MAURY USCG vessel records Sign in
← All vessels

CAPE FEAR

CAPE FEAR is a 1971 freight ship. The Coast Guard has recorded 89 inspections since 1985, most recently in February 2007, along with 161 deficiencies — 8 with no resolution recorded —.

Records from 1985 to 2007. Most recent: inspection, 5 February 2007.

Built
1971
Last inspected
5 February 2007
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7050248 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-46791

Inspections, by type

…with no type recorded25
…past their stated due date1
Years with a record 22 calendar years (1985–2007)
The 89 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)738.5 ft × 100.2 ft × 55.5 ft
Registered tonnagegross 26,406 / net 18,706
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAVONDALE SHIPYARDS, INC · AVONDALE, LA, UNITED STATES · built 1971
Hull materialSteel
PropulsionSteam Turbine
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29820 - Dead Weight, Ton
44606 - Displacement, Ton
26406 - Regulatory (Subpart C or D), Gross Ton
18706 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WEZAMMSI not assigned · expired · compulsorily equipped · granted 18 July 1991, cancelled 18 July 1996 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPE MOHICAN Freight Ship · MISLE 47052 · 6 June 2006 · activity 2672411

Inspection history · 89

5 February 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2867328
7 August 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2738702
6 June 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2672411
26 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2633860
6 February 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2580331
27 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2574503
9 December 2005 Liferaft Servicing
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2548818
17 October 2005 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2516192
11 August 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2459275
13 July 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2425384
8 July 2005 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2419487
20 May 2005 Deficiency Check · In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2363257
11 May 2005 MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2339199
28 March 2005 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2321432
19 January 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2277371
13 January 2005 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2274295
2 December 2004 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2252165
20 September 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2196945
27 July 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2153955
3 June 2004 MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2087447
24 May 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2076898
28 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995590
26 January 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1983376
18 December 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1966666
3 September 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1849478
24 February 2003 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1748983
22 January 2003 Hull Examination · Internal Structural Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1724608
5 December 2002 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1718531
27 November 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1711609
9 October 2002 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1687214
5 July 2002 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1641635
20 November 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1076744
30 August 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1071212
31 July 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1069845
27 October 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1054999
28 September 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1054309
6 September 2000 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1059219
19 September 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 77958
18 September 1998 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1404621
3 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 783977
12 December 1997 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1364579
28 January 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1100753
15 January 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1099750
7 January 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1097436
6 January 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096051
26 December 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1091662
3 December 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 876089
27 August 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1090295
22 July 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1091908
25 August 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 880592
11 August 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1355403
7 March 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1168917
20 December 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 871532
13 November 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 67208
7 October 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866566
1 October 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1426960
1 September 1994 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1172204
23 March 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1373813
27 February 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 55132
26 February 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 141769
23 February 1993 Examination of Repairs · Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407101
13 January 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1137968
30 October 1992 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 932510
12 August 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 932402
22 June 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 164018
19 February 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 946562
16 February 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 456851
30 January 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006744
25 November 1991 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1471068
9 August 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1245966
11 June 1991 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 941782
11 June 1991 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1336958
18 December 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1217101
13 December 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1239153
9 December 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 480205
15 October 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 915932
3 October 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219645
28 September 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 924430
25 September 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1229885
5 September 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 913415
18 August 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1220484
18 July 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 912979
21 June 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1241067
21 June 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1043121
13 June 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 893127
10 June 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1200844
2 June 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1336172
16 April 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 998521
29 March 1985 Credit Drydock · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1299836

Deficiency record · 161

Lifesaving › Launching Appliances › Falls
Issued 6 February 2006 No resolution recorded
Perform weight test for both port and starboard davit wires prior to departure from port.
Action required: 705 - Other - as specified
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 11 August 2005 No resolution recorded
Demonstrate proper operation of both reverse power relays.
Action required: 705 - Other - as specified
Due 6 October 2005 — due date passed with no resolution recorded
Resolution: Proper operation was witnessed by ABS.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 11 August 2005 Resolved
Repair and prove proper operation of lube oil low pressure alarm at engineering console for ship's service diesel generator.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Documentation › Certificates/Documents › IOPP Certificate
Issued 11 August 2005 No resolution recorded
Perform IOPP survey prior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 11 August 2005 Resolved
Update emergency contact information in SOPEP. Sector San Francisco emergency number is no longer correct.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Communications › Radio Communications › Emergency Source of Power
Issued 11 August 2005 Resolved
Repair as new and show proper operation of GMDSS UPS system.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 August 2005 Resolved
Renew one (1) adult PFD.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 August 2005 Resolved
Recharge one (1) B-II fire extinguisher in aft DC locker.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 11 August 2005 Resolved
Provide service report for topside portable paint locker fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Stability › Watertight Integrity › Weathertight Enclosure
Issued 11 August 2005 Resolved
Repair as new vent closure in way of stbd side aft trunkway.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 11 August 2005 Resolved
Repair as new fire damper in way of stbd side just aft of fire station #5.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 August 2005 Resolved
Remove and renew all expired meds in hospital and in lifeboat first aid kits.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 11 August 2005 No resolution recorded
Submit approved plans for installation of new refer units adjacent to galley.
Action required: 705 - Other - as specified
Navigation › Piloting/Steering › Marine Charts
Issued 11 August 2005 No resolution recorded
Provide complete set of nautical charts and publications pior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Navigation › Piloting/Steering › Gyro Compass
Issued 11 August 2005 No resolution recorded
Show proper operation of all electronic equipment and gyro prior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 August 2005 No resolution recorded
Complete fire and lifeboat drills including operational test of both lifeboats prior to activation.
Action required: 17 - Rectify deficiencies prior to departure
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 11 August 2005 Resolved
Post ship identification number as required by SOLAS 74/78.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 11 August 2005 Resolved
Show proof vessel is in compliance with ISM Code with updated Safety Management Certificate.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Lifesaving › Launching Appliances › Falls
Issued 11 August 2005 Resolved
End for end lifeboat falls as required by 46 CFR 199.190(j).
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Resolution: New wires installed on both port and starboard falls.
Engineering › Pressure Vessel › Piping
Issued 28 March 2005 Resolved
Repair as new main steam stop drain in way of faulty weld. This weld failed after valve and before steam trap.
Action required: 705 - Other - as specified
Due 29 May 2005
Resolved 17 May 2005
Engineering › Steam Boiler (propulsion) › Automation Equipment
Issued 28 March 2005 No resolution recorded
Submit plans for the installation of new console guage board in engineroom.
Action required: 705 - Other - as specified
Engineering › Steam Boiler (propulsion) › Piping
Issued 2 December 2004 Resolved
Conduct hydrostatic test of the waterside and inspect the fireside of Starboard main propulsion boiler in the presence of a marine inspector.
Due 31 January 2005
Resolved 17 May 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 2 December 2004 Resolved
Update ships plans to reflect wing ballast tanks that have been converted to fuel tanks.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 6 February 2006
Engineering › Bilge Water Management System › Piping
Issued 2 December 2004 Resolved
Provide plans, qualified weld procedures and welder certs for newly installed wilden pump and piping in main engine room.
Action required: 705 - Other - as specified
Due 31 January 2005
Resolved 19 January 2005
Deck/Cargo › Ballast › Piping
Issued 2 December 2004 Resolved
Provide plans, qualified weld procedures and welder certs for newly installed ballast pump and piping in main engine room.
Action required: 705 - Other - as specified
Due 31 January 2005
Resolved 19 January 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 2 December 2004 Resolved
Provide qualified weld procedures for replacement plating in forward salt water ballast tanks.
Action required: 705 - Other - as specified
Due 31 January 2005
Resolved 19 January 2005
Engineering › Steam Boiler (propulsion) › Piping
Issued 2 December 2004 Resolved
Provide QWP,welder certification and plans on both newly installed main boiler drains.
Action required: 705 - Other - as specified
Due 17 January 2005
Resolved 27 January 2005
Engineering › Steam Boiler (propulsion) › Piping
Issued 2 December 2004 Resolved
Add additional weld pass to port boiler superheater drain line using approved welders & procedures, then complete X-ray of weld followed up with a hydrostatic test of boiler to 1.5 MAWP
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 21 January 2005
Engineering › Steam Boiler (propulsion) › Piping
Issued 2 December 2004 Resolved
In -lieu of requirement # 8 remove spool piece on superheater line and renew using approved materials, welders, and weld procedures in the presence of an attending marine inspector. Then complete hydrostatic test of boiler to 1.25 MAWP.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 27 January 2005
Engineering › Steam Boiler (propulsion) › Piping
Issued 2 December 2004 Resolved
Complete x-ray and conduct hydrostatic test of starboard boiler to 1.5 MAWP or complete requirement 9 on starboard boiler.
Action required: 705 - Other - as specified
Due 11 February 2005
Resolved 21 January 2005
Resolution: X-ray sat.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 27 July 2004 Resolved
Provide current charts and pubs prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 20 September 2004
Lifesaving › Buoyant Smoke Signals › General
Issued 27 July 2004 Resolved
Provide pyrotechnics for bridge life rings.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Navigation › Piloting/Steering › Gyro Compass
Issued 27 July 2004 Resolved
Show proper operation of bridge equipment prior to sailing
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 20 September 2004
Communications › Radio Communications › Satellite Communications Capability
Issued 27 July 2004 Resolved
Provide shoreside maintenance certificate for radio equipment.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 July 2004 Resolved
Repair starboard running light.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 20 September 2004
Lifesaving › Lifeboat Equipment › Seasickness Bag
Issued 27 July 2004 Resolved
Renew sea sick kits for life boats.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 27 July 2004
Lifesaving › Lifeboat Equipment › Searchlight
Issued 27 July 2004 Resolved
Provide searchlights for life boats.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 20 September 2004
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 July 2004 Resolved
Prove proper operation of bridge stairwell fire door.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 July 2004 Resolved
Prove proper operation of galley deck midships vestibule door.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 July 2004 Resolved
Repair hand rail for bow look out position.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Fire Fighting › Fire Main › Valves
Issued 27 July 2004 Resolved
Repair leaking valve stems on fire stations 14 and 17.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Fire Fighting › Fire Hydrants › Condition
Issued 27 July 2004 Resolved
Repair leaking flange on fire station 20.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Engineering › Steam Boiler (propulsion) › Fuel Oil Burner
Issued 27 July 2004 Resolved
Install flange shielding on fuel oil lines in way of port and starboard boilers.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 27 July 2004 Resolved
Provide copy of annual SOPEP review letter.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 20 September 2004
Operations/Management › Drills/Instruction › Abandon Ship
Issued 27 July 2004 Resolved
Conduct abandon ship drill
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 20 September 2004
Operations/Management › Drills/Instruction › Fire
Issued 27 July 2004 Resolved
Conduct fire drill.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 20 September 2004
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 September 2003 Resolved
Prove operation of OWS system. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 27 July 2004
Engineering › Steam Boiler (propulsion)
Issued 3 September 2003 Resolved
Prove proper operation of stbd steam propulsion boiler's super heater safety valve at next light off or before 4 Dec 03. Which ever comes first. LEGACY COMPONENT DESC: Superheater Protection System
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 30 January 2004
Lifesaving › Inflatable Liferafts
Issued 3 September 2003 Resolved
Provide proof of servicing on all liferafts.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 26 January 2004
Fire Fighting › Miscellaneous Items
Issued 3 September 2003 Resolved
Provide annual servicing for all portable and fixed fire fighting equipment.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 26 January 2004
Lifesaving
Issued 3 September 2003 Resolved
Provide new batteries for SARTS. LEGACY COMPONENT DESC: sarts
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 30 January 2004
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 September 2003 Resolved
Provide proof of annual SOPEP. LEGACY COMPONENT DESC: SOPEP
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 5 August 2004
Resolution: Reissued reqiurement
Documentation › Certificates/Documents
Issued 3 September 2003 Resolved
Provide proof of annual ammendments to all ABS certificates.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 26 January 2004
Communications › Radio Communications › Satellite Communications Capability
Issued 3 September 2003 Resolved
Provide proof of GMDSS operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 5 August 2004
Resolution: Reissued requirement
Operations/Management › Drills/Instruction › Abandon Ship
Issued 3 September 2003 Resolved
Perform fire and lifeboat drills upon activation.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2005
Resolved 5 August 2004
Resolution: reissued requirement
Communications › Internal Communications System › Sound-powered Telephone
Issued 3 September 2003 Resolved
Submit plan to install CAT 5./telephone cable in forward deck house IAW 46CFR92.07-10
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 27 July 2004
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 3 September 2003 Resolved
Remove expired items from lifeboat first aid kits and replace with new.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 27 July 2004
Fire Fighting › Fire Hoses
Issued 3 September 2003 Resolved
Provide proof of annual fire hose test.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 30 January 2004
Lifesaving › Lifeboat › Handholds/Handrails
Issued 3 September 2003 Resolved
Provide monkey lines for all lifeboats.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 27 July 2004
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 3 September 2003 Resolved
Remove portable air conditioners and replace glasing in accomodation spaces.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 July 2005
Resolved 20 September 2004
Communications › Audible Communications › Bell
Issued 3 September 2003 Resolved
Provide clapper for Focsle Bell. LEGACY COMPONENT DESC: Bell
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 27 July 2004
Electrical › Electrical Distribution System (service)
Issued 3 September 2003 Resolved
Replace wiring and stuffing tubes on jackstaff.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 26 January 2004
Electrical › Electrical Distribution System (service)
Issued 3 September 2003 Resolved
Repair light fixtures in hospital space.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 26 January 2004
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 3 September 2003 Resolved
Provide proof of hydrostatic test of oxygen bottle in hospital space. LEGACY COMPONENT DESC: Hospital Space
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2004
Resolved 27 July 2004
Accommodation/Occupational Safety › Ventilation
Issued 31 December 2002 Resolved
Conduct air quality test of upper and lower bos'n stores and determine them "safe for entry" prior to any personel entering theses spaces as required by NFPA 306. This requirement shall remain in effect until the fixed ventilation system has been restored as original.
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 13 May 2003
Resolution: The fixed ventilation system has been restored to it''s original condition.
Construction/Loadline › Penetrations
Issued 31 December 2002 Resolved
Submit proposal to repair main condenser intake scoop.
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 5 February 2003
Construction/Loadline › Hull
Issued 31 December 2002 Resolved
Provide inspection call out for repairs to rudder wrapper sheet on upper rudder horn. LEGACY COMPONENT DESC: Rudder wrapper sheet
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 12 February 2003
Construction/Loadline › Hull
Issued 31 December 2002 Resolved
Provide Non-Destructive testing report on main condenser sea scoop intake. LEGACY COMPONENT DESC: Sea scoop
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 5 February 2003
Construction/Loadline › Penetrations
Issued 31 December 2002 Resolved
Provide manufacturer's specification sheet for main condenser discharge valve. LEGACY COMPONENT DESC: Sea Valve
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 12 February 2003
Construction/Loadline › Penetrations
Issued 31 December 2002 Resolved
Open up for inspection check valve in way of fwd ballast tank. LEGACY COMPONENT DESC: Check Valve
Action required: 705 - Other - as specified
Due 22 February 2003
Resolved 12 February 2003
Engineering › Bilge Water Management System
Issued 31 December 2002 Resolved
Provide Mil-Certification for newly installed ballast piping. LEGACY COMPONENT DESC: Piping
Due 22 February 2003
Resolved 13 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 31 December 2002 Resolved
Provide material specification (analysis) for unknown oil like substance discovered in forward void.
Due 22 February 2003
Resolved 6 February 2003
Fire Fighting › Ventilation Systems
Issued 9 October 2002 Resolved
Mechanical ventilation is inoperable for chain locker and Bos'n store room in bow area; There is a missing blower; Provide mechanical ventilation to these spaces prior to activation.
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 13 May 2003
Engineering › Steam Boiler (propulsion) › Superheater Tube
Issued 5 July 2002 Resolved
Re-weld super heater tubes and conduct hydro.
Due 22 July 2002
Resolved 22 July 2002
Documentation
Issued 31 July 2001 Resolved
Conduct Inspection for Certification prior to operating vessel, in accordance with the MARAD MOU not later than 31JUL02.
Condition: Unknown
Due 31 July 2002
Resolved 20 August 2002
Resolution: Completed COI.
Fire Fighting
Issued 3 March 1998 Resolved
PROVE PROPER OPERATION OF FIXED CO2 REMOTE SHUTDOWNS OF THE FORCED DRAFT FANS AND PUMPS IN ENGINE ROOM, AND THE FIXED CO2 REMOTE ACTIVATION OF THE WATERTIGHT DOORS IN ENGINE ROOM.
Condition: Unknown
Due 3 March 1998
Resolved 3 March 1998
Documentation
Issued 28 January 1997 Resolved
REVISE AUTOMATION PROCEDURES AND SUBMIT FOR COAST GUARD APPROVAL OR COMPLETE TEST PROCEDURES II.D AND II.L.
Condition: Unknown
Due 28 January 1997
Resolved 28 January 1997
Construction/Loadline
Issued 7 January 1997 Resolved
OVERFLOW PIPE BRACKET - WELD; 1ST WEB FROM FWD- PORT AND STBD GUSSETS IN OVHD - REPAIR; UPPER LONGITUDINALS (PORT AND STBD) AT FWD BULKHEAD - CRACKS- REPAIR; PORT UPPER LONGITUDINAL AT AFT BULKHEAD - CRACK - REPAIR.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Engineering
Issued 26 December 1996 Resolved
ON PORT BOILER, REPAIR PREVIOUSLY PLUGGED TUBE LOCATED FORWARDMOST (IN A BANK OF 4 PLUGGED TUBES) IN THE SUPERHEATER, 1ST ROW BEHIND THE SCREEN TUBES (VISIBLE WITHIN THE FIREBOX).
Condition: Unknown
Due 26 January 1997
Resolved 6 January 1997
Engineering
Issued 26 December 1996 Resolved
ON STBD BOILER, REPLACE PACKING ON LEAKING VALVES (BULKHEAD STOP, GENERATORSTOP, ETC).
Condition: Unknown
Due 26 January 1997
Resolved 6 January 1997
Engineering
Issued 26 December 1996 Resolved
ON STBD BOILER, REPAIR PREVIOUSLY PLUGGED TUBES #18 & #19 FROM FORWARD END OF SECONDARY INBOARD SUPERHEATER HEADER.
Condition: Unknown
Due 26 January 1997
Resolved 6 January 1997
Engineering
Issued 26 December 1996 Resolved
ON STBD BOILER, REPLACE CASTABLE AROUND INBOARD SIDE OF AFT DOOR TO SUPERHEATER VESTIBULE.
Condition: Unknown
Due 26 January 1997
Resolved 6 January 1997
Engineering
Issued 26 December 1996 Resolved
ON PORT BOILER, TIGHTEN IDENTIFIED HANDHOLES ON SUPERHEATER HEADERS (23), FORWARD WALL HEADER (6), INBOARD SIDEWALL HEADER (2), AND ON FORWARD/AFTER UPPER WATERWALL HEADERS.
Condition: Unknown
Due 26 January 1997
Resolved 6 January 1997
Engineering
Issued 26 December 1996 Resolved
TIGHTEN IDENTIFIED HANDHOLES FOR STBD BOILER ON SUPERHEATER HEADERS (29), FORWARD UPPER WALL HEADER (2), FORWARD LOWER WALL HEADER (9), AFTER LOWER WALL HEADER (1), AND SIDEWALL HEADER (6).
Condition: Unknown
Due 26 January 1997
Resolved 6 January 1997
Engineering
Issued 26 December 1996 Resolved
PROVIDE WELDER QUALIFICATION AND WELD PROCEDURES TO SEAL WELD PREVIOUSLY PLUGGED TUBES.
Condition: Unknown
Due 26 January 1997
Resolved 6 January 1997
Engineering
Issued 26 December 1996 Resolved
ON PORT BOILER, REPAIR PREVIOUSLY PLUGGED TUBE #14 FROM FORWARD WALL, INBOARD SUPERHEATER HEADER (VISIBLE WITHIN THE SUPERHEATER VESTIBULE).
Condition: Unknown
Due 26 January 1997
Resolved 6 January 1997
Engineering
Issued 7 October 1994 Resolved
SUBMIT PROPOSAL FOR BENT SUPERHEATER AND WALL TUBES IN STBD BOILER. SUPERHEATER TUBES IWO FWD OUTBOARD CORNER, WALL TUBES IWO INBOARD FWD AND OUTBOARD AFT CORNERS.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Engineering
Issued 7 October 1994 Resolved
REATTACH BRICKWORK TO OUTBOARD WALL ON PORT BOILER.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Lifesaving
Issued 1 October 1994 Resolved
VESSEL IS PROHIBITED FROM MAKING AN INTERNATIONAL VOYAGE UNTIL SUCH TIME THAT HOSPITAL IS EQUIPED WITH MEDICAL SUPPLIES.
Condition: Unknown
Due 1 October 1994
Resolved 1 October 1994
Lifesaving
Issued 1 October 1994 Resolved
END FOR END OR REPLACE BOTH PORT AND STBD LIFEBOAT FALLS.
Condition: Unknown
Due 1 October 1994
Resolved 1 October 1994
Engineering
Issued 23 February 1993 Resolved
BUILD UP SUPERHEATER TUBES INWAYOF DOGBONE CONNECTIONS PER MANUFACTURES STANDARD PROCEDURE, GRIND DOWN, AND NDT. (CLASS PROBLEM ON THIS TYPE OF BABCOCK AND WILCOX BOILER)._x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Accommodation/Occupational Safety
Issued 23 February 1993 Resolved
REMOVE COMBUSTIBLE GEAR AND PORTABLE HEATER OUT OF 02 LEVEL BATTERY LOCKER_x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Electrical
Issued 23 February 1993 Resolved
RELABEL CO2 PRESSURE SWITCHES TO CORRESPOND TO APPROPRIATE MACHINERY SHUT DOWNS (VENTILATION & EMERGENCY GENERATOR TRIP VERSUS WATERTIGHT DOOR CLOSURE)._x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Lifesaving
Issued 23 February 1993 Resolved
RENEW LIGHTS ON PFDS AND EXPOSURE SUITS WITH SOLAS APPROVED LIGHTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Construction/Loadline
Issued 23 February 1993 Resolved
PROVIDE A COPY OF THE UNDERWATER SURVEY PLAN AND LATEST HULL GAUGINGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 February 1993
Resolved 23 February 1993
Construction/Loadline
Issued 23 February 1993 Resolved
RENEW 5 GLOBE SEA VALVES DUE TO STEM WEAR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Navigation
Issued 23 February 1993 Resolved
BUILD UP AND TRUE WORN RUDDER POST BEARING SURFACES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Engineering
Issued 23 February 1993 Resolved
REPAIR BOTTOM FLANGE OF MAIN STEAM STOP VALVE, PORT BOILER. SKIM CUT FLANGESEAT TO REMOVE STEAM CUT (LEAKING)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Navigation
Issued 23 February 1993 Resolved
CROP OUT AND RENEW ERODED PLATE SECTION ON RUDDER TOP, CLAD WELD (BUILD UP)WASHED OUT WELDS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Lifesaving
Issued 23 February 1993 Resolved
PROVIDE OXYGEN CONTENT METERS FOR EMERGENCY GEAR LOCKERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Engineering
Issued 23 February 1993 Resolved
ADJUST PORT BOILER FORWARD DRUM AND DRUM PILOT SAFETIES WITHIN LIFT AND SEAT LIMITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Engineering
Issued 23 February 1993 Resolved
BUILD UP AND MACHINE SUPERHEATER HEADER HANDHOLE OPENINGS AND SEATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Construction/Loadline
Issued 23 February 1993 Resolved
CROP OUT AND RENEW WASTED SECTIONS OF CHAIN LOCKER EDUCTOR PIPING, PROVE OPERATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Construction/Loadline
Issued 23 February 1993 Resolved
FREE UP STUCK BILGE INJECTION VALVE, PROVE OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Engineering
Issued 23 February 1993 Resolved
CROP OUT AND RENEW SECTIONS OF TWO TUBES IN PORT BOILER FIREBOX, PROVIDE APPROVED WPS & WPQ, FITUP AND NDT IN PRESENCE OF INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Lifesaving
Issued 23 February 1993 Resolved
RENEW CONDENSED MILK WITH NEW MILK OR EQUIVALENT PROVISIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Construction/Loadline
Issued 23 February 1993 Resolved
PROVIDE A LIST OF MANUFACTURE DATES OF THE NON-METALLIC FLEXIBLE EXPANSION JOINTS INSTALLED IN THE MACHINERY PIPING SYSTEMS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 February 1993
Resolved 23 February 1993
Construction/Loadline
Issued 23 February 1993 Resolved
ADJUST PORT ENGINEROOM WATERTIGHT DOOR AND SHAFT ALLEY WATERTIGHT DOOR CONTROLS FOR PROPER OPERATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Fire Fighting
Issued 23 February 1993 Resolved
CORRECTLY LABEL (DATE) PORTABLE FIRE EXTINGUISHERS WITH INCORRECT SERVICE DATES (YEAR)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Fire Fighting
Issued 23 February 1993 Resolved
RENEW MECHANICAL SEAL ON MAIN ENGINEROOM FIREPUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Engineering
Issued 23 February 1993 Resolved
RENEW PORT BOILER HI-LOW LEVEL ALARM WIRING, EXISTING WIRING NOT HEAT RESISTANT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Engineering
Issued 23 February 1993 Resolved
PROVE OPERATION OF EOT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 February 1993
Resolved 25 February 1993
Construction/Loadline
Issued 12 August 1992 Resolved
REPAIR WATERTIGHT DOOR AFT END STARBOARD ALLEY.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Deck/Cargo
Issued 11 June 1991 Resolved
FOWARD SECTION OF CRANE RAIL (PORT & STBD) TO BE LIFTED, BED RAIL DESCALED AND TREATED WITH ANTI CORROSIVE PAINT AND RAIL RESET WITH NEW GAGE ALLIGNMENT BOLTS. TO BE COMPLETED PRIOR TO MID PERIOD REINSPECTION AND IN NO CASE LATER THAN 09SEP92.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Engineering
Issued 25 September 1990 Resolved
REPAIR GAGE GLASSES, LOWER SET, PORT MAIN BOILER.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Engineering
Issued 25 September 1990 Resolved
REPAIR INBOARD FEED PUMP REMOTELY OPERATED STEAM SUPPLY VALVE.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Construction/Loadline
Issued 25 September 1990 Resolved
OPEN FOR INSPECTION #3 D.B. S.W. BALLAST TANK. PROVIDE MARINE CHEMIST CERTIFICATE.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Navigation
Issued 25 September 1990 Resolved
CORRECT CHARTS AND PROVIDE REQUIRED PUBLICATIONS FOR NAVIGATION.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Engineering
Issued 25 September 1990 Resolved
[name withheld] TO TEST HP, LP, AND ASTERN OVERSPEEDS AT SEA AND LOG IN MACHINERY LOG.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Engineering
Issued 25 September 1990 Resolved
REPAIR SUPERHEATER SAFETY VALVE ON STB'D MAIN BOILER. VALVE WILL NOT RESEAT PROPERLY.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Electrical
Issued 25 September 1990 Resolved
REPAIR SSTG OVERSPEED TRIP AND TEST IN THE PRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Engineering
Issued 25 September 1990 Resolved
REPAIR ON BOTH FEED PUMPS, THE MANUAL REGULATOR CONTROL MODE SO THAT THE CONSOLE THUMBSCREW WORKS AS THE POINTER INDICATES AND OPERATES IN THE SAME DIRECTION AS THE AUTOMATIC MODE.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Engineering
Issued 25 September 1990 Resolved
REPAIR EYE-HYE INDICATORS FOR BOTH PORT AND STB'D MAIN BOILERS.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Construction/Loadline
Issued 25 September 1990 Resolved
OPEN FOR INSPECTION #1 S.W. BALLAST TANK. PROVIDE MARINE CHEMIST CERTIFICATE.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Construction/Loadline
Issued 25 September 1990 Resolved
OPEN FOR INSPECTION #2 D.B. S.W. BALLAST TANK. PROVIDE MARINE CHEMIST CERTIFICATE.
Condition: Unknown
Due 25 September 1990
Resolved 25 September 1990
Deck/Cargo
Issued 21 June 1990 Resolved
REPLACE ALL MISSING VENT AND CARGO CONTAINMENT PLUGS AND ATTACH WITH CHAIN TO THE CONTAINMENT DEVICES.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990 Resolved
REPLACE MISSING DOGS ON THE CARGO OIL HATCH ON THE PORT SIDE AT FRAME 78, AND REPLACE THE BROKEN PIPING BRACE AT FRAME 78.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990 Resolved
REPLACE THE BREAKERS OR PUT BLANKS IN PANELS 2-88-1 IN THE STARBOARD TUNNELAND 2-99-2 IN THE PORT TUNNEL.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990 Resolved
REPLACE MISSING DOGS ON THE VENT ON THE PORT SIDE FORWARD NEAR THE CRANE, AND ON ALL HATCHES AFT OF THE HOUSE, REPLACE THE GASKET ON THE HATCH TO FORWARD BOSUNS STORES.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990 Resolved
REPAIR THE EXPLOSION PROOF LIGHT FIXTURES IN THE FORWARD BOSUNS LOCKER WHICH ARE APART AND MISSING GLOBES AND OR CAGES, AND THAT HAVE BEEN TAKEN APART AND NOT PROPERLY PUT BACK TOGETHER.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Engineering
Issued 21 June 1990 Resolved
E6 PROVIDE DOCUMENTATION OF TESTING OF A/R RELIEF VALVE ON 02 LEVEL. MAY BE TESTED AT AN OUTSIDE FACILITY.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990 Resolved
E7 OPERATE ENGINE IN MOTOR LIFE BOAT. (ENGINE APPEARS FROZEN)
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990 Resolved
REPAIR/REPLACE THE TOP RUNG OF THE STARBOARD EMBARKATION THAT HAS WASTED AWAY ON ONE SIDE AND IS BADLY WORN ON THE OTHER.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990 Resolved
REPLACE MISSING AND WORN FLAME SCREENS ON ALL OUTSIDE VENTS FOR FUEL AND CARGO TANKS AS NECESSARY.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990 Resolved
REPLACE THE BROKEN LIGHTING FIXTURE IN THE AFTER STEERING SPACE NEAR THE FORWARD BULKHEAD ON THE C/L OF THE VESSEL.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990 Resolved
REPLACE MISSING SPANNER WRENCHES AT VARIOUS FIRE STATIONS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990 Resolved
REPAIR THE CRACKS THROUGH THE GUNNEL ON THE STARBOARD SIDE FORWARD AND TWO CRACKS THROUGH THE GUNNEL ON THE PORT SIDE AFT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Navigation
Issued 21 June 1990 Resolved
E1 REPAIR STEERING GEAR TO PREVENT JUMPING OF RUDDER WHEN ON THE STARBOARD PUMP AND BRIDGE HAND WHEEL CONTROL. (APPEARS AS SERVOS ARE TRYING TO DRIVE ONE WAY AND THEN THE OTHER)
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Navigation
Issued 21 June 1990 Resolved
E2 REPAIR HYDRAULIC LEAK ON PORT RAM IN STEERING GEAR ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990 Resolved
E3 REPLACE LIGHTS ON EMERG GEN FOR LOW LUBE OIL, HIGH TEMP AND POWER AVAILABLE AND PROVE OPERATION.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990 Resolved
E4 TEST EMERG GEN AND AUX GEN OVERSPEEDS, LOW LUBE OIL ALARM AND SHUT DOWN AND HIGH TEMP ALARMS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Engineering
Issued 21 June 1990 Resolved
E5 REPLACE/CALIBRATE PRESSURE GAUGE NEXT TO THE CONT AIR, AIR RECEIVER.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 29 March 1985 Resolved
INSPECT PILOT LADDERS AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
INSPECT LINE THROWING GUN AND ALL SHIP AND LB PYRO AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Fire Fighting
Issued 29 March 1985 Resolved
TEST ALL FIREHOSES,INSPECT FIREMAIN AND FIRESTATIONS FOR HOSES,EXTINGUISHERS,AXES,NOZZLES,SPANNERS AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Fire Fighting
Issued 29 March 1985 Resolved
INSPECT EMERGENCY GEAR LOCKERS,INCLUDING FIREMANS OUTFITS,INTL SHORE CONNECTION.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Accommodation/Occupational Safety
Issued 29 March 1985 Resolved
TEST ALL VENTILATION STOPS AND VENT/AC TRIPS AND REMOVAL OF D/H SYSTEM FROM VENT AND FIRE MAIN SYSTEMS AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Navigation
Issued 29 March 1985 Resolved
TEST ALL ELECTRONIC NAVIGATION EQUIPT,NAV LITES,GYRO,ETC IN PILOT HOUSE ANDINSPECT CHARTS,PUBS,ETC AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
STOCK FIRST AID/HOSPITAL EQUIPT AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Accommodation/Occupational Safety
Issued 29 March 1985 Resolved
INSPECT GALLEY,REEFER BOXES,REEFER UNITS AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Fire Fighting
Issued 29 March 1985 Resolved
PROVIDE EXTRA COPY OF FIRE CONTROL PLAN FOR GANGWAY PER SOLAS 74 AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
PROVIDE PFDS WITH LIGHTS AND WHISTLES ALSO SURVIVAL SUITS ADEQUATE FOR PERSONS ALLOWED BY COI AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
INVENTORY AND PLACE RING BOUYS AND WATER LIGHTS ON STATION AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Engineering
Issued 29 March 1985 Resolved
PROVE OPERATION OF ALL PUMPS,GENERATORS,BOILER CONTROLS,STEERING,ETC IN RELIABLE OPERATION AT REACTIVATION.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Electrical
Issued 29 March 1985 Resolved
TEST ALL GENERAL ALARMS AT REACTIVATION.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Fire Fighting
Issued 29 March 1985 Resolved
SERVICE AND LIGHT OFF FIXED CO2/SMOKE DETECTION CABINET FOR CARGO HOLDS ANDMACHINERY SPACES AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
INVENTORY LIFEBOAT EQUIPT AND RESTOW BOATS AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
PROVIDE RECENTLY SERVICED INFLATABLE LIFERAFTS IN PLACE AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Navigation
Issued 29 March 1985 Resolved
HAVE FCC CHECK PORTABLE LB RADIO,EPIRB,AND ALL RAIOD EQUIPT AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Lifesaving
Issued 29 March 1985 Resolved
TEST MOTOR AND HAND PROPELLED LIFEBOATS AT REACTIVATION.
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985
Fire Fighting
Issued 29 March 1985 Resolved
CONDUCT FIRE AND BOAT DRILL AT REACTIVATION
Condition: Unknown
Due 29 March 1985
Resolved 29 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.