis Bay.
Construction/Loadline › Hull › Side Shell
Issued 17 December 2010
Resolved
Insert shell plating in way of fuel tank 1P as discussed with attending inspector. ABS to certify repair prior to departure from Walvis Bay.
Construction/Loadline › Hull › Side Shell
Issued 17 December 2010
Resolved
Insert side-shell plating in way of accomodation, 01 deck, stbd side, no later than next credit drydocking.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 24 March 2009
Resolved
Vessel failed to demonstrate proper rectification of non-conformity within time period stipulated by Flag State. Shore side support reported item as been rectified while Vessel reported non-conformity outstanding due to incompatible fittings of SCBA bottles to breathing apparatus. External ISM audit to be carried out by R.O. (ABS) focusing on the reporting and tracking of non-conformities.
Communications › Radio Communications › EPIRB
Issued 16 November 2008
Resolved
Vessel's EPIRB found registered with incorrect MMSI number and hailing port. Vessel to make notifications to nearest shore station (Cape Town) and NOAA. Proof of message receipt from nearest shore station required prior to departure from port.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 16 November 2008
Resolved
Waste oil being stored on deck in 50 GAL drums to be properly disposed of at shore facility. Drums not located on IOPP as approved storage space. No SOLAS DOC, for on deck stowage, on board. Remove within 7 days. 26 November 2008.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 18MAR09 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Provide on board two approved fireman's outfits within 30 days. 19 December 2008. **Extended to Jan 19, 2009**Extended to Feb 19, 2009**
Communications › Radio Communications › EPIRB
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 11DEC08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Vessel to provide on board an EPIRB with accurate registration information within 30 days. 19 December 2008.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 15DEC08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Provide corrective action plan to ensure proper operation of vessel's steering when operating in tandem. System is currently operating out of sync and rudder angle indicators found not reporting accurately. Provide within 30 days. 19 December 2008.
Lifesaving › Buoyant Apparatus › Approval
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 23APR09 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Provide on board two USCG approved ring buoys for quick release from bridgewings within 30 days. 19 December 2008. **Extended to Jan 19, 2009**Extended to Feb 19, 2009**Extended to March 19, 2009**Extended to April 19, 2009**Extended to April 24, 2009**
Documentation › Logs/Records › Oil Record Book
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 14MAR09 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Vessel has been utilizing USCG oil record book, ed. 07-93. Provide on board an up to date version of USCG oil record book within 30 days. 19 December 2008. **Extended to Jan 19, 2009**Extended to Feb 19, 2009**
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 05DEC08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Thinner/Paint locker (CO2 protected) found holed/wasted. Repair/replace as original within 30 days. 19 December 2008.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 November 2008
Resolved
Update CSR to reflect change in vessel operating company within 60 days. 19 January 2009.**Extended to Feb 19, 2009**Extended to March 19, 2009****Extended to April 19, 2009**Extended to May 18, 2009**Extended to June 19, 2009**
Operations/Management › Drills/Instruction › Fire
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 18JUN09 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Provide on board an updated/approved fire control plan which indicates class A and B fire boundaries within 90 days. 19 February 2009.**Extended to March 19, 2009****Extended to April 19, 2009**Extended to May 18, 2009**Extended to June 19, 2009**
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 18MAR09 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Vessel's side light screens to be painted matt black within 90 days. 19 February 2009.
Fire Fighting › Nozzles › Condition
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 16DEC08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Provide on board connecting chains for all high velocity fog adaptors navy all purpose nozzles within 90 days. 19 February 2009
Fire Fighting › Means of Escape › Blocked
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 27NOV08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Replace securing pin on emergency escape hatch (on deck) starboard side within 90 days. 19 February 2009.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 27NOV08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Label air/vent dampers aft of superstructure, so the order in which they are to be placed can easily be understood within 90 days. 19 February 2009.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 20MAR09 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Ring buoy hand lines and attachment lines are to be synthetic, resistant to deterioration from ultraviolet light, and dark in color. Place on board within 90 days. 19 February 2009.**Extended to March 19, 2009**
Construction/Loadline › Markings › Load Line Mark
Issued 16 November 2008
Resolved
Renew load line seasonal marks so as to conform with load line certificate within 90 days. 19 February 2009.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 13APR09 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Provide on board two buoyant floats for the line throwing apparatus, required by 46 CFR 133.170 and 46 CFR 160.040-4(a) within 90 days. 19 February 2009.**Extended to March 19, 2009****Extended to April 19, 2009**
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 24NOV08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Replace automatic door closure to class A fire door in galley within 90 days. 19 February 2009.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 05DEC08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Provide comprehensive operating manual for the rescue boat davit. 30 days.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 31DEC08 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Inventory and fully stock all first aid kits on vessel. 30 days. **Extended to Jan 1, 2009**
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 24APR09 and shall remain open until verified to be corrected by attending USCG Marine Inspector*Have all SCBA bottles hydro tested at an approved DOT factility, 30 days. **Extended to Jan 19, 2009**Extended to Feb 19, 2009**Extended to Apr. 21, 2009**Extended to April 24, 2009**
Lifesaving › Launching Appliances › Falls
Issued 16 November 2008
Resolved
*Item reported cleared via E-mail dated 17MAR09 and shall remain open until verified to be corrected by attending USCG Marine Inspector* Provide certification for rescue boat falls. 30 days. **Extended to Jan 19, 2009**Extended to Feb 19, 2009**Extended to March 19, 2009**
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 October 2006
Resolved
33U.S.C.1321(j)(5)(D)(iii)-The NTVRP does not identify a classified oil spill removal organization for the LA/Long Beach Captain of the Port zone
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 October 2006
Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge
33U.S.C.1321(j)(5)(D)(i)-The NTVRP does not identify the volume and type of fuel oil that would be involved in a worst case discharge
Fire Fighting › Ventilation Systems › Ducts
Issued 18 October 2006
Resolved
Make the fire damper on the 2nd deck accessible in case of fire.
22OCT06: Received Corrective Action Plan via email. An extension was added to make the fire damper accessible. Item will remain open until cleared by an inspector.
Fire Fighting › Ventilation Systems › Ducts
Issued 18 October 2006
Resolved
Repair the fire damper in the mess deck - stuck closed. Received Corrective Action Plan via email. Fire damper was repaired. Item will remain open until verified by an inspector.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 October 2006
Resolved
Remove all expired medications. 22OCT06: Received Corrective Action Plan via email. Expired medications were removed. Item will remain open until verified by an inspector.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 18 October 2006
Resolved
Remove crewmember with expired license.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 18 October 2006
Resolved
Prove proper operation of overspeed shutdown on the stbd main diesel engine.
Communications › Alarms/Indicators › Fire Alarm
Issued 18 October 2006
Resolved
Install glass on fixed firefighting pull handle in the forward tunnel. 22OCT06: Received Corrective Action Plan via email. New glass was installed. Item will remain open until verified by an inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 January 2006
Resolved
Prove proper operation of the oily water separator prior to departing Walvis Bay, Namibia. Report cleared via E-mail 30 Jan 2006, Item remains open until cleared by attending Marine Inspector.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 6 January 2006
Resolved
Prove proper operation of the high water temperature shut down on the MDE and SSG. Report cleared via E-mail dated 30 Jan, Item remains open until cleared by attending Marine Inspector.
Engineering › Lubricating Oil Service System › Cooler
Issued 6 January 2006
Resolved
Prove proper operation of the low lube oil pressure shut down on the MDE and SSG. Report cleared via E-mail dated 30 Jan, Item remains open until cleared by attending Marine Inspector.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 12 January 2005
Resolved
INSTALL EMERGENCY LIGHT TO CO2 CONTROL/STORAGE SPACE
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 12 January 2005
Resolved
RENEW FLAME SCREEN #2 PORT LIQUID MUD TANK.
Deck/Cargo › Ballast › Vents
Issued 13 May 2004
Resolved
Issued 11 deficiencies during ISPS/MTSA verification exam. Deficiency list attached to MISLE documents under the subject case yet not individually included in inspection results since they contain SSI
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 7 March 2004
Resolved
Repair fire screen doors to provide auto closure and auto latching ( areas of concern include: 01 deck to bridge, 01 deck port aft door and main deck stbd aft door, and main deck galley entry) LEGACY COMPONENT DESC: Accommodation Space Protection
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 7 March 2004
Resolved
repair inoperative A class rolling fire door for the galley passthrough window. LEGACY COMPONENT DESC: Cooking Area
Engineering › Compressed Air System (start air) › Compressor
Issued 7 March 2004
Resolved
replace inoperative relief valves for stbd pressure vessel. LEGACY COMPONENT DESC: Receiver/Bottle
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 7 March 2004
Resolved
Hydro test hoses per 33 CFR 156.170 (f)(3), to 1.5 times MAWP and mark hoses as required. LEGACY COMPONENT DESC: Transfer Hose
Communications › Alarms/Indicators › High Water Alarm
Issued 7 March 2004
Resolved
Provide equipment to test high jacket water temp alarms and shutdowns for main and aux engines. Prove system operation. LEGACY COMPONENT DESC: Jacket water high temp alarm
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 7 March 2004
Resolved
Provide means to test low lube oil alarms and shutdowns for aux generators. LEGACY COMPONENT DESC: Lube Oil Low Pressure Alarm
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 7 March 2004
Resolved
Provide means to test overspeed shutdown for emergency generator and prove proper operation. LEGACY COMPONENT DESC: Lube Oil Low Pressure Alarm
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 23 January 2003
Resolved
Mud tank flame screens damage/missing. Renew flame screens. LEGACY COMPONENT DESC: flame screens
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 January 2003
Resolved
Light fixture in CO 2 room not operating. Repair and prove proper operation of light fixture.
LEGACY COMPONENT DESC: Lighting Fixture
Navigation › Piloting/Steering
Issued 23 January 2003
Resolved
(1) Provide current compass deviation table as required by SOLAS chapter V regulation 12 LEGACY COMPONENT DESC: Compass Deviation Table
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 January 2003
Resolved
(2) Radar not operating properly. Trouble shoot repair and prove proper operation prior to returning vessel to service in accordance with 46CFR 130.310. LEGACY COMPONENT DESC: Radar
Communications › Radio Communications
Issued 23 January 2003
Resolved
(3) Provide NOAA registration for EPIRB and properly afix sticker to the EPIRB as required by 47CFR 80.1061(f) LEGACY COMPONENT DESC: EPIRB
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 23 January 2003
Resolved
(5) Shipboard Oil Pollution Emergency Plan missing approval page. Provide valid approval page for the SOPEP Manual. LEGACY COMPONENT DESC: SOPEP
Communications › Visual Communication › Warning Sign (radio room)
Issued 23 January 2003
Resolved
(6) Properly mark bow thruster CO2 discharge alarm "WHEN ALARM SOUNDS, LEAVE AT ONCE: CARBON DIOXIDE BEING RELEASED. In accordance with 46CFR 131.815. LEGACY COMPONENT DESC: Warning Sign
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 23 January 2003
Resolved
(7) Combustible materials stored behind main switch board. Remove items stowed behind the switch board.
Navigation › Piloting/Steering
Issued 25 January 2002
Resolved
PROVIDE CURRENT UPDATED USCG LIGHT LIST, SAILING DIRECTIONS, COAST PILOT, TIDES & CURRENT TABLES. LEGACY COMPONENT DESC: CURRENT NAVIGATION PUBS 2001/2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 25 January 2002
Resolved
PROVE PROPER OPERATION OF MAIN ENGINE OVERSPEED PROTECTION IAW APPROVED AUTOMATION TEST PROCEDURES. LEGACY COMPONENT DESC: OVERSPEED
Engineering › Compressed Air System (control)
Issued 25 January 2002
Resolved
REMOVE VALVE BETWEEN PORT DECK LOCKER AIR RECIEVER AND RELIEF VALVE ON AIR RECIEVER. LEGACY COMPONENT DESC: Valve
Accommodation/Occupational Safety › Occupational Safety
Issued 25 January 2002
Resolved
REPAIR/REPLACE EMERGENCY ESCAPE HATCH ASSIST SPRING FOR STARBOARD ESCAPE HATCH FROM ENGINE ROOM.
Lifesaving
Issued 24 May 2001
Resolved
Provide two (2) additional sixteen (16) person life rafts iaw SOLAS 74, as amended, Chapter III, Regulation 31. Rafts to be located port and starboard side of vessel.
Documentation
Issued 29 January 2001
Resolved
Provide Employee Assistance Program (EAP) Supervisory training for personnel in supervisory positions.
Engineering
Issued 29 January 2001
Resolved
HYDROSTATICALLY TEST ALL FUEL AND CARGO TRANSFER HOSES.
System not recorded
Issued 16 February 2000
Resolved
COMPLETE WORKLIST ITEMS ISSUED DURING REINSPECTION.
Lifesaving
Issued 9 February 1999
Resolved
INSTALL RESCUE BOAT, OR EQUIVILANT, AND DEMONSTRATE ABILITY TO RECOVER AN UNCONSCIOUS PERSON FROM THE WATER IAW 8TH DISTRICT POLICY LTR DTD 12NOV98.
Lifesaving
Issued 22 December 1997
Resolved
MAKE THE FOLLOWING MODIFICATIONS TO THE RESCUE SYSTEM: (1)REMOVE THE EXISTING GATE IN VSL BULWARK AND REPLACE WITH A REMOVALBE BOARD TYPE GATE. (2) ADD A STEP AFT OF THE BULWARK GATE. (3) PROVIDE MOUNTING BRACKETS FOR JACOB LADDER FWD OF GATE.
Lifesaving
Issued 22 December 1997
Resolved
PROVIDE ON BOARD VSL RESPONSE PLAN APPROVAL LETTER.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.