Records from 2001 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 96
28 April 2026
Vessel Attendance · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8357692
16 April 2026
Vessel Attendance · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8325307
18 February 2026
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8312347
17 February 2026
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8311304
31 January 2026
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8304388
21 January 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299786
12 November 2025
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8267654
10 November 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8266546
29 October 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8261212
28 October 2025
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8260425
27 August 2025
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8258334
15 August 2025
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8210833
30 July 2025
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8198051
1 November 2024
Vessel Attendance · Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8092485
10 September 2024
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8000220
9 May 2023
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7684094
21 April 2023
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7688779
28 March 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7660934
16 March 2023
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7651686
21 November 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7595098
19 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538192
19 July 2022
Re-Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7482532
5 June 2022
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7470453
5 June 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7470536
20 April 2022
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7435016
14 April 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7431419
15 March 2022
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412935
20 January 2022
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7382872
18 November 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7353718
8 November 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7347635
1 July 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7241861
23 April 2021
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7181110
22 April 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7181119
4 March 2021
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7158199
16 February 2021
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7117181
8 November 2020
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7095249
24 August 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7055878
25 May 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6959943
19 March 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6928034
3 December 2019
Examination of Repairs · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6870891
15 October 2019
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6832854
7 October 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6830741
26 August 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6795288
2 August 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6778194
2 July 2019
Re-Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6734146
29 May 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6702608
29 April 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6672903
18 April 2019
Deficiency Check · Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6665728
26 March 2019
Security Breach
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6685662
28 February 2019
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6642769
23 February 2019
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6631308
3 January 2019
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6605399
2 December 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6591243
20 November 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6588722
15 November 2018
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6581688
2 November 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6573791
18 October 2018
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6564116
14 September 2018
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6540772
24 August 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6522026
27 July 2018
Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6492850
7 May 2018
Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6436463
17 April 2018
Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6393986
14 March 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6372101
7 March 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6370553
23 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6360556
17 January 2018
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6331461
9 December 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6323045
20 September 2017
Administrative Inspection · Security Breach, Potential
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6348736
9 September 2017
Administrative Inspection · Security Breach, Potential
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6348722
30 July 2017
Administrative Inspection · Security Breach, Potential
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286454
29 July 2017
Security Breach · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286413
26 July 2017
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6221263
25 July 2017
MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6220391
25 July 2017
Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286226
24 July 2017
Administrative Inspection · Security Breach, Potential
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286199
11 May 2017
Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6168743
6 April 2017
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6118640
1 April 2017
Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117518
27 February 2017
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6095514
22 February 2017
Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6092875
10 February 2017
Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6086073
13 January 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6076247
5 January 2017
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6065675
6 December 2016
Re-Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6060216
6 October 2016
Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6018621
6 October 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6020325
9 August 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5967800
22 July 2016
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5949515
4 July 2016
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5937441
4 July 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6014624
12 April 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5865692
5 April 2016
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5848039
28 March 2016
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844858
3 March 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5827128
25 February 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5852005
17 February 2016
Periodic Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5816583
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 February 2026
Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate. #2 main engine is being repaired. Vessel is permitted to continue ferry operation with #2 M/E offline provided no loss of any one of the 3 remaining providers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2026
Resolved 4 March 2026
Resolution: MI attended to verify repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 January 2026
Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate. #1 ESS is to be repaired and proper operation proved to the satisfaction of attending CG Marine Inspector.
Vessel is permitted to continue ferry operation with #2 ESS online provided it and both MEs remain operational.
46CFR 58.01-35
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 23 April 2026
Resolution: Attended vessel and confirmed satisfactory operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 January 2026
Resolved
When alteration or repair of boilers, pressure vessels, machinery, safety valves or piping systems becomes necessary, the work shall be done under the cognizance of the Officer in Charge Marine Inspection...WSF reported the vessel was experiencing excessive vibrations and hydraulic oil loss on the #1 shaft's inner bearing. Properly troubleshoot the root cause of vibration and leaking oil and provide a repair proposal to the CG. Transit to Eagle Harbor/Bainbridge subject to MI approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2026
Resolution: Propelled was pressed back into tolerance, and sea trials conducted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 November 2025
Resolved
Means should be provided to continuously monitor the concentration of flammable and explosive gases in the battery space and alarm in the case of a hazardous concentration.
MI noted Battery Room No.2 H2 sensor is disabled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 12 December 2025
Resolution: Issue corrected.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 November 2025
Resolved
Carbon dioxide cylinders forming part of a fixed fire extinguishing system must be maintained as follows:Cylinders must be retested at least every 12 years.
MI noted CO2 bottle in Engineers Electrical shop missing 12 year maintenance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 19 December 2025
Resolution: Issue corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 November 2025
Resolved
Each vessel must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls that—
(a) Illustrate the purpose of controls;
(b) Illustrate the procedures for operating the launching device;
(c) Give relevant instructions or warnings;
(d) Can be easily seen under emergency lighting conditions; and(e) Display symbols in accordance with IMO Resolution A.760(18).
MI noted missing IBA launching instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 8 January 2026
Resolution: Laminated sheets from the FAST manual placed into MES lanching box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 November 2025
Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. #03 Generator experienced an overspeed that caused it to shutdown. Vessel to identify and rectify issue that caused generator to overspeed and shutdown. Provide root cause analysis prior to the carriage of passengers.
46CFR111.01-1(a)(2)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2025
Resolved 10 November 2025
Resolution: Governor limit swtich replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2025
Resolved
Make repairs and prove proper operation of the #2 end drive motors and control systems.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2026
Resolution: Varified with lead inspector for Act. 8210833 that this issue had been corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 July 2025
Resolved
Electric installations on vessels must ensure: Maintenance of services necessary for safety under normal and emergency conditions. #1 pilot house signal amplifier 2A not fully functional.
46CFR111.01-1(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2025
Resolution: MI attested to corrective repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2024
Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Cables going through Multi Cable Transit (MCT) between frames 18-19 above MCC No.1 switchboard in the engine room going into engineers shop to be inspected and Megger tested and all damaged cables to be replaced.
46CFR111.01-1(a)(2)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2025
Resolved 1 October 2024
Resolution: Issue corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 November 2022
Resolved
Air damper on the in port generator failed to close upon overspeed shut down. Service actuator to enable damper to function.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2022
Resolution: Unit serviced and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2022
Resolved
One of two Siemens control drive motors is inoperable. Control drive motor needs to be operational. A report attesting to the repairs is required to clear deficiency. 46CFR58.01-35
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2022
Resolved 23 July 2022
Resolution: Drive motor has been fixed and is now fully operational. The lack of proper shielding in this profibus cable allowed sufficient noise to occur in that cable that caused #1 Drive Motor to trip off-line on several occasions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 January 2022
Resolved
ALTERNATE SECURITY PLAN: A copy of this letter shall be retained on board the vessel or kept at the facility to which it pertains along with a copy of the Alternative Security Program.
Enrollment letter into ASP was not found on board vessel.
33 CFR 101.120(b)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2022
Resolution: WSF provided security documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 January 2022
Resolved
Exercises must be conducted at least once each calendar year, with no more than 18 months between exercises.
No proof of recent company exercise found on vessel. Provide documentation to satisfy requirement.
33 CFR 104.230(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2022
Resolution: WSF provided updated records.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 January 2022
Resolved
It shall be the duty of the owner, master, or person in charge to require and have performed at least once in every twelve months the tests and inspections of all hand portable fire extinguishers, semiportable fire extinguishing systems, and fixed fire extinguishing systems on board.
46 CFR 78.17-80(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 January 2022
Resolved
Each davit, winch, fall, and other launching appliance must be thoroughly inspected and repaired, as needed, once each year.
The #2 rescue boat launching device did not have updated yearly inspection documentation, please provide.
46 CFR 199.190(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2022
Resolved
All doors, except those that are kept normally closed, shall be of a type which are capable of release from the control station and from a position at the door.
Local release of the FSD-19 missing a part, making manual release of the FSD difficult. Repair as necessary.
46 CFR 72.05-25(b)(9)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 January 2022
Resolved
The lifejackets stowage positions must be marked with the words “LIFEJACKETS” or “CHILD LIFEJACKETS” as appropriate.
There were a few missing lifejacket placards throughout the vessel on the bench stowage locations. Please correct as necessary.
46 CFR 199.170(b)(2)(iii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 January 2022
Resolved
The in-port generator was OOC during the inspection. Prove the proper operation of the in-port via all applicable PSTPs to include CO2 system shutdown and power management systems prior to placing the generator back in service.
Action required: 705 - Other - as specified
Resolved 15 March 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 January 2022
Resolved
Mark the direction of operation of each watertight door level or wheel on both sides of the watertight door.
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2022
Resolved
Mark the direction of operation of each watertight door level or wheel on both sides of the watertight door.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2022
Resolved
Repair the ground on the T420 electrical panel.
Repair the No. 2 excitation fan for the No.1 drive motor.
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 January 2022
Resolved
Repair the motor operator on the E-Bus tie breaker. Manually charge after each use and verify charge status prior to putting the vessel in service each morning.
Action required: 705 - Other - as specified
Resolved 14 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2022
Resolved
Prove that the No.3 prop alternator can be connected using the No.1 tie breaker.
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2022
Resolved
Repair the No. 2 excitation fan for the No.1 drive motor.
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 January 2022
Resolved
Prove that the F/O instrumentation for the No. 3 & 4
prop alternator accurately displays the F/O pressure between the analog gauges and the AMS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 21 November 2022
Resolution: Verified that analog F/O gauges match digital AMS readouts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 April 2021
Resolved
Vessel experienced a crank case explosion on the #3 main engine and experienced a subsequent fire on the #2 end and had to be towed to Eagle Harbor. A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2021
Resolved 15 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 February 2021
Resolved
The electrical characteristics of each overcurrent protective device must be considered in the design of the entire protective system. Fire/bilge pump breaker has a 250 amp breaker installed, drawing lists a 200 amp breaker. Resolve descripancy. Replace with a correctly rated breaker
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2021
Resolved 2 July 2021
Resolution: Breaker replaced with proper size.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 February 2021
Resolved
The General alarm J-boxes on the #2 end sundeck under the piolot house and on the passender deck, #1 end are wated and not watertight. Repair to original condition. Additionally, one more J-box on the passenger deck, for 03 total.
46CFR111.01-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2021
Resolved 22 November 2022
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 October 2019
Resolved
Vessel has fixed fire suppression system installed in the galley range hood which was required for cooking appliances no longer installed in the galley. System was last serviced in January of 2018 and requires servicing every 12 months. Additionally, cylinder gauge is beginning to read in the red unsatisfactory zone. Fire systems installed but not required must be maintained in operational condition. System must either be serviced or removed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2019
Resolved 27 March 2020
Resolution: Vessel rep verified removal via photos.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2019
Resolved
If transformers are used to supply the ship's service distribution system there must be at least two installed, independent power transformers. The HT2 transformer for the ships service bus is not operational
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 28 August 2019
Resolution: Found and repaired a failed wire between the HT2 transformer and the contactor.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 2 July 2019
Resolved
46 CFR 71.55-1 / 50c - Wide areas of pitting corrosion were discovered at various areas on the car deck and upper passenger deck. A full gauging survey which shows the extent and depth of pitting on the car and passenger decks, including both the centerline and wing tunnels, must be completed and submitted to this office within 60 days.
The pitted areas must be inspected for cracking or structural deformation once a week and the results of this inspection must be sent to this office.
A repair plan must be submitted to address any plate which is pitted by more than a quarter of its original thickness. Any welding proposed as part of the repair plan must be conducted by qualified welders using an approved procedure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 19 March 2020
Resolution: Extended due date to 12/31/19, see narrative for more detail. [name withheld] and [name withheld] accepted temporary repair proposal with permanent repairs to be completed prior to the end of 2019.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 April 2019
Resolved
Sprinkler pipe in zone 4 at bulkhead of vehicle deck has hole requiring replacement of pipe section.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2019
Resolved 16 July 2019
Resolution: MIs confirmed that pipe was renewed. Conducted visual inspection weld. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2019
Resolved
Panelboard directories in pilothouse missing descriptions of some loads and circuit designations. All were missing rating of overcurrent devices on directories. Update all pilothouse panelboards to include complete directory information.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2019
Resolved 10 May 2019
Resolution: Panelboards relabeled and photos emailed to MI from WSF.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 18 April 2019
Resolved
Vehicles were parked blocking fire hose stations and passenger egress aisle spaces. Vehicles to be parked in accordance with loading policy and and painted lines. Discussed with 2nd Mate and Master, who will inspect closer in the future.
Action required: 10 - Deficiency Rectified
Resolved 19 April 2019
Resolution: Deck personnel counseled.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 18 April 2019
Resolved
Vehicles at ends of ferry not properly chocked as required. 2nd Mate counseled and corrected on spot.
Action required: 10 - Deficiency Rectified
Resolved 19 April 2019
Resolution: Deck crew counseled and corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 18 April 2019
Resolved
Galley reefer deck plate welds and rivets broken, creating trip hazard for galley staff. Fasten deck to remove hazard.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 2 May 2019
Resolution: Loose deck in reefer was fastened down and no longer loose with rivets
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2019
Resolved
Galley dry stores wall outlet GP204-13-B duct-taped over. Repair or renew to ensure no electrical hazard present.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 2 May 2019
Resolution: Electrical outlet tape removed and dry stores outlet inspected, found to be operating properly without hazard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 April 2019
Resolved
Self-closing door to passenger lounge on sun-deck weatherdeck not closing on its own. Adjust or renew to make self-closing in accordance with fire and life-saving plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 2 May 2019
Resolution: Weatherdeck door that was not shutting properly was adjusted by Eagle Harbor personnel and is once again self-closing
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2018
Resolved
Steering system reported by ship's crew as not working properly. Make necessary repairs to steering system and prove proper operation prior to carrying passengers. (46 CFR 58.25)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2018
Resolution: Witnessed proper operation of steering system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2018
Resolved
03 fire hoses burst under pressure. Replaced 03 hoses on scene; all sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2018
Resolved 15 November 2018
Resolution: Replaced 03 hoses on scene; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 July 2018
Resolved
While on board, found in the Watch Handover Notes the following entry: "#1 Rescue Boat Davit "Limit Switch" valve not working." Crew did not follow SMS procedure for documenting a non-comformity nor was USCG notified of this issue. No work order/requisition was made for this non-conformity. No resolution was identified on board. Master ([name withheld]) indicated that the vessel would be issued a non-conformity. Vessel is not in compliance with the SMS. Conduct an audit of the vessel's SMS and submit findings to the USCG.
Action required: 705 - Other - as specified
Due 10 August 2018
Resolved 24 April 2019
Resolution: Received documentation from WSF indicating that an internal SMS audit was conducted. Cleared CG-835.
Fire Fighting › Fire Hoses › Condition
Issued 17 January 2018
Resolved
Fire Station # 19, 22 and 40 had leaking hoses. Cut in front of inspector and replace with new. 46 CFR 76.10-10
Action required: 10 - Deficiency Rectified
Due 17 January 2018
Resolved 17 January 2018
Fire Fighting › Nozzles › Condition
Issued 17 January 2018
Resolved
Fire Station # 13 and 20 nozzles failed inspection. Replaced with new. 46 CFR 76.10-10(j)
Action required: 10 - Deficiency Rectified
Due 17 January 2018
Resolved 17 January 2018
Fire Fighting › Fire Hydrants › Condition
Issued 17 January 2018
Resolved
Fire Station # 33 had a leaking stem valve. Pipe shop repaired. 46 CFR 76.10-10
Action required: 10 - Deficiency Rectified
Due 17 January 2018
Resolved 17 January 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 January 2018
Resolved
Masthead and Port light alarm on No 1 End Panel did not work. Electrician corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 17 July 2018
Resolved 17 January 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 July 2017
Resolved
CHECK ALL BATTERIES IN LIFE-RING LIGHTS, REPLACE AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Resolution: All betteries checked, expired batteries removed from vessel
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2017
Resolved
PROPERLY TERMINATE OR REMOVE DEAD END WIRE IN GALLEY
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 July 2017
Resolved
REPAIR OR REPLACE FIRE EXTINGUISHER #54A PLEXY GLASS.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 2 August 2017
Communications › Internal Communications System › Engine Order Telegraph System
Issued 5 January 2017
Resolved
Engine order telegraph on the # 2 end does not have an audible alarm when the order and answer arrows do not match.
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 27 February 2017
Engineering › Electric Propulsion System › Circuit Board
Issued 6 October 2016
Resolved
Make perminant proper repairs to SIMADYN D system on #1 end and test prior to opperations with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2016
Resolution: Replaced faulty communications link circut card was replaced by tech rep. Test was sat in the presence of Attending Marine Inspector.
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 6 October 2016
Resolved
Safety trip controls at ECC and both pilot house locations are not independant and must be seperate from systems that they protect. Make controls independant to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 31 July 2025
Resolution: Remote propulsion cantrol system replaced during hybridization project summer of 2026. Non compliant configuaration removed.
Construction/Loadline › Hull › Hull Plating
Issued 4 July 2016
Resolved
Vsl has inset in #2 End starboard bow rub rail. Deck plate, overhanging plate, and longitudinal stiffener in steering gear room are buckled 3-4 inches. Repair no later than next drydock in July 2018.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 July 2018
Resolved 20 January 2017
Resolution: Damaged area cropped and renewed to original scantling.
Lifesaving › Launching Appliances › Davit
Issued 5 April 2016
Resolved
Launch #2 rescue boat at the #1 end. Vessel unable to launch at COI due to obstruction of pier.
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 11 April 2016
Resolution: Boat successfully launched and recovered.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 April 2016
Resolved
02 Emergency lights did not operate and must be replaced.
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 8 April 2016
Resolution: Lights replaced and operational.