WENATCHEE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 225 inspections since 1998, most recently in April 2026, along with 112 deficiencies, 1 operational control and 29 casualty investigations between 2001 and 2025.

Records from 1998 to 2026. Most recent: inspection, 28 April 2026.

Built
1998
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9137351 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY3378
467684
Flag
UNITED STATES
366749710
Maury page id
psix-467684

Inspections, by type

…with no type recorded62
Years with a record 28 calendar years (1998–2026)
The 225 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)440.0 ft × 89.8 ft × 25.8 ft
Registered tonnagegross 3,926 / net 2,066
ITC dimensions (L × B × D)440.0 ft × 89.8 ft × 25.8 ft
ITC tonnagegross 12,689 / net 5,426
BuilderTODD SHIPYARD · SEATTLE WA, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3926 - Regulatory (Subpart C or D), Gross Ton
12689 - Convention (Subpart B), Gross Ton
2066 - Regulatory (Subpart C or D), Net Ton
5426 - Convention (Subpart B), Net Ton
1393 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY3378MMSI 366749710 · active · compulsorily equipped · granted 13 March 2018, expires 28 April 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SIOUX ARROW Passenger (Inspected) · MISLE 47072 · 1 March 2010 · activity 3687904

Inspection history · 225

28 April 2026 Vessel Attendance · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8357692
16 April 2026 Vessel Attendance · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8325307
18 February 2026 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8312347
17 February 2026 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8311304
31 January 2026 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8304388
21 January 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299786
12 November 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8267654
10 November 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8266546
29 October 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8261212
28 October 2025 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8260425
27 August 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8258334
15 August 2025 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8210833
30 July 2025 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8198051
1 November 2024 Vessel Attendance · Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8092485
10 September 2024 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8000220
9 May 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7684094
21 April 2023 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7688779
28 March 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7660934
16 March 2023 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7651686
21 November 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7595098
19 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538192
19 July 2022 Re-Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7482532
5 June 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7470453
5 June 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7470536
20 April 2022 Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7435016
14 April 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7431419
15 March 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7412935
20 January 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7382872
18 November 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7353718
8 November 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7347635
1 July 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7241861
23 April 2021 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7181110
22 April 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7181119
4 March 2021 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7158199
16 February 2021 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7117181
8 November 2020 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7095249
24 August 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7055878
25 May 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6959943
19 March 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6928034
3 December 2019 Examination of Repairs · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6870891
15 October 2019 Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6832854
7 October 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6830741
26 August 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6795288
2 August 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6778194
2 July 2019 Re-Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6734146
29 May 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6702608
29 April 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6672903
18 April 2019 Deficiency Check · Administrative Inspection · MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6665728
26 March 2019 Security Breach
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6685662
28 February 2019 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6642769
23 February 2019 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6631308
3 January 2019 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6605399
2 December 2018 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6591243
20 November 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6588722
15 November 2018 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6581688
2 November 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6573791
18 October 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6564116
14 September 2018 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6540772
24 August 2018 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6522026
27 July 2018 Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6492850
7 May 2018 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6436463
17 April 2018 Periodic Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6393986
14 March 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6372101
7 March 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6370553
23 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6360556
17 January 2018 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6331461
9 December 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6323045
20 September 2017 Administrative Inspection · Security Breach, Potential
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6348736
9 September 2017 Administrative Inspection · Security Breach, Potential
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6348722
30 July 2017 Administrative Inspection · Security Breach, Potential
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286454
29 July 2017 Security Breach · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286413
26 July 2017 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6221263
25 July 2017 MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6220391
25 July 2017 Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286226
24 July 2017 Administrative Inspection · Security Breach, Potential
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286199
11 May 2017 Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6168743
6 April 2017 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6118640
1 April 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6117518
27 February 2017 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6095514
22 February 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6092875
10 February 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6086073
13 January 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6076247
5 January 2017 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6065675
6 December 2016 Re-Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6060216
6 October 2016 Administrative Inspection · Examination of Repairs · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6018621
6 October 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6020325
9 August 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5967800
22 July 2016 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5949515
4 July 2016 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5937441
4 July 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6014624
12 April 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5865692
5 April 2016 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5848039
28 March 2016 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5844858
3 March 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5827128
25 February 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5852005
17 February 2016 Periodic Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5816583
16 October 2015 Internal Structural Exam · Drydock Exam · Construction Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5744626
24 September 2015 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5728887
24 August 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5224862
10 August 2015 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5211792
23 July 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5194335
22 October 2014 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5011569
22 October 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5012820
14 October 2014 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5004865
12 October 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5003786
25 August 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4965279
21 August 2014 Type not recorded
No type recorded · Maritime Safety & Security Team Seattle (91101) · Activity 4962597
20 August 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4960831
3 August 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4943564
3 May 2014 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4850902
3 May 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4851229
28 June 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4360993
2 May 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4300444
9 February 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4242199
9 February 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4264582
5 February 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4238834
26 January 2012 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4226273
6 January 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4220098
5 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4201835
3 December 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202196
20 September 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4150948
29 August 2011 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4140463
13 August 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4114743
29 July 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4101698
21 July 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4089660
17 July 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4085894
14 July 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4081968
25 February 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3952608
15 February 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3946004
31 January 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3936792
18 January 2011 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3928154
25 October 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3877066
24 September 2010 Re-Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3862984
12 September 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3849251
11 September 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3849248
1 March 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3687904
8 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3707420
21 January 2010 Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3668111
20 July 2009 Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3541420
14 April 2009 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3453173
15 January 2009 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3392957
22 October 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3350961
17 October 2008 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3346602
25 July 2008 Deficiency Check · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3278800
11 July 2008 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3264572
24 February 2008 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3161387
31 January 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3140230
23 January 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3134796
17 January 2008 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3127937
23 October 2007 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3089798
18 October 2007 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3083024
9 July 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2991604
26 April 2007 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2916045
19 April 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2911273
9 February 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2869700
16 January 2007 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2856356
27 September 2006 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2788480
5 July 2006 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2702619
18 April 2006 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2627573
18 April 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2628403
12 January 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2565954
5 January 2006 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2559774
12 December 2005 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2550240
22 September 2005 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2498970
11 July 2005 MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2423321
11 July 2005 MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2423358
24 June 2005 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2404877
28 March 2005 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2324795
28 February 2005 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2300947
22 December 2004 Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2263140
17 November 2004 Spot Check · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2242776
5 November 2004 MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2235474
21 July 2004 Re-Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2139651
18 June 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2102506
30 March 2004 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2034109
5 February 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2006362
27 January 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1996046
17 December 2003 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1965841
1 November 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1965905
14 October 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1928390
7 July 2003 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1834310
29 April 2003 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1782714
5 February 2003 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1739634
20 December 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1721747
26 November 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1713262
17 October 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1690712
23 September 2002 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1679251
3 September 2002 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1668848
30 May 2002 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1624468
22 May 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1622106
20 May 2002 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1618705
27 March 2002 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1599058
28 December 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1657109
20 November 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1425240
20 August 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 76171
26 July 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 8920
10 July 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1417322
28 June 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 177735
18 May 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 114217
20 April 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1366286
12 April 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1469030
20 January 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 481503
18 January 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1406846
30 October 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 823078
28 July 2000 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1420369
19 July 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1430890
16 July 2000 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1051593
6 July 2000 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1426430
2 July 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 117531
5 May 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 184116
20 April 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1361417
21 January 2000 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 815180
22 December 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 813445
2 November 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 17558
13 September 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 39218
14 June 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1429158
16 April 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 789582
26 February 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 6913
23 February 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1446726
22 February 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 795941
19 November 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1393031
29 October 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 169839
19 August 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1423066
7 August 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 75534
22 May 1998 Initial Certification · Hull Examination · Deadweight Survey · Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788660

Deficiency record · 112

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 February 2026 Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate. #2 main engine is being repaired. Vessel is permitted to continue ferry operation with #2 M/E offline provided no loss of any one of the 3 remaining providers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2026
Resolved 4 March 2026
Resolution: MI attended to verify repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 January 2026 Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate. #1 ESS is to be repaired and proper operation proved to the satisfaction of attending CG Marine Inspector. Vessel is permitted to continue ferry operation with #2 ESS online provided it and both MEs remain operational. 46CFR 58.01-35
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2026
Resolved 23 April 2026
Resolution: Attended vessel and confirmed satisfactory operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 January 2026 Resolved
When alteration or repair of boilers, pressure vessels, machinery, safety valves or piping systems becomes necessary, the work shall be done under the cognizance of the Officer in Charge Marine Inspection...WSF reported the vessel was experiencing excessive vibrations and hydraulic oil loss on the #1 shaft's inner bearing. Properly troubleshoot the root cause of vibration and leaking oil and provide a repair proposal to the CG. Transit to Eagle Harbor/Bainbridge subject to MI approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2026
Resolution: Propelled was pressed back into tolerance, and sea trials conducted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 November 2025 Resolved
Means should be provided to continuously monitor the concentration of flammable and explosive gases in the battery space and alarm in the case of a hazardous concentration. MI noted Battery Room No.2 H2 sensor is disabled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 12 December 2025
Resolution: Issue corrected.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 November 2025 Resolved
Carbon dioxide cylinders forming part of a fixed fire extinguishing system must be maintained as follows:Cylinders must be retested at least every 12 years. MI noted CO2 bottle in Engineers Electrical shop missing 12 year maintenance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 19 December 2025
Resolution: Issue corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 November 2025 Resolved
Each vessel must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls that— (a) Illustrate the purpose of controls; (b) Illustrate the procedures for operating the launching device; (c) Give relevant instructions or warnings; (d) Can be easily seen under emergency lighting conditions; and(e) Display symbols in accordance with IMO Resolution A.760(18). MI noted missing IBA launching instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 8 January 2026
Resolution: Laminated sheets from the FAST manual placed into MES lanching box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 November 2025 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. #03 Generator experienced an overspeed that caused it to shutdown. Vessel to identify and rectify issue that caused generator to overspeed and shutdown. Provide root cause analysis prior to the carriage of passengers. 46CFR111.01-1(a)(2)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 November 2025
Resolved 10 November 2025
Resolution: Governor limit swtich replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2025 Resolved
Make repairs and prove proper operation of the #2 end drive motors and control systems.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2026
Resolution: Varified with lead inspector for Act. 8210833 that this issue had been corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 July 2025 Resolved
Electric installations on vessels must ensure: Maintenance of services necessary for safety under normal and emergency conditions. #1 pilot house signal amplifier 2A not fully functional. 46CFR111.01-1(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2025
Resolution: MI attested to corrective repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2024 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Cables going through Multi Cable Transit (MCT) between frames 18-19 above MCC No.1 switchboard in the engine room going into engineers shop to be inspected and Megger tested and all damaged cables to be replaced. 46CFR111.01-1(a)(2)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2025
Resolved 1 October 2024
Resolution: Issue corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 November 2022 Resolved
Air damper on the in port generator failed to close upon overspeed shut down. Service actuator to enable damper to function.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 November 2022
Resolution: Unit serviced and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2022 Resolved
One of two Siemens control drive motors is inoperable. Control drive motor needs to be operational. A report attesting to the repairs is required to clear deficiency. 46CFR58.01-35
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2022
Resolved 23 July 2022
Resolution: Drive motor has been fixed and is now fully operational. The lack of proper shielding in this profibus cable allowed sufficient noise to occur in that cable that caused #1 Drive Motor to trip off-line on several occasions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 January 2022 Resolved
ALTERNATE SECURITY PLAN: A copy of this letter shall be retained on board the vessel or kept at the facility to which it pertains along with a copy of the Alternative Security Program. Enrollment letter into ASP was not found on board vessel. 33 CFR 101.120(b)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2022
Resolution: WSF provided security documents.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 January 2022 Resolved
Exercises must be conducted at least once each calendar year, with no more than 18 months between exercises. No proof of recent company exercise found on vessel. Provide documentation to satisfy requirement. 33 CFR 104.230(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2022
Resolution: WSF provided updated records.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 January 2022 Resolved
It shall be the duty of the owner, master, or person in charge to require and have performed at least once in every twelve months the tests and inspections of all hand portable fire extinguishers, semiportable fire extinguishing systems, and fixed fire extinguishing systems on board. 46 CFR 78.17-80(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 20 January 2022 Resolved
Each davit, winch, fall, and other launching appliance must be thoroughly inspected and repaired, as needed, once each year. The #2 rescue boat launching device did not have updated yearly inspection documentation, please provide. 46 CFR 199.190(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2022 Resolved
All doors, except those that are kept normally closed, shall be of a type which are capable of release from the control station and from a position at the door. Local release of the FSD-19 missing a part, making manual release of the FSD difficult. Repair as necessary. 46 CFR 72.05-25(b)(9)(ii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 January 2022 Resolved
The lifejackets stowage positions must be marked with the words “LIFEJACKETS” or “CHILD LIFEJACKETS” as appropriate. There were a few missing lifejacket placards throughout the vessel on the bench stowage locations. Please correct as necessary. 46 CFR 199.170(b)(2)(iii)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 25 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 January 2022 Resolved
The in-port generator was OOC during the inspection. Prove the proper operation of the in-port via all applicable PSTPs to include CO2 system shutdown and power management systems prior to placing the generator back in service.
Action required: 705 - Other - as specified
Resolved 15 March 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 January 2022 Resolved
Mark the direction of operation of each watertight door level or wheel on both sides of the watertight door.
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2022 Resolved
Mark the direction of operation of each watertight door level or wheel on both sides of the watertight door.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2022 Resolved
Repair the ground on the T420 electrical panel. Repair the No. 2 excitation fan for the No.1 drive motor.
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 January 2022 Resolved
Repair the motor operator on the E-Bus tie breaker. Manually charge after each use and verify charge status prior to putting the vessel in service each morning.
Action required: 705 - Other - as specified
Resolved 14 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2022 Resolved
Prove that the No.3 prop alternator can be connected using the No.1 tie breaker.
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 January 2022 Resolved
Repair the No. 2 excitation fan for the No.1 drive motor.
Action required: 10 - Deficiency Rectified
Resolved 21 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 January 2022 Resolved
Prove that the F/O instrumentation for the No. 3 & 4 prop alternator accurately displays the F/O pressure between the analog gauges and the AMS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2022
Resolved 21 November 2022
Resolution: Verified that analog F/O gauges match digital AMS readouts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 April 2021 Resolved
Vessel experienced a crank case explosion on the #3 main engine and experienced a subsequent fire on the #2 end and had to be towed to Eagle Harbor. A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2021
Resolved 15 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 February 2021 Resolved
The electrical characteristics of each overcurrent protective device must be considered in the design of the entire protective system. Fire/bilge pump breaker has a 250 amp breaker installed, drawing lists a 200 amp breaker. Resolve descripancy. Replace with a correctly rated breaker
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 March 2021
Resolved 2 July 2021
Resolution: Breaker replaced with proper size.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 February 2021 Resolved
The General alarm J-boxes on the #2 end sundeck under the piolot house and on the passender deck, #1 end are wated and not watertight. Repair to original condition. Additionally, one more J-box on the passenger deck, for 03 total. 46CFR111.01-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2021
Resolved 22 November 2022
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 October 2019 Resolved
Vessel has fixed fire suppression system installed in the galley range hood which was required for cooking appliances no longer installed in the galley. System was last serviced in January of 2018 and requires servicing every 12 months. Additionally, cylinder gauge is beginning to read in the red unsatisfactory zone. Fire systems installed but not required must be maintained in operational condition. System must either be serviced or removed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2019
Resolved 27 March 2020
Resolution: Vessel rep verified removal via photos.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 August 2019 Resolved
If transformers are used to supply the ship's service distribution system there must be at least two installed, independent power transformers. The HT2 transformer for the ships service bus is not operational
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 28 August 2019
Resolution: Found and repaired a failed wire between the HT2 transformer and the contactor.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 2 July 2019 Resolved
46 CFR 71.55-1 / 50c - Wide areas of pitting corrosion were discovered at various areas on the car deck and upper passenger deck. A full gauging survey which shows the extent and depth of pitting on the car and passenger decks, including both the centerline and wing tunnels, must be completed and submitted to this office within 60 days. The pitted areas must be inspected for cracking or structural deformation once a week and the results of this inspection must be sent to this office. A repair plan must be submitted to address any plate which is pitted by more than a quarter of its original thickness. Any welding proposed as part of the repair plan must be conducted by qualified welders using an approved procedure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 19 March 2020
Resolution: Extended due date to 12/31/19, see narrative for more detail. [name withheld] and [name withheld] accepted temporary repair proposal with permanent repairs to be completed prior to the end of 2019.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 April 2019 Resolved
Sprinkler pipe in zone 4 at bulkhead of vehicle deck has hole requiring replacement of pipe section.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2019
Resolved 16 July 2019
Resolution: MIs confirmed that pipe was renewed. Conducted visual inspection weld. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 April 2019 Resolved
Panelboard directories in pilothouse missing descriptions of some loads and circuit designations. All were missing rating of overcurrent devices on directories. Update all pilothouse panelboards to include complete directory information.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2019
Resolved 10 May 2019
Resolution: Panelboards relabeled and photos emailed to MI from WSF.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 18 April 2019 Resolved
Vehicles were parked blocking fire hose stations and passenger egress aisle spaces. Vehicles to be parked in accordance with loading policy and and painted lines. Discussed with 2nd Mate and Master, who will inspect closer in the future.
Action required: 10 - Deficiency Rectified
Resolved 19 April 2019
Resolution: Deck personnel counseled.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Lashing material
Issued 18 April 2019 Resolved
Vehicles at ends of ferry not properly chocked as required. 2nd Mate counseled and corrected on spot.
Action required: 10 - Deficiency Rectified
Resolved 19 April 2019
Resolution: Deck crew counseled and corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 18 April 2019 Resolved
Galley reefer deck plate welds and rivets broken, creating trip hazard for galley staff. Fasten deck to remove hazard.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 2 May 2019
Resolution: Loose deck in reefer was fastened down and no longer loose with rivets
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2019 Resolved
Galley dry stores wall outlet GP204-13-B duct-taped over. Repair or renew to ensure no electrical hazard present.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 2 May 2019
Resolution: Electrical outlet tape removed and dry stores outlet inspected, found to be operating properly without hazard
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 April 2019 Resolved
Self-closing door to passenger lounge on sun-deck weatherdeck not closing on its own. Adjust or renew to make self-closing in accordance with fire and life-saving plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 2 May 2019
Resolution: Weatherdeck door that was not shutting properly was adjusted by Eagle Harbor personnel and is once again self-closing
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 December 2018 Resolved
Steering system reported by ship's crew as not working properly. Make necessary repairs to steering system and prove proper operation prior to carrying passengers. (46 CFR 58.25)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2018
Resolution: Witnessed proper operation of steering system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2018 Resolved
03 fire hoses burst under pressure. Replaced 03 hoses on scene; all sat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2018
Resolved 15 November 2018
Resolution: Replaced 03 hoses on scene; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 July 2018 Resolved
While on board, found in the Watch Handover Notes the following entry: "#1 Rescue Boat Davit "Limit Switch" valve not working." Crew did not follow SMS procedure for documenting a non-comformity nor was USCG notified of this issue. No work order/requisition was made for this non-conformity. No resolution was identified on board. Master ([name withheld]) indicated that the vessel would be issued a non-conformity. Vessel is not in compliance with the SMS. Conduct an audit of the vessel's SMS and submit findings to the USCG.
Action required: 705 - Other - as specified
Due 10 August 2018
Resolved 24 April 2019
Resolution: Received documentation from WSF indicating that an internal SMS audit was conducted. Cleared CG-835.
Fire Fighting › Fire Hoses › Condition
Issued 17 January 2018 Resolved
Fire Station # 19, 22 and 40 had leaking hoses. Cut in front of inspector and replace with new. 46 CFR 76.10-10
Action required: 10 - Deficiency Rectified
Due 17 January 2018
Resolved 17 January 2018
Fire Fighting › Nozzles › Condition
Issued 17 January 2018 Resolved
Fire Station # 13 and 20 nozzles failed inspection. Replaced with new. 46 CFR 76.10-10(j)
Action required: 10 - Deficiency Rectified
Due 17 January 2018
Resolved 17 January 2018
Fire Fighting › Fire Hydrants › Condition
Issued 17 January 2018 Resolved
Fire Station # 33 had a leaking stem valve. Pipe shop repaired. 46 CFR 76.10-10
Action required: 10 - Deficiency Rectified
Due 17 January 2018
Resolved 17 January 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 January 2018 Resolved
Masthead and Port light alarm on No 1 End Panel did not work. Electrician corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 17 July 2018
Resolved 17 January 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 July 2017 Resolved
CHECK ALL BATTERIES IN LIFE-RING LIGHTS, REPLACE AS NECESSARY.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Resolution: All betteries checked, expired batteries removed from vessel
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2017 Resolved
PROPERLY TERMINATE OR REMOVE DEAD END WIRE IN GALLEY
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 26 July 2017 Resolved
REPAIR OR REPLACE FIRE EXTINGUISHER #54A PLEXY GLASS.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 August 2017
Resolved 2 August 2017
Communications › Internal Communications System › Engine Order Telegraph System
Issued 5 January 2017 Resolved
Engine order telegraph on the # 2 end does not have an audible alarm when the order and answer arrows do not match.
Action required: 705 - Other - as specified
Due 5 February 2017
Resolved 27 February 2017
Engineering › Electric Propulsion System › Circuit Board
Issued 6 October 2016 Resolved
Make perminant proper repairs to SIMADYN D system on #1 end and test prior to opperations with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2016
Resolution: Replaced faulty communications link circut card was replaced by tech rep. Test was sat in the presence of Attending Marine Inspector.
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 6 October 2016 Resolved
Safety trip controls at ECC and both pilot house locations are not independant and must be seperate from systems that they protect. Make controls independant to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 31 July 2025
Resolution: Remote propulsion cantrol system replaced during hybridization project summer of 2026. Non compliant configuaration removed.
Construction/Loadline › Hull › Hull Plating
Issued 4 July 2016 Resolved
Vsl has inset in #2 End starboard bow rub rail. Deck plate, overhanging plate, and longitudinal stiffener in steering gear room are buckled 3-4 inches. Repair no later than next drydock in July 2018.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 July 2018
Resolved 20 January 2017
Resolution: Damaged area cropped and renewed to original scantling.
Lifesaving › Launching Appliances › Davit
Issued 5 April 2016 Resolved
Launch #2 rescue boat at the #1 end. Vessel unable to launch at COI due to obstruction of pier.
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 11 April 2016
Resolution: Boat successfully launched and recovered.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 April 2016 Resolved
02 Emergency lights did not operate and must be replaced.
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 8 April 2016
Resolution: Lights replaced and operational.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 August 2015 Resolved
Prove proper operation of the #3 MDE alternator circuit breaker.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 September 2015
Resolved 23 September 2015
Resolution: Replaced & tested CB, All sat.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 10 August 2015 Resolved
Properly repair Fire Screen Door #22. Door does not fully shut from localor remote release. Provide AB to stand by FSD #22 to ensure closure in the event of a fire. Repair FSD #22 toensure door closes from local and remote operation IAW 46 CFR 72.05-25.
Action required: 705 - Other - as specified
Resolved 10 August 2015
Resolution: Door repaired on site.
Fire Fighting › Fire Main › Valves
Issued 10 August 2015 Resolved
Repair or replace Fire Main valve located at fire fighting station #40 (leak found at head of valve) IAW 46 CFR 76.10-10
Action required: 705 - Other - as specified
Due 15 August 2015
Resolved 19 August 2015
Resolution: Replaced valve at station #40, fire main charged and valve exercised, all sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 August 2015 Resolved
Emergency lighting located on the passenger deck needs to have new light bulbs installed. Numerous E-lights found to be inoperable. Install new light bulbs and ensure all emergency lighting is operational IAW 46 CFR 112.43.
Action required: 705 - Other - as specified
Due 15 August 2015
Resolved 19 August 2015
Resolution: Visually inspected all emergency lighting, all sat.
Engineering › Lubricating Oil Service System › Pump
Issued 23 July 2015 Resolved
Prove proper operation of #3 main engine lube oil system.
Action required: 705 - Other - as specified
Due 31 July 2015
Resolved 29 July 2015
Resolution: Replaced pump, tested system, all sat.
Fire Fighting › Fire Main › Valves
Issued 22 October 2014 Resolved
Prove proper operation of remote actuation for main valve to car deck sprinkler system to the satisfaction of the attending Marine Inspector. Provide proper strainer to car deck sprinkler system to the satisfaction of attending Marine Inspector.
Action required: 705 - Other - as specified
Due 29 October 2014
Resolved 12 November 2014
Resolution: Received notification from Port Engineer that the remote actuator and the Y-Gate strainer were replaced and operating properly.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 26 January 2012 Resolved
Provide copy of Navigation Rules for the #1 pilothouse.
Due 7 February 2012
Resolved 27 January 2012
Resolution: Received notification from vessel representative that the Navigation Rules had been acquired and delivered to the #1 pilothouse.
Fire Fighting › Fire Main › Valves
Issued 26 January 2012 Resolved
Repair/replace valve at firestation #41.
Action required: 705 - Other - as specified
Resolved 27 January 2012
Resolution: Attended vessel and verified that the valve at firestation #41 has been satisfactorily replaced.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 26 January 2012 Resolved
Prove operation of emergenct light EP211-06-B.
Due 29 February 2012
Resolved 27 January 2012
Resolution: Verified that the emergency light was operational. Ballast was replaced. All sat.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 26 January 2012 Resolved
Repair broken switch for manual release of fire screen door #19.
Due 29 February 2012
Resolved 27 January 2012
Resolution: Verified that the manual release switch for fire screen door #19 had been satisfactorily replaced.
Construction/Loadline › Structures › Door
Issued 26 January 2012 Resolved
Prove operation for local alarm for watertight door #19 in the engine space.
Due 29 February 2012
Resolved 27 January 2012
Resolution: Verified operation of watertight door #19 local alarm. Relay was replaced. All sat.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 January 2011 Resolved
Replace damaged PFD.
Action required: 705 - Other - as specified
Due 19 January 2011
Resolved 19 January 2011
Resolution: Shipyard provided extra PFD for vessel prior to inspector departure.
Stability › Watertight Integrity › General
Issued 25 October 2010 Resolved
6 inch gate valves IWO propulsion generator are worn on the No1 and No2 end. Repair/replace valves to original IAW 46 CFR 56.20.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 18 January 2011
Fire Fighting › Fire Hoses › Condition
Issued 21 January 2010 Resolved
During test of fire hoses (to available fire main pressure) two burst beyond repair and were replaced with new ones, sat.
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 21 January 2010
Fire Fighting › Fire Hydrants › Number
Issued 21 January 2010 Resolved
Found valve stem leaks in way of #'s 19, 31 & 40 Fire Stations. Crew Renewed packing, all appeared sat after retest.
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 21 January 2010
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 January 2010 Resolved
Rejected 19 adult PFDs damage by rat infestation. All were replaced with new ones, sat.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 21 January 2010
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 21 January 2010 Resolved
Vessel had an ongoing rat infestation and has to be eradicated complete due to sanitation and damage done to PFDs. Vessel to provide acceptable procedure to complete control/eradicate rat infestation.
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 January 2010
Resolution: Vessel had cleaned/sanitized PFD stowage affected by the infestation, mapped & numbered trap emplacement, and a monthly check will be conducted by WSF contracted pest exterminator (Paratex).
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 21 January 2010 Resolved
Remove/eradicate molds in way of reefer unit,
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2010
Resolved 22 January 2010
Resolution: Reefer unit cleaned and sanitized of molds, sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 15 January 2009 Resolved
Three 30 second time delays for the fixed CO2 system activated too early. Each of the time delays in the engineering paint locker and the emergency generator space activated at 25 seconds and the time delay in the top side paint locker activated at 20 seconds. Vessel required to replace all three time delays.
Action required: 705 - Other - as specified
Due 23 January 2009
Resolved 24 January 2009
Resolution: Replaced the 3 time delays.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Foam Source
Issued 15 January 2009 Resolved
Foam forming solution for the kitchen extinguishing system missing. System did not work. Deep fat fryer has been removed from the vessel and the hot plate is locked/tagged out. Vessel is required to have system operational prior to operating hot plate or upon reinstalling the deep fat fryer.
Due 15 January 2010
Resolved 22 June 2010
Resolution: Vessel operator has no intention of reinstalling the hot plate or deep fat fryer. Moved this 835 in to the Special Notes section.
Construction/Loadline › Hull › Transverse Frame
Issued 24 February 2008 Resolved
Make proper repair of found fracture center transverse web frame in way of #1end frame 76 & 77; and, in way of #2 end frame 76 & 77.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 July 2008
Engineering › Steering Gear System › Pump
Issued 17 January 2008 Resolved
Prove proper operation of #2 end follow up. Speed to slow lock to lock.
Due 18 January 2008
Resolved 18 January 2008
Resolution: Tech rep adjusted pump output. Tast sat.
Fire Fighting › Fire Main › Condition
Issued 17 January 2008 Resolved
Repair leaking flange on fire main piping #2 eng room.
Condition: Unknown
Due 18 January 2008
Resolved 18 January 2008
Resolution: Tightened flangs bolts, test sat.
Fire Fighting › Fire Main › Valves
Issued 17 January 2008 Resolved
Repair leaking fire plug valve station #11.
Condition: Unknown
Due 18 January 2008
Resolved 17 January 2008
Resolution: Replaced valve, test sat.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 17 January 2008 Resolved
prove proper operation of emergency escape handle in freezer.
Due 17 January 2008
Resolved 17 January 2008
Communications › Alarms/Indicators › General Alarm
Issued 17 January 2008 Resolved
Prove proper operation of #1 pilot house general alarm.
Due 17 January 2008
Resolved 17 January 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 January 2008 Resolved
Prove proper operation of FSD #9.
Due 17 January 2008
Resolved 17 January 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 January 2008 Resolved
Replace inoperable lifebuoy lights.
Due 17 January 2008
Resolved 17 January 2008
Fire Fighting › Fire Main › Valves
Issued 17 January 2008 Resolved
Renew leaking fire main valves at fire stations 20, 21, 22, and 23.
Due 17 January 2008
Resolved 17 January 2008
Communications › Audible Communications › Horn/Whistle
Issued 17 January 2008 Resolved
Prove proper operation of manual pull horn in #2 pilot house.
Due 17 January 2008
Resolved 17 January 2008
Electrical › Electric Supply System (service) › Battery Charger
Issued 23 October 2007 Resolved
Vsl experienced battery charger failure/alarm iwo # 1 end propulsion. Crew found burned out card for the the battery charger. Required vsl to make proper repair.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 24 October 2007
Resolution: Vsl changed burned out card and tested system satisfactorily.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 January 2007 Resolved
# 2 end pilot house (port side facing fwd) had lifebouy light that did not ignite.
Due 16 January 2007
Resolved 16 January 2007
Resolution: Corrected on the spot
Fire Fighting › Fire Hoses › Condition
Issued 16 January 2007 Resolved
Fire hose attached to FS # 40 on Texas Deck bursted during presuure test.
Action required: 705 - Other - as specified
Due 16 January 2007
Resolved 16 January 2007
Resolution: Corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 January 2007 Resolved
FD #21 & #23 did not self close during PH test.
Action required: 705 - Other - as specified
Due 16 January 2007
Resolved 16 January 2007
Resolution: Corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Special Category Spaces
Issued 16 January 2007 Resolved
Fire dampers in paint locker were rusted & would not close during test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2007
Resolved 16 January 2007
Resolution: Corrected on the spot.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 27 September 2006 Resolved
Renew hydrostatic releases for all MES's on the car deck prior to operations on 28SEP06.
Due 28 September 2006
Resolved 27 September 2006
Fire Fighting › Structural - Horizontal Zones › General
Issued 17 April 2006 Resolved
Fire Screen Door #10 does not close properly.
Due 17 April 2006
Resolved 17 April 2006
Resolution: Door hinge was adjusted and closes properly upon release.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 17 April 2006 Resolved
Hydrostatic release on #2 emergency station does not have expiration date labelled.
Due 17 April 2006
Resolved 17 April 2006
Resolution: Service records confirmed expiration date, hydrostatic release properly labelled.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 28 February 2005 Resolved
Make permanent repair to the vessel's PLC (ventilation controlling system) operating software. Vessel's fire dampers for the passenger deck area failed to operate properly when activated to close during an actual reported fire in way of sundeck smoke/trash can.
Action required: 705 - Other - as specified
Due 28 April 2005
Resolved 4 April 2005
Resolution: Tested system with sat result.
Engineering › Steering Gear System
Issued 30 May 2002 Resolved
Make permanent repairs to #2 Rudder assembly at next drydocking. LEGACY COMPONENT DESC: Rudder Stock
Condition: Unknown
Due 31 May 2003
Resolved 4 March 2003
Resolution: Vsl renewed bad pintle; and, clad weld and resurface rudder (IWO # 2 end). Vsl conducted sea trial, operational test of the # 2 end rudder appeared sat.
Fire Fighting › Structural - A Class Divisions
Issued 27 March 2002 Resolved
Two small sections of insulation removed around escape scuttle from CO2 room. Replace insulation. LEGACY COMPONENT DESC: Decks - Service Spaces
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 3 September 2002
Resolution: SIGHTED SAT.
Fire Fighting › Structural - A Class Divisions
Issued 27 March 2002 Resolved
Transverse overhead longitudinals outboard of boilers missing insulation removed for chains falls. Replace insulation. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 3 September 2002
Resolution: SIGHTED SAT.
Fire Fighting › Structural - A Class Divisions
Issued 27 March 2002 Resolved
Vertical drain pipe deck penetration in overhead above boiler missing required insulation. Insulate in accordance with applicable regulations. LEGACY COMPONENT DESC: Decks - Machinery Spaces
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 3 September 2002
Resolution: SUGHTED SAT.
Engineering › Freshwater System (intermediary cooling)
Issued 27 March 2002 Resolved
#2 end thyristor cooling system, cooling water out expansion joint cracked. Renew. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 3 September 2002
Resolution: SIGHTED SAT.
Accommodation/Occupational Safety › Occupational Safety
Issued 27 March 2002 Resolved
Numerous water tight door deck plate thresholds not operating properly; hindering personnel movement along egress routes. Modify deck plates to prevent threshold plates from becoming stuck in the open position.
Action required: 705 - Other - as specified
Due 27 April 2002
Resolved 3 September 2002
Resolution: SIGHTED SAT (ALL).
Engineering
Issued 6 July 2000 Resolved
DURING NORMAL OPERATIONS, NO.2 END SHAFT SPEED NOT TO EXCEED 140 RPM.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Construction/Loadline
Issued 6 July 2000 Resolved
NO. 2 END WT DOORS AT FRAMES 30, 42, AND 60 TO REMAIN CLOSED.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Electrical
Issued 23 February 1999 Resolved
PERMANENTLY INSTALL BENCH GRINDER INTO ELECTRICAL SYSTEM.
Condition: Unknown
Due 23 February 1999
Resolved 23 February 1999
Lifesaving
Issued 23 February 1999 Resolved
PLACE A SIGN DECLARING "WHILE PERSONNEL ARE INSIDE, DOOR IS TO REMAIN OPEN"ON THE INPORT GENERATOR ROOM DOOR.
Condition: Unknown
Due 23 February 1999
Resolved 23 February 1999
Lifesaving
Issued 23 February 1999 Resolved
INSTALL THE LATCH ON THE DOOR TO THE CO2 ROOM.
Condition: Unknown
Due 23 February 1999
Resolved 23 February 1999
Lifesaving
Issued 23 February 1999 Resolved
REMOVE LOCK ON DOOR TO THE CO2 ROOM.
Condition: Unknown
Due 23 February 1999
Resolved 23 February 1999
Construction/Loadline
Issued 19 August 1998 Resolved
REPLACE SHATTERED BRIDGE GLASS ON THE PORT SIDE OF THE #2 PILOT HOUSE.
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Fire Fighting
Issued 22 May 1998 Resolved
INSTALL A 15LB CO2 EXTINGUISHER AT STATION 11A (EOS).
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Accommodation/Occupational Safety
Issued 22 May 1998 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS INSTALL COURSES OR PANELS IN STAIRTOWERHANDRAILS.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Lifesaving
Issued 22 May 1998 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS CONDUCT A FIRE AND BOAT DRILL.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Engineering
Issued 22 May 1998 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS PROVIDE A COPY OF THE ENGINEERING LOG MAINTAINED DURING CREW TRAINING PERIOD.
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Documentation
Issued 22 May 1998 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS PROVIDE A COPY OF A STABILITY LETTER WHICH PERMITS THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998

Casualty record · 29

20 August 2001Routine · role: Involved in a Marine Casualty · 2 injured · activity 76171
22 May 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1622106
27 January 2004Routine · role: Involved in a Marine Casualty · activity 1996046
31 January 2008Routine · role: Involved in a Marine Casualty · activity 3140230
22 October 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3350961
22 May 2009Routine · role: Transiting Vicinity of Primary Subject · activity 3482183
30 August 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3581392
8 February 2010Routine · role: Involved in a Marine Casualty · activity 3707420
30 May 2010Routine · role: Involved in a Marine Casualty · 1 injured · activity 3756010
9 June 2010Routine · role: Involved in a Marine Casualty · activity 3767388
10 June 2010Routine · role: Involved in a Marine Casualty · activity 3767493
21 May 2011Routine · role: Involved in a Marine Casualty · activity 4020182
22 August 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4433851
6 December 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4512016
5 January 2014Routine · role: Involved in a Marine Casualty · activity 4778077
9 February 2014Routine · role: Involved in a Marine Casualty · activity 4798008
3 May 2014Routine · role: Involved in a Marine Casualty · activity 4851229
12 April 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5865692
4 July 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6014624
6 October 2016Routine · role: Involved in a Marine Casualty · activity 6020325
7 March 2018Routine · role: Involved in a Marine Casualty · 1 injured · activity 6370553
2 November 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6573791
20 November 2018Routine · role: Involved in a Marine Casualty · 1 injured · activity 6588722
29 May 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6702608
2 August 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6778194
7 October 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6830741
22 April 2021Major Marine Casualty · role: Subject of Search and Rescue · serious marine incident, as classified · activity 7181119
27 August 2025Routine · role: Involved in a Marine Casualty · activity 8258334
29 October 2025Routine · role: Involved in a Marine Casualty · activity 8261212
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.