Inspection history · 81
13 August 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3297175
24 April 2007
Hull Examination · Internal Structural Exam · MARPOL Annex I Examination · Cargo Tank Internal · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2914349
15 September 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2778978
14 September 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2778389
12 July 2006
MARPOL Annex I Examination · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2713225
10 June 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2385895
7 June 2005
MTSA Verification · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2382217
3 May 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2352897
4 January 2005
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2268744
26 July 2004
MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2146031
24 June 2004
Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2109560
16 June 2004
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2101440
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1978442
23 December 2003
Annual Inspection · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1968726
3 November 2003
Initial Construction-Excluding Oversight · Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2039464
17 July 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1647563
3 June 2002
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1625331
3 June 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1628774
29 May 2002
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1622698
26 April 2002
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1609536
27 March 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1597961
24 August 2001
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1076545
1 August 2001
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1444583
14 March 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 487717
11 March 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 99894
13 October 2000
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1436471
12 October 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 520370
23 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1052745
3 January 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 812427
20 September 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 472377
13 August 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406529
23 April 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 88114
30 December 1998
Re-Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1378544
6 May 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1124889
23 March 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1124473
18 March 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1110283
4 March 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 783082
23 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 498576
23 February 1998
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1394900
22 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1404
20 February 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1383779
22 January 1998
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1424527
29 December 1997
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368529
29 May 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 498201
26 March 1997
Re-Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1465299
22 November 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 494520
23 September 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 538991
1 August 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 55953
17 July 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 476688
16 May 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 527349
29 January 1996
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1396441
11 April 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 492091
23 February 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1171648
6 February 1995
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1355079
26 January 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 667044
29 December 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 126599
20 September 1994
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1180733
7 September 1994
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 828622
7 September 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1454121
8 June 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1014137
25 March 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 507426
15 February 1994
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1412602
18 October 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1146067
11 August 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1158879
23 July 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 499279
22 April 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 128692
6 April 1993
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1451851
14 March 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 488161
11 January 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1141310
13 February 1992
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 961789
5 February 1990
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 908829
16 June 1989
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1196924
11 March 1989
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1203188
30 December 1988
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1037311
15 February 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1021104
1 February 1988
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1021102
7 May 1987
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1330823
28 January 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 509938
26 November 1986
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1022091
21 May 1986
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1303297
20 November 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 436802
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 13 August 2008
Resolved
Trace and resolve ground in 120 volt system.
Due 13 September 2008
Resolved 30 June 2025
Resolution: Vessel Deactivated
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 13 August 2008
Resolved
Resolve locking issue for accomodation spaces - should not be able to be perm. locked from outside.
Due 13 September 2008
Resolved 30 June 2025
Resolution: Vessel Deactivated
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 13 August 2008
Resolved
Install locking mechanism/hatch for stove.
Due 13 September 2008
Resolved 30 June 2025
Resolution: Vessel Deactivated
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 August 2008
Resolved
Label entrances to bow rake "Danger - Keep Out"
Due 13 September 2008
Resolved 30 June 2025
Resolution: Vessel Deactivated
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 13 August 2008
Resolved
Properly install hydrostatic release for liferaft.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2008
Resolved 13 August 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 13 August 2008
Resolved
Install smoke detector in berthing area.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2008
Resolved 30 June 2025
Resolution: Vessel Deactivated
Fire Fighting › Means of Escape › Escape Route Signs
Issued 13 August 2008
Resolved
Label escape hatch from pump room to E/R
Due 13 September 2008
Resolved 30 June 2025
Resolution: Vessel Deactivated
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 August 2008
Resolved
Repair water tight door to pump room to allow it to fully close and sear.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2008
Resolved 30 June 2025
Resolution: Vessel Deactivated
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 13 August 2008
Resolved
Provide B-V extinguisher IAW COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2008
Resolved 30 June 2025
Resolution: Vessel Deactivated
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 26 April 2002
Resolved
Ground detection lights for 440V and 120V systems not working
Condition: Unknown
Due 23 May 2002
Resolved 23 May 2002
Resolution: Electrician repaired ground lights.
Electrical › Electrical Distribution System (service)
Issued 26 April 2002
Resolved
Amp meter inoperable. LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Due 23 May 2002
Resolved 23 May 2002
Resolution: Electrician renewed amp meter
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 26 April 2002
Resolved
Overspeed devices for both port and stbd generators set beyond maximum allowed RPM.
Condition: Unknown
Due 23 May 2002
Resolved 23 May 2002
Resolution: Electrician reset both overspeed trips to within 15% of max rated speed.
Pollution Prevention/Response › Prevention Equipment
Issued 26 April 2002
Resolved
Rising stick overfill device for #4 port and #5 stbd cargo tanks need to be repaired or replaced due to apparent magnet failure within the device. Vsl rep wanted to order new ones and replace them. Issued CG835 to repair or replace prior to carriage of cargo in those tanks. LEGACY COMPONENT DESC: Overfill Devices
Condition: Unknown
Due 22 June 2002
Resolved 3 June 2002
Resolution: Replacement magnets were installed and owner rep. attests that the sensors are working properly. ACID accepted fax statement that included invoice receipt of the replacement parts.
Deck/Cargo
Issued 1 August 2001
Resolved
Provide test report that cargo piping pressure guages have been tested and are operating properly.
Condition: Unknown
Due 21 August 2001
Resolved 27 August 2001
Electrical
Issued 1 August 2001
Resolved
Conduct permanent repairs to electrical kick pipe for the aft stern light. To be completed at the next drydock.
Condition: Unknown
Due 26 March 2002
Resolved 27 August 2001
Lifesaving
Issued 1 August 2001
Resolved
Renew the pressure relief valve for the ship service air receiver.
Condition: Unknown
Due 21 August 2001
Resolved 27 August 2001
Deck/Cargo
Issued 1 August 2001
Resolved
Provide results of hydro test of cargo piping to 1 1/2 times the maximum allowable working pressure.
Condition: Unknown
Due 21 August 2001
Resolved 27 August 2001
Deck/Cargo
Issued 1 August 2001
Resolved
Provide test report on lifting pressures for the relief valves for both cargo pumps.
Condition: Unknown
Due 21 August 2001
Resolved 27 August 2001
Lifesaving
Issued 1 August 2001
Resolved
Renew metal red transfer flag at next drydock, flag pole 75% wasted.
Condition: Unknown
Due 26 March 2002
Resolved 27 August 2001
Deck/Cargo
Issued 1 August 2001
Resolved
Renew base of port kingpost as orginal at next drydock.
Condition: Unknown
Due 26 March 2002
Resolved 23 May 2002
Resolution: Renewed base of Kingpost. Further wastage was later found above winch mount. Cropped and installed insert and doubler cap. This was accepted because winch, boom and lifting gear were removed and Kingpost will be used as a flood light post only.
Fire Fighting
Issued 1 August 2001
Resolved
Place B-II fire extinguisher located at the bottom of the pump room ladder in a proper bracket.
Condition: Unknown
Due 21 August 2001
Resolved 27 August 2001
Lifesaving
Issued 1 August 2001
Resolved
In the presents of a Coast Guard Marine Inspector conduct a hydro test of the ship service air receiver to 1 1/4 times the maximum allowable working pressure.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Electrical
Issued 30 December 1998
Resolved
PROVIDE COVER FOR MAIN BATTERY BOX IN MACHINERY SPACE.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Electrical
Issued 30 December 1998
Resolved
PROVIDE CAPS/CLOSURE FOR OPEN CONDUIT IN MACHINERY SPACE JUNCTION/PANEL.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Construction/Loadline
Issued 30 December 1998
Resolved
RESTORE AND REMARK WASTED & UNREADABLE STARBOARD LOADLINE.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Deck/Cargo
Issued 30 December 1998
Resolved
STENCIL WORDS "OIL SERVICE" OR SPECIFIC CARGO NAME ON OUTBOARD STARBOARD CARGO HOSE.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Engineering
Issued 30 December 1998
Resolved
PROVIDE MACHINERY GUARD, FRONT OF ENGINE FOR STARBOARD GENERATOR, LOCATED IN STARBOARD MACHINERY SPACE.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Deck/Cargo
Issued 30 December 1998
Resolved
REPLACE 30x30 MESH FLAME SCREENS ON ALL COMMOM HEADER P/V VALVES.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Documentation
Issued 30 December 1998
Resolved
AMMEND OIL TRANSFER PROCEDURES, TO INCLUDE "CLOSURE OF SMALL DISCHARGE CONTAINMENT DRAINAGE VALVES DURING LOADING OPERATIONS".
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Documentation
Issued 18 March 1998
Resolved
PROVIDE ABS REPORT OF TEMPORARY REPAIR CONDITION/STATUS OF STARBOARD FORWARD RAKE TO MSO SAN JUAN OFFICE.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Construction/Loadline
Issued 23 February 1998
Resolved
PERFORM PERMANENT REPAIRS TO TWO THROUGH HULL CUTS ON THE FORWARD RAKE, STARBOARD SIDE.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Electrical
Issued 22 January 1998
Resolved
REMOVE OR PROPERLY DEADEND DISCONNECTED ELETRICAL WIRING INSIDE ELETRICAL JUNCTION BOX LOCATED NEXT TO CARGO PUMP TO BE CORRECTED NO LATER THAN 22FEB98.
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Electrical
Issued 22 January 1998
Resolved
SEAL UNUSED STUFFING TUBES IN ELETRICAL JUNCTION BOX BEHIND GENERATOR. TO BE CORRECTEDE NO LATER THAN 22FEB98
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Construction/Loadline
Issued 22 January 1998
Resolved
GAS FREE AND MAKE AVALIBLE FOR COAST GUARD INSPECTION #2 PORT DOUBLE BOTTOM. PROVIDE SATISFACTORY GAS FREE CERTIFICATE. TO BE COMPLETED NO LATER THAN 22FEB98_x001C_ _x001C_
Condition: Unknown
Due 22 January 1998
Resolved 22 January 1998
Lifesaving
Issued 29 December 1997
Resolved
GAS FREE AND MAKE SAFE FOR ENTRY VIA MARINE CHEMIST TO NUMBER 2 PORT DOUBLEBOTTOM TANK AS PER CASE NUMBER MI97002836.
Condition: Unknown
Due 22 January 1998
Resolved 9 February 1998
Fire Fighting
Issued 29 December 1997
Resolved
PROVIDE PROPER FIRE EXTINGUISHER MOUNTING BRACKETS FOR TWO PORTABLE CO2 EXTINGUISHERS BOTTLES IN STARBOARD SIDE MACHINERY SPACE.
Condition: Unknown
Due 22 January 1998
Resolved 9 February 1998
Engineering
Issued 29 December 1997
Resolved
REPAIR SIGHTGLASS COOLANT TANK STARBOARD SIDE IN MACHINERY SPACE FOR GENERATOR.
Condition: Unknown
Due 22 January 1998
Resolved 9 February 1998
Electrical
Issued 29 December 1997
Resolved
INSTALL PROPER C.B. BLANKS TO CIRCUIT BREAKER POWER DISTRIBUTION PANEL RIGHT SIDE.
Condition: Unknown
Due 22 January 1998
Resolved 9 February 1998
Accommodation/Occupational Safety
Issued 29 December 1997
Resolved
CONDUCT INTERNAL EXAM OF AIR RECEIVER TANK IN MACHINERY SPACE.
Condition: Unknown
Due 20 March 1998
Resolved 23 February 1998
Electrical
Issued 29 December 1997
Resolved
REMOVE DEAD END CABLE ON DECK-AFT OF PORT CARGO PUMP PRIME MOVER.
Condition: Unknown
Due 22 January 1998
Resolved 9 February 1998
Electrical
Issued 29 December 1997
Resolved
REPAIR OVERSPEED TRIP TO PORT GENERATOR.
Condition: Unknown
Due 22 January 1998
Resolved 9 February 1998
Construction/Loadline
Issued 29 December 1997
Resolved
REPLACE GASKET TO WATER TIGHT DOOR IN CARGO PUMP ROOM.
Condition: Unknown
Due 22 January 1998
Resolved 9 February 1998
Engineering
Issued 29 January 1996
Resolved
Repair throttles on both pump engines to eliminate strings with nuts.
Condition: Unknown
Due 29 February 1996
Resolved 13 February 1996
Electrical
Issued 29 January 1996
Resolved
Remove loose wires on aft bulkhead behind port pump engine and over batterybox stbd side of pump room.
Condition: Unknown
Due 29 February 1996
Resolved 13 February 1996
Deck/Cargo
Issued 29 January 1996
Resolved
Repair oil leak on hydralic oil pipe at fwd bulkhead of pump room.
Condition: Unknown
Due 29 February 1996
Resolved 13 February 1996
Construction/Loadline
Issued 29 January 1996
Resolved
Procure and install bilge pump shutdown button label.
Condition: Unknown
Due 29 February 1996
Resolved 13 February 1996
Engineering
Issued 29 January 1996
Resolved
Make port pump engine remote shutdown operable from amidships location.
Condition: Unknown
Due 29 February 1996
Resolved 13 February 1996
Electrical
Issued 6 February 1995
Resolved
Drill 1/4 inch drainage holes at 5 foot intervals along entire length of electrical wire conduit on main deck.
Condition: Unknown
Due 1 March 1995
Resolved 8 March 1995
Documentation
Issued 6 February 1995
Resolved
Provide copy of chemical testing program results for previous year. This document should reflect testing results for all personnel employed in maritime operations.
Condition: Unknown
Due 1 March 1995
Resolved 8 March 1995
Electrical
Issued 6 February 1995
Resolved
Install protective guards over pumproom generator flywheels.
Condition: Unknown
Due 1 March 1995
Resolved 8 March 1995
Construction/Loadline
Issued 15 February 1994
Resolved
Replace hatch dog on starboard after escape hatch where missing.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Engineering
Issued 15 February 1994
Resolved
At drydock replace or repair port after cargo pump exhaust where wasted on the weather deck.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Unknown
Issued 15 February 1994
Resolved
Make available for inspection the air receiver in the after machinery space. Inspection may be conducted by visual internal exam or if air receiver can not be sufficiently inspected internally a hydrostatic test to1.25 times the MAWP will be required.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Lifesaving
Issued 15 February 1994
Resolved
Repair or remove cable run support on deck in way of valve number 22.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Lifesaving
Issued 15 February 1994
Resolved
Install hand guards around pulleys on forward winch motor.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Construction/Loadline
Issued 15 February 1994
Resolved
Sand knife edges on all hatch coamings to remove excess paint that preventsproper hatch seating.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Deck/Cargo
Issued 6 April 1993
Resolved
Make permanent repairs to cargo piping in the following areas where pipe has been clad welded: Approx 6' forward of deckhouse. Inway of flange teeat aft maniforld piping.
Condition: Unknown
Due 6 April 1993
Resolved 6 April 1993
Documentation
Issued 6 April 1993
Resolved
Provide copy of vessel response plan to G-MEP-6 in accordance with NVIC 8- 92. Prior to cargo operations at next U.S. Port.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Deck/Cargo
Issued 1 February 1988
Resolved
REPLACE FLAME SCREEN ON ULLAGE OPENING #4S.
Condition: Unknown
Due 1 February 1988
Resolved 1 February 1988
Deck/Cargo
Issued 1 February 1988
Resolved
REPLACE GASKETS ON ULLAGE OPENINGS #2P, #2S AND #4P
Condition: Unknown
Due 1 February 1988
Resolved 1 February 1988
Deck/Cargo
Issued 1 February 1988
Resolved
IDENTIFY CARGO HOSES WITH LAST TEST REPORT LOCATED ONBOARD BARGE.
Condition: Unknown
Due 1 February 1988
Resolved 1 February 1988
Electrical
Issued 7 May 1987
Resolved
MAKE REPAIRS TO THE PORT GENERATOR OVERSPEED TRIP. NOTIFY CG OFFICE WHEN REPAIRS AND TESTED. ITEM SHOULD TRIP 10-15% OVER RATED SPEED.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987