Inspection history · 56
18 August 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8467271
5 June 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8152612
22 January 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8067521
18 September 2024
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8004621
3 June 2024
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7926598
8 January 2024
COI Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7845527
23 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7627091
24 November 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7599331
13 November 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7593413
13 November 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7651401
3 April 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7423986
17 February 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7397799
8 November 2021
MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7347092
8 June 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6971352
22 July 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6758310
25 April 2019
MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6670288
29 August 2018
Administrative Inspection · Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6526647
13 November 2016
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6040411
13 November 2016
Damage Survey · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6040554
18 October 2016
MTSA/ISPS Verification · Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6024535
28 October 2015
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5752444
12 May 2015
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5124158
27 April 2015
MARPOL
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5111483
20 November 2014
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5026799
20 November 2014
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5027147
20 November 2014
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5027787
7 September 2014
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4977901
7 May 2014
MTSA/ISPS Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4852762
29 October 2013
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4743151
12 April 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4567817
12 April 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4574854
24 January 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4521705
5 October 2011
MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4161307
5 July 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4069718
11 March 2011
Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3962066
2 November 2010
Examination of Repairs · Uninspected Other
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3883222
28 June 2010
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3779897
28 June 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3796150
14 December 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3675842
8 October 2009
Industry Initiated Exam · MARPOL · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3661918
30 April 2009
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3467180
5 February 2008
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3143769
27 September 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2788345
31 August 2006
MTSA/ISPS Verification · Uninspected Other
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2765767
1 May 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2637724
23 March 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2609252
23 March 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2627321
23 March 2006
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2628150
23 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2629354
3 May 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2352897
12 November 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2239618
29 November 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 656656
2 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 71365
2 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 477726
1 February 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 216394
12 February 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 182426
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 June 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel reported an oil leak from the reduction gear. Vessel is restricted from operations until cleared with TPO.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2025
Resolved 6 June 2025
Resolution: TPO attended vessel verified repairs. Sea trial was conducted found all Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2024
Resolved
The fuel shutoff valve must be operable from a safe place outside where the valve is installed. Starboard upper fuel shutoff inoperable; To be repaired to the satisfaction of the TPO. Vessel is restricted from utilizing starboard fuel supply line until repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 16 January 2024
Resolution: The starboard upper fuel shutoff was repaired to original by inserting a bolt and nut in the actuator coupling and shutoff was demonstrated
operable (open and close of valve from external position) to the satisfaction of the attending Surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 January 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or essential system develops problems that require attention, to include high bilge level alarm. Engine room bilge alarm did not sound or visually indicate at the operating station when tested; To be repaired to satisfaction of the TPO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2024
Resolved 16 January 2024
Resolution: The engine room bilge alarm (and all engine room alarms) sound and visually indication repaired by replacing a relay and contact pins in the
main panel in the engine room and alarms demonstrated operating normally to the satisfaction of TPO.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 November 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards.
The port main exhaust manifold caught fire; identify cause of the fire, repair if needed, and provide TPO report to the satisfaction of the Coast Guard.
46 CFR 142.220
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 November 2022
Resolution: See TPO Report in Documents
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 November 2022
Resolved
Each District Commander or Captain of the Port may order a vessel to operate or anchor in the manner directed when the District Commander or Captain of the Port has reasonable cause to believe that the vessel is not in compliance with any regulation, law or treaty. Vessel shall receive tug escort while transiting to Sewell's Point to conduct repairs on inoperable generator.
Action required: 705 - Other - as specified
Resolved 15 November 2022
Resolution: A new generator, approved in ABS report 5256471 was installed at this time. Generator was tested under load with no faults found.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 23 March 2006
Resolved
Cargo pump on ITB barge was inop. Repairs to be conducted in NOLA.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2006
Engineering › Generator (propulsion/auxiliary-electric) › Fuse (overload/over current protection)
Issued 23 March 2006
Resolved
Stbd generator was unable to hold full load.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2006