Records from 1995 to 2025. Most recent: inspection, 19 August 2025.
Documentation record
Registered dimensions (L × B × D)66.0 ft × 24.0 ft × 8.7 ft
Registered tonnagegross 92 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBERRY BROS GEN CONTRACTOR · BERWICK, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Simplified, Net Ton
92 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
19 August 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8213301
27 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7990383
4 March 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7880907
30 May 2023
Initial Certification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7691412
21 July 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7012267
21 March 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6134801
20 July 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5947847
9 December 2015
Administration · Deficiency Check · Examination of Repairs · Spot Check (Safety)
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5778292
9 December 2015
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5778400
27 October 2015
Industry Initiated Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5751585
29 October 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5015830
30 July 2012
Deficiency Check · DAPI Audit · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4395148
4 September 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3888825
24 January 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2861897
3 August 2006
Uninspected Other · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2740406
1 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2732594
14 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2279664
30 December 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2266523
25 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2009418
15 November 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212649
5 April 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 120683
15 March 2001
Type not recorded
No type recorded · CGC POINT SAL · USCG Heartland District (CGD-H) · Activity 1521077
14 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 76898
25 June 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 708488
17 June 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 212285
17 June 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 217063
1 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 118932
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2025
Resolved
The portable fire pump must be self-priming and power-driven, with: (1) A minimum capacity of at least 80 gpm at a discharge gauge pressure of not less than 60 psi, measured at the pump discharge. Portable fire pump was not fitted with a pressure gauge. 46 CFR 142.330(e)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2025
Resolved 2 September 2025
Resolution: vsl installed pressure gauge.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 August 2024
Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Main deck, portside engine room and galley; and starboard engine room hatches were found not closing watertight. 46 CFR 140.610(a) & (b). Code 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2024
Resolved 5 September 2024
Resolution: 2 watertight doors on port side and one on starboard side. Verified chalk test through photo.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 August 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port and starboard side throttle interlocks were found leaking. 46 CFR 143.220, Code 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 5 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 August 2024
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation.
1. Port main diesel generator crank case breather is missing hoses.
2. starboard main diesel engine exhaust leak.
3. starboard generator manifold exhaust leak.
4. starboard generator has a broken engine mount bolt.
5. port genertor jacket waterline chaffed.
46 CFR 143.205, COde 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 16 September 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 August 2024
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of 46 CFR 142.225. Remove all combustibles materials found stored in engine room. 46 CFR 143.220, Code 16C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 September 2024
Resolved 5 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2024
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Provide the unfired pressure vessel (UPV) data plate. 46 CFR 143.300, Code 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 13 September 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 27 August 2024
Resolved
Installed generators and motors must have a data plate listing rated kilowatts and power factor (or current), voltage, and rated ambient temperature. Diesel generators data plates were found to be painted over. 46 CFR 143.555, code 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 23 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. MI observed electrical panel in engine room missing cover.
46 CFR 143.400(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 2 June 2023
Resolution: Operator provided objective evidence that new electrical panel was install, with proper cover.