Inspection history · 56
16 December 2024
COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8046151
9 August 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7975318
20 February 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7868200
22 June 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7721690
13 March 2023
Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7650169
28 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7419933
15 December 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7368612
9 March 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7152576
10 December 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6870800
24 July 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6760932
9 May 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6703516
15 May 2018
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6414706
17 May 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6148389
23 March 2017
Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6105362
5 April 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5847771
25 June 2015
DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5162923
29 October 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5014174
27 September 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4993865
19 June 2014
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4897089
12 May 2014
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4856240
18 November 2013
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4755395
26 June 2013
Inclining Experiment
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4633080
20 June 2013
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4625395
7 June 2013
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4613522
10 October 2012
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4460673
3 August 2012
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4400119
28 March 2012
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4273873
20 March 2012
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4267823
3 June 2010
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3756448
24 June 2009
Hull Examination · Internal Structural Exam · Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3513045
24 June 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3246424
6 May 2008
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3200046
20 July 2007
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3001752
30 March 2007
COI Inspection · MARPOL Annex I Examination · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2898155
26 January 2007
In-Service Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2862398
24 January 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2861897
21 December 2006
Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2844446
7 November 2006
Deficiency Check · Load Line/Change of Employment
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2813020
7 November 2006
Hull Examination · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2816013
21 December 2005
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2555243
19 May 2005
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2384562
15 July 2004
Re-Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2133952
8 August 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1870129
15 November 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1705447
29 July 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1654542
24 June 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1635662
26 November 2001
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1458018
6 December 1999
Initial Construction-Excluding Oversight
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1460529
18 March 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 787627
23 April 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1386242
26 August 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1040318
22 June 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 892941
17 June 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203695
15 March 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1300025
8 January 1988
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1010295
15 September 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005159
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 December 2024
Resolved
Each pump must be capable of delivering water simultaneously from the two highest outlets at a Pitot tube pressure of approx 50 PSI; Fire pump would not operate; to repair pump in order to witness satisfactory operation of the pump and fire drill to assess crew competency.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2024
Resolution: Witnessed successful operation of fire pump at approx 110 PSI. Witnessed execution of fire drill, sat.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 16 December 2024
Resolved
On each cooking appliance, sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed. Sea rails to be installed on galley stove.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 June 2023
Resolved
The registers issued in connection with cargo gear certification must have all required entries fully completed as of the dates indicated, shall be kept current, and shall include the following: Certification of the testing and examination of cranes, hoists, and their accessory gear.
Received report that vessel obtained damage to crane as a result of an illusion with WEEKS 117 on 21JUN2023 at approximately 1345. Provide third party report attesting to satisfactory crane conditions.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 June 2023
Resolved 5 July 2023
Resolution: Provided tech report attesting to satisfactory operaional tests.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 December 2021
Resolved
In accordance with the COI "ONE OF THE CREW MUST BE KNOWLEDGEABLE IN THE LAUNCHING OF THE LIFERAFT AND SHALL BE DESIGNATED IN WRITING AS THE PERSON IN CHARGE. THIS DESIGNATION LETTER SHALL BE CARRIED ON THE BARGE WHEN IT IS OPERATING." Vessel missing designation letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2021
Resolved 3 January 2022
Resolution: Recieved PIC Designation Letter
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 December 2021
Resolved
Each muster station and embarkation station must be adequately illuminated by lighting with power supplied from the vessel's emergency source of electrical power. Vessel missing lighting at the muster and embarkation station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2021
Resolved 18 April 2022
Resolution: Received photo proving rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 9 March 2021
Resolved
Each vessel must carry an immersion suit for each person on board. 01 immersion suit was unfit for service and must be replaced. Barge is restricted to 05 total persons until an additional immersion suit is provided.
Action required: 705 - Other - as specified
Resolved 24 March 2021
Resolution: Received proof of additional immersion suit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021
Resolved
Dead end wiring was found in the mate shack. Remove wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2021
Resolution: Removed dead end wiring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021
Resolved
Electrical cable in the mate house was not jacketed. Renew the jacket to ensure proper protection of electrical wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2021
Resolution: Verified repaired cable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021
Resolved
Electrical cable in the engine room entering the JB-1 control box was not jacketed. Renew the jacket to ensure proper protection of electrical wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2021
Resolution: Verified repaired cable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 March 2021
Resolved
Temporary repair was discovered on the jacket water line elbow of the main hydraulic engine. Make permanent repairs and prove proper operation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 March 2021
Resolution: Verified permanent repair.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 March 2021
Resolved
The emergency escape hatch from the engine room is not marked internally, externally, or on the fire safety plan. Make proper markings and edits.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2021
Resolution: Verified proper markings.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 March 2021
Resolved
Oil Record Book is missing entries for disposal of oil residues and no master signature on completed pages. Crew stated oil residue was discharged ashore but failed to make ORB log entries for disposals made from Jan 2020 to inspection date. Make corrections and properly log ORB activities.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 March 2021
Resolution: Verified proper entries made.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 December 2019
Resolved
Each quick-acting watertight door must be made watertight. Ensure every watertight door/hatch onboard is made watertight and perform chalk-test in the presence of a marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2019
Resolution: Doors were checked by attending MI's
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2019
Resolved
Lifejackets must have a lifejacket life approved under approval sseries 161.112 securely attached to the front shoulder area of the life jacket. Vessel must replace old batteries in attached lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2019
Resolution: lights were checked for proper operaion by attending MI's
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 10 December 2019
Resolved
Each vessel required to carry immersion suits must carry suits approved under 161.153 that are of suitable size for each person assigned to a marine evacuation system crew. Immersion suits are not in suitable condition and must be made ready for donning in an emergency situation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 December 2019
Resolution: immersion suit zippers were checked for proper operaion by attending MI's
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 December 2019
Resolved
Each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. Vessel must provide a stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 March 2021
Resolution: Verified stability letter.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 10 December 2019
Resolved
Vessels engaged in domestic voyages by sea, not exempted by 46CFR42.03-5, are applicable to 46CFR subchapter E and must carry a load line certificate. Vessel must provide a load line certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 March 2021
Resolution: Verified load line.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 10 December 2019
Resolved
Valve actuators must be capable of closing fuel valves under all conditions. Make the fuel shut-down valve on the supply line at the day tank operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 20 December 2019
Resolution: remote operated F/O valve was repaired and was checked for proper operaion by attending MI's
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 10 December 2019
Resolved
On each cooking appliance, sea rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed. Install sea rails on galley stove.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 20 December 2019
Resolution: Sea rails were installed and checked by attending MI's
08 - Alarms › N/A - No Subsystem › General alarm
Issued 10 December 2019
Resolved
Marking required at stove disconnect and marking required at general alarm bell stating: "GENERAL ALARM-WHEN EMERGENCY ALARM SIGNAL RINGS GO TO YOUR STATION" in 1/2 inch letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 20 December 2019
Resolution: Required markings were placed where required
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 10 December 2019
Resolved
Each survival craft must be stowed so as not to require lifting from its stowed position in order to launch. Vessel must turn liferaft around and install the hydrostatic release correctly.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 9 March 2021
Resolution: Cleared
Communications › Radio Communications › VHF Radiotelephone
Issued 23 March 2017
Resolved
Provide FCC logbook to MI
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 19 April 2017
Resolution: Verified proper log entries onboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 March 2017
Resolved
Provide calibration report for Oil Content meter.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 19 April 2017
Resolution: Calibration report provided to MI
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 23 March 2017
Resolved
Update PIC list in transfer procedures
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 19 April 2017
Resolution: Updated PIC list provided to MI
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 23 March 2017
Resolved
Provide hydrostatic testing report for fuel hose.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 19 April 2017
Resolution: Hydro test report provided to MI.
Documentation › Logs/Records › Oil Record Book
Issued 23 March 2017
Resolved
Update Oil Record Bood to reflect current operations.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 19 April 2017
Resolution: ORB entries updated.
Lifesaving › Immersion Suits › Serviceable
Issued 23 March 2017
Resolved
Provide servicing report for 03 immersion suits
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 19 April 2017
Resolution: Service report provided to MI
Electrical › Lighting (service) › Outlet Box
Issued 23 March 2017
Resolved
Repair electrical installation at deck light on second deck.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 19 April 2017
Resolution: Pictures of repaired electrical box provided to MI
Engineering › Compressed Air System (control) › Valve
Issued 23 March 2017
Resolved
Provide report of bench test for safety relief valve on air receiver in crane.
Action required: 705 - Other - as specified
Due 23 April 2017
Resolved 19 April 2017
Resolution: Safety releif valve replaced onboard
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 6 April 2016
Resolved
Hydro transfer hose to 1.5x MAWP
Action required: 703 - Prior to bunkering operations
Resolved 7 April 2016
Resolution: Hydro test complete. All sat
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 6 April 2016
Resolved
Provide proper transfer procedures
Action required: 703 - Prior to bunkering operations
Resolved 7 April 2016
Resolution: Transfer procedures were onboard. All sat
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 10 October 2012
Resolved
Conduct hydro test of crane air receiver prior to use, to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 12 October 2012
Resolution: Witnessed satisfactory hydro.
Construction/Loadline › Hull › Weld
Issued 2 April 2012
Resolved
Provide repair proposal for all hull steel repiars made to the vessel.
Due 9 April 2012
Resolved 24 April 2012
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 March 2012
Resolved
Vessel is over due on Dry-dock and ISE exams. Vessel is prohibited from operating in commercial service until satisfactory exams are conducted.
Action required: 705 - Other - as specified
Resolved 24 April 2012
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 28 March 2012
Resolved
Prior to operation of crane house air receiver, test the setting of the relief valve.
Due 13 April 2012
Resolved 24 April 2012
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 28 March 2012
Resolved
Prior to operation of air receiver SER# 73018-33, provide and test relief valve which relieves at or below MAWP.
Due 13 April 2012
Resolved 24 April 2012
Lifesaving › Rocket Parachute Flares › General
Issued 28 March 2012
Resolved
Provide vessel with proper distress signals (12 rockets).
Due 13 April 2012
Resolved 24 April 2012
Lifesaving › Line-Throwing Appliances › Instructions/Diagrams
Issued 28 March 2012
Resolved
Provide vessel with line throwing appliance.
Action required: 705 - Other - as specified
Due 2 November 2012
Resolved 30 October 2012
Resolution: Witnessed 3 additional line throwing devices and 1,500 feet of line.
Construction/Loadline › Hull › Weld
Issued 28 March 2012
Resolved
Provide welder and steel certification for repairs completed.
Due 13 April 2012
Resolved 24 April 2012
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 March 2012
Resolved
Prove proper operation of the OWS oil content meter.
Due 13 April 2012
Resolved 11 April 2012
Resolution: Received calibration report from third party technician.
Construction/Loadline › Hull › Weld
Issued 28 March 2012
Resolved
Since work was not done by certified welders, perform ultrasonic testing on all weld repairs made to the vessel.
Due 9 April 2012
Resolved 24 April 2012
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 24 June 2009
Resolved
Demonstrate proper operation of vsl's pump room vent closure hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 June 2009
Resolved
Install a blank in hole in electrical panel in pump room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2009
Communications › Alarms/Indicators › General Alarm
Issued 24 June 2009
Resolved
Demonstrate proper operation of general alarm in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2009
Electrical › Electrical Distribution System (emergency) › Switch
Issued 24 June 2009
Resolved
Properly label all electrical motor controllers in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 24 June 2009
Resolved
Provide proof of annual hydrostatic testing of vsl's fuel oil and hydraulic fluid transfer hoses.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 June 2009
Resolved
Demonstrate proper operation of vsl's navigation lights on mast.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2009
Electrical › Electric Supply System (service) › Battery Charger
Issued 6 May 2008
Resolved
Dead end wire found hanging properly termanate
Condition: Improper/Lack of Maintenance
Due 8 June 2008
Resolved 8 May 2008
Resolution: Removed on site
Fire Fighting › Fire Hydrants › Material
Issued 6 May 2008
Resolved
Both Fire stations were missing spanners
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 24 June 2008
Resolution: Sited Spanners wrenches
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 May 2008
Resolved
Vessel OWS found inopertive vessel master master states he wants to removed it, Vessel to prove proper operation or remove
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 May 2008
Resolved 24 June 2008
Resolution: Sited proper operation of New Installed OWS
Communications › Radio Communications › EPIRB
Issued 6 May 2008
Resolved
EPIRB Not Reg with FCC
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 24 June 2008
Resolution: Sited EPRIB reg stickers and Mounting
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 July 2007
Resolved
Repair OWS sensing equipment and prove proper operation of same.
Condition: Unknown
Due 20 August 2007
Resolved 27 July 2007
Resolution: Cleared via Weeks Marine Safety Officer.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 20 July 2007
Resolved
Ensure excessive oil/water mixture is removed from lower E/R bilge area and properly transferred to slop tank for disposal. Bilge has excessive level due to previous failure of piping/valve on cooling line for hydraulic line.
Due 20 August 2007
Resolved 27 July 2007
Resolution: Cleared via Weeks Marine Safety Officer.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Charge Air Cooling
Issued 20 July 2007
Resolved
Make permanent repair to cooling water piping on MDE.
Condition: Improper/Lack of Maintenance
Due 20 August 2007
Resolved 27 July 2007
Resolution: Cleared via Weeks Marine Safety Officer.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 7 November 2006
Resolved
Demonstrate proper operation of vessel's installed OWS and 15-ppm monitoring equipment. (Ch. eng. and captain could not demonstrate proficient knowledge in OWS equipment, couldn't demostrate proper ops., OWS showed error signal on 2 successive recalibration sequences ("E7").)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Resolution: OWS and bilge monitor operationally tested SAT. Ch. eng. competent wrt use of the system.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 May 2005
Resolved
Vessel installed OWS could not be proven as operational sat. All oily wate to be retained on board until proof tested.
Condition: Improper/Lack of Maintenance
Due 30 December 2005
Resolved 13 November 2006
Resolution: OWS and bilge monitor operationally tested SAT.
Engineering › Fuel Oil Service System › Hose
Issued 19 May 2005
Resolved
Flexible non-metallic fuel service lines for supply and return on Diesel engines not to be more than 30" length
Condition: Improper Installation
Due 30 December 2005
Resolved 21 December 2005
Documentation › Certificates/Documents › Stability Letter
Issued 17 August 2004
Resolved
Provide original Stability Letter which reflect calculations from augmentations of year 2000 to date. Calculations must me issued by licensed Engineer.
Action required: 705 - Other - as specified
Due 17 September 2004
Resolved 17 August 2004
Resolution: Vessel provided Stabilty Letter from MSC which reflected stability calculations from augmentations made during year 2000.
Accommodation/Occupational Safety
Issued 26 November 2001
Resolved
Replace existing bolted deck hatch with escape scuttle from pump room. Install ladder steps in pump room and apply required markings and guards toensure escape is not covered with deck equipment. This item to be cleared prior to barge working as stated on COI.
Condition: Unknown
Due 20 December 2001
Resolved 24 June 2002
Resolution: Item cleared after receiving letter from Weeks Inc. along with pictures (attached) attesting to the installation of a emergency escape scuttle.
Accommodation/Occupational Safety
Issued 26 November 2001
Resolved
Prove proper operation of relief valve on stand-up air receiver in engine room.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Construction/Loadline
Issued 26 November 2001
Resolved
Provide standard oil discharge connection as required by 33 CFR 155.430.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Lifesaving
Issued 26 November 2001
Resolved
Provide USCG approved line throwing device with 4 spare shots as required.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Construction/Loadline
Issued 26 November 2001
Resolved
Repaint vessel draft markings prior to sailing.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Engineering
Issued 26 November 2001
Resolved
Prove proper operation of fuel cut-off reach rods (4) and label same prior to sailing.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Construction/Loadline
Issued 26 November 2001
Resolved
Prove proper operation of oily water separator equipment.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001